0% found this document useful (0 votes)
35 views2 pages

Datasheet Tsol RSDM

The document outlines the TSUN Module-Level Rapid Shutdown system, which includes automatic and manual shutdown options for solar panel DC power in emergencies. It details various models of rapid shutdown devices and controllers, including their specifications such as voltage, current, and temperature ranges. The system is designed to ensure safety during high-temperature conditions and includes features for both firefighters and homeowners to manually shut down power as needed.

Uploaded by

Alynne Vcs
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
35 views2 pages

Datasheet Tsol RSDM

The document outlines the TSUN Module-Level Rapid Shutdown system, which includes automatic and manual shutdown options for solar panel DC power in emergencies. It details various models of rapid shutdown devices and controllers, including their specifications such as voltage, current, and temperature ranges. The system is designed to ensure safety during high-temperature conditions and includes features for both firefighters and homeowners to manually shut down power as needed.

Uploaded by

Alynne Vcs
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

TSUN

Module-Level Rapid Shutdown

TSOL-RSDM

Automatic Shutdown Shutdown With Distribution Box


Automatically shutdown the DC power of panels In emergency, firefighters or homeowners can
when detecting temperature of the area is manually turn off the AC power of the distribution
higher than 85℃. box.

Shutdown With Inverter Shutdown With Controller


In emergency, it can be manually turned off by the In emergency, it can be shut down manually
DC switch in the SUNSPEC inverter. through the module-level rapid shutdown controller
RSDM-C.

TSUNESS Co., Ltd


Technical Data

TSOL-RSDM-DD

TSOL-RSDM-DS TSOL-RSDM-CQ

Rapid Shutdown Device

Model TSOL-RSDM-DS TSOL-RSDM-DD


Max. DC Voltage 80V(UL) / 120V(EU) 80V*2(UL) / 120V*2(EU)
Max. DC Current 20A 20A*2
Max. System Voltage 1500V 1500V
Operating Temperature Range -40℃ to +80℃ -40℃ to +80℃
Length of Cable 300mm(Panel), 1200mm(String) 300mm(Panel), 1200mm(String)
Ingress Protection IP68 IP68

Rapid Shutdown Controller

Model TSOL-RSDM-CQ
Operating AC Voltage Range 100 V-240 V
Norminal Frequency 50/60 Hz
Quantity of DC Input 4 Strings
Max. DC Current 20 A
Max. DC Voltage 1500 V
Operating Temperature Range -30℃ to +55℃
Ingress Protection IP65

Diagram

AC Power Supply*

···

4 Strings Input Output

··· Distribution Box


TSOL-RSDM-DS TSOL-RSDM-CQ Inverter
DC
*TSOL-RSDM-CQ could be powered by the EPS output while used AC

AC Power Supply*

···

4 Strings Input Output

··· Distribution Box


TSOL-RSDM-DD TSOL-RSDM-CQ Inverter
DC
AC
*TSOL-RSDM-CQ could be powered by the EPS output while used