0% found this document useful (0 votes)
172 views3 pages

ESP32 PLC 14 Datasheet

The ESP32 PLC 14 is a programmable logic controller that operates on a voltage range of 12 to 24Vdc, with a maximum power consumption of 30W and various communication interfaces including USB, RS485, Ethernet, WiFi, and BLE. It features an adjustable clock speed, ample flash memory, and multiple digital and analog I/O options, making it suitable for diverse applications. The device requires careful installation and maintenance to prevent damage and ensure safety, particularly in environments with potential electrical hazards.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
172 views3 pages

ESP32 PLC 14 Datasheet

The ESP32 PLC 14 is a programmable logic controller that operates on a voltage range of 12 to 24Vdc, with a maximum power consumption of 30W and various communication interfaces including USB, RS485, Ethernet, WiFi, and BLE. It features an adjustable clock speed, ample flash memory, and multiple digital and analog I/O options, making it suitable for diverse applications. The device requires careful installation and maintenance to prevent damage and ensure safety, particularly in environments with potential electrical hazards.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

ESP32 PLC 14 Datasheet

013000000001
Technical Features
MODEL TYPE ESP32 PLC 14

Input Voltage 12 to 24Vdc (Fuse protection (2.5A) Polarity protection)

Input rated voltage 24Vdc

Rated Power 8W

I max. 1.5A

Size 100x45x115
1.
Clock Speed Adjustable from 80 MHz to 240 MHz

Flash Memory 16 MB

SRAM 520 KB

Communications USB - RS485 - ETHERNET - WiFi 2.5GHz - BLE 2480 MHz

General Features
Power supply voltage DC power supply 12 to 24 Vdc

Operating voltage range DC power supply 11.4 to 25.4 Vdc

Power consumption DC power supply 30 W MAX.

External power supply Power supply voltage 24 Vdc

Power supply current 300 mA

Dielectric strength 1500 Vac at 50/60 Hz for one minute with a leakage
current of 10 mA max.

Shock resistance 50 m/s² in the X, Y and Z direction 3 times each,


complying with the IEC-60068-2-27:2008 standard.

Ambient temperature (operating) -20 º to 70 ºC

Ambient humidity (operating) 10 % to 90 % (no condensation)

Ambient environment (operating) With no corrosive gas

Ambient temperature (storage) -20 º to 70 ºC

Power supply holding time 2 ms min.

Weight 350 g max

I/Os
Input: GPB 3 - MCP23017SS
IO - 0 Digital
Output: GPIO 12 - ESP32
Input: GPB 2 - MCP23017SS
IO - 1 Digital
Output: GPIO 25 - ESP32
Input: GPB 4 - MCP23017SS
IO - 2 Digital
Output: GPIO 26 - ESP32
Input: GPB 5 - MCP23017SS
IO - 3 Digital
Output: GPIO 27 - ESP32
IO - 4 Digital Input: GPA 4 - MCP23017SS

IO - 5 Digital Input: GPA 6 - MCP23017SS Wireless Operation details


IO - 6 Digital Input: GPA 5 - MCP23017SS WiFi 2.4 GHz to 2.5 GHz
Operating Frequency
BLE 2402-2480 MHz (40 Channels)
IO - 7 Analog 4-20 mA Input: GPIO 32 - ESP32
Analog 0-10 V / Digital 3.3-24V Input: GPIO 34 - ESP32 at 2.5 GHz; Power : 9dBm
WiFi
Transmission Power (EIRP)
BLE at 2480 MHz; Power: 2,7dBm
IO - 8 Analog 4-20 mA Input: GPIO 33 - ESP32
Analog 0-10 V / Digital 3.3-24V Input: GPIO 35 - ESP32

I0 - 9 Relay Output: GPA 7 - MCP23017SS

Expandability
Outputs Q0.0 - Q0.1 - Q0.2 - Q0.3
ModbusRTU with RS485: 32 elements
By default, Outputs 0 to 3 give 5V at HIGH level, but they can be changed to
provide Vdc by software.
Q0 - 0: GPB 7 - MCP23017SS
Q0 - 1: GPB 6 - MCP23017SS Warning
Q0 - 2: GPA 1 - MCP23017SS Consider that depending on your selection when acquiring
the PLC, the model you use will have either two analog
Q0 - 3: GPA 0 - MCP23017SS inputs of 0-10Vdc or 4-20mA, but both cannot coexist in
the same PLC, nor be modified by software.
Vdc is Power Suply Voltage and it can be from 12 to 24Vdc

Pitch for FK-MC 0,5/10-ST-2,5 conector: 2.50 mm


Pitch for MC 1,5/ 2-ST-3,81 conector: 3.81 mm
013000000001

A ZONE
RS-485
RxD: GPIO 16
TxD: GPIO 17
RE, DE: GPIO 5

Relay Output:
Pin GPA7 from MCP23017

Performance Specifications
CPU ESP32
Control method Stored program method
I/O control method Combination of the cyclic scan and immediate refresh processing methods.
Programming language Arduino IDE. Based on wiring (Wiring is an Open Source electronics platform composed of a programming language. “similar to the C”)
Microcontroller ESPRESSIF ESP-WROOM-32UE-N16
013000000001
Warnings Warnings
It must be used a long micro USB-B type cable with the thin plastic part This equipment does not include galvanic isolation between the grounds of
(contour of 2mm). the different systems. This means that if an external device or sensor that
shares the same ground reference (GND) with the system is connected, any
potential difference between these grounds could damage the connected
components. To avoid issues with interference, ground loops, or damage to
external equipment, ensure that all connected devices share the same
Unused pins should not be connected. Ignoring the directive may damage the ground reference or use systems with appropriate isolation. The
controller. recommendations in this case are:
Connection Review: Verify that all ground connections are properly
Before using this product, it is the responsibility of the user to read the
product’s User Guide and all accompanying documentation. made and that there are no significant potential differences
between them.
Industrial Shields PLCs must be powered between 12Vdc and 24Vdc. If a
higher voltage is supplied to the equipment can suffer irreversible damage. Use of Isolation: Consider using galvanic isolators or isolation
transformers if it is necessary to connect equipment with different
Maintenance must be performed by qualified personnel familiarized with the ground references.
construction, operation, and hazards involved with the control.
Maintenance should be performed with the control out of operation and
disconnected from all sources of power. Install Arduino IDE and the Industrial Shields boards

The Industrial Shields Family PLCs are Open Type Controllers. It is required The steps to follow to install our equipment’s to Arduino IDE
that you install the ESP32 PLC 14 in a housing, cabinet, or electric control are:
room. Entry to the housing, cabinet, or electric control room should be limited • Open the Arduino IDE, versión 1.8.0 or superior. If you don’t have it
to authorized personnel.
yet , you can download here
Inside the housting, cabinet or electric control room, the Industrial Shields https://www.arduino.cc/en/Main/Software .
PLC must be at a minimum distance from the rest of the components of a
minimum of 25 cm, it can be severely damaged.
• Press the “Preferences” option to “File” menu and open the
Failure to follow these installation requirements could result in severe preferences window.
personal injury and/or property damage. Always follow these requirements
when installing ESP32 PLC 14.
• In the text box “Additional boards manager URLs”, add the direction:
In case of installation or maintenance of the ESP32 PLC 14 please follow the
instructions marked in the Installation and Maintenance section on the User http://apps.industrialshields.com/main/arduino/boards/package_ind
Guide. ustrialshields_index.json
Do not disconnect equipment when a flammable or combustible atmosphere
is present. • Close the preferences window with the “OK” button.
Disconnection of equipment when a flammable or combustible atmosphere
is present may cause a fire or explosion which could result in death, serious • Click on “Tools” menu, and open the “Boards” submenu, and click the
injury and/or property damage. “Boards Manager” option, to open the Boards Manager window.

• Search “industrialshields-esp32” to the search filter and select to the


list and click “Install”

• Close the “Boards Manager". Once ait is performed that steps, you
are available to select each PLC that you wish to work on “Tools” ->
“Boards” : Industrial Shields ESP32…

Symbology Technical Support


Indicates that the equipment is suitable for direct current only; to You can contact with us using the best channel for you:
identify relevant terminals
Indicates that the equipment is suitable for alternating current
@ [email protected]
only; to identify relevant terminals

To identify the control by which a pulse is started.


www.industrialshields.com
To identify an earth (ground) terminal in cases where neither the
symbol 5018 nor 5019 is explicily required.
Visit our Blog, Forum
To identify the switch by means of which the signal lamp(s) is orTicketing system
(are) switched on or off.
DataSheet Rev. 20250523

CE marking indicates that a product complies with applicable


European Union regulations Check the user guides
Indicates a potentially hazardous situation which,
if not avoided, could result in death or serious injury

To indicate hazards arising from dangerous voltages Visit our Channel