Miniature PCB Relays 10 - 16 A: Series

The document provides specifications for the 45 Series Miniature PCB relays, which are designed for 10 to 16 A applications with options for different contact configurations and coil specifications. It details the technical data, including insulation ratings, ambient temperature ranges, and electrical life for various load types. Additionally, it includes ordering information and outlines the relay types available, such as those with Faston connections and cadmium-free options.

Uploaded by

Alex Ivanov
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
34 views6 pages

Miniature PCB Relays 10 - 16 A: Series

The document provides specifications for the 45 Series Miniature PCB relays, which are designed for 10 to 16 A applications with options for different contact configurations and coil specifications. It details the technical data, including insulation ratings, ambient temperature ranges, and electrical life for various load types. Additionally, it includes ordering information and outlines the relay types available, such as those with Faston connections and cadmium-free options.

Uploaded by

Alex Ivanov
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

45 SERIES 45

Miniature PCB relays 10 - 16 A SERIES

Relay for +105 °C ambient use 45.31…x310 45.31…0610


PCB mount - high contact gap
- 45.31…x310, 1 Pole normally open
(≥ 3 mm contact gap)
- 45.31…0610, 1 Pole normally open
A
(≥ 3.6 mm contact gap)
• Contact gap ≥ 3 mm or ≥ 3.6 mm according to
EN 60730-1
• Sensitive DC coil - 360 mW (45.31…x310 type)
• Cadmium Free contact material
• Reinforced insulation between coil and • 1 NO (SPST-NO), • 1 NO (SPST-NO),
contacts according to EN 60335-1, EN 50178,
≥ 3 mm gap ≥ 3.6 mm gap
EN 60204 with safe separation and 8 mm
• Max ambient temperature • Max ambient temperature
clearance and creepage distance
+105 °C +105 °C
• 6 kV (1.2/50 µs) isolation, coil-contacts
• PCB mounting • PCB mounting
• Flux proof: RT II

45.31…x310 45.31…0610
(1 NO/SPST-NO) (1 NO/SPST-NO)

For outline drawing see page 5

For UL ratings see:


“General technical information” page V Copper side view Copper side view
Contact specification
Contact configuration 1NO (SPST-NO) ≥ 3 mm gap 1NO (SPST-NO) ≥ 3.6 mm gap
Rated current/Maximum peak current A 16/30 10/30
Rated voltage/
Maximum switching voltage V AC 250/400 500/500
Rated load AC1 VA 4000 5000
Rated load AC15 (230 V AC) VA 750 750
Single phase motor rating (230 V AC) kW 0.55 0.55
Breaking capacity DC1: 30/110/220 V A 16/4/1 10/4/1
Minimum switching load mW (V/mA) 500 (10/5) 500 (10/5)
Standard contact material AgNi AgNi
Coil specification
Nominal voltage (UN) V AC (50/60 Hz) — —
V DC 6 - 12 - 24 - 48 - 60 6 - 12 - 24 - 48 - 60
Rated power AC/DC VA (50 Hz)/W —/0.36 —/0.55
Operating range AC — —
DC (0.7…1.2)UN (0.8…1.2)UN
Holding voltage AC/DC —/0.4 UN —/0.4 UN
Must drop-out voltage AC/DC —/0.1 UN —/0.1 UN
Technical data
Mechanical life AC/DC cycles —/10 · 106 —/2 · 106
Electrical life at rated load AC1 cycles 30 · 10 3
10 · 103
Operate/release time  ms 12/2 12/2
Insulation between coil
and contacts (1.2/50 µs) kV 6 (8 mm) 6 (8 mm)
X-2017, [Link]

Dielectric strength
between open contacts V AC 2500 3000
Ambient temperature range °C –40…+105 –40…+105
Environmental protection RT II RT II
Approvals (according to type)

1
45 45 SERIES
SERIES Miniature PCB relays 16 A

Relays for +125 °C ambient use 45.71 45.91


PCB mount - Faston 250 contact connections
- 45.71, 1 Pole normally open or normally
closed
A - 45.91, 1 Pole normally open
(≥ 3 mm contact gap)
• Contact gap ≥ 3 mm according to EN 60730-1
(45.91 type)
• Sensitive DC coil - 360 mW
• Cadmium Free option available
• Reinforced insulation between coil and
contacts according to EN 60335-1, EN 50178, • 1 NO or 1 NC • 1 NO (SPST-NO),
EN 60204 with safe separation and 8 mm (SPST-NO or SPST-NC) ≥ 3 mm gap
clearance and creepage distance • Max ambient temperature • Max ambient temperature
• 6 kV (1.2/50 µs) isolation, coil-contacts +125 °C +125 °C
• Flux proof: RT II standard, (RT III option) • PCB mounting + Faston 250 • PCB mounting + Faston 250

45.71…0310
(1 NO)/(SPST-NO)

45.91…0310
(1 NO/SPST-NO)

45.71…0410
(1 NC)/(SPST-NC)

For outline drawing see page 5

For UL ratings see:


“General technical information” page V Copper side view Copper side view
Contact specification
Contact configuration 1NO or 1NC (SPST-NO or SPST-NC) 1NO (SPST-NO) ≥ 3 mm gap
Rated current/Maximum peak current A 16/30 16/30
Rated voltage/
Maximum switching voltage V AC 250/400 250/400
Rated load AC1 VA 4000 4000
Rated load AC15 (230 V AC) VA 750 750
Single phase motor rating (230 V AC) kW 0.55 0.55
Breaking capacity DC1: 30/110/220 V A 16/0.3/0.13 16/4/1
Minimum switching load mW (V/mA) 500 (10/5) 500 (10/5)
Standard contact material AgCdO AgNi
Coil specification
Nominal voltage (UN) V AC (50/60 Hz) — —
V DC 6 - 12 - 24 - 48 - 60 6 - 12 - 24 - 48 - 60
Rated power AC/DC VA (50 Hz)/W —/0.36 —/0.36
Operating range AC — —
DC (0.7…1.2)UN (0.7…1.2)UN
Holding voltage AC/DC —/0.4 UN —/0.4 UN
Must drop-out voltage AC/DC —/0.1 UN —/0.1 UN
Technical data
Mechanical life AC/DC cycles —/10 · 106 —/10 · 106
Electrical life at rated load AC1 cycles 100 · 10 3
30 · 103
Operate/release time  ms 10/2 12/2
Insulation between coil
and contacts (1.2/50 µs) kV 6 (8 mm) 6 (8 mm)
X-2017, [Link]

Dielectric strength
between open contacts V AC 1000 2500
Ambient temperature range °C –40…+125 –40…+125
Environmental protection RT II RT II
Approvals (according to type)

2
45 SERIES 45
Miniature PCB relays 10 - 16 A SERIES

Ordering information
Example: 4
 5 series for PCB relay + Faston 250, 1 NO (SPST-NO), 12 V DC coil.
A B C D
A
4 5 . 7 1 . 7 . 0 1 2 . 0 3 1 0
Series A: Contact material D: Special versions
0 = S tandard AgCdO 0 = Flux proof (RT II)
Type for 45.71, 1 = Wash tight (RT III) 45.71
3 = PCB mount, ≥ 3 mm or ≥ 3.6 mm Standard AgNi and 45.91 only
contact gap for 45.31 and 45.91
7 = PCB + Faston 250 mount 1 = AgNi C: Options
9 = PCB + Faston 250 mount, ≥ 3 mm 2 = AgCdO 1 = None

No. of poles B: Contact circuit


1 = 1 pole, 16 A 3 = NO (SPST)
4 = NC (SPST) 45.71 only
Coil version 6 = NO (SPST), ≥ 3.6 mm
7 = Sensitive DC
9 = Standard DC (45.31…0610 only)

Coil voltage
See coil specifications

Selecting features and options: only combinations in the same row are possible.

Type Coil version A B C D


sensitive DC 0-2 3 1 0
45.31
standard DC 0 6 1 0
45.71 sensitive DC 0-1 3-4 1 0-1
45.91 sensitive DC 0-2 3 1 0-1

Technical data
Insulation according to EN 61810-1
45.71 45.31 / 45.91
Nominal voltage of supply system V AC 230/400 230/400
Rated insulation voltageV AC 250 400 250 400
Pollution degree 3 2 3 2
Insulation between coil and contact set
Type of insulation Reinforced (8 mm) Reinforced (8 mm)
Overvoltage category III III
Rated impulse voltage kV (1.2/50 µs) 6 6
Dielectric strength V AC 4000 4000
Insulation between open contacts
Type of disconnection Micro-disconnection Full-disconnection
Overvoltage category — III
Rated impulse voltage kV (1.2/50 µs) — 4
Dielectric strength V AC/kV (1.2/50 µs) 1000/1.5 2500/4
Conducted disturbance immunity
Burst (5…50)ns, 5 kHz, on A1 - A2 according to EN 61000-4-4 level 4 (4 kV)
Surge (1.2/50 µs) on A1 - A2 (differential mode) according to EN 61000-4-5 level 3 (2 kV)
Other data 45.71 45.31 / 45.91
Bounce time: NO/NC ms 3/3 2/—
Vibration resistance (10…150)Hz: NO/NC g 20/10 20/—
X-2017, [Link]

Shock resistance g 20
Power lost to the environment without contact current W 0.4
with rated current W 1.8
Recommended distance between relays mounted on PCB mm ≥ 5

3
45 45 SERIES
SERIES Miniature PCB relays 10 - 16 A

Contact specification
F 45 - Electrical life (AC) v contact current F 45 - Electrical life (AC) v contact current
Type 45.71 Type 45.31/45.91
A
Resistive load - cosφ = 1

Resistive load - cosφ = 1


Inductive load - cosφ = 0.4
Cycles

Cycles
H 45 - Maximum DC1 breaking capacity
• When switching a resistive load (DC1) having voltage and current
values under the curve, an electrical life of ≥ 100 · 103 cycles (45.71) and
≥ 30 · 103 cycles (45.31, 45.91) can be expected.
DC breaking current (A)

• In the case of DC13 loads, the connection of a diode in parallel with the
load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.

DC voltage (V)

Coil specifications
DC coil data - 0.36 W sensitive DC coil data - 0.55 W standard
Nominal Coil Operating range Resistance Rated coil Nominal Coil Operating range Resistance Rated coil
voltage code consumption voltage code consumption
UN Umin Umax R I at UN UN Umin Umax R I at UN

V V V Ω mA V V V Ω mA
6 7.006 4.2 7.2 100 60 6 9.006 4.2 7.2 72 83
12 7.012 8.4 14.4 400 30 12 9.012 8.4 14.4 300 40
24 7.024 16.8 28.8 1600 15 24 9.024 16.8 28.8 1150 21
48 7.048 33.6 57.6 6400 7.5 48 9.048 33.6 57.6 4400 11
60 7.060 42 72 10000 6 60 9.060 42 72 7200 8.3

R 45 - DC coil operating range v ambient temperature

limit for 45.31


X-2017, [Link]

1 - Max. permitted coil voltage.


2 - Min. pick-up voltage with coil at ambient temperature.

4
45 SERIES 45
Miniature PCB relays 10 - 16 A SERIES

Outline drawings
Type 45.31 Type 45.71/91

A
X-2017, [Link]

Please see general technical information 5