Working Drawings
Working Drawings
1 2 3 4 5 6 G F E D C B A
Y
6 5 4 3 2 1
200 8,400 200 1,600 1,300 3,400 1,600 1,800 1,400 1,100 2,700 1,400 2,000 1,400
300 Pitch
1,400 2,000 1,400 2,700 1,100 300 Pitch
200 1,200 200 3,200 200 2,500 200 900 200 Fascia board painted Fascia board painted
200 to approval to approval
200 1,950 1,800 1,100 900 1,200 1,250 200
R.C Columns Steel casement window
200
200
200
1,400
1,400
KITCHEN keyed to approval
YARD keyed to approval
3,000
B B
EAST ELEVATION
BEDROOM EAST ELEVATION 1:100 NORTH ELEVATION 1:100
WEST ELEVATION
3,500
1,800
1,800
2
200
A B C D E F G 1 2 3 4 5 6
C C
3,200
3,900
KITCHEN 1,400 1,800 1,600 3,400 1,300 1,600
1,600
1,400
1,600
1,400 2,000 1,400 2,700 1,100
900
Lobby
300 Pitch
D D 300 Pitch
600
1,500 1,100 200 3,200 200
200
Fascia board painted
X X
11,000
11,000
to approval Fascia board painted
to approval
3,400
3,400
MASTER
600 2,300
BEDROOM
4,500
LIVING TV Steel casement window Steel casement window
ROOM
6,600
1,300
200 500
200
WEST ELEVATION 1:100 SOUTH ELEVATION 1:100
200
F F
1,600
1,600
ENTRANCE
1,500
1,500
PORCH
Roof pitch=30°
G G A B C D E F G versatile 28g G.I roofing sheets On, 6 5 4 3 2 1
200
200
200
200
200
200
600 600 100x50mm purlins On,
200 1,800 1,200 1,500 300 2,400 200 1,400 1,800 1,600 3,400 1,300 1,600 Roof trusses assembled from 1,100 2,700 1,400 2,000 1,400
100x100mm rafters On,
200 3,200 200 5,000 200 100x50mm struts & ties On,
100x50mm tie beam. On,
1,400 2,000 1,400 2,700 1,100 100x50mm wallplate anchored
200x400mm R.C to ring beam.
6 beam
200 8,400 200
2,400 150
200mm th.
Y
150
32mm th. floor fin. On,
125mm RC cover slab 600x450mm cover 100mm th. mass conc. flr. slab On,
to engineer's detail and frame SECTION X-X 1:100
mm c/c
NB. 1.Soak pits o be used
600x200mm th. R.c strip footing A142 BRC mesh On,
on soils with good absorption to str. eng. detail. 500g polythene D.P.M On,
Outlet eg sand ,red soil etc
50mm th. murram blinding On,
200
Inlet 10,000
manhole SECTION Y-Y 1:100
manhole TWL 2.Depth to be specified 300mm th. hardcore fill compacted in
150mm th. layers. 1,400 7,500 1,100
500
500
200
Invert level of
300
3,200
F2
4,800
stone wall with 10mm at 150mm
10mm water proofing c/c bothways
rendering to approval
rendering to approval SOAK PIT
FLOOR PLAN
TYPPE CAPACITY NO. OF DESLUDGING DIMENSIONS IN MM
IN PERSONS INTERVAL
A B C D E F1 F2
12,600
12,600
Section A-A 600x450mm MH cover & frame LITRES (YEARS)
6,400
150mm rc cover slab
GL GL A 3000 10 2 800 1000 1000 3000 800 1400 1200
200 800 200 D 200 800 200 B 6000 20 2 800 1400 1200 3600 1400 1500 1400
600 150
140mm thick
7,800
3M masonry wall C 900 30 2 800 1400 1200 3600 1800 1500 1400
200
inlet
D 12000 40 2 800 1600 1400 4000 2000 1500 1300
1:3:6 conc.
A 100 B 100 C
VARIES (3-6M)
100
150
3,000
600
F 22500 100 1.5 800 3600 1800 5600 3000 1850 1500
E
G 45000 200 1.5 800 5600 2800 8600 3600 2040 1500
200mm dia. stone blocks H 67500 300 1.5 800 7600 3800 11600 4000 2260 1500
200
3,400 6,600
for loose ground or where
specified I 90000 400 1.5 800 8800 4400 13400 4600 2380 1500
10,000
ROOF PLAN 1:100
FLOOR PLAN TYPICAL(SOAK PIT)
Project: PROPOSED.............................. Consultants: Location Title Design by: Checked by ARCHITECTURAL NOTES. FIRE NOTES. Revision Date Revision Date
Residential developement GOZA ECO-BUILDERS LIMITED - Kakamega County 1. All works to be carried out in accordance with Local 7. All inspection chambers in drive area to have 1. Automatic booster pump for FHRs to be provided to
Drawn by Authority regulations. heavy duty covers. the satisfaction of the Chief Fire Officer.
Date
ON LR.No........................................................ 2. All figured dimensions to be taken in preference 8. Check all dimensions on site.
Drawing Title APRIL . 2023 to scaled dimensions.
2. 4500 litres reserve for hose reel
Scale
Client As Shown 3. All walls below 200mm to be reinforced with hoop 9. All sanitary work to be in accordance with MOH rules 3. Electrical fire alarm system to the approval of Chief Fire Officer.
1-bedroom Bungalow Status
iron at every alternative course. and regulations and NCC requirements.
Mr. Okola Drawing Number
4. Fire alarm and booster to be provided with
4. Provide damp proof course(D.P.C.) under all walls. 10. 500g polythene sheeting and anti-termite treatment secondary power supply.
Drawing Status : 01 5. P.V. indicates permanent ventilations. to be provided under ground floor concrete slab.
5. 2x9kg Dry Powder Fire Extinguishers at parking areas.
Client's sign...................... Presentation drawings . 6. All drainage passing under building and drive 11. All reinforced concrete works to Structural Eng. detail. 6. 2x9litre water and 1x4.5kg CO2fire extinguishers
area to be of pvc pipe and encased in150mm to be provided per floor.
thick concrete surround.