PCP Brochure MK
PCP Brochure MK
Property Standards
for Analytical
Characterization
High-Quality Certified Reference
Materials (CRMs) for Accurate
Calibration of Your Equipment
2
Table of Contents
1. pH Buffers 6
2. Titration – Volumetric Reference Materials 10
3. Karl-Fischer (KF) Standards 11
4. Color Reference Standards 12
5. Ultraviolet/ Visible (UV/VIS), Standards 13
6. Conductivity Standards 14
7. Particle Size Standards 15
8. Viscosity Standards 16
9. Turbidimetry Standards 18
10. Melting Point Standards 18
11. Density Standards 19
12. Total Suspended Solid (TSS) Standards 21
13. Additional Physical Properties (Distillation/Cloud Point/ Freezing
Point/Pour Point/Aniline Point/Cetane Number/Octane Number/
Smoke Point/Cold Filter Plugging Point/Hardness Standards) 22
14. Flash Point and Standards 23
15. Acidity/Total Acid Number (TAN) Standards 24
16. Alkalinity or Total Base Number (TBN) Standards 24
17. Refractive Index Standards 25
18. Refractive Index and Density Multi-Parameter CRMs 25
19. Redox Standards 26
20. Biological Oxygen Demand (BOD), Chemical Oxygen Demand
(COD), Total Organic Carbon (TOC) Standards 26
21. Gel Permeation Chromatography (GPC) Standards 27
3
The Need for Physical and Chemical
Property Standards is Everywhere
Physical and Chemical property standards, as the name suggests, are used to calibrate
instruments used in the analyses of various physical and chemical properties such as melting
point instruments, density meters, turbidimeters, spectrophotometers, color measuring
instruments and colorimeters.
Almost all laboratories in chemical research involve in the measurement of physical and
chemical properties. And the measurement of these properties is key to the determination
of identity and purity of substances and materials. For example, color determination is
very important in statistical quality control (SQC) and statistical process control (SPC). Karl
Fischer titration is the gold standard for water determination in Pharma, Food & Beverage,
Cosmetics, Petrochemicals and Polymer industries. Various types of titrations are employed
for estimations of assay, impurity, acidity/alkalinity, fatty acid content in oils as well as water
hardness. UV-Vis spectroscopic measurements are used in environmental water testing, food
testing & pharmaceutical research. When a new compound is synthesized, its melting point
determination is one of the key parameters to ascertain the chemical structure.
We offer a vast portfolio of Physical & Chemical Property Standards with applications in
almost every industry segment ranging from Pharma, Industrial testing, Environmental, Food
& Beverage and Material Sciences.
Mass -
Kilogram
Find more information on Quality Grades, check Luminous
out: How to Choose the Correct Reference Material Intensity - Length -
Quality Grade Candela kg Metre / Meter
Amount of
s
Time -
This brochure mainly focuses on physical and Substance -
Second
Mole
chemical property standards. However, we also
offer accessories to support your daily calibration K A
requirements. Explore our up-to-date portfolio by
visiting [Link]/physicalproperties
Temperature - Electric Current -
Kelvin Ampere
4
Our Certified Reference Material-grade Physical &
Chemical Property Standards are analyzed in our
ISO / IEC 17205 accredited laboratories
Achieve consistently reliable results in your laboratory using our CRM standards analyzed
by our ISO/IEC 17025 laboratory according to ISO 17034 specifications. Laboratories that
either work in regulated environments, or are ISO/IEC 17025 accredited, are better prepared
for audits. ISO/IEC 17025 is a recognized international accreditation for laboratories and is
accepted worldwide through the International Laboratory Accreditation Organization (ILAC),
and every country has its own accreditation bodies that are members of the ILAC.
5
1. pH Buffer Standards
Buffer solutions are essential for maintaining proper calibration of pH instruments.
The accuracy of pH measurements is directly affected by the buffer reference
materials used during calibration.
• Trusted: Traceable to SI units via NIST (National Institute of Standards and Technology, USA) and PTB (Physical Technical Institute,
National Metrological Institute of Germany)
• Available in innovative & eco-friendly packaging Titripac® format with ensured stability
6
Table 1. Buffer Standards
Product Product
Product Name Product Name
Number Number
Sodium hydrogen carbonate/sodium carbonate, 40-0101* pH standard solution, pH 1.68 25 °C
1.01962 certified reference material, traceable to NIST SRM,
traceable to PTB 40-0102* pH standard solution, pH 4.01 25 °C
di-Sodium tetraborate decahydrate, certified secondary 40-0115* pH standard solution, pH 4.01 25 °C, JCSS
standard reference material for pH measurement;
1.01964 40-0116* pH standard solution, pH 6.86 25 °C, JCSS
directly traceable to primary SRM from NIST/PTB
pH(S)=9.180 (25 °C) Certipur® 40-0117* pH standard solution, pH 9.18 25 °C, JCSS
Potassium hydrogen phthalate, certified secondary BX1627** Buffer Concentrate, pH 7.0
standard reference material for pH measurement;
1.01965 BX1632** Buffer pH 7.0 Yellow
directly traceable to primary SRM from NIST/PTB pH(S)
= 4.005 (25 °C) Certipur® BX1633** Buffer pH 10.0 Blue
Potassium tetraoxalate dihydrate, certified secondary BX1634** Buffer pH 4.0 Clear
standard reference material for pH measurement;
1.01961 BX1635** Buffer pH 7.0 Clear
directly traceable to primary reference material from
NIST/PTB pH (S) = 1.67₉ (25 °C) Certipur® BX1636** Buffer pH 10.0 Clear
Potassium dihydrogen phosphate/ di-sodium hydrogen BX1641** Buffer pH 10.0 Blue
1.01960 phosphate, certified reference material, traceable to
NIST (SRM), traceable to PTB BX1642** Buffer pH 10.0 Clear
Buffer concentrate (borate/hydrochloric acid), traceable BX1651** Buffer pH 1.0 Clear
1.09888 to SRM of NIST and PTB for 500 mL buffer solution, pH
BX1652** Buffer pH 2.0 Clear
8.00 ± 0.02 (20 °C) Titrisol®
BX1657** Buffer pH 8.0 Clear
Buffer concentrate (citrate/sodium hydroxide),
1.09885 traceable to SRM of NIST and PTB for 500 mL buffer BX1658** Buffer pH 9.0 Clear
solution, pH 5.00 ± 0.02 (20 °C) Titrisol®
BX1628** Buffer pH 4.0 Red
Buffer concentrate (potassium chloride/sodium
1.09893 hydroxide), traceable to SRM of NIST and PTB for 500 BX1656** Buffer pH 6.0 Clear
mL buffer solution, pH 13.00 ± 0.05 (20 °C) Titrisol® EM0180 Buffer pH 12.45
Buffer concentrate (phosphate/sodium hydroxide), BX1653** Buffer pH 3.0 Clear
1.09892 traceable to SRM of NIST and PTB for 500 mL buffer
solution, pH 12.00 ± 0.05 (20 °C) Titrisol® BX1626** Buffer Variety Pack, Kit
Buffer concentrate for buffer solution acc. to WEISE, BX1655** Buffer pH 5.0 Clear
1.09879
for 1000 mL of solution (phosphate), pH 7.20 Titrisol®
EM0182 Buffer pH 1.68
Buffer concentrate (boric acid/potassium chloride/
EM0186 Buffer pH 6.86
sodium hydroxide), traceable to SRM of NIST and PTB
1.09880
for 500 mL buffer solution, pH 11.00 ± 0.05 (20 °C) B5020 Buffer, reference standard, pH 4.00 +/- 0.01 25 °C
Titrisol®
B4895 Buffer, reference standard, pH 10.00 +/- 0.01 25 °C
Buffer concentrate (glycine/hydrochloric acid),
1.09881 traceable to SRM of NIST and PTB for 500 mL buffer Buffer solution, (di-sodium tetraborate), traceable to
1.01645
solution, pH 1.00 ± 0.02 (20 °C) Titrisol® SRM from NIST and PTB pH 9.22 (20 °C), Certipur®
Buffer concentrate (citrate/hydrochloric acid), traceable Calcium hydroxide, for the preparation of DIN 19266
1.02111
1.09882 to SRM of NIST and PTB for 500 mL buffer solution, pH pH standard buffer solutions
2.00 ±0.02 (20 °C) Titrisol® Potassium dihydrogen phosphate solution, (buffer stock
1.04875
Buffer concentrate (citrate/hydrochloric acid), traceable solution) 1/15 mol/L
1.09883 to SRM of NIST and PTB for 500 mL buffer solution, pH di-Sodium hydrogen phosphate solution, (buffer stock
3.00 ±0.02 (20 °C) Titrisol® 1.06587
solution) 1/15 mol/L
Buffer concentrate (citrate/hydrochloric acid), traceable 1.07200 Certified sec. standard reference buffer solution
1.09884 to SRM of NIST and PTB for 500 mL buffer solution, pH
4.00 ±0.02 (20 °C) Titrisol® Certified sec. standard reference buffer solution,
potassium dihydrogen phosphate/di-sodium hydrogen
Buffer concentrate, (citrate/sodium hydroxide), 1.07202
phosphate, traceable to PTB SRM, traceable to PTB
1.09886 traceable to SRM of NIST and PTB for 500 mL buffer SRM, pH 6.86 25 °C, Certipur®, traceable to NIST SRM
solution, pH 6.00 ±0.02 (20 °C) Titrisol®
Certified sec. standard reference buffer solution, di-
Buffer concentrate (phosphate), traceable to SRM of sodium tetraborate decahydrate, directly traceable to
1.09887 NIST and PTB for 500 mL buffer solution, pH 7.00 1.07203
primary SRM from NIST/PTB pH(S) = 9.180 (25 °C),
±0.02 (20 °C) Titrisol® Certipur®
Buffer concentrate (boric acid/potassium chloride/ Certified sec. standard reference buffer solution,
sodium hydroxide), traceable to SRM of NIST and PTB potassium tetraoxalate dihydrate, directly traceable to
1.09889 1.07204
for 500 mL buffer solution, pH 9.00 ±0.02 (20 °C) primary SRM from NIST/PTB pH(S) = 1.679 (25 °C),
Titrisol® Certipur®
Buffer concentrate (boric acid/potassium chloride/ Certified sec. standard reference buffer solution,
sodium hydroxide), traceable to SRM of NIST and PTB potassium dihydrogen phosphate/di-sodium hydrogen
1.09890 1.07205
for 500 mL buffer solution, pH 10.00 ±0.05 (20 °C) phosphate, traceable to NIST SRM, traceable to PTB
Titrisol® SRM, pH 7.41 25 °C, Certipur®
7
Product Product
Product Name Product Name
Number Number
Buffer solution, di-sodium hydrogen phosphate/ Buffer solution (citric acid/sodium hydroxide/hydrogen
1.07294 potassium dihydrogen phosphate, traceable to NIST, 1.09445 chloride), traceable to SRM from NIST and PTB, pH
traceable to PTB, pH 6.88 20 °C, Certipur® 4.00 (25 °C), Certipur®
Buffer solution, (acetic acid/sodium acetate), traceable Buffer solution (citric acid/sodium hydroxide), traceable
1.07827 1.09446
to SRM from NIST and PTB pH 4.66 (20 °C), Certipur® to SRM from NIST and PTB, pH 5.00 (25 °C), Certipur®
Buffer Solution, (boric acid/potassium chloride/sodium Buffer solution (boric acid/sodium hydroxide/hydrogen
1.09400 hydroxide), colour coded: yellow, traceable to NIST 1.09460 chloride), traceable to SRM from NIST and PTB, pH
and PTB pH 10.00 (20 °C), Certipur® 8.00 (20 °C), Certipur®
Buffer solution (potassium hydrogen phthalate), Buffer solution (boric acid/potassium chloride/sodium
1.09406 traceable to SRM from NIST and PTB, pH 4.01 (25 °C), 1.09461 hydroxide), traceable to SRM from NIST and PTB, pH
Certipur® 9.00 (20 °C), Certipur®
Buffer solution (potassium dihydrogen phosphate/ Buffer solution (boric acid/potassium chloride/sodium
1.09407 disodium hydrogen phosphate), traceable to SRM from 1.09462 hydroxide), traceable to SRM from NIST and PTB, pH
NIST and PTB, pH 7.00 (25 °C) Certipur® 11.00 (20 °C), Certipur®
Buffer solution (boric acid/potassium chloride/sodium Buffer solution (citric acid/sodium hydroxide/hydrogen
1.09408 hydroxide), traceable to SRM from NIST and PTB, pH 1.09475 chloride), colour: red, traceable to SRM from NIST and
9.00 (25 °C), Certipur® PTB, pH 4.00 (20 °C), Certipur®
Buffer solution (boric acid/potassium chloride/sodium Buffer solution (boric acid/potassium chloride/sodium
1.09409 hydroxide), traceable to SRM from NIST and PTB, pH 1.09476 hydroxide), coloured: blue, traceable to SRM from
10.00 (25 °C), Certipur® NIST and PTB, pH 9.00 (20 °C), Certipur®
Buffer solution (glycine/sodium chloride/hydrogen Buffer solution (di-sodium hydrogen phosphate/
1.09432 chloride), traceable to SRM from NIST and PTB, pH potassium dihydrogen phosphate), colour: green,
1.09477
1.00 (20 °C), Certipur® traceable to SRM from NIST and PTB, pH 7.00 (20 °C),
Certipur®
Buffer solution (citric acid/sodium hydroxide/hydrogen
1.09433 chloride), traceable to SRM from NIST and PTB, pH Buffer solution (potassium hydrogen phthalate),
2.00 (20 °C), Certipur® 1.99001 traceable to SRM from NIST and PTB, pH 4.01 (25 °C),
Certipur®
Buffer solution (citric acid/sodium hydroxide/hydrogen
1.09434 chloride), traceable to SRM from NIST and PTB, pH Buffer solution (potassium dihydrogen phosphate/di-
3.00 (20 °C), Certipur® 1.99002 sodium hydrogen phosphate), traceable to SRM from
NIST and PTB pH, 7.00 (25 °C), Certipur®
Buffer solution (citric acid/sodium hydroxide/hydrogen
1.09435 chloride), traceable to SRM from NIST and PTB, pH Buffer solution (boric acid/potassium chloride/sodium
4.00 (20 °C), Certipur® 1.99003 hydroxide solution), traceable to SRM from NIST and
PTB, pH 9.00 (25 °C), Certipur®
Buffer solution (citric acid/sodium hydroxide), traceable
1.09436
to SRM from NIST and PTB, pH 5.00 (20 °C), Certipur® Buffer solution (boric acid/potassium chloride/sodium
1.99004 hydroxide), traceable to SRM from NIST and PTB, pH
Buffer solution (citric acid/sodium hydroxide), traceable 10.00 (25 °C), Certipur®
1.09437
to SRM from NIST and PTB, pH 6.00 (20 °C), Certipur®
Buffer solutions, traceable to NIST, traceable to
Buffer solution (boric acid/potassium chloride/sodium 1.99005 PTB, pH 4.01 (25 °C), phthalate, pH 7.00, 25 °C,
1.09438 hydroxide), traceable to SRM from NIST and PTB, pH phosphate, pH 9.00, borate, Certipur®
10.00 (20 °C), Certipur®
Buffer solutions, traceable to NIST, traceable to
Buffer solution (di-sodium hydrogen phosphate/ 1.99006 PTB, pH 4.01 (25 °C), phthalate, pH 7.00 (25 °C),
1.09439 potassium dihydrogen phosphate), traceable to SRM phosphate, pH 9.00, borate, Certipur®
from NIST and PTB, pH 7.00 (20 °C), Certipur®
Buffer solution (Potassium tetraoxalate), traceable to
Buffer solution (glycine/sodium chloride/hydrogen 1.99011
SRM from NIST and PTB, pH 1.68 (25 °C), Certipur®
1.09441 chloride), traceable to SRM from NIST and PTB, pH
1.00 (25 °C), Certipur® Buffer Solution (citric acid, sodium hydroxide,
1.99012 hydrogen chloride), traceable to SRM from NIST and
Buffer solution (citric acid/sodium hydroxide/hydrogen PTB, pH 2.00 (25 °C), Certipur®
1.09442 chloride), traceable to SRM from NIST and PTB, pH
2.00 (25 °C) Certipur® Buffer solution (Potassium tetraoxalate), traceable to
1.99015
SRM from NIST and PTB, pH 1.68 (25 °C), Certipur®
Buffer solution (citric acid/sodium hydroxide/hydrogen
1.09444 chloride), traceable to SRM from NIST and PTB, pH Buffer Solution (citric acid/sodium hydroxide),
3.00 (25 °C), Certipur® 1.99016 traceable to SRM from NIST and PTB, pH 6.00 (25 °C),
Certipur®
8
Product Product
Product Name Product Name
Number Number
Buffer solution (di-sodium tetraborate), traceable to Buffer solution (boric acid/potassium chloride/sodium
1.99019
SRM from NIST and PTB, pH 9.18 (25 °C), Certipur® 1.99050 hydroxide), colour coded: blue, traceable to NIST and
PTB, pH 10.00 (25 °C), Certipur®
Buffer Solution (boric acid, sodium hydroxide,
1.99021 potassium chloride), traceable to SRM from NIST and Buffer solution (citric acid/sodium hydroxide/hydrogen
PTB, pH 11.00 (25 °C), Certipur® 1.99054 chloride), colour: red, traceable to SRM from NIST and
PTB, pH 4.00 (25 °C)
Buffer Solution (di-sodium hydrogen phosphate/sodium
1.99022 hydroxide), traceable to SRM from NIST und PTB, pH Buffer solution (di-sodium hydrogen phosphate/
12.00 (25 °C), Certipur® potassium dihydrogen phosphate), colour:yellow,
1.99057
traceable to SRM from NIST and PTB, pH 7.00 (25 °C),
Buffer solution (citric acid/sodium hydroxide), traceable Certipur®
1.99036
to SRM from NIST and PTB, pH 6.00 (25 °C), Certipur®
Buffer solution (citric acid/sodium hydroxide/hydrogen
Buffer solution (boric acid/sodium hydroxide/hydrogen 1.99064 chloride), traceable to SRM from NIST and PTB, pH
1.99038 chloride), traceable to SRM from NIST and PTB, pH 4.00 (25 °C), Certipur®
8.00 (25 °C), Certipur®
Buffer solution (di-sodium hydrogen phosphate/
Buffer solutions (boric acid/potassium chloride/sodium 1.99068 potassium dihydrogen phosphate), traceable to NIST,
1.99041 hydroxide), traceable to SRM from NIST and PTB, pH traceable to PTB, pH 6.86 25 °C, Certipur®
11.00 (25 °C), Certipur®
Buffer solution (di-sodium tetraborate), traceable to
1.99091
SRM from NIST and PTB, pH 9.18 (25 °C), Certipur®
*Sold in Japan only
**Sold in US only
9
2. Titration – Volumetric Reference Materials
Accurate titer determination is an important criterion for precise and comparable
titration analysis. Our offering of Certipur® volumetric standards include high-
purity secondary reference materials for acidimetry, alkalimetry, argentometry,
complexometric, iodometry and redox titration.
10
3. Karl Fischer Standards
Aquastar® Karl Fischer reagents and standards ensure rapid, precise, and consistent
results for water determination in solid, liquid, and gas samples. Our Aquastar®
product portfolio includes reagents for volumetric and coulometric methods.
Aquastar® water standards are available as certified reference materials according to
ISO 17034 for a precise titer determination, instrument check, and the verification of
titration results.
11
4. Color Reference Standards
Color reference standards are ideal for routine validation
of instruments used for color measurements/colorimeters.
These standards also assure comparison of results
between different laboratories or between different
instruments and hence ensure the accuracy of test data.
They are also widely used in statistical quality control
(SQC) and statistical process control (SPC).
• Supplied with full traceability to internationally recognized standards, either UKAS to ISO 17025 / ISO 17034 (ASTM, Gardner & Saybolt
Color) or the ISO 9001 quality system (AOCS-Tintometer, Lovibond RYBN and Pt-Co Color)
• Accompanied with a detailed certificate of analysis for an effective quality management system
12
Pt-Co/Hazen/APHA Colour Reference Standard, ASTM D Saybolt Colour Reference Standard, ASTM D 6045, D 156
PTCO030 SAYB06
1209 (ASTM colour 30) (ASTM colour 12)
Pt-Co/Hazen/APHA Colour Reference Standard, ASTM D Saybolt Colour Reference Standard, ASTM D 6045, D 156
PTCO050 SAYB07
1209 (ASTM colour 50) (ASTM colour 0)
Pt-Co/Hazen/APHA Colour Reference Standard, ASTM D Saybolt Colour Reference Standard, ASTM D 6045, D 156
PTCO100 SAYB08
1209 (ASTM colour 100) (ASTM colour 10)
Pt-Co/Hazen/APHA Colour Reference Standard, stock Additional Color Standards & Ampoules
PTCO500
solution, ASTM D 1209 (ASTM colour 500)
91711 Sigma-Aldrich Color Chart
Platinum Cobalt Color Standard Solution (HAZEN 500),
1.00246 CLR100 Color 100 Pt-Co Units Calibration Standard
Pt 500 mg/L Certipur®
CLR500 Color 500 Pt-Co Units Calibration Standard
Saybolt Colour Reference Standard
42174 Ampoules 2 mL, for color reference solutions
Saybolt Colour Reference Standard, ASTM D 6045, D 156
SAYB02
(ASTM colour 25) 72671 Ampoules 10 mL, for color reference solutions
1.14724 Empty cells with screw cap
The complete range of our color standards and accessories can be found at: Color Standards
5. UV/Vis Standards
Our UV/Vis standards are ideal for spectrophotometer calibration according to Ph. Eur
specifications. They are suitable for general use following GLP, GMP, USP, ASTM and
DIN ISO 9001:2008 method protocols.
• Manufactured according to USP & [Link] UV-VIS Standard 1a: Potassium dichromate solution
1.04660 (600 mg/L), according to Ph. Eur. absorbance at 430
• Double-certified solutions according to ISO/IEC 17025 and nm, Certipur®
ISO 17034
Potassium dichromate standard solutions in sulfuric
• Following parameters can be determined using UV-VIS 1.08158 acid (0.01N), test set for calibrating the absorbance of
standards according to Ph Eur: spectrophotometers
14
7. Particle Size Standards
Particle size standards are widely used in industrial, pharmaceutical, clinical,
and scientific laboratories. They are used to calibrate a wide variety of particle
measuring devices such as flow cytometers, coulter counters, disc centrifuges,
electron microscopes, optical particle counters and fully automatic, image-based cell
analysis devices.
Product
Features & Benefits Product Name
Number
• All products are traceable to the US NIST and/or the European Micro particle size standard based on polystyrene
87896
Institute for Reference Materials and Measurements (IRMM). monodisperse, analytical standard, size: 20.0 μm
• Only NIST and/or Bureau of Certified References (BCR) Micro particle size standard based on polystyrene
88511
traceable reference materials are used for accurate sizing monodisperse, analytical standard, size: 12.0 μm
• A certificate is supplied for each particle size, containing Micro particle size standard based on polystyrene
89756
important particle data. monodisperse, analytical standard, size: 6.0 μm
Micro particles based on polymethacrylate, analytical
90515
standard, size: 8 μm
Explore the range of polydisperse particle size
standards and sieve calibration standards from 90875
Micro particles based on polymethacrylate, analytical
standard, size: 1 μm
Whitehouse Scientific:
Micro particles based on melamine resin, analytical
91329
7.1. Polydisperse particle size standards standard, size: 3 μm
Micro particles based on melamine resin, analytical
These NIST and NPL (National Physical Laboratory, UK) 95523
standard, size: 8 μm
traceable standards are commissioned by the BCR. For Micro particle size standard based on polystyrene
certification of glass particles, several unambiguous 95531
monodisperse, analytical standard, size: 30.0 μm
primary methods such as microscopy, sieving, Micro particles based on melamine resin, analytical
sedimentation, and coulter counter are used. 95538
standard, size: 12 μm
Micro particle size standard based on polystyrene
72822
7.2. Sieve calibration standards monodisperse, size: 10.0 μm
Micro particle size standard based on polystyrene
The sieve calibration standards from Whitehouse 72938
monodisperse, analytical standard, size: 1.0 μm
Scientific are used to calibrate sieves with traceabilities
Micro particle size standard based on polystyrene
to NIST and NPL. 95581
monodisperse, size: 0.2 μm
The calibration requires only about 2 minutes following Micro particle size standard based on polystyrene
95585
a simple procedure: The glass microspheres are placed monodisperse, analytical standard, size: 0.5 μm
into the sieve which is shaken either manually or Micro particles based on melamine resin, nile blue-
95611
mechanically until an equilibrium has been reached and marked, analytical standard, size: 10 μm
no particles pass through the sieve. Micro particles based on melamine resin, rhodamine
96003
B-marked, size: 10 μm
By weighing the sieve and the single-shot bottle
Micro particles based on melamine resin, analytical
before and after the calibration, the percentage of 96062
standard, size: 10 μm
microspheres passing the sieve can be calculated
Micro particles based on polymethacrylate, analytical
and the mean aperture size of the sieve can thus be 74161
standard, size: 50 μm
determined using the calibration graph supplied with
Micro particles based on polymethacrylate, analytical
the test certificate. 74214
standard, size: 100 μm
Micro particles based on polystyrene, analytical
Table 8. Micro particle Size, Polydisperse and 79807
standard, size: 25 μm
Sieve Standards
Micro particles based on polystyrene, analytical
84135
Product standard, size: 30 μm
Product Name
Number
Micro particles based on melamine resin, carboxylate-
75776
Micro particles based on polymethacrylate, analytical modified, size: 6 μm
77006
standard, size: 60 μm
Micro particles based on polystyrene, analytical
74491
Micro particle size standard based on polystyrene standard, size: 20 μm
80177
monodisperse, analytical standard, size: 2.0 μm
Micro particles based on polystyrene, analytical
74964
Micro particle size standard based on polystyrene standard, size: 15 μm
80304
monodisperse, analytical standard, size: 3.0 μm
56796 Micro particles based on silicon dioxide, size: 0.5 μm
Micro particle size standard based on polystyrene
81494 56798 Micro particles based on silicon dioxide, size: 1.0 μm
monodisperse, analytical standard, size: 4.0 μm
Micro particle size standard based on polystyrene 56799 Micro particles based on silicon dioxide, size: 0.15 μm
84192
monodisperse, analytical standard, size: 8.0 μm 66373 Micro particles based on silicon dioxide, size: 3 μm
Micro particle size standard based on polystyrene
87466
monodisperse, size: 9.0 μm 15
Product Product
Product Name Product Name
Number Number
Micro particles based on polystyrene, dark blue, size: Micro particle size standard based on polystyrene
55463 07091
10 µm monodisperse, size: 200 μm
Micro particles based on polystyrene, dark red, size: 1 Micro particle size standard based on polystyrene
56314 59336
µm monodisperse, size: 100 μm
Micro particles based on polystyrene, dark red, size: 00239 Micro particles, magnetic, carboxy functionalized
61946
10 µm
53572 Micro particles, magnetic, amino functionalized
Micro particles based on polystyrene, dark blue, size:
68553 Micro particles based on polymethacrylate, analytical
3 µm 73371
standard, size: 4 μm
Micro particles based on polystyrene, dark blue, size:
90938 Micro particles based on melamine resin, carboxylate-
100 µm 75845
modified, size: 3 μm
Micro particles based on melamine resin, rhodamine
81715 Micro particles based on polymethacrylate, analytical
B-marked, size: 8 μm 77523
standard, size: 30 μm
41295 Micro particles based on melamine resin, size: 2 μm
Micro particles, magnetic, streptavidin coated, particle
49532
44054 Micro particles based on silicon dioxide, size: 5 μm size 1 µm < 0.1 µm
54375 Micro particles based on silicon dioxide, size: 4 μm Micro particles, magnetic, biotin coated, particle size
79195
1 µm
81108 Micro particles based on silicon dioxide, size: 2 μm
8. Viscosity Standards
Accurate viscosity measurements are key to reliable calibration and validation
of viscometers employed in various industries such as Food & Beverage, Paint &
Coatings, Pharmaceutical and Petroleum.
Our viscosity standards from Paragon Scientific Ltd are appropriate to measure
kinematic and dynamic viscosity values of viscometers. CRMs are traceable to
international standards BS EN ISO / IEC 17025 and ISO 17034 according to
UKAS accreditation.
We offer different types of viscosity standards: Certified at 20°C and 25°C, each value is tested
to ASTM D2162 for viscosity measurement and
1. CCS Viscosity Standards (Cold Cranking ASTM D1480 for density measurement.
Simulator): Paragon ISO 17025 / ISO 17034
dual certified CCS Viscosity Standards are for 5. High Temperature Viscosity Standards:
the calibration and verification of analytical Paragon ISO 17025 / ISO 17034 dual certified
equipment used in Cold Cranking Simulator High Temperature Viscosity Standards are
(CCS) oil testing to ASTM D5293 and SAE manufactured for temperatures between 20 °C
Specification J300. and 150 °C and provide data for kinematic
viscosity, dynamic viscosity and density.
2. Cone & Plate Viscosity Standards (CAP):
Paragon ISO 17025 / ISO 17034 dual certified 6. High Temperature Viscosity Standards, 100
Cone and Plate Viscosity Standards are to 150 °C: We also manufacture a range of High
specifically formulated for the paint and coatings Temperature Viscosity Standards specifically
industry and represent the most comprehensive for temperatures between 100 and 150 °C.
range of standards available for this application. These are dual certified to ISO 17034 and ISO
17025 and are specially formulated to provide
3. General Purpose Viscosity Standards: Paragon values for kinematic viscosity, dynamic viscosity
ISO 17025 / ISO 17034 dual certified General and density.
Purpose Viscosity Standards are tested in strict
accordance with ASTM D2162, (“Standard 7. Low Temperature Viscosity Standards: These
Practice for basic calibration of master standards are widely used for the verification
viscometers and viscosity standard oils”). of viscometers at sub-zero temperatures on
routine basis. The use of Paragon ISO 17025
4. Flow Cup Viscosity Standards: Paragon ISO / ISO 17034 dual certified, low temperature
17025 / ISO 17034 dual certified flow cup standards can help provide confidence in overall
standards are especially designed for use in system functionality including bath uniformity,
DIN, Ford, ISO, Shell and Zahn flow cups. bath stability, temperature measurement, timer
accuracy and viscometer calibration.
16
Product Product
Product Name Product Name
Number Number
Polydisperse Particle Standard, Particle Size Standard, Polydisperse Particle Standard, Particle Size Standard,
05724 78456
PS201, 10 x 0.05 g, 3-30 µm PS226, 10 x 2.5 g, 50-350 µm
Polydisperse Particle Standard, Particle Size Standard, Sieve Standard, traceable to NIST SRM, 500 µm (35
08718 78900
PS315, 10 x 1.0 g, 10-100 µm mesh)
Sieve Standard, traceable to NIST SRM, 45 µm (325 Polydisperse Particle Standard, Particle Size Standard,
12655 80847
mesh) PS213, 10 x 0.25 g, 10-100 µm
Polydisperse Particle Standard, Particle Size Standard, Polydisperse Particle Standard, Particle Size Standard,
40579 94078
PS314, 10 x 0.50 g, 10-100 µm PS202, 10 x 0.10 g, 3-30 µm
Polydisperse Particle Standard, Particle Size Standard, Polydisperse Particle Standard, Particle Size Standard,
42459 94773
PS192, 10 x 0.10 g, 1-10 µm PS235, 10 x 2.5 g, 150-650 µm
Sieve Standard, traceable to NIST SRM, 75 µm (200
42696
mesh) View our diverse list of particle size standards:
49500
Sieve Standard, traceable to NIST SRM, 63 µm (230 Particle Size Standards
mesh)
Polydisperse Particle Standard, Particle Size Standard,
57563
PS224, 10 x 0.50 g, 50-350 µm
8. Medical Viscosity Standards: Tested in strict We also offer Certified Viscosity Check Oils &
accordance with ASTM D2162, the primary Bath Media:
method for viscosity standards calibration.
These medical grade viscosity standards are • Certified Viscosity Check Oils: Paragon Scientific’s
fully traceable to national standards and are also range of Certified Viscosity Check Oils are
test equipment compatible. Typically used, but manufactured and certified in accordance with
not limited to, the calibration and verification of the requirements of ISO 17025 and ISO 17034.
viscosity measuring equipment. Kinematic viscosity measurements have been made
in accordance with ASTM D445, using Reference
9. Mineral Oil Rotational Viscosity Standards: Viscometers certified in accordance with ASTM D446
Paragon Scientific’s Mineral Oil Rotational and ASTM D2162. Density, Cold-Crank Simulator
Viscosity Standards are the first-choice option (CCS) and Viscosity Index measurements have been
where end users are unable to have silicone in made in accordance with ASTM D4052, ASTM D5293
their process. Dual certified to both ISO 17025 and ASTM D2270 respectively.
and ISO 17034 under UKAS accreditation, they
provide both calibration and verification options • Bath Media: Paragon bath fluids are formulated
for rotational viscometer test equipment. The using high quality raw materials that facilitate
dynamic viscosity at 20 & 25 °C is derived optimum visibility, maximum heat stability and
from the kinematic viscosity measured in strict efficiency of thermostatic baths. The low viscosity
accordance with ASTM D2162 and the density aids dissipation of air bubbles which can lead to
measured in strict accordance with ASTM D1480. detection problems in automatic systems and
Dynamic viscosity at intermediate temperatures ensures bath stability and uniformity are optimised.
is derived from the kinematic viscosity • Silicone Fluid Bath Media:
calculated in strict accordance with ASTM
D341 and interpolated density measurements • Silicone Fluid Bath Media available for use at range
by calculation. of temperatures: 20 to 60 °C, 50 to 100 °C, 90 to
135 °C, and 120 to 150 °C
10. Small Sample Viscosity Standards - ASTM
D7279: These standards are certified in strict • Kinematic viscosity (cSt) values at 25 °C
accordance with ASTM D2162 at 40 °C and Browse our extensive portfolio of viscosity standards:
100 °C under our ISO 17025 and ISO 17034 Viscosity Standards
accreditation and have been manufactured
specifically for the users of ASTM D7279,
Standard Test Method for Kinematic Viscosity of
Transparent and Opaque Liquids by Automated
Houillon Viscometer and other similar type
test equipment.
11. Silicone Rotational Viscosity Standards:
Paragon ISO 17025 / ISO 17034 dual certified
Silicone Rotational Viscosity Standards
are specifically formulated for use with
rotational viscometers.
17
9. Turbidimetry Standards
The measurement of turbidity is an important method in water quality testing. Simply
stated, turbidity is the measure of relative sample clarity. Turbidity can be expressed
in nephelometric turbidity units (NTU).
Check out our turbidity standards for use in calibration and in checking the accuracy
of your turbidity measurement instruments.
Table 9. Turbidimetry Standards
Features & Benefits
Product
Product Name
• Analysis range: 0.5-4000 NTU Number
• Quality grade: CRM TURB500 Turbidity 500 NTU Calibration Standard - Formazin
• Traceable to the SI and higher order standards from NIST TURB50 Turbidity 50 NTU Calibration Standard - Formazin
TURB5 Turbidity 5 NTU Calibration Standard - Formazin
TURB05 Turbidity 0.5 NTU Calibration Standard - Formazin
Explore our turbidity standards: Turbidity Standards
TURB1000 Turbidity 1000 NTU Calibration Standard - Formazin
TURB100 Turbidity 100 NTU Calibration Standard - Formazin
TURB10 Turbidity 10 NTU Calibration Standard - Formazin
TURB1 Turbidity 1 NTU Calibration Standard - Formazin
TURB20 Turbidity 20 NTU Calibration Standard - Formazin
TURB2 Turbidity 2 NTU Calibration Standard - Formazin
TURB4000 Turbidity 4000 NTU Calibration Standard - Formazin
TURB4 Turbidity 4 NTU Calibration Standard - Formazin
18
Product Product
Product Name Product Name
Number Number
Mettler-Toledo Calibration substance ME 51143091, Mettler-Toledo Calibration substance ME 30130597,
41131 15809
Saccharin, traceable to primary standards (LGC) p-Toluamide, traceable to primary standards (LGC)
Mettler-Toledo Calibration substance ME 51143095, Mettler-Toledo Calibration substance ME 30130610,
49143 Potassium nitrate, traceable to primary standards 04229 Sodium methanesulfonate, traceable to primary
(LGC) standards LGC
Mettler-Toledo Calibration substance ME 51143093, Mettler-Toledo Calibration substance ME 30130599,
77634
Vanillin, traceable to primary standards (LGC) 42123 Sodium acetate anhydrous, traceable to primary
standards (LGC)
Mettler-Toledo Calibration substance ME 30034252,
44770
Phenyl salicylate, traceable to primary standards Mettler-Toledo Calibration substance ME 30130598,
94993 Methyltriphenylphosphoniumbromide, traceable to
primary standards (LGC)
• Used to determine the accuracy of instrument and / or Density Standard (15 °C), UKAS ISO/IEC17025 and
DEN1508
procedure of an analytical method ISO 17034 certified, 0.9413 g/mL at 15 °C
• CRMs and Analytical standard grade, tested following ASTM Density Standard (15 °C), UKAS ISO/IEC17025 and
DEN1509
D4052 and ISO 12185 guidelines ISO 17034 certified, 0.9829 g/mL at 15 °C
• Certified according to ISO 17025 / 17034 specifications under Density Standard (15 °C), UKAS ISO/IEC17025 and
DEN1510
UKAS between 15 °C to 150 °C ISO 17034 certified, 1.0269 g/mL at 15 °C
Density Standard (15 °C), UKAS ISO/IEC17025 and
DEN1511
ISO 17034 certified, 1.0695 g/mL at 15 °C
Density Standard (15 °C), UKAS ISO/IEC17025 and
DEN1513
Table 11. Density standards ISO 17034 certified, 1.1963 g/mL at 15 °C
Density Standard (15 °C), UKAS ISO/IEC17025 and
Product DEN1514
Product Name ISO 17034 certified, 1.2878 g/mL at 15 °C
Number
Density Standard (20 °C), UKAS ISO/IEC17025 and
Density Standard, ASTM D 4052; ISO 12185 (0.83294 DEN2001
CRMDEGO ISO 17034 certified, 0.6597 g/mL at 20 °C
g/mL, 15 °C)
Density Standard (20 °C), UKAS ISO/IEC17025 and
Density Standard, ASTM D 4052; IP 365 / ISO 12185 DEN2002
CRMUDEGO ISO 17034 certified, 0.7264 g/mL at 20 °C
(0.8355 g/mL, 15 °C)
Density Standard (20 °C), UKAS ISO/IEC17025 and
Density Standard, ASTM D 4052; ISO 12185 (0.73576 DEN2003
CRMDEGA ISO 17034 certified, 0.7788 g/mL at 20 °C
g/mL, 15 °C)
Density Standard (20 °C), UKAS ISO/IEC17025 and
Density Standard, ASTM D 4052; ISO 12185 (0.7933 DEN2004
CRMDEKR ISO 17034 certified, 0.8383 g/mL at 20 °C
g/mL, 15 °C)
Density Standard (20 °C), UKAS ISO/IEC17025 and
Density Standard (100 °C), UKAS ISO/IEC17025 and DEN2005
DEN10001 ISO 17034 certified, 0.8556 g/mL at 20 °C
ISO 17034 certified, 0.768 g/mL, 100 °C
Density Standard (20 °C), UKAS ISO/IEC17025 and
Density Standard (100 °C), UKAS ISO/IEC17025 and DEN2006
DEN10003 ISO 17034 certified, 0.8708 g/mL at 20 °C
ISO 17034 certified, 0.8541 g/mL, 100 °C
Density Standard (20 °C), UKAS ISO/IEC17025 and
Density Standard (150 °C), UKAS ISO/IEC17025 and DEN2007
DEN15001 ISO 17034 certified, 0.9376 g/mL at 20 °C
ISO Guide 34 certified, 0.7324 g/mL at 150 °C
Density Standard (20 °C), UKAS ISO/IEC17025 and
Density Standard (150 °C), UKAS ISO/IEC17025 and DEN2008
DEN15002 ISO 17034 certified, 0.9817 g/mL at 20 °C
ISO Guide 34 certified, 0.7795 g/mL at 150 °C
Density Standard (20 °C), UKAS ISO/IEC17025 and
Density Standard (150 °C), UKAS ISO/IEC17025 and DEN2009
DEN15003 ISO 17034 certified, 1.0257 g/mL at 20 °C
ISO Guide 34 certified, 0.8277 g/mL at 150 °C
Density Standard (20 °C), UKAS ISO/IEC17025 and
Density Standard (15 °C), UKAS ISO/IEC17025 and DEN2010
DEN1501 ISO 17034 certified, 1.0677 g/mL at 20 °C
ISO 17034 certified, 0.6643 g/mL at 15 °C
Density Standard (25 °C), UKAS ISO/IEC17025 and
Density Standard (15 °C), UKAS ISO/IEC17025 and DEN2507
DEN1503 ISO 17034 certified, 0.9803 g/mL at 25 °C
ISO 17034 certified, 0.8118 g/mL at 15 °C
Density Standard (25 °C), UKAS ISO/IEC17025 and
Density Standard (15 °C), UKAS ISO/IEC17025 and DEN2508
DEN1504 ISO 17034 certified, 1.0242 g/mL at 25 °C
ISO 17034 certified, 0.8118 g/mL at 15 °C
19
Product Product
Product Name Product Name
Number Number
Density Standard (25 °C), UKAS ISO/IEC17025 and Density Standard (60 °C), UKAS ISO/IEC17025 and
DEN2509 DEN6002
ISO 17034 certified, 1.0657 g/mL at 25 °C ISO 17034 certified, 0.8243 g/mL at 60 °C
Density Standard (25 °C), UKAS ISO/IEC17025 and Density Standard (25 °C)UKAS ISO/IEC17025 and ISO
DEN2510 DEN2511
ISO 17034 certified, 1.1233 g/mL at 25 °C 17034 certified, 1.1869 g/mL at 25 °C
Density Standard (20 °C), UKAS ISO/IEC17025 and Density Standard 749 kg/m3, H&D Fitzgerald Ltd.
DEN2012 76081
ISO 17034 certified, 1.1917 g/mL at 20 °C Quality
Density Standard (20 °C), UKAS ISO/IEC17025 and Density Standard 870 kg/m3, H&D Fitzgerald Ltd.
DEN2013 76731
ISO 17034 certified, 1.2849 g/mL at 20 °C Quality
Density Standard (20 °C), UKAS ISO/IEC17025 and Density Standard 1191 kg/m3, H&D Fitzgerald Ltd.
DEN2014 89353
ISO 17034 certified, 1.6226 g/mL at 20 °C Quality
Density Standard (25 °C), UKAS ISO/IEC17025 and Density Standard 998 kg/m3, H&D Fitzgerald Ltd.
DEN2502 12156
ISO 17034 certified, 0.7223 g/mL at 25 °C Quality
Density Standard (25 °C), UKAS ISO/IEC17025 and Density Standard 1623 kg/m3, H&D Fitzgerald Ltd.
DEN2503 15889
ISO 17034 certified, 0.775 g/mL at 25 °C Quality
Density Standard (25 °C), UKAS ISO/IEC17025 and Density Standard 692 kg/m3, H&D Fitzgerald Ltd.
DEN2504 44964
ISO 17034 certified, 0.8349 g/mL at 25 °C Quality
Density Standard (25 °C), UKAS ISO/IEC17025 and Density Standard 1251 kg/m3, H&D Fitzgerald Ltd.
DEN2512 36232
ISO 17034 certified, 1.2819 g/mL at 25 °C Quality
Density Standard (40 °C), UKAS ISO/IEC17025 and
DEN4001
ISO 17034 certified, 0.6415 g/mL at 40 °C
Density Standard (40 °C), UKAS ISO/IEC17025 and
DEN4003
ISO 17034 certified, 0.794 g/mL at 40 °C 11.1 Relative Density Standards
DEN4004
Density Standard (40 °C), UKAS ISO/IEC17025 and Paragon ISO 17025 / ISO 17034 Relative Density
ISO 17034 certified, 0.8247 g/mL at 40 °C
Standards are designed for the calibration or
DEN4005
Density Standard (40 °C), UKAS ISO/IEC17025 and verification of instruments used to measure density
ISO 17034 certified, 0.8706 g/mL at 40 °C
and relative density of materials at the desired test
DEN5001
Density Standard (50 °C), UKAS ISO/IEC17025 and temperature within the range of 15 °C to 25 °C.
ISO Guide 34 certified, 0.787 g/mL at 50 °C
All density measurements are made in accordance
DEN5002
Density Standard (50 °C), UKAS ISO/IEC17025 and with ASTM D1480, for density and relative density
ISO 17034 certified, 0.8269 g/mL at 50 °C (specific gravity).
Density Standard (50 °C), UKAS ISO/IEC17025 and
DEN5003
ISO 17034 certified, 0.8649 g/mL at 50 °C Table 12. Relative Density standards
Density Standard (60 °C), UKAS ISO/IEC17025 and
DEN6001 Product
ISO 17034 certified, 0.796 g/mL at 60 °C Product Name
Number
Density Standard (60 °C), UKAS ISO/IEC17025 and
DEN6003 Relative Density Standard (25 °C), UKAS ISO/
ISO 17034 certified, 0.8675 g/mL at 60 °C
RDEN2501 IEC17025 and ISO 17034 certified, Relative Density
Density Standard (80 °C), UKAS ISO/IEC17025 and 25/4 0.6552 at 25 °C
DEN8001
ISO 17034 certified, 0.7823 g/mL at 80 °C
Relative Density Standard (25 °C), UKAS ISO/
Density Standard (80 °C), UKAS ISO/IEC17025 and RDEN2505 IEC17025 and ISO 17034 certified, Relative Density
DEN8002
ISO 17034 certified, 0.8227 g/mL at 80 °C 25/4 0.8693 at 25 °C
Density Standard (80 °C), UKAS ISO/IEC17025 and Relative Density Standard (25 °C), UKAS ISO/
DEN8003
ISO 17034 certified, 0.8568 g/mL at 80 °C RDEN2503 IEC17025 and ISO 17034 certified, Relative Density
25/4 0.7730 at 25 °C
Pure Water Density Standard, UKAS ISO/IEC17025
DENWAT and ISO Guide 34 certified, 0.9982 g/mL at 20 °C, Relative Density Standard (25 °C), UKAS ISO/
0.9970 g/mL at 25 °C RDEN2504 IEC17025 and ISO 17034 certified, Relative Density
25/4 0.8366 at 25 °C
Pure Water Density Standard, UKAS ISO/IEC17025
DENWAT3 and ISO Guide 34 certified, 0.9982 g/mL at 20 °C, Relative Density Standard (25 °C), UKAS ISO/
0.9970 g/mL at 25 °C RDEN2501 IEC17025 and ISO 17034 certified, Relative Density
25/4 0.6552 at 25 °C
Density Standard, ASTM D 4052; IP 365 / ISO 12185
CRMUDEGA
(0.7377 g/mL, 15 °C) Relative Density Standard (15 °C), UKAS ISO/
RDEN1501 IEC17025 and ISO 17034 certified, Relative Density
Density Standard, ASTM D4052; ISO 12185 (0.79672 15/4 0.6643 at 15 °C
CRMUDEKR
g/mL, 15 °C)
Relative Density Standard (15 °C), UKAS ISO/
Density Standard (100 °C), UKAS ISO/IEC17025 and RDEN1502 IEC17025 and ISO 17034 certified, Relative Density
DEN10002
ISO 17034 certified, 0.8103 g/mL at 100 °C 15/4 0.7186 at 15 °C
Density Standard (40 °C), UKAS ISO/IEC17025 and Relative Density Standard (15 °C), UKAS ISO/
DEN4002
ISO 17034 certified, 0.7097 g/mL at 40 °C RDEN1503 IEC17025 and ISO 17034 certified, Relative Density
Density Standard (15 °C), UKAS ISO/IEC17025 and 15/4 0.7807 at 15 °C
DEN1506
ISO 17034 certified, 0.8628 g/mL at 15 °C Relative Density Standard (15 °C), UKAS ISO/
Density Standard (15 °C), UKAS ISO/IEC17025 and RDEN1504 IEC17025 and ISO 17034 certified, Relative Density
DEN1512 15/4 0.8163 at 15 °C
ISO 17034 certified, 1.1283 g/mL at 15 °C
Density Standard (20 °C), UKAS ISO/IEC17025 and Relative Density Standard (15 °C), UKAS ISO/
DEN2011 RDEN1505 IEC17025 and ISO 17034 certified, Relative Density
ISO 17034 certified, 1.1258 g/mL at 20 °C
15/4 0.8494 at 15 °C
20
Product Product
Product Name Product Name
Number Number
Relative Density Standard (15 °C), UKAS ISO/ Relative Density Standard (20 °C), UKAS ISO/
RDEN1506 IEC17025 and ISO 17034 certified, Relative Density RDEN2002 IEC17025 and ISO 17034 certified, Relative Density
15/4 0.8642 at 15 °C 20/4 0.7145 at 20 °C
Relative Density Standard (15 °C), UKAS ISO/ Relative Density Standard (20 °C), UKAS ISO/
RDEN1507 IEC17025 and ISO 17034 certified, Relative Density RDEN2003 IEC17025 and ISO 17034 certified, Relative Density
15/4 0.8797 at 15 °C 20/4 0.7769 at 20 °C
Relative Density Standard (20 °C), UKAS ISO/ Relative Density Standard (20 °C), UKAS ISO/
RDEN2006 IEC17025 and ISO 17034 certified, Relative Density RDEN2004 IEC17025 and ISO 17034 certified, Relative Density
20/4 0.8723 at 20 °C 20/4 0.8400 at 20 °C
Relative Density Standard (20 °C), UKAS ISO/ Relative Density Standard (20 °C), UKAS ISO/
RDEN2001 IEC17025 and ISO 17034 certified, Relative Density RDEN2005 IEC17025 and ISO 17034 certified, Relative Density
20/4 0.6597 at 20 °C 20/4 0.8452 at 20 °C
• Traceable to SI and higher order standards from NIST TDS1000 Total Dissolved Solids 1000 mg/L Calibration Standard
• Delivered with a certificate of analysis including all information TDS1500 TDS 1500 mg/L Calibration Std
on use of the CRM Total Suspended Solids 1000 mg/L Calibration
TSS1000
Standard
• Assigned value based on a purity determination by mass
balance and gravimetrically prepared value TSS100 Total Suspended Solids 100 mg/L Calibration Standard
TSS10 Total Suspended Solids 10 mg/L Calibration Standard
TSS5 Total Suspended Solids 5 mg/L
See our complete list of total suspended solids:
Total Suspended Solids
21
13. Additional Physical Properties
We have a wide array of physical property standards in our offering that enable
measurements including water hardness, distillation, and fuel testing—namely, aniline
point and freezing point.
Fuel testing and distillation CRMs are suitable to standardize laboratory instruments
used to analyze petroleum and derivatives. Distillation standards are applicable for
distillation at atmospheric pressure following ASTM D86, IP 123, ISO 3405 and other
similar international guidelines. Water hardness standards are employed in the testing
and performance monitoring of hardness instruments.
22
14. Flash Point Standards
We offer certified flash point standards from Paragon Scientific Ltd for
verification of laboratory instruments and routine monitoring of quality of your
petroleum-based products.
Some other common standardized test methods for measuring flash point are Pensky-Martens closed cup (ASTM D93; IP 34), Cleveland Open
Cup (ASTM D92; IP 36), TAG (ASTM D56) and Abel (IP 170, IP 304) closed cup methods.
23
15. Acidity/Total Acid Number (TAN)
Standard
Paragon TAN CRMs are specifically manufactured for the verification of analytical
instruments used to determine acid number by potentiometric titration.
• The manufacture and certification processes are carried out in strict accordance with Paragon Scientific’s dual UKAS accreditations to ISO
17025 & ISO 17034
• This dual accreditation ensures the highest level of accreditation guarantee and provides the most credible certified data
available worldwide.
24
17. Refractive Index Standards
We offer Refractive Index standards CRMs manufactured by Paragon Scientific Ltd.
25
19. Redox Standards
Our redox standards from Reagecon are employed as control standards rather
than calibration standards because redox electrodes do not need calibration. Such
standards not only control the functionality of the sensing and reference electrodes
but also control the analyst's technique, environmental conditions, and the operation
of the measurement meter (pH meter in millivolt (mV) mode).
Table 20. Redox Standards
Features & Benefits
Product
Product Name
• Broad range of values (124 mV – 650 mV) Number
• Detailed Safety Data Sheets available online 04887 Redox standard, 124 mV
• Certified with proven verifiable accuracy and uncertainty 13198 Redox standard, 250 mV
of measurement 40661 Redox standard, 200 mV
80138 Redox standard, 600 mV
87783 Redox standard, 650 mV
Find our complete collection of redox standards:
Redox Standards 78855 Redox standard, 465 mV
For these analyses, we provide CRMs and analytical grade standards as ready-to-use
solutions for calibration purposes and as CRM matrix materials.
26
Product Product
Product Name Product Name
Number Number
COD 500 mg/L Calibration Standard, certified A-2045-040 TOC-Calibration Kit, 25 mg TOC
COD500
reference material
A-2050-040 TOC-Calibration Kit, 50 mg TOC
BOD 1000 mg/L Calibration Standard, certified
BOD1000 BOD Standard, EN 1899 analogous, 190-230 mg/L, 10
reference material 1.00718
1L, Spectroquant®
BOD 2000 mg/L Calibration Standard, certified
BOD2000
reference material
27
Merck KGaA
Frankfurter Strasse 250
64293 Darmstadt, Germany
[Link]
© 2023 Merck KGaA, Darmstadt, Germany and/or its affiliates. All Rights Reserved. Merck, the vibrant M,
BioReliance, Millipore, Milli-Q, SAFC, Sigma-Aldrich, Supelco, Certipur, TraceCert, Titrisol, Titripur, Titripac, and
Aquastar are trademarks of Merck KGaA, Darmstadt, Germany or its affiliates. All other trademarks are
the property of their respective owners. Detailed information on trademarks is available via publicly
accessible resources.