0% found this document useful (0 votes)
520 views8 pages

Humidity Sensor User Manual

The AM1011A Technical Manual details a temperature and humidity sensor that offers analog voltage output, high precision, and low power consumption, making it suitable for various applications such as HVAC systems and medical equipment. It emphasizes the sensor's stability, interchangeability, and the importance of proper storage and handling to maintain accuracy. The manual also includes specifications, performance characteristics, and recovery processing instructions for optimal use.

Uploaded by

Cường Lê
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
520 views8 pages

Humidity Sensor User Manual

The AM1011A Technical Manual details a temperature and humidity sensor that offers analog voltage output, high precision, and low power consumption, making it suitable for various applications such as HVAC systems and medical equipment. It emphasizes the sensor's stability, interchangeability, and the importance of proper storage and handling to maintain accuracy. The manual also includes specifications, performance characteristics, and recovery processing instructions for optimal use.

Uploaded by

Cường Lê
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

AM1011A Technical Manual

Temperature and Humidity Sensor

•Completely interchangeable

•Analog voltage output

•Excellent long-term stability

•Low power consumption, small size, high cost performance

Product overview
AM1011A analog temperature and humidity module is a temperature and humidity sensor with
calibrated analog signal output.This module has high precision, high reliability, good
consistency, and with temperature compensation, to ensure good long-term stability, easy to
use and high cost performance characteristics, especially suitable for the quality, cost
requirements of more demanding enterprises.

Application scope
HVAC system, dehumidifier,test and inspection equipment,consumer goods,automobiles,automatic
control, data recorder,weather station,household appliances,humidity regulation,medical and other related
temperature and humidity detection and control.

20. 00

12. 90±0.5mm
39.90
44.40

10.60

24 0m m±5m m

Figure 1: AM1011A Sensor Package Diagram (Unit: mm Unmarked tolerance: 0.2 mm)

Versior:V1.0 1/8
AM1011A Technical Manual

Sensor performance
Relative humidity Temperature
The humidity sensor is NTC10k thermistor temperature,
Parameter Condition Min Typical Max Unit and the sensor parameters are shown in table 2.
Resolution ratio
1
Measuring range extended
See Operating
Accuracy 2 Figure 2 Specifications
Rated zero power B Coefficient of
heat transfer
Thermal time Rated power temperature
resistance (R25) constant(S) (mw)
(K) (mw/℃) range(℃)
Repeatability
CN0603R103B3435FT 10KΩ 3435 ≥ 2.5 ≤ 18 150 -40~80
Interchangeability completely interchangeable

Response time 3 Table2 Technical parameters of 10K NTC B3.3435

Hysteresis

Drift 4

Table 1 Humidity Characteristic

Electric specification
Parameter Condition Min Typical Max Unit
Voltage 4.75 5.0 5.25 V
Humidity voltage
output range 0 3 V
Power
consumption
5 Measure 1.5 mA
Humidity sampling period 2 2.5 S
Sensor humidity(%RH)

Temperature range NTC 10K -40 80 ℃


Temperature output NTC 10K - - - -

Maximum greatest limit


deviation of humidity :3.0% Table3 Electric specification
Sensor humidity
Maximum greatest lower bound
deviation of humidity :3.0%

Air humidity(%RH)

Figure2 the maximum error of relative humidity at 25℃

1 Normal working scope: 0 - 80% RH. Sensor reading will be deviated if beyond this 3 The time required to reach 63% of the first-order response under the conditions of 25℃
range, (drift < 3% RH after 200 hours at 90% RH humidity). The working scope is and 1 m/s air flow.
further limited to - 40– 80℃.
4 If the sensor is surrounded by volatile solvents, irritating tapes, adhesives and
2 This precision is the test precision of the sensor with 5V voltage at 25℃ excluding packaging materials, the reading may be higher. For more information, please
hysteresis and nonlinearity, and only suitable for non-condensation conditions. refer to the relevant documents.
5 The minimum and maximum of power consumption are based on the conditions of
VDD = 5 V and T < 60 ℃ . The average value is value measured every two seconds.

Versior:V1.0 2/8
AM1011A Technical Manual

AM1011A User Guide 2 Application information


1 Expansion of performance 2.1 Storage conditions and instructions
1.1 Working conditions The humidity sensitivity level (MSL) is 1, according to
IPC/JEDEC J-STD-020 standard. Therefore, it is
The sensor performance is stable in the suggested recommended to use it within one year after delivery.
working scope, as shown in Figure 3.Long-term
exposure to abnormal scope,especially when Humidity sensor is not an ordinary electronic
humidity > 80%,may lead to temporary signal drift component, and it needs careful protection, which
(drift + 3% RH after 60 hours).When the sensor is users must pay attention to. Long-term exposure to
restored to normal working conditions,it will slowly high concentration of chemical vapor will cause the
restore itself to the correct state.Refer to Recovery sensor reading to drift.Therefore, it is recommended
Processing in Section 2.2 to speed up the recovery that the sensor be stored in the original package
process.Long-term use under abnormal conditions including sealed ESD bag, and meet the following
will accelerate the aging of products. conditions: temperature range 10℃- 50℃(0 - 85℃
in a limited time), humidity 20 - 60% RH (no ESD
100 packaged sensor). For sensors that have been
Maximum range removed from the original package, we recommend
80 that they be stored in antistatic bags made of metal
PET / AL / CPE.
Normal Range

60
Normal Range During production and transportation, sensors should
40
avoid exposure to high concentration of chemical
20 solvents and prolonged exposure. Avoid exposure to
volatile glue, adhesive tape, stickers or volatile
0 packaging materials, such as foamed foil, foam
-40 -20 0 20 40 60 80 100 material, etc. The production area should be well
Figure 3 Working Conditions Temperature (℃)
ventilated.

1.2 RH accuracy at different temperatures 2.2 Recovery processing


The RH accuracy at 25℃ is defined in Figure. 2, and As mentioned above, if the sensor is exposed to
the typical humidity error at other temperatures extreme working conditions or chemical vapor, the
is shown in Fig. 4. reading will drift. It can be restored to the calibration
±5 state by processing as follows.
100 ±6 ±5 ±5 ±6 ±8
±4 Drying: Keep for 10 hours at 80 - 85℃ and less than
90
5% RH humidity.
Relative Humidity (%RH)

±7
80
Rehydration: Keep for 12 hours 6 at 20 - 30℃ with the
70
humidity of more than 75 % RH.
60 ±5 ±4 ±3 ±4 ±5 ±6
50
40 2.3 Temperature influence
30 ±6
20 ±5 ±5 The relative humidity of gases depends largely
±4 ±7
10 on temperature. Therefore, when measuring
±5
0 humidity, all sensors measuring the same humidity
0 5 10 1 5 2 0 2 5 3 0 3 5 4 0 4 5 5 0 5 5 6 0 6 5 7 0 7 5 8 0 should work at the same temperature as possible.
Temperature (℃) When testing, it is necessary to ensure that the
Figure 4 Typical humidity error between 0~80 °C, unit: (% RH) tested sensors and reference sensors are at the
Note: Above errors are the tested typical errors (excluding same temperature, and then compare the humidity
hysteresis) with the high precision dew-point instrument as readings.
reference instrument.
Moreover, when the measurement frequency is too
high, the temperature of the sensor itself will rise,
which will affect the measurement accuracy. In order
to make its temperature rise below 0.1℃, the
activation time of AM1011A should not exceed 10% of
the measurement time - it is recommended to measure
data every 2 seconds.

6 75%RH can be easily generated from saturated NaCl.

Versior:V1.0 3/8
AM1011A Technical Manual

2.4 Material used for sealing and encapsulation 3.4 Schematic diagram of connection mode
Many materials absorb moisture and act as buffer, of temperature sensor
which will increase response time and hysteresis.
Therefore, the material around the sensor should be
carefully selected. Recommended materials are:
metal materials, LCP, POM (Delrin), PTFE (Teflon),
PE, PEEK, PP, PB, PPS, PSU, PVDF, and PVF.
Material for sealing and bonding (conservative
recommendation): It is recommended to use method
of filling epoxy resin or silicone resin for packaging Wiring diagram of
electronic components. Gases released from these front view rear view temperature sensor

materials may also contaminate AM1011A (see 2.1).


Therefore, the sensor should be finally assembled and Figure 5 Schematic diagram of temperature connection mode

placed in a well-ventilated place, or dried for 24 hours


in an environment of > 50℃, in order to release the
contaminated gas before packaging.
4Electrical characteristics
3 Interface definition
Electric specifications include power consumption, high
Descripition and low voltage of input and output, voltage of power
Pin Color Name
supply. In order to make the sensor communication
1 Red VDD Power(4.75V-5.25V DC) smooth, it is important to ensure that the signal design
is strictly limited to the range given in Tables 3.
2 Yellow Hout Humidity output(0-3VDC)

3 Black GND Ground


The temperature is 4.1 Standard humidity output voltage
4 White Tout NTC10k thermistor (debugging free)
Table 4 Interface definition description
(Conditions:at25℃,Vin=5.0V)Unit:V

Table5 AM1011A Standard humidity output voltage corresponding table

Relative humidity(%RH) 0 10 20 30 40 50 60 70 80 90 100

Output voltage(V) 0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0

Full range of temperature compensation, full range


3.1 The power supply pins(VDD GND) microcontroller calibration output, output impedance,
The power supply voltage of this module is below 5kΩ
4.75v ~ 5.25v, and the recommended power supply
voltage is 5.0v 4.2 Relationship between humidity and output
voltage
3.2 Voltage output signal line(Hout)
Humidity signal is output from the signal line in the Humidity conversion formula:
form of voltage, and the voltage output range is 0-3V. Humidity =Voltage /0.03(%RH)
For the specific relationship between humidity and
voltage, please refer to the voltage and humidity
characteristic table (table 5).

3.3 Temperature output signal line(Tout)


The temperature sensor is 10k NTC b.3435 thermistor
rather than the analog signal output, the user needs to
add read circuit, temperature measurement range is
- 40 ~ 80 ℃.

Versior:V1.0 4/8
AM1011A Technical Manual

4.3 Linear curve of voltage output and humidity The back of the box is also tagged, as shown in figure 8,
and provides additional tracking information.
The humidity measurement range of the sensor is
0-100%RH, and the voltage output is 0-3.0V.The linear
relationship between voltage and humidity is shown in
figure 6: Sensor
Modle: AM1011A
Output voltage(V)

Quantity: 1PCS

XXXXXXXX
Humidity(%RH)
Figure6 Linear curve of voltage output and humidity
Figure8 The label on the color box

4. 4 NTC 10K thermistor temperature


corresponding resistance value table 6.2 Transport packaging
Resistance value of standard temperature output
(free from debugging) : AM1011A is independently packaged in a color box,
each color box is packaged with a sensor, each 100 color
Table6:10K NTC B.3435 temperature and resistance corresponding table boxes are placed in a carton, a total of 100 sensors.The
dimensions of color boxes and cartons are shown in
Temperature
figure 9.
Resistance

10kΩ NTC See attached table for details: resistance - temperature


characteristic table

5 Environmental stability
15mm

If the sensor is used in equipment or machinery, please


make sure that it is the same temperature and humidity
that the sensor used for measurement and the sensor m m
used for reference that have sensed. If the sensor is 38mm 63
placed in the equipment, the reaction time will be
prolonged, so it is necessary to ensure that sufficient Color box size drawing: tolerance ±2mm
measurement time is reserved in the programming.
The AM1011A sensor is tested according to the
enterprise standard of Aosong temperature and
humidity sensor. The performance of sensors under
other test conditions is not guaranteed and cannot be
regarded as a part of sensor performance. Especially
for the specific occasions required by users, we do not
make any commitments.
17.5cm

6 Package
6.1 Tracking information
All AM1011A sensors have laser identification on the
back as shown in figure 7
5 cm
2 2.
ASAIR® AM1011A 15cm
POWER: 4.75-5.25VDC
HUMI: 0...99.9%RH Outer carton dimension drawing: tolerance ±5mm
TEMP:-40...80℃
PRECISION:±3%RH
OUTPUT: 0...3VDC Figure 9 Color box and carton size drawing
SERIE NO: XXXXXXXXXXX
Figure 7 sensor laser identification

Versior:V1.0 5/8
AM1011A Technical Manual

Version

Date Version Page Alteration


2019/03 V1.0 1-8 Initial Version

This manual is likely to change sometime without prior notice.

Attention
Warning of personal injury Quality assurance
Do not apply this product to safety protection devices Our company provides 12-month (1-year) quality
or emergency stop equipment, as well as any other assurance for buyers of its products (calculated from the
applications that may cause personal injury due to date of delivery) based on the technical specifications in
the failure of the product. This product cannot be the data manual of the product published by Aosong. If
used unless there is a special purpose or with an the product is found to be defective under warranty, our
authorization to use it. Please refer to the product company will provide free maintenance or replacement.
data sheet and Application guide before installing, Users need to satisfy the following conditions:
processing, using or maintaining the product. Failure ●Notify our company in writing within 14 days after the
to comply with this recommendation may result in defect is found
death and serious bodily injury. ●The defect of this product will help to find out the
deficiency in design, material and technology of our
If the Buyer intends to purchase or use the Aosong product.
products without any application license and ●The product should be sent back to our company at
authorization, the buyer shall bear all compensation the buyer's expense.
for personal injury and death resulting therefrom, and ●The product should be under warranty.
shall not claim for compensation including various Our company is only responsible for the defective products
costs, compensation fees, lawyers, etc. Expenses and which are used in the occasions that meet the technical
so on with the managers and employees of Aosong requirements of the product. Our company makes no
Company, as well as subsidiaries, agents, distributors, warranties or written representations regarding the use of
etc. its products in special application occasions.
At the same time, the company does not make any
ESD protection commitment to the reliability of the products applied to
Due to the inherent component design, it is sensitive products or circuits.
to static electricity. In order to prevent the damage
and the reduction of the product's performance caused
by static electricity, the necessary anti-static measures
should be taken when applying this product.

Versior:V1.0 8/8
AM1011A Technical Manual

Attached table NTC 10k resistance-temperature characteristic table

℃ ℃

Versior:V1.0 7/8
AM1011A Technical Manual

Versior:V1.0 8/8

You might also like