0% found this document useful (0 votes)
234 views32 pages

VT Series by Sterling Pump

The Sterling VT series offers a range of Vertical Line Shaft Turbine Pumps from 5" to 20" with flow rates up to 1,500 m³/h, suitable for various applications including irrigation, agriculture, and industrial pumping. The pumps are available in multiple materials and configurations, including electric and diesel-driven options, and are designed for efficient handling of large volumes of liquids. Key features include factory testing, customizable materials, and compatibility with different lubrication systems.

Uploaded by

saikat pumpsense
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
234 views32 pages

VT Series by Sterling Pump

The Sterling VT series offers a range of Vertical Line Shaft Turbine Pumps from 5" to 20" with flow rates up to 1,500 m³/h, suitable for various applications including irrigation, agriculture, and industrial pumping. The pumps are available in multiple materials and configurations, including electric and diesel-driven options, and are designed for efficient handling of large volumes of liquids. Key features include factory testing, customizable materials, and compatibility with different lubrication systems.

Uploaded by

saikat pumpsense
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Line Shaft Turbine Pumps

VT series
5″–20″
Flow range: up to 1,500 m³/h

Including
VT Series Gearbox & Motors

www.sterlingpumps.com.au
VT series
5” through to 18” Line Shaft Turbine Pumps

The Sterling VT series of Vertical Line Shaft Vertical Turbine Pumps are a broad family of engineered pumps offering reliable
and efficient pumping of large volume liquids used for irrigation, agriculture, Oil & Gas, chemicals, fuels, sea water, fire
protection and industrial pumping applications moving liquid from wells, tanks or natural basins.

• 5” up to 55 m³/h
• 6” up to 95 m³/h
• 7” up to 160 m³/h
• 8” up to 280 m³/h
• 10” up to 500 m³/h
• 12” up to 850 m³/h
• 14” up to 1,150 m³/h
• 16” up to 1,000 m³/h
• 18” up to 1,450 m³/h

Material options
• Cast Iron
• 316 Stainless Steel
• Zinc Free Bronze
• Carbon Steel
• Nickel Aluminium Bronze
• Duplex Stainless Steel
• Super Duplex Stainless Steel
• Inconel 625
• Zeron 100

Nomenclature-Ordering
• VT = Series
• 18 = Nominal pump bowl diameter
• CA =…Impeller trims combination
• 1750 =...Nominal speed
• 3 = Number of stages

2
Applications

• Fire Pumps according to AS2041 and NFPA20


• Irrigation
o From rivers
o Dams
o Sumps/pits
• Agricultural
o Flood control
o Lift irrigation
• Condensate Pumps
• Chemical Pumps
• Aviation Fuels
• Mine dewatering
• Mineral processing
• Processing water
• Sea Water Lift Pumps
• Power station cooling water
• Drainage and Sewage pump stations

Features
• All Sterling Pumps are 100% factory tested
• Stainless Steel 431 shafts
• Fluted phenolic resin coated NBR bearings for efficient water lubrication and sand handling
capabilities
• Due to the diverse range of liquids being pumped, operating temperatures and site specifications,
many materials such as elastomers, bearings, impellers and shafts are matched to suit your pumping
application
• Can be supplied fitted with:
o Electric motors: 2, 4 or 8 pole
o Diesel driven pump sets via right angle gearboxes or drive shaft
o Solar power with hybrid inverters
• Fabricated head works and discharge pipework available
o Mild steel, stainless steel or other to suit
• Mixed flow (MX series) available
• Axial flow (AX series) available
• Water lubricated column design (Generally clean water applications)
• Oil lubricated column design with oil drip feeder tank (Usually for sandy or aggressive water
applications)
• Non Reverse Ratchet assembly fitted and high capacity thrust bearings
• Optional inlet screen-strainer in various style

3
Larger Vertical Line Shaft Turbines, 20” up to 90”

The models shown in this brochure represent a general offering of the broad range of Line Shaft Turbine Pumps that
Sterling Pumps manufacture regularly.

Our Vertical Line Shaft Turbine range is also available up to 90” diameter with
flows up to 40,000 m³/h

Line Shaft Column

• Water lubricated
• Oil lubricated
• Carbon steel
• 304 Stainless Steel
• Special materials
• Threaded connections
• Flanged connections
• 3 metre lengths
• 3 metre or 1.5 metre length bearing centres
• 431 SS shafts
• Bronze bearing retainers
• Fluted NBR bearings
• Rubber centraliser for oil tube

4
Electric Motor RA Gearbox Canned Booster
Drive Turbine Drive Turbine Turbine Turbine

Inclined Turbine

Sterling Line Shaft Turbines can be installed to


obtain water from rivers, dams, and large pond
applications. Mounted on fixed foundations, or a
channel or rail type frame to enable the pump to be
raised or lowered into the most efficient water
drawing position.

The inclined design allows for minimal bank and ground


disturbance. The turbine can also be easily removed during
floods or for servicing.

The electric motor or diesel engine can also be mounted above the
high water line or flood levels to maximize usage and minimize any
damage.

As with vertical turbines, an inclined turbine can be electrically driven, or via a


gearbox and diesel engine.

Inclined turbines can utilise either water lube or oil lube column assemblies.

5
VT Technical Data

Discharge
Shaft Shaft Discharge Bowl Bell Oil tube First additional weight weight
Pump Shaft thread Oil tube
Model extension Size Flange Diameter diameter extension stage stage first additional
series Thread T size size OTS
A d Size FL BD B OT length L length SL stage stage
TH

VT-5 125 355mm 1" 1" 4" 4" 125mm - - - 337mm 91mm 22kg 6kg

VT-6 150 355mm 1" 1" 4" 4" 136mm - 125mm 1½" 414.4mm 105.3mm 24kg 7kg

VT-7 180 355mm 1¼" 1¼" 4" 4" 180mm - 125mm 2" 444.0mm 133.6mm 54kg 16kg

VT-8 190 355mm 1¼" 1¼" 6" 6" 190mm - 125mm 2" 500mm 200mm 62kg 19kg

VT-8 200 355mm 1¼" 1¼" 4", 6" 4", 6" 190mm - 125mm 2" 456.5mm 152.5mm 59kg 18.2kg

VT-10 240 355mm 1½" 1½" 6", 8" 6", 8" 238mm - 125mm 2½" 490mm 165.3mm 73kg 34kg

VT-10 250 355mm 1½" 1½" 8" 8" 248mm - 125mm 3" 902mm 222mm 81kg 38kg

VT-12 300R/H 355mm 1¾" 1¾" 8", 10" 8", 10" 295mm 330mm 125mm 3" 923mm 298.5mm 125kg 46kg

VT-12 300GM 355mm 2¾" 1½"- 2¾" 8", 10" 8", 10" 295mm 355mm 125mm 2½" 686mm 268mm 148kg 59kg

15
VT-14 340 355mm 1 /16" - 10" 10" 338mm 406mm 125mm 3" 700mm 228.6mm 227kg 73kg

VT-14 350 355mm 2" - 10", 12" 10", 12" 344mm .-. 125mm 3½" 738mm 313mm 270kg 110kg
10", 12",
VT-16 400 355mm 2¼" - - 394mm 457mm 125mm 3½" 932mm 354mm 295kg 127kg
14"
15
VT-18 450TM 355mm 1 /16" - - 12", 14" 451mm 531mm 125mm 3½" 498mm 368mm 296kg 139kg

VT-18 450NKL 355mm 2" - - 12", 14" 435mm 435mm 125mm 3½" 1040mm 418mm 380kg 180kg

VT-18 450D 355mm 2¼" - - 12'', 14" 440mm 508mm 125mm 3½" 948mm 318mm 318kg 136kg

VT-20 500 355mm 2¼" - - 14", 16" 501mm 563mm 125mm 3½" 1068mm 365.5mm 454kg 193kg

6
Performance Coverage Chart 1000RPM

Performance Coverage Chart 1500RPM

7
Performance Coverage Chart 3000RPM

8
Water Lube Column
Water Lube Column Flanged

Water Lube Column Threaded

Bearing Centres Flanged Threaded


Line Shaft Column Column
(metres) Carbon Steel or 304SS Carbon Steel or 304SS
Size Nominal Size Length
(refer to speed Flange OD
(inches) Diameter (metres) Pipe Pipe Collar OD (mm) Thread
node) (mm)
4” 160 127
Sch 40 CS
1” 6” 3m 3m 1.5m 235 Sch 40 188 8 TPI
Sch 10 SS
8” 270 250

4” 160 127
6” 235 188
Sch 40 CS
1-1¼ 8” 3m 3m 1.5m 270 Sch 40 250 8 TPI
Sch 10 SS
10” 336 295
12” 412 360

6” 235 188
8” 270 250
10” Sch 40 CS 336 295
1-1½ 3m 3m 1.5m Sch 40 8 TPI
12” Sch 10 SS 412 360
14” 440 n/a
16” 580 n/a

6” 235 188
8” 270 250
10” 336 295
Sch 40 CS
1-1¾” 12” 3m 3m 1.5m 412 Sch 40 360 8 TPI
Sch 10 SS
14” 440 n/a
16” 580 n/a
18” 640 n/a

Notes for all column:


Shaft couplings are bronze or 431SS Carbon steel threaded column collar is carbon steel
Bearing retainers are 316SS 304SS threaded column collar is 316SS
Shaft material is 431SS TPI =- Threads Per Inch

Pumps above 2,200 rpm may use 3 metre or 1.5 metre bearing centre column (flanged from February 2019, threaded from
July 2020)
Pumps below 2,200 rpm may use 3 metre bearing centre column
Carbon steel external surfaces are painted in bituminous black paint for corrosion resistance. Threaded columns use industry
standard thread pitch, right hand. Left hand available as an option

Subject to change with continuous improvement. If critical, confirm with Sterling Pumps

9
Oil Lube Column
Oil Lube Column Flanged

Oil Lube Column Threaded

Column Flanged Threaded


Line Shaft Oil Lube Column Bearing
Nominal Carbon Steel or 304SS Carbon Steel or 304SS
Size Tube Length Centres
Size Flange OD Collar OD
(inches) (inches) (metres) (metres) Pipe Pipe Thread
Diameter (mm) (mm)
4” 160 127
Sch 40 CS
1” 2” 6” 3m 1.5m 235 Sch 40 188 8 TPI
Sch 10 SS
8” 270 250

4” 160 127
6” 235 188
Sch 40 CS
1-1¼ 2” 8” 3m 1.5m 270 Sch 40 250 8 TPI
Sch 10 SS
10” 336 295
12” 412 360

6” 235 188
8” 270 250
10” Sch 40 CS 336 295
1-1½ 2-2½” 3m 1.5m Sch 40 8 TPI
12” Sch 10 SS 412 360
14” 440 n/a
16” 580 n/a

6” 235 188
8” 270 250
10” 336 295
Sch 40 CS
1-1¾” 3” 12” 3m 1.5m 412 Sch 40 360 8 TPI
Sch 10 SS
14” 440 n/a
16” 580 n/a
18” 640 n/a

Notes for all column:


Shaft couplings are steel or 431SS Carbon steel threaded column collar is carbon steel
Bearing are bronze 304SS threaded column collar is 316SS/bronze
Shaft material is 431SS TPI =- Threads Per Inch

For vertical installations, install Oil Tube Stabiliser (centraliser) at least one (1) every 12 metres.
For inclined/angled installations, install Oil Tube Stabiliser (centraliser) every 3 metres
Carbon steel column and Oil Tube external surfaces are painted in bituminous black paint for corrosion resistance.
Threaded columns use industry standard thread pitch, right hand. Left hand available as an option

Subject to change with continuous improvement. If critical, confirm with Sterling Pumps

10
Conversion Charts
Multiplier Unit Volume Flow Rate - Capacity
1 m³/h 5 10 20 30 40 50 60 70 80 90
24 m³/day 120 240 480 720 960 1,1200 1,440 1,680 1,920 2,160
0.277778 L/S 1.4 2.8 5.6 803 11.1 13.9 16.7 19.4 22.2 25.0
16.6667 LPM 83 167 333 500 667 833 1,000 1,167 1,333 1,500
3.66615 IGPM 18 37 73 110 147 183 220 257 293 330
4.40287 USGPM 22 44 88 132 176 220 264 308 352 396
0.001 ML/hr 0.005 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09
0.024 ML/day 0.12 0.24 0.48 0.72 0.96 1.2 1.44 1.68 1.92 2.16

Multiplier Unit Volume Flow Rate - Capacity


1 m³/h 100 200 300 400 500 600 700 800 900 1,000
24 m³/day 2,400 4,800 7,200 9,600 12,000 14,400 16,800 19,200 21,600 24,000
0.277778 L/S 27.8 55.6 83.3 111.1 138.9 166.7 194.4 222.2 250.0 277.8
16.6667 LPM 1,667 3,333 5,000 6,667 8,333 10,000 11,667 13,333 15,000 16,667
3.66615 IGPM 367 733 1,100 1,466 1,833 2,200 2,566 2,933 3,300 3,666
4.40287 USGPM 440 881 1,321 1,761 2,201 2,642 3,082 3,522 3,963 4,403
0.001 ML/hr 0.1 0.2 0.32 0.4 0.5 0.6 0.7 0.8 0.9 1
0.024 ML/day 2.4 4.8 7.2 9.6 12 14.4 16.8 19.2 21.6 24

Multiplier Unit Volume Flow Rate - Capacity


1 m³/h 1,100 1,200 1,400 1,600 1,800 2,000 2,500 3,000 3,500 4,000
24 m³/day 26,400 28,800 33,600 38,400 43,200 48,000 60,000 72,000 84,000 96,000
0.277778 L/S 306 333 389 444 500 556 694 833 972 1,111
16.6667 LPM 18,333 20,000 23,333 26,667 30,000 33,333 41,667 50,000 58,333 66,667
3.66615 IGPM 4,033 4,399 5,133 5,866 6,599 7,332 9,165 10,998 12,832 14,665
4.40287 USGPM 4,843 5,283 6,164 7,045 7,925 8,806 11,007 13,209 15,410 17,611
0.001 ML/hr 1.1 1.2 1.4 1.6 1.8 2 2.5 3 3.5 4
0.024 ML/day 26.4 28.8 33.6 38.4 43.2 48 60 72 84 96

Multiplier Unit Pressure


1 PSI 10 20 30 40 50 75 100 125 150 200
6.89476 kPa 69 138 207 276 345 517 689 862 1,034 1,379
0.0689476 Bar 0.7 1.4 2.1 2.8 3.4 5.2 6.9 8.6 10.3 13.8
7.032496 m Head 70 141 211 281 352 527 703 879 1,055 1,406
23.066587 Ft Head 231 461 692 923 1,153 1,730 2,307 2,883 3,460 4,613

Multiplier Unit Pressure


1 PSI 250 300 350 400 450 550 600 650 700 750
6.89476 kPa 1,724 2,068 2,413 2,758 3,103 3,792 4,137 4,482 4,826 5,171
0.0689476 Bar 17.2 20.7 24.1 27.6 31.0 37.9 41.4 44.8 48.3 51.7
7.032496 m Head 1,758 2,110 2,461 2,813 3,165 3,868 4,219 4,571 4,923 5,274
23.066587 Ft Head 5,767 6,920 8,073 9,227 10,380 12,687 13,840 14,993 16,147 17,300

11
Minimum Submergence
A submersible borehole/well pump must be submerged at all times.

The pump suction intake must be sufficiently submerged to prevent cavitation and avoid the formation of vortexes
being created on the liquid being pumped.

When a vortex forms, this can cause air to mix with the water being pumped, causing possible cavitation and reduce the
pump capacity and can lead to internal damage of the impellers and bowls.
To avoid free surface vortex formation, you would use the minimum submergence figure recommended by the
manufacturer in their charts.

An approximate way to determine the submergence value for a submersible turbine pumps can be based from the
NPSH curve;

Identify the flow rate you require and go up the graph to the NPSH curve/line.

Examples:
At the nominal flow rate of 80 m³/h the NPSH is 3 metres.

Now use the 3 metres and subtract atmospheric pressure of 9.81 metres. The result is a negative figure which is not
acceptable for a pump intake.

NPSH(M) - G(M) + 1M = minimum submergence


NPSHr = Net Positive Suction Head required. G = head of atmospheric pressure. M = metre
If the value calculated is less than zero metres, for our submersible pumps we would recommend a minimum
submergence 'Y' of 1 metre.

If the value calculated is above zero, use that figure and add 1 metre

Example: If the NPSH curve shows 12 metres, subtract 9.81 metres which equals 2.2 metres, so the recommended
minimum submergence 'Y' would be 3.2 metres. In our charts we would likely state 'Y' as being 3.5 or even 4 metres.

Note:
Minimum submergence is considered from the bottom of the suction strainer for submersible pumps and from the
bottom of the suction bell for vertical line shaft turbine pumps.

12
Friction Loss Chart for Standard Pipe Column
Loss of Head in Meters per 30 Metres of Column
76mm 100mm 125mm 150mm 200mm 250mm 300mm
Column Size
3” 4” 5” 6” 8” 10” 12”
Tube Size mm 32 32 38 50 32 38 50 38 50 64 38 50 64 50 64 76 89 50 64 76 89
Shaft Size mm 19 19 25 32 19 25 32 25 32 38 25 32 38 32 38 45 50 32 38 45 50
1 0.22
2 0.63 0.23
3 1.3 0.17 0.24 0.48
4 2.25 0.29 0.40 0.8 0.11
5 3.25 0.43 0.4 1.2 0.12 0.17
6 4.75 0.62 0.85 1.7 0.15 0.18 0.25
7 6.3 0.82 1.12 2.3 0.2 0.24 0.34 0.14
8 1.04 1.44 2.9 0.25 0.31 0.43 0.13 0.18
9 1.28 1.75 3.6 0.31 0.38 0.52 0.12 0.13 0.23
10 1.52 2.1 4.3 0.37 0.45 0.63 0.145 0.19 0.27
12 2.2 3 5.9 0.53 0.64 0.88 0.19 0.27 0.38
14 2.8 3.8 0.67 0.81 1.13 0.27 0.35 0.49
16 3.5 4.8 0.85 1.04 1.45 0.34 0.44 0.62
18 4.4 1.1 1.3 1.8 0.42 0.55 0.77 0.12
20 5.5 1.3 1.6 2.3 0.53 0.67 0.96 0.15
22 1.6 1.9 2.7 0.63 0.8 1.03 0.15 0.18
24 1.8 2.3 3.2 0.73 0.95 1.33 0.17 0.21
26 2.1 2.6 3.6 0.83 1.08 1.52 0.11 0.2 0.24
Litres Per Second

28 2.4 2.9 4 0.94 1.2 1.73 0.13 0.23 0.28


30 2.7 3.25 4.6 1.05 1.37 1.95 0.14 0.26 0.32 0.11
35 3.5 4.25 6 1.4 1.8 2.6 0.19 0.34 0.41 0.12 0.15
40 4.6 5.5 1.8 2.35 3.3 0.25 0.43 0.54 0.12 0.15 0.19
45 5.6 2.2 2.85 4.1 0.31 0.53 0.65 0.13 0.15 0.19 0.23
50 2.7 3.4 4.8 0.37 0.64 0.78 0.16 0.19 0.23 0.29 0.09
60 3.7 4.75 0.51 0.86 0.107 0.23 0.26 0.32 0.39 0.11 0.13
70 4.8 0.66 1.14 1.4 0.3 0.35 0.42 0.52 0.12 0.13 0.16 0.18
80 0.88 1.5 1.88 0.39 0.41 0.55 0.68 0.15 0.17 0.2 0.23
90 1.08 1.84 2.3 0.48 0.55 0.67 0.83 0.19 0.21 0.25 0.28
100 1.28 2.24 2.7 0.58 0.65 0.79 1 0.23 0.25 0.3 0.35
120 1.77 3.1 3.7 0.79 0.89 1.1 1.4 0.32 0.35 0.4 0.47
140 2.4 4.1 5 1.05 1.2 1.46 1.8 0.42 0.46 0.54 0.63
160 3 5.1 1.32 1.5 1.86 2.3 0.53 0.59 0.68 0.78
180 3.7 6.2 1.64 1.8 2.3 2.8 0.65 0.71 0.83 0.96
200 4.4 1.95 2.2 2.7 3.4 0.77 0.85 1 1.1
225 5.4 2.4 2.8 3.4 4.2 0.95 1.1 1.2 1.4
250 3 3.4 4.1 5.1 1.2 1.3 1.5 1.8
300 4.2 4.7 5.8 1.7 1.8 2.2 2.5
350 5.6 6.2 2.3 2.5 2.9 3.3
400 7.3 2.9 3.2 3.7 4.3

Notes: For open line shaft column friction losses use above figures corresponding to the tube size used for enclosed
shaft.
For data on column sizes over 300mm diameter, refer to Sterling Pumps

Multiply
To convert: l/s 60 lpm
l/s 3.6 m3/h

13
Shaft Rating Curves
Before using the charts, you need to calculate the total down
thrust. This includes hydraulic thrust, line shaft weight and the
weight of the bowls, shaft and impellers. Weight of bowls, shaft
and impeller values can be negligible.

Having calculated the total thrust, the maximum shaft loading can
be taken from the chart, using the applicable RPM chart.

An example:
Speed = 2900 rpm
Thrust = 3000kg
Shaft = 38mm diameter
Using the chart, the maximum load would be 205 kW

An example:
Speed = 2900 rpm
Thrust 2000kg
kW required = 55 kW at bowls
Using the chart, the correct shaft size will be 25mm as the loading exceeds the allowable for the 20mm shaft but is less
than the allowable for the 25mm shaft.

For different shaft materials, apply the following multipliers:

Material Multiplier
AISI C1045 HTS 1.0
431 Stainless Steel 1.0
416 Stainless Steel 0.9
316 Stainless Steel 0.8

Shaft Friction Loss in kW


Shaft Size (mm)
RPM
20 25 32 38 45 50 57 64 70 76 82
1460 0.19 0.32 0.48 0.75 0.93 1.3 1.6 1.9 2.2 2.7 3.1
1770 0.24 0.4 0.56 0.93 1.1 1.5 1.8 2.2 2.6 3.2
2200 0.30 0.5 0.75 1.1 1.4 1.8 2.2 2.6
2900 0.39 0.66 0.95 1.4 1.8
3500 0.46 0.82 1.1

Shafting and Tubing Weights – kg per linear metre (m)


Shaft
Diam. 20 25 32 38 45 50 57 64 70 76 82
(mm)
kg/m 2.23 3.97 6.21 8.94 12.2 15.9 20.1 23.6 30.1 34.3 42

Tube
Diam. 32 38 50 64 76 76 89 102 125 125 125
(mm)
kg/m 4.45 5.4 7.47 11.4 15.3 15.3 18.6 22.3 30.9 30.9 30.9

14
Shaft Rating Curves
Shaft diameters in millimetres (mm)

Solid line curves: bottom and left scale


Dash line curves: top and right scale

Solid line curves: bottom and left scale


Dash line curves: top and right scale

15
Column & Tube Elongation Chart
Millimetres (mm) elongation per 30 metres of column
Column Diameter millimetres (inches)
Hydraulic Thrust
80mm 100mm 125mm 150mm 200mm 250mm 300mm
kg
3” 4” 5” 6” 8” 10” 12”
100 0.07 0.05 0.04 0.03
200 0.15 0.11 0.09 0.06
300 0.22 0.16 0.13 0.09 0.06
400 0.29 0.21 0.17 0.13 0.09
500 0.36 0.27 0.21 0.16 0.12 0.06
600 0.44 0.32 0.25 0.19 0.13 0.08
700 0.51 0.37 0.30 0.23 0.15 0.09 0.09
800 0.58 0.43 0.34 0.26 0.17 0.11 0.10
900 0.66 0.48 0.38 0.29 0.19 0.12 0.11
1,000 0.73 0.53 0.42 0.32 0.21 0.14 0.12
1,200 0.88 0.64 0.51 0.39 0.26 0.18 0.15
1,400 1.02 0.75 0.59 0.45 0.30 0.21 0.18
1,600 1.17 0.86 0.35 0.52 0.34 0.24 0.20
1,800 1.31 0.96 0.76 0.58 0.38 0.27 0.23
2,000 1.46 1.07 0.85 0.64 0.43 0.31 0.25
2,250 1.20 0.95 0.72 0.48 0.34 0.28
2,500 1.34 1.06 0.81 0.53 0.38 0.31
2,750 1.47 1.16 0.89 0.59 0.42 0.34
3,000 1.60 1.27 0.97 0.64 0.46 0.37
3,250 1.38 1.05 0.70 0.50 0.41
3,500 1.48 1.13 0.75 0.53 0.44
3,750 1.59 1.21 0.80 0.57 0.47
4,000 1.69 1.29 0.86 0.61 0.50
4,500 1.90 1.45 0.96 0.69 0.56
5,000 1.61 1.07 0.76 0.62
5,500 1.77 1.18 0.84 0.69
6,000 1.93 1.28 0.91 0.75
6,500 2.09 1.39 0.99 0.81
7,000 2.25 1.50 1.07 0.87
8,000 1.71 1.22 1.00
9,000 1.92 1.37 1.12
10,000 2.14 1.52 1.25
11,000 2.35 1.68 1.37
12,000 2.56 1.83 1.50
13,000 1.98 1.62
14,000 2.13 1.75
15,000 2.29 1.87
16,000 2.44 2.00
18,000 2.74 2.25
20,000 2.50
32 38 38 50 64 76 90
Enclosing Tube Diameter (mm)

Figures are shown based on standard pipe column and enclosing tube with nominal ID.
For open line shaft column multiply value by 1.3

Downthrust due to the hydraulic thrust of the pump causes the shaft and column to
stretch after the pump is in operation.
e = L x 1000 x HT x 9.8
Unless the impellers can be and are raised off the bottom of the bowls enough to E x CSA
allow for this stretch plus some running clearances, the impellers will rub, causing e = Elongation (mm)
L = Shaft Length (m)
the pump to wear and increase kW power required.
E = Modulas of Elast. (200 x 103 Mpa)
With the total hydraulic downthrust known and the Column Elongation determined
HT = Hydraulic Thrust (kg)
from this chart, the total stretch of the column shaft for the setting in question can CSA = Cross Section Area (mm)
be determined.
To find the net elongation subtract from shaft elongation the column elongation

16
Shaft Elongation Chart
Millimetres (mm) elongation per 30 metres of shaft

Hydraulic Shaft Diameter millimetres (inches)


Thrust 20mm 25mm 32mm 38mm 45mm 50mm 57mm 64mm 70mm 76mm 82mm
kg ¾” 1” 1¼” 1½” 1¾” 2” 2¼ 2½” 2¾” 3” 3¼”
100 0.52 0.29 0.19 0.13 0.09 0.07 0.06
200 1.02 0.58 0.38 0.26 0.19 0.15 0.12 0.09
300 1.55 0.87 0.57 0.39 0.28 0.22 0.17 0.14 0.12
400 2.07 1.16 0.75 0.52 0.38 0.29 0.23 0.19 0.15 0.13
500 2.58 1.45 0.94 0.55 0.47 0.36 0.29 0.23 0.19 0.16 0.14
600 3.1 1.74 1.13 0.77 0.57 0.44 0.34 0.29 0.23 0.19 0.17
700 3.61 2.04 1.32 0.90 0.66 0.51 0.40 0.33 0.27 0.23 0.19
800 4.13 2.33 1.51 1.03 0.76 0.58 0.46 0.37 0.31 0.26 0.22
900 4.65 2.62 1.70 1.16 0.85 0.65 0.52 0.42 0.35 0.29 0.25
1,000 5.16 2.91 1.89 1.29 0.95 0.73 0.57 0.47 0.38 0.32 0.28
1,200 6.42 3.49 2.26 1.55 1.14 0.87 0.69 0.56 0.46 0.39 0.33
1,400 4.07 2.64 1.81 1.32 1.02 0.80 0.65 0.54 0.45 0.39
1,600 4.65 3.02 2.07 1.52 1.16 0.92 0.74 0.61 0.52 0.44
1,800 5.23 3.40 2.32 1.71 1.31 1.03 0.84 0.69 0.58 0.50
2,000 5.82 3.77 2.58 1.90 1.45 1.15 0.93 0.77 0.65 0.55
2,250 6.54 4.24 2.90 2.13 1.63 1.29 1.05 0.86 0.73 0.62
2,500 4.72 3.22 2.37 1.81 1.43 1.16 0.96 0.81 0.69
2,750 5.19 3.55 2.61 2.00 1.58 1.28 1.06 0.89 0.76
3,000 5.66 3.87 2.84 2.18 1.72 1.39 1.15 0.97 0.83
3,250 6.13 4.20 3.08 2.36 1.86 1.51 1.25 1.05 0.89
3,500 6.60 4.51 3.32 2.54 2.01 1.63 1.34 1.13 0.96
3,750 4.84 3.56 2.72 2.15 1.74 1.44 1.21 1.03
4,000 5.16 3.79 2.90 2.29 1.86 1.54 1.29 1.10
4,500 5.81 4.27 3.27 2.58 2.09 1.73 1.45 1.24
5,000 6.45 4.74 3.63 2.67 2.32 1.92 1.61 1.38
5,500 5.21 4.00 3.16 2.56 2.11 1.78 1.51
6,000 5.69 4.36 3.44 2.79 2.30 1.94 1.65
6,500 6.16 4.72 3.73 3.02 2.50 2.10 1.79
7,000 6.64 5.08 4.02 3.25 2.69 2.26 1.93
8,000 5.81 4.59 3.71 3.07 2.59 2.20
9,000 6.53 5.16 4.18 3.46 2.90 2.48
10,000 5.74 4.65 3.84 3.23 2.75
11,000 6.31 5.11 4.22 3.55 3.02
12,000 5.58 4.61 3.87 3.30
13,000 6.04 5.00 4.20 3.57
14,000 6.51 5.38 4.52 3.85
15,000 5.76 4.84 4.12
16,000 6.14 5.16 4.40
18,000 5.81 4.95
20,000 6.45 5.50

Figures are shown based on grade CS 1040 carbon steel.


For grades of 300 series stainless steel multiply value by 1.3

Downthrust due to the hydraulic thrust of the pump causes the shaft and column to
stretch after the pump is in operation.
e = L x 1000 x HT x 9.8
Unless the impellers can be and are raised off the bottom of the bowls enough to E x CSA
allow for this stretch plus some running clearances, the impellers will rub, causing e = Elongation (mm)
L = Shaft Length (m)
the pump to wear and increase kW power required.
E = Modulas of Elast. (200 x 103 Mpa)
With the total hydraulic downthrust known and the shaft elongation determined
HT = Hydraulic Thrust (kg)
from this chart, the total stretch of the column shaft for the setting in question can CSA = Cross Section Area (mm)
be determined.
To find the net elongation subtract from shaft elongation the column elongation

17
For Performance Curves – please visit:
www.sterlingpumps.com.au

18
Right Angle Pump Drive
Model Designation:
The model number designates the basic horsepower rating at 1760 RPM pump speed.
The number is preceded by one of the following letter designations to define the type of drive:

• SL Standard Hollow Shaft Drive with Opposed Thrust Capacity


• S Standard Hollow Shaft Drive with Standard Thrust Capacity
• SH Standard Hollow Shaft Drive with Heavy Thrust Capacity

Efficiency:
Through the use of high quality gears and bearings, transmission efficiency ranges from 94% to 98% varying with speed,
horsepower and thrust. Actual efficiency values will be furnished upon request.

Gears:
All drives are furnished with spiral bevel gears, designed in accordance with AGMA (American Gear Manufacturers
Association) standards for both strength and surface durability, employing a minimum service factor of 1.50 at rated
horsepower.

Ratio Selection
Refer to Sterling Pumps for Ratio Availability
(speeds shown are for nominal ratios. Actual ratios may vary by up to 3%)

Vertical Speed Increasers – Ratio & Input Speed


Shaft
1:1 10:11 5:6 4:5 3:4 2:3 4:7 1:2 1:3
RPM
720 720 655 600 576 540 480 411 360 240
870 870 791 725 696 653 580 497 435 290
960 960 873 800 768 720 640 549 480 320
1160 1160 1055 967 928 870 773 663 580 387
1460 1460 1327 1217 1168 1095 973 834 730 487
1760 1760 1600 1467 1408 1320 1173 1006 880 587
3460 3460 3145 2883 2768 2595 2307 1977 1730 1153

Vertical Speed Decreasers – Ratio & Input Speed


Shaft
11:1 6:5 5:4 4:3 3:2 7:4 2:1 5:2 3:1
RPM
720 792 864 900 960 1080 1260 1440 1800 2160
870 957 1044 1088 1160 1305 1523 1740 2175 2610
960 1056 1152 1200 1280 1440 1680 1920 2400 2880
1160 1276 1392 1450 1547 1740 2030 2320 2900 3480
1460 1606 1752 1825 1947 2190 2555 2920 3650 -
1760 1936 2112 2200 2347 2640 3080 3520 - -

19
Horsepower & Thrust Ratings
Vertical Downthrust Capacity in kg Vertica Downthrust Capacity in kg
Shaft H.P. Type SL Type S Type SH l Shaft HP Type SL Type S Type SH
Model Model
Speed Rating Speed Rating
Min Max Min Max Min Max Min Max Min Max Min Max
(RPM) (RPM)
1160 22 0 445 362 1072 362 1673 720 162 0 7977 0 10125
30 1460 26 0 410 345 988 345 1542 960 195 0 7209 0 9150
1760 30 0 386 318 932 318 1455 300 1160 225 0 6795 0 8625
1160 30 0 680 517 2091 517 3136 1460 264 0 6264 0 7950
40 1460 35 0 626 480 1927 480 2891 1760 300 0 5909 0 7500
1760 40 0 591 455 1818 455 2727 720 187 0 7977 0 10125
960 39 0 943 677 2828 677 3882 960 229 0 7209 0 9150
1160 45 0 889 646 2666 646 3659 350 1160 261 0 6795 0 8625
60A
1460 53 0 819 605 2457 605 3373 1460 307 0 6264 0 7950
1760 60 0 773 568 2318 568 3182 1760 350 0 5909 0 7500
960 52 0 1775 948 3438 948 5102 720 241 0 3682 2105 11659 2105 15341
1160 60 0 1673 905 3241 905 4809 960 294 0 3327 1898 10536 1898 13864
80A
1460 70 0 1542 839 2987 839 4433 450A 1160 336 0 3136 1809 9932 1809 13068
1760 80 0 1455 795 2818 795 4182 1460 395 0 2891 1688 9155 1688 12045
960 65 0 1775 948 3438 948 5102 1760 450 0 2727 1591 8636 1591 11364
1160 75 0 1673 905 3241 905 4809 720 267 0 3682 2520 12886 2520 16568
100A
1460 88 0 1542 844 2987 844 4433 960 327 0 3327 2275 11645 2275 14973
1760 100 0 1455 795 2818 795 4182 500A 1160 373 0 3136 2172 10977 2172 14114
960 82 0 2274 1215 3715 1215 5767 1460 439 0 2891 2025 10118 2025 13009
1160 93 0 2143 1167 3502 1167 5436 1760 500 0 2727 1909 9545 1909 12273
125A
1460 115 0 1975 1085 3228 1085 5011 720 321 0 4909 2700 16568 2700 19636
1760 125 0 1864 1023 3045 1023 4727 960 393 0 4436 2438 14973 2438 17745
720 80 0 3068 1620 5032 1620 7732 600A 1160 448 0 4182 2328 14114 2328 16727
960 98 0 2773 1470 4547 1470 6987 1460 526 0 3855 2170 13009 2170 15418
150A 1160 112 0 2614 1403 4286 1403 6586 1760 600 0 3636 2045 12273 2045 14545
1460 132 0 2409 1302 3951 1302 6071 720 401 0 4909 3000 16568 3000 20557
1760 150 0 2273 1227 3727 1227 5727 870 458 0 4582 2808 15464 2808 19186
720 108 0 3068 1620 5523 1620 8284 750A 960 491 0 4436 2711 14973 2711 18577
960 130 0 2773 1463 4991 1463 7486 1160 560 0 4182 2589 14114 2589 17511
200A 1160 150 0 2614 1396 4705 1396 7057 1460 658 0 3855 2411 13009 2411 16141
1460 176 0 2409 1302 4336 1302 6505 1760 750 0 3636 2273 12273 2273 15227
1760 200 0 2273 1227 4091 1227 6136 720 535 0 4909 3000 16568 3000 20557
720 134 0 7955 0 10125 870 811 0 4582 2808 15464 2808 19186
960 165 0 7209 0 9150 1000G 960 654 0 4436 2711 14973 2711 18577
250 1160 187 0 6795 0 8625 1160 747 0 4182 2589 14114 2589 17511
1460 219 0 6264 0 7950 1460 877 0 3855 2411 13009 2411 16141
1760 250 0 5909 0 7500

Table of Dimensions Standard Drive (inches)


Standard Coupling Dimensions (inches)
Nominal Actual GIB Keyway BY BZ XL
¾ 0.751 3/ x 3/32 ¼ - 20 13/8 9/
16 32
7/ 0.876 ¼ x 1/8 ¼ - 20 13/8 9/
8 32
1 1.001 ¼ x 1/8 ¼ - 20 13/8 9
/32
13/16 1.188 ¼ x 1/8 ¼ - 20 1¾ 9/
32
¼ Keyway
1¼ 1.251 ¼ - 20 1¾ 9/
by special 32
request
1¼ 1.251 3/ x 3/16 ¼ - 20 1¾ 9/
8 32
17/16 1.438 3/ x 3/16
8 ¼ - 20 21/8 9/
32
1½ 1.501 3/ x 3/ ¼ - 20 21/8 9/
8 16 32
111/16 1.688 3/ x 3/
8 16 ¼ - 20 2½ 9/
32
3
1¾ 1.751 /8 x 3/16 ¼ - 20 2½ 9
/32
115/16 1.938 ½x¼ ¼ - 20 2½ 9/
32
2 2.001 ½x¼ ¼ - 20 2½ 9/
32
23/16 2.188 ½x¼ 3/ - 16
8 3¼ 9/
32
2¼ 2.251 ½x¼ 3/ - 16 3¼ 9/
8 32
27/16 2.438 5/ x 5/
8 16
3/ - 16
8 3¼ 9/
32
2½ 2.501 5/ x 5/ 3/ - 16 3¼ 9/
8 16 8 32
211/16 2.688 5
/8 x 5/16 3
/8 - 16 3¾ 9
/32
2¾ 2.751 5/ x 5/ 3/ - 16 3¾ 9/
8 16 8 32
215/16 2.938 ¾ x 3/8 3/ - 16
8 3¾ 7/
16

20
Table of Dimensions Standard Drive (inches)
Horizontal Shaft U Type SL Type S Type SH

Model D N AJ AK BB
Nominal Actual Keyway AG CD AG CD AG CD

30 6¾ 25/8 1¼ 1.249 5/ 5
16 x /32 16¼ 13¾ 16¼ 13¾ 17¼ 14¾ 91/8 8.250 3/
16
40A 8½ 43/8 1½ 1.499 3/ x 3/
8 16 21¾ 18 21¾ 18 23 19¼ 91/8 8.250 ¼
40B 8½ 43/8 1½ 1.499 3/ x 3/
8 16 21¾ 18 21¾ 18 23 19¼ 14¾ 13.500 ¼
60A 11½ 4¼ 1½ 1.499 3/ x 3/ 28 235/16 28 235/16 29¼ 249/16 14¾ 13.500 ¼
8 16
80A 11½ 4¼ 17/8 1.874 3
/8 x 3/16 29¼ 249/16 28 235/16 293/8 2411/16 14¾ 13.500 ¼
100A 11½ 4¼ 17/8 1.874 3
/8 x 3/16 29¼ 249/16 28 235/16 293/8 2411/16 14¾ 13.500 ¼
125A 11½ 4¼ 17/8 1.874 3/ x 3/
8 16 29¼ 249/16 29¾ 249/16 293/8 2411/16 14¾ 13.500 ¼
150A 11½ 4½ 27/16 2.436 5/ x 5/
8 16 293/8 251/8 293/8 251/8 311/8 26 14¾ 13.500 ¼
200A 13¾ 5¼ 27/16 2.436 5/ x 5/
8 16 3411/16 303/16 3411/16 303/16 355/16 3013/16 18¼ 13.500 ¼
250 13¾ 5¼ 215/16 2.936 ¾ x 3/8 - - 3411/16 303/16 365/16 3113/16 18¼ 13.500 ¼
*300 13¾ 5¼ 215/16 2.936 ¾ x 3/8 - - 3411/16 303/16 365/16 3113/16 18¼ 13.500 ¼
*350 13¾ 5¼ 215/16 2.936 ¾ x 3/8 - - 3411/16 303/16 365/16 3113/16 18¼ 13.500 ¼
450A 16 6 215/16 2.936 ¾ x 3/8 427/8 367/8 43¼ 38 45¾ 38¼ 23 13.500 ¼
500A 16 6 31/8 3.124 ¾ x 3/8 427/8 367/8 43¼ 38 45¾ 38¼ 23 13.500 ¼
600A 16 6 3¾ 3.749 7/ x 7/ 427/8 367/8 43¼ 38 45¾ 38¼ 23 13.500 ¼
8 16
750A 18 6 3¾ 3.749 7/ x 7/ 48 413/8 50 42 50 429/16 23 13.500 ¼
8 16
1000G 21 8 4 3.998 1 x 1½ 62¼ 50¼ 62¼ 50¼ 62¼ 50¼ 28¾ 22.000 ¼

Model BD BE BF XA XB XC XD XE XF XG XH XJ XK XV XW ** BX Max.

5 7
30 10 /8 /16 107/8 - 0 15/16 3
/8 3
/8 5
/16 - - - - - 1
40A 12 13/ 7/ 155/8 - 0 1¾ ½ ½ 1¼ 2 2¼ 3/ 0 63/8 1¼
16 16 8
40B 16½ 13/ 11/ 155/8 - 0 1¾ ½ ½ 1¼ 2 2¼ 3/ 0 63/8 1¼
16 16 8
60A 16½ ¾ 11/ 16¾ - 0 2 ¾ ¾ 15/8 3 2 3/ 37/8 4¼ 1½
16 8
80A 16½ ¾ 11/ 16¾ - 0 2 ¾ ¾ 15/8 3 2 3/ 37/8 4¼ 1½
16 8
100A 16½ ¾ 11/ 16¾ - 0 2 ¾ ¾ 15/ 3 2 3/ 37/8 4¼ 1½
16 8 8
125A 16½ ¾ 11/ 16¾ - 0 2 ¾ ¾ 15/8 3 2 3/ 37/8 4¼ 1½
16 8
11
150A 16½ ¾ /16 18¾ - 0 2¼ ¾ ¾ 15/8 3 2 3
/8 37/8 4¼ 111/16
200A 20 11/8 11
/16 20¾ 14¾ 5
/8-11-NC 3 ¾ ¾ 21/8 4½ 25/8 ½ 5 5 2
250 20 11/8 11/
16 223/8 14¾ 5/ -11-NC
8 3 ¾ ¾ 21/8 4½ 25/8 ½ 5 5 23/16
*300 20 11/8 11
/16 223/8 14¾ 5
/8-11-NC 3 ¾ ¾ 21/8 4½ 25/8 * * * 23/16
*350 20 11/8 11
/16 223/8 14¾ 5
/8-11-NC 3 ¾ ¾ 21/8 4½ 25/8 * * * 23/16
450A 24½ 11/8 13/
16 +25½ 14¾ 5/ -11-NC
8 3 ¾ ¾ 113/16 4½ 2¾ ¾ 7¾ 7¾ 27/16
500A 24½ 11/8 13/
16 +25½ 14¾ 5/ -11-NC
8 3 ¾ ¾ 113/16 4½ 2¾ ¾ 7¾ 7¾ 27/16
600A 24½ 11/8 13/
16 +25½ 14¾ 5/ -11-NC
8 3 ¾ ¾ 113/16 4½ 2¾ ¾ 7¾ 7¾ 27/16
750A 24½ 11/8 13/
16 +26¾ 14¾ 5/ -11-NC
8 3 1 1 113/16 6 27/8 ¾ 8¼ 8¼ 27/16
13
1000G 30½ 1¼ /16 +367/8 26 ¾-11-NC 3¾ ¾ ¾ 25/16 6¼ 33/8 ¾ 8 8½ 215/16

Note:
+”XA” dimensions shown apply to 1:1 and speed increasing ratios only. Request certified drawings for others.
*Models 300 and 350 furnished with heat exchanger.
** Contact factory for maximum coupling bore for Fig. 2 or Fig. 3 rotation with 1:2 or 1:3 ratio.
RATIOS AND ROATATIONS: The ratio of a drive is defined as the ratio of the horizontal input speed to vertical output speed. For
example, a 2:1 ratio would have a horizontal speed of twice the vertical speed. There are four rotational schemes available as shown
in figures 1, 2, 3 and 4. Figure 1 is donated a standard rotation.
Figures 2, 3, and 4 are special rotation being manufactured only on order and are not subject to cancellation without charge for
completed parts.

21
Horsepower and Thrust Bearing Rating
Percent of Rated Percent of Thrust
Vertical Shaft RPM
Horsepower Capacity
430 37% 160%
580 46% 145%
690 52% 137%
720 53% 135%
870 61% 126%
960 65% 122%
1160 75% 115%
1460 88% 106%
1760 100% 100%
*2000 107% 96%
*220 112% 93%
*2400 117% 90%
*2600 122% 88%
*2800 128% 86%
*3000 134% 84%
*3460 146% 80%
*3600 150% 79%

* Cooling coils should be specified for models 40, 60A and 80A operating at speeds above 1760 rpm. Consult with the
factory on all applications when the vertical speeds exceed 1760 rpm. Maximum allowable cooling water pressure for
cooling coils is 100 psi and heat exchanger is 150 psi

Features:
Cooling coils are available on models 40, 60A, and 80A, at additional cost and are standard on Model 100A and above.
Non-reverse clutches are standard on all drives. Marine options are available upon request.

Our rigid castings are designed to insure correct alignment. Gears are case hardened alloy steel, lapped in pairs. All
drives have positive pressure oil distribution systems, and bearing life exceeds AGMA recommendations.
All standard hollow shaft gear drives through Model 1200 are approved by Factory Mutual for use with vertical fire
pumps

Special Drives:
Drives listed in this catalogue may also be available with additional options. For applications that require power ratings
larger than listed in this catalogue. Please contact Sterling Pumps for further information.

Weights and Box Dimensions


Net Weight Domestic Skid Export Box Dimensions Volume: Cubic
Model Export Box kg
(kg) (kg) Length (mm) Width (mm) Height (mm) Metres
30 42 50 57 559 356 533 0.11
40A 100 109 125 686 381 686 0.17
40B 105 118 141 737 457 686 0.23
60A 148 159 177 737 483 864 0.31
80A 157 168 186 737 483 864 0.31
100A 166 177 195 737 483 864 0.31
125A 166 177 195 737 483 864 0.31
150A 195 205 230 787 483 914 0.34
200A 286 307 368 889 610 1067 0.57
250 345 366 409 965 610 1016 0.59
*300 345 366 409 965 610 1016 0.59
*350 345 366 409 965 610 1016 0.59
450A 609 645 736 1118 813 1321 1.19
500A 623 659 750 1118 813 1321 1.19
600A 630 666 757 1118 813 1321 1.19
750A 818 859 984 1143 813 1448 1.36
1000G 1205 1389 1505 1473 940 1880 2.61

22
TCI/TCP Series Motors – Cast Iron Three Phase
0.75kW to 315kW - Frame 80 to 355

The three phase cast iron motors combine superior electrical characteristics, high quality design and the
robust strength of cast iron, making this series ideal for all industrial applications.

Operating Parameters
Standard TCI/TCP series motors are designed with the Multi-mount Design
following parameters: TCI/TCP series motors from frame size 80-280 are fitted
• 380V to 415V, 50Hz & 440V to 480V, 60Hz with detachable feet. The multi-mount design allows for
supply the motor feet to be removed and repositioned to either
• Continuous (S1) duty side to produce a side mounted terminal box.
• Ambient temperatures up to 40°C
• Installation up to 1000 MASL Terminal Box.
The terminal box is manufactured from cast iron and is
Connection mounted on top of the motor as standard. Terminal box
• 230V Delta / 400V Star (3kW & below) is separate to the motor body and can be rotated in 90°
• 400V Delta / 690V Star (4kW & above) increments.

Standards Surface Finish


Dimensions and rated outputs for the TCI/TCP series As standard TCI/TCP motors are painted with high quality
conform to Australian Standard AS/NZS 1359 and alkyd enamel with the final colour being RAL 9005 Jet
International Standard IEC 60034 and IEC 60072 Black. Other colours are available upon request.

Standard and High Efficiency Bearings


The TCI range complies with MEPS2 requirements of Bearings fitted are high quality NSK bearinss with C3
AS/NZS 1359.5:2004 Table A2 (Standard Efficiency). diametrical clearances. As standard, frame sizes 80 to
The TCP range complies with MEPS2 requirements of 132 have sealed for life deep groove ball bearings. Frame
AS/NZS 1359.2:2004 Table A3 (High Efficiency). sizes 160 to 355 have re-greaseable bearings with
Motors are tested in accordance with Test Method A of facilities to replenish the grease during operation.
AS/NZS 1359.102.3 as per IEC 60034-2-1. Grease nipples are fitted to the top of the end shields
with a grease relief fitted at the bottom.
Insulation Class
TCI/TCP motors are insulated with Class F materials and Frame Size Bearing
limited to Calss B temperature rise. The windings are Cast Iron D.E. N.D.E
spike resistant making them suitable for use with VVVF 80 6204 ZZ C3
drives. 90 6205 ZZ C3
100 6206 ZZ C3
Thermistors 112 6306 ZZ C3
132 6308 ZZ C3
As standard all TCI/TCP series motors from 160 frame
160 6309 C3
and above are fitted with one set of PTC thermistors. The
180 6311 C3
thermistor termination is located in the main terminal
200 6312 C3
box and has a trip temperature of 150°C as standard.
225 6313 C3
Additional 130°C thermistors can be fitted as an option
250 6314 C3
for alarm connection. Thermistors are available as an
280 6316 C3
option for smaller frame sizes.
315 (2P) 6317 C3
315 (4/6/8) NU319 C3 6319C3
IP Protection 355 (2P) 6319 C3
The standard degree of enclosure protection is IP 55 355 (4/6/8) NU322 C3 6322 C3
(increased with IP protection is available). Shafts are
fitted with an oil sel as standard.

23
Vibration
Vibration levels are within Level N (normal) limits of vibration severity as per IEC 60034 – 14:2007 which are listed below:

Frame Size 56 – 132 160 – 280 315 - 355


Vibration
Mounting
Grade (mm/s) (mm/s) (mm/s)
Type
Suspension 1.5 2.2 2.8
A Rigid
1.3 1.8 2.3
Mount

Conduit Entries
Number of
Frame Size Entry Size
Entries
80 M20 X 1.5 2
90 M20 X 1.5 2
100 M20 X 1.5 2
112 M25 X 1.5 2
132 M25 X 1.5 2
160* M32 X 1.5 2
180* M32 X 1.5 2
200* M50 X 1.5 2
225* M50 X 1.5 2
250* M50 X 1.5 2
280* M50 X 1.5 2
315* M63 X 1.5 2
355* M63 X 1.5 2
*Frames fitted with 1 x M20 cable gland for thermistor termination.

Noise Level
Noise levels comply with the limits shown in IEC 60034.9 and AS1359.109 standards

Output Sound pressure dB(A) @ 1 metre no load


kW 2 Pole 4 Pole 6 Pole 8 Pole
0.75 64 60 58 55
1.1 64 60 59 55
1.5 68 6+0 59 55
2.2 68 62 59 55
3 71 62 63 58
4 71 66 63 58
5.5 75 67 67 64
7.5 75 70 67 64
11 79 71 69 64
15 79 73 69 66
18.5 79 73 69 66
22 84 73 69 67
30 86 75 72 69
37 86 75 72 69
45 88 75 75 69
55 88 77 75 73
75 90 80 77 75
90 90 80 77 75
110 91 83 78 75
132 91 85 79 76
160 91 86 84 81
200 92 88 84 81
250 94 91 87 -
315 94 91 - -

24
TCI Series
Grease
TCI bearings are lubricated with polyurea (Mobil Polyrex EM) based bearing grease suitable for operation in ambient temperatures
from -20°C to +55°C. Bearings are prepacked with grease but it is recommended to lubricate the bearings one hour after
commissioning.

Recommended Bearing Maintenance


Interval Hours
Frame Bearing Grease Qty (g)
2P 4P 6P 8P
160 6309 C3 15 6,600 11,000 14,000 16,200
180 6311 C3 18 6,100 10,600 14,000 15,250
200 6312 C3 20 5,200 10,200 14,100 15,000
225 6313 C3 25 4,900 9,600 13,600 15,000
250 6314 C3 38 2,600 9,200 13,200 14,600
280 6316 C3 42 2,100 9,000 12,800 14,000
315 (2P) 6317 C3 44 2,000 - - -
315 (4/6/8) NU/6319 C3 48 - 6,400 9,300 12,000
355 (2P) 6319 C3 48 1,900 - - -
355 (4/6/8) NU/6322 C3 68 - 4,400 8,300 11,000

Radial & Axial Loads


The table below details the permissible force that can be applied to the motor shaft and are applicable for horizontal mounting only.
The values shown are calculated on a basic bearing life of L10 or 40,000 hours

Permissible Radial Load (N) Permissible Axial Load (N)


Frame Size
2 Pole 4 Pole 6 Pole 8 Pole 2 Pole 4 Pole 6 Pole 8 Pole
80 470 595 690 750 395 540 655 635
90 485 625 720 785 420 570 685 690
100 710 890 1,035 1,150 570 780 940 1,075
112 950 1,240 1,420 1,580 790 1,085 1,310 1,520
132 1,420 1,820 2,100 2,325 1,160 1,590 1,915 2,210
160 1,800 2,350 2,720 3,040 1,480 2,035 2,450 2,810
180 2,490 3,200 3,780 4,215 1,990 2,710 3,270 3,760
200 2,915 3,750 4,350 4,835 2,225 3,065 3,710 4,235
225 3,270 4,000 4,700 5,210 2,460 3,390 4,130 4,750
250 3,590 4,650 5,400 5,980 2,725 3,780 4,575 5,225
280 3,700 8,100 9,375 10,300 3,280 4,560 5,590 6,375
315 (2P) 4,500 - - - 3,825 - - -
315 (4/6/8) - 15,800 17,950 19,750 - 4,855 5,895 6,780
355 (2P) 4,560 - - - 3,980 - - -
355 (4/6/8) - 22,145 25,360 27,890 - 6,135 7,395 8,555

25
TCIM Series – High Specification
0.75kW to 315kW – Frame 80 to 355

Sterling Pump’s TCIM high specification cast iron series motors are designed for severe duty applications and harsh environments

Based on the TCI series, our TCIM High Specification motor has the identical electrical performance
to the TCI series with additional mechanical features as detailed below:
• IP66 protection
• Class H insulation with Class B rise
• Oil seals fitted at both ends
• Rotating slinger at both ends
• Cast iron fan
• Cast iron fan cowl
• Sintered bronze porous drain plugs
• Stainless steel name plate
• Epoxy paint finish

Please refer to the TCI performance data as detailed on pages 66 and 67 of this catalogue.

Surface Finish
TCIM motors are subject to a two pack epoxy coating system with the final colour being RAL 2008 Bright Red Orange.

Operating Parameters
• High specification TCIM series motors are designed with the following parameters:
• 380V to 415V, 50Hz & 440V to 480V 60Hz supply
• Continuous (S1) duty
• Ambient temperatures up to 50°C
• Installation up to 1000 MASL
• Service factors up to 1.25

Available options
• Insulated bearing & earth brush
• Winding RTD’s
• Bearing RTD’s
• Force ventilation
• Auxiliary terminal box

Dimensions
Please refer to page 29 of this catalogue.

26
TCI/TCIM Series Performance Data
Current @ Power
Efficiency Torque
Full 400V Factor Noise Weight
Shaft
Output Load Frame Locked Level Foot
Diameter Full Locked Full ¾ Full ¾ Full Pull Break
kW Speed Size Rotor dB Mount
(mm) Load Rotor Load Load Load Load Load Up Down
(RPM) (% (A) (kg)
(A) (%) (%) (%) (%) (%) (Nm) (%FLT) (%FLT)
FLT)
2880 80A 19 1.76 687 80.1 80.2 0.79 0.71 2.5 292 196 302 64 16
1420 80B 19 1.94 550 81.1 81.5 0.69 0.60 5 303 270 310 60 18
0.75
940 90S 24 2.22 444 76.3 75.7 0.65 0.54 7.6 225 196 252 58 20
690 100LA 28 2.21 363 72.3 73.3 0.68 0.58 10.4 177 175 213 55 34
2880 80A 19 2.39 758 81.2 81.3 0.82 0.74 3.6 283 186 285 64 17
1420 90S 24 2.57 618 82.8 83.8 0.75 0.67 7.4 296 247 297 60 22
1.1
940 90L 24 2.98 487 78.4 78.7 0.69 0.60 11 207 180 245 59 29
690 100LA 28 3.17 390 74.8 75.2 0.67 0.57 15.1 198 192 230 55 35
2880 90S 24 3.19 690 83.1 83.5 0.83 0.75 5.0 276 187 308 68 21
1440 90L 24 3.44 713 85.5 86.1 0.76 0.68 9.9 316 240 313 60 26
1.5
945 100LA 28 3.71 472 80.1 82 0.74 0.66 15.1 172 161 225 59 34
700 112M 28 4.18 403 78.4 79.3 0.68 0.59 20.4 182 180 212 55 42
2890 90L 24 4.61 811 84 84.4 0.83 0.75 7.2 300 222 318 68 22
1440 100La 28 4.55 726 85.8 86.6 0.82 0.76 14.6 260 218 305 62 36
2.2
950 112M 28 5.36 547 82.8 83.9 0.73 0.64 22 220 181 271 59 40
710 132S 38 5.95 420 80.0 80.6 0.67 0.58 29.4 186 174 233 55 68
2900 100L 28 5.59 920 87.0 87.6 0.90 0.87 9.9 309 249 351 71 35
1445 100LB 28 6.27 760 86.0 86.6 0.80 0.73 19.8 239 244 325 62 37
3
960 132S 38 6.42 601 85.5 86.6 0.76 0.70 29.6 188 157 258 63 65
715 132M 38 7.8 529 82.7 83.1 0.70 0.61 39.9 231 203 274 58 77
2915 112M 28 7.56 960 87.4 87.7 0.89 0.84 13.1 332 208 365 71 47
1440 112M 28 8.17 781 87.5 88.2 0.82 0.75 26.4 257 231 335 66 51
4
960 132MA 38 9.21 583 84.7 85.6 0.74 0.68 39.6 200 165 257 63 67
720 160MA 42 9.56 556 85.5 86.0 0.71 0.63 53.0 232 169 254 58 116
2910 132SA 38 10.3 823 87.8 88.3 0.89 0.85 18.0 244 195 343 75 61
1460 132SA 38 11.0 856 88.1 88.5 0.83 0.77 35.9 217 193 350 67 65
5.5
960 132MB 38 12.4 654 86.3 87.5 0.75 0.69 54.5 240 184 261 67 68
720 160MB 42 14.9 600 85.8 84.7 0.63 0.61 74.0 230 190 260 64 147
2920 132SA 38 13.9 1029 89.2 89.6 0.89 0.86 24.5 314 202 366 75 66
1450 132M 38 14.3 823 89.5 90.4 0.85 0.82 49.4 299 117 295 70 77
7.5
980 160M 42 17.5 855 89.7 89.4 0.71 0.63 73.0 331 194 336 67 120
720 160L 42 18.6 600 87.2 86.9 0.67 0.64 100.1 240 190 270 64 147
2950 160MA 42 19.5 858 89.9 90.2 0.91 0.89 35.6 260 93 302 79 113
1470 160M 42 20.4 838 91.7 91.7 0.86 0.81 71.3 287 203 329 71 125
11
975 160L 42 23.8 818 89.4 89.7 0.75 0.68 107.5 309 140 152 70 135
730 180L 48 23.8 660 88.8 88.7 0.75 0.69 145.9 230 200 280 64 183
2950 160MB 42 25.8 901 91.8 92.1 0.92 0.90 48.4 257 132 316 79 132
1470 160L 42 27.4 881 91.1 91.5 0.88 0.84 97.4 253 177 316 73 140
15
980 180L 48 31.4 882 89.6 88.9 0.77 0.70 145.7 267 153 322 69 183
730 200L 55 30.6 660 90.0 90.1 0.78 0.76 198.9 220 200 290 66 240
2950 160L 42 32.0 976 92.1 92.6 0.92 0.91 59.8 302 140 332 79 146
1470 180M 48 33.2 786 91.8 92 0.88 0.84 120.1 254 194 311 73 158
18.5
980 200LA 55 36.9 853 91.2 91.2 0.81 0.74 179.4 207 139 320 69 232
730 225S 60 38.7 660 90.7 90.4 0.76 0.72 243.7 220 200 320 66 315
2950 180M 48 39.1 843 91.2 91 0.90 0.88 71.2 266 163 330 84 177
1465 180L 48 38.9 767 91.9 92.5 0.89 0.86 143.1 225 155 269 73 183
22
980 200LB 55 42.6 1031 91.9 92.1 0.83 0.78 213.5 313 156 342 69 250
740 225M 60 43.5 660 91.2 91.4 0.80 0.78 289.7 210 190 310 67 348

27
TCI/TCIM Series Performance Data Continued
Current @ Power
Efficiency Torque
Full 400V Factor Noise Weight
Shaft
Output Load Frame Locked Level Foot
Diameter Full Locked Full ¾ Full ¾ Full Pull Break
kW Speed Size Rotor dB Mount
(mm) Load Rotor Load Load Load Load Load Up Down
(RPM) (% (A) (kg)
(A) (%) (%) (%) (%) (%) (Nm) (%FLT) (%FLT)
FLT)
2955 200LA 55 52.9 703 92.0 92.3 0.90 0.88 96.9 205 104 254 86 233
1480 200L 55 57.2 814 92.5 92.7 0.82 0.76 193.5 237 191 295 75 242
30
985 225M 60 54.9 815 91.9 92.4 0.86 0.83 290.5 264 151 257 72 335
740 250M 65 61.5 660 92.1 91.6 0.76 0.71 392.4 210 190 270 69 397
2955 200LB 55 64.9 759 92.7 93.1 0.90 0.88 119.6 244 144 260 86 246
1475 225S 60 65.4 743 91.2 90.7 0.85 0.82 239.1 222 147 243 75 315
37
980 250M 65 68.7 646 93.2 93.3 0.85 0.82 359.2 186 135 232 72 398
740 280S 75 73.5 660 92.7 92.5 0.78 0.74 484.0 210 180 250 69 500
2955 225M 55 77.6 744 93.2 93.4 0.91 0.89 145.2 273 113 251 88 322
1475 225M 60 85.1 695 93.1 92.9 0.83 0.78 290.5 207 187 333 75 352
45
985 280S 75 81.5 850 92.7 93.0 0.86 0.82 434.7 284 156 272 75 505
740 280M 75 88.9 660 93.2 93.1 0.78 0.77 584.7 200 180 250 69 594
2970 250M 60 93.3 892 94.5 94.3 0.91 0.90 176.8 302 142 299 88 420
1480 250M 65 98.7 805 93.6 93.9 0.86 0.83 354.4 264 167 268 77 420
55
985 280M 75 99.0 897 93.5 93.6 0.87 0.83 531.3 321 181 311 75 596
740 315S 80 107.2 750 93.7 93.1 0.79 0.76 709.8 200 180 240 73 1025
2970 250MB 60 126.3 970 94.3 94.2 93.2 0.91 241.0 291 153 339 88 475
2970 280S 65 125.3 898 93.9 93.9 0.93 0.93 241.0 256 105 281 90 572
1480 250MB 65 131.4 755 94.0 93.8 0.89 0.85 485.6 258 149 230 79 448
75
1480 280S 75 127.7 756 94.9 95.2 0.90 0.89 482.5 254 211 237 80 570
980 315S 80 128.9 790 94.4 94.1 0.89 0.86 730.8 210 190 250 77 809
740 315M 80 145.2 770 94.4 94.0 0.79 0.75 967.8 200 180 230 75 1108
2970 280M 65 148.3 1009 94.5 94.3 0.93 0.92 289.1 294 123 302 90 637
1485 280M 75 152.9 860 94.4 94.8 0.92 0.90 578.7 297 229 260 80 658
90
980 315M 80 152.3 800 94.8 94.2 0.90 0.88 877.0 200 180 230 77 962
740 315LA 80 171.5 780 94.7 94.5 0.80 0.78 1161.4 200 180 220 75 1155
2980 315S 65 185.5 770 95.1 95.2 0.90 0.88 357.3 190 170 225 91 1008
1480 280MB 75 188.4 773 94.7 94.6 0.89 0.88 709.8 246 172 308 81 658
110
1485 315S 80 185.1 780 95.3 95.1 0.91 0.89 709.8 210 180 230 83 1049
980 315LA 80 185.5 770 95.1 95.3 0.90 0.87 1071.9 200 180 235 78 989
2980 315M 65 219.5 760 95.4 95.2 0.91 0.89 428.7 190 160 220 91 1062
132 1485 315M 80 222.8 700 95.0 94.2 0.90 0.87 848.9 248 164 323 85 1049
980 315LB 80 224.4 800 95.4 95.1 0.89 0.87 1286.2 200 175 230 79 1082
2980 315LA 65 268.7 780 95.5 95.4 0.90 0.90 518.8 205 180 240 91 1222
1485 315LA 80 265.2 790 95.7 95.5 0.91 0.91 1032.4 200 180 230 86 1222
160
985 355MA 100 265.5 760 95.6 95.3 0.91 0.89 1559.0 220 195 238 84 1580
745 355MB 100 287.3 780 95.7 95.4 0.84 0.82 2050.9 200 180 235 81 1740
2985 315LB 65 339.7 790 95.5 95.2 0.89 0.88 648.5 215 170 240 91 1240
1490 315LB 80 335.2 770 95.7 95.6 0.90 0.90 1290.5 200 180 235 88 1190
200
985 355MB 100 336.0 760 95.6 95.7 0.90 0.88 1948.8 210 190 245 84 1760
745 355LB 100 350.8 770 95.7 95.5 0.86 0.85 2563.6 205 185 235 81 1990
2985 355M 75 419.8 780 95.5 95.2 0.90 0.89 810.6 200 180 240 94 1780
250 1490 355M 100 423.7 790 95.7 95.4 0.89 0.87 1613.0 230 190 260 91 1820
985 355LB 100 424.1 780 95.6 95.2 0.89 0.86 2436.0 210 190 250 87 1990
2985 355LB 75 531.8 740 95.0 95.6 0.90 0.86 1021.4 225 195 240 94 1780
315
1490 355LB 100 532.3 758 95.8 96.1 0.89 0.89 2020.3 275 185 255 91 1700

28
TCP Series Performance Data
Current @ Power
Efficiency Torque
Full 400V Factor Noise Weight
Shaft
Output Load Frame Locked Level Foot
Diameter Full Locked Full ¾ Full ¾ Full Pull Break
kW Speed Size Rotor dB Mount
(mm) Load Rotor Load Load Load Load Load Up Down
(RPM) (% (A) (kg)
(A) (%) (%) (%) (%) (%) (Nm) (%FLT) (%FLT)
FLT)
2890 80A 19 1.64 735 81.6 81.3 0.81 0.72 2.5 315 235 324 64 15.2
0.75 1435 80B 19 1.81 618 83.1 83.4 0.72 0.64 5.0 288 241 296 60 18.2
945 90S 24 2.01 469 80.0 80.3 0.67 0.58 7.5 231 211 267 58 21.5
2900 80B 19 2.38 809 83.1 82.6 0.80 0.72 3.6 341 262 351 64 17.1
1.1 1440 90S 24 2.58 674 84.9 85.4 0.72 0.64 7.3 308 248 312 60 23.0
950 90L 24 2.94 519 81.0 81.1 0.67 0.57 11.1 278 250 298 59 25.5
2895 90S 24 3.11 825 84.9 85.0 0.82 0.74 4.9 351 210 373 68 21.5
1.5 1440 90L 24 3.60 722 85.7 86.0 0.70 0.61 9.9 385 294 367 60 26.3
945 100LA 28 3.55 504 82.4 83.8 0.74 0.66 15.1 214 209 262 59 33.5
2895 90L 24 4.49 808 86.5 86.9 0.82 0.74 7.2 312 226 360 68 24.6
2.2 1450 100LA 28 4.45 793 87.2 87.8 0.82 0.75 14.5 296 248 355 62 35.5
950 112M 28 5.54 543 84.6 85.3 0.68 0.60 22 208 188 254 59 40.0
2915 100L 28 5.60 933 87.4 87.9 0.89 0.84 9.8 318 262 360 71 35.5
3 1450 100LB 28 6.20 829 88.2 88.7 0.79 0.71 19.7 339 291 378 62 38.5
965 132S 38 6.80 593 85.9 86.9 0.74 0.67 29.6 200 175 271 63 59.0
2925 112M 28 7.22 1051 88.1 88.5 0.91 0.87 13.1 347 249 398 71 44.5
4 1450 112M 28 7.93 854 88.8 89.4 0.82 0.75 26.3 309 266 374 66 47.0
970 132MA 38 8.88 678 87.4 88.1 0.74 0.67 39.3 237 183 304 63 75.5
2930 132SA 38 9.98 991 89.5 89.7 0.89 0.85 17.9 318 249 402 75 63.2
5.5 1460 132S 38 10.5 898 89.8 90.5 0.84 0.79 35.9 231 198 350 67 68.3
970 132MB 38 12.6 738 88.3 88.7 0.71 0.63 53.9 289 220 348 67 76.3
2925 132SB 38 13.0 1005 90.6 91.4 0.92 0.90 24.5 265 191 362 75 70.0
7.5 1460 132M 38 13.9 889 90.5 91.3 0.86 0.81 49.4 288 175 350 70 79.0
960 160M 42 16.2 750 89.1 90.3 0.75 0.70 74.6 230 187 280 67 120
2960 160MA 42 19.3 932 91.3 91.8 0.90 0.87 35.5 225 100 341 79 121
11 1470 160M 42 19.8 846 91.8 92.3 0.87 0.83 71.4 300 60 301 71 128
960 160L 42 22.3 730 91.2 90.8 0.75 0.78 109.4 250 200 280 70 134
2955 160MB 42 26.2 1038 92.1 92.1 0.90 0.87 48.4 331 175 356 79 123
15 1470 160L 42 26.5 945 92.6 92.9 0.88 0.85 97.2 263 115 317 73 140
960 180L 48 30.1 800 91.2 92.0 0.79 0.77 149.2 250 140 280 69 184
2955 160L 42 31.1 950 92.7 93.2 0.93 0.91 59.8 279 117 331 79 160
18.5 1475 180M 48 33.3 875 92.9 93.2 0.86 0.81 119.7 263 203 339 73 160
980 200LA 55 36.2 928 91.7 92.0 0.8 0.74 179.5 289 60 321 69 188
2960 180M 48 37.9 956 93.0 93.3 0.90 0.88 71.0 246 180 345 84 183
22 1475 180L 48 38.9 978 93.8 94.0 0.87 0.83 142.3 305 194 341 73 186
980 200LB 55 42.1 1021 92.7 92.8 0.81 0.76 213.4 277 167 348 69 250
2965 200LA 55 51.6 889 94.0 94.2 0.89 0.86 96.5 289 183 332 86 247
30 1480 200LA 55 58.4 852 93.6 93.5 0.79 0.72 193.3 287 267 370 75 245
980 225M 60 53.0 661 92.8 93.6 0.88 0.86 291.8 193 201 221 72 252
2965 200LB 55 63.2 793 93.8 94.2 0.9 0.88 119.3 273 152 288 86 268
37 1480 225S 60 65.0 919 94.3 94.5 0.87 0.84 238.3 271 142 286 75 320
975 250M 65 67.3 700 93.3 94.0 0.85 0.83 362.4 180 130 200 72 399
2965 225M 55 74.9 638 94.4 94.7 0.92 0.91 144.9 176 66 262 88 322
45 1480 225M 60 79.1 898 94.8 94.9 0.87 0.83 290.0 275 170 291 75 350
990 280S 75 80.1 1028 93.9 93.9 0.86 0.82 433.9 361 242 347 75 410
2970 250M 60 92.4 1004 94.9 94.8 0.91 0.88 176.6 293 183 351 88 420
55 1485 250M 65 98.0 884 95.1 95.2 0.85 0.81 353.8 291 192 310 77 460
990 280M 75 98.3 1001 94.5 94.3 0.85 0.81 530.2 350 192 341 75 520
75 2975 280S 65 125.2 1057 95.2 95.0 0.91 0.89 240.4 298 164 360 90 630
1490 280S 75 130.6 1046 95.0 95.3 0.87 0.83 480.6 358 208 340 80 620
90 2975 280M 65 149.7 1100 95.1 94.9 0.91 0.90 288.5 320 285 351 90 650
1490 280M 75 158.6 1074 95.9 95.8 0.85 0.81 576.7 355 220 361 80 673
110 1490 315S 80 190.0 866 95.8 95.6 0.87 0.84 704.8 333 231 383 83 1030
132 1490 315M 80 224.3 906 95.8 95.9 0.89 0.86 845.8 366 103 383 85 1070

29
TCI/TCP/TCIM Series Motor Outline Dimensions

TCI/TCP/TCIM Series Dimensional Data


Foot Mounting Shaft General
Frame Size
H A B C D E F G K AA AD HD AC L TBS TBW TBH
80 80 125 100 50 19 40 6 15.5 9 154 209 129 158 290 48 105 105
90s/l 90 140 100/125 56 24 50 8 20 10 178 231 150 176 320/345 49 114 114
100 100 160 140 63 28 60 8 24 12 203 251 151 199 385 76 114 114
112 112 190 140 70 28 60 8 24 12 231 292 180 220 405 73 134 134
132S/M 132 216 140/178 89 38 80 10 33 12 264 330 198 259 457/505 62 134 134
160M/L 160 254 210/254 108 42 110 12 37 15 316 404 244 313 605/650 91 162 162
180M/L 180 279 241/279 121 48 110 14 42.5 15 361 442 262 360 687/725 160/180 162 187
200L 200 318 305 133 55 110 16 49 19 392 500 300 399 769 193 186 233
225S 4, 8 225 356 286 149 60 140 18 53 19 438 557 332 465 810 199 186 233
2 225 356 311 149 55 110 16 49 19 438 557 332 465 805 212 186 233
225M 4, 6, 225 356 311 149 60 140 18 53 19 438 557 332 465 835 212 186 233
8
2 250 406 349 168 60 140 18 53 24 484 616 366 506 915 234 218 260
250M 4, 6, 250 406 349 168 65 140 18 58 24 484 616 366 506 915 234 218 260
8
2 280 457 368/419 190 65 140 18 58 24 557 673/690 393/410 559 984/1035 265/277 218/245 260/280
280S/M 4, 6, 280 457 368/419 190 75 140 20 67.5 24 557 673/690 393/410 559 984/1035 265/277 218/245 260/280
8
2 315 508 406 216 65 140 18 58 28 628 825 510 682 1205 200 290 350
315S 4, 6, 315 508 406 216 80 170 22 71 28 628 825 510 682 1235 200 290 350
8
2 315 508 457/508 216 65 140 18 58 28 628 825 510 682 1355 200 290 350
315M/L 4, 6, 315 508 457/508 216 80 170 22 71 28 628 825 510 682 1385 200 290 350
8
2 355 610 560/630 254 75 140 20 67.5 28 740 1010 655 820 1500 140 330 380
355M/L 4, 6, 355 610 560/630 254 100 210 28 90 28 740 1010 655 820 1570 140 330 380
8

B5 B14A
Frame Size Frame Size
N M P S T N M P D T
80-90 130 165 198 4-12 3.5 80 80 100 118 M6 3
100-112 180 215 250 4-15 4 90 95 115 138 M8 3
132 230 265 300 4-15 4 100-112 110 130 158 M8 3.5
160-180 250 300 350 4-19 5 132 130 165 198 M10 3.5
200 300 350 400 4-19 5
225 350 400 450 8-19 5
250-280 450 500 550 8-19 5
315 550 600 660 8-24 6
355 680 740 800 8-24 6

30
Mounting Arrangements
B3 B5 B3/B5 V1 V3 V5 V6 B6 B7 B8 V1/V5 V3/V6

Frame
Size

56-200 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
225-250 ✓ ✓ ✓ ✓ - - - - - - - -
380-355 ✓ - ✓ ✓ - - - - - - - -

B14 B3/B14 V18 V19 V5/V18 V6/V19

Frame
Size

56-160 ✓ ✓ ✓ ✓ ✓ ✓

Maximum Starting Time Starts Per Hour


Frame Method 2 Pole 4 Pole 6 Pole 8 Pole Frame 2 Pole 4 Pole 6 Pole 8 Pole
56-71 D.O.L 20 28 44 - 56-71 22 40 40 -
80 D.O.L 15 26 40 40 80-90 18 35 40 40
90 D.O.L 10 15 25 30 100-132 12 22 25 25
100 D.O.L 12 14 18 40 160-180 10 18 22 22
112 D.O.L 10 10 18 35 200 6 12 12 12
132 D.O.L 14 12 12 25 225 5 10 10 10
160-315 D.O.L 15 15 20 22 250 4 8 8 8
315 Star-Delta 45 45 60 65 280 3 6 6 8
315 3 4 6 6
355 2 3 3 3

IP Rating Chart
Protection against solid objects Protection against liquids
First Number Definition Second Number Definition
0 No Protection 0 No Protection
Protected against vertically falling drops of
1 Protected against solid objects over 50mm 1
water
Protected against direct sprays up to 15° from
2 Protected against solid objects over 12mm 2
the vertical
Protected against direct sprays up to 60° from
3 Protected against solid objects over 2.5mm 3
the vertical
Protected against sprays from all directions –
4 Protected against solid objects over 1mm 4
limited ingress permitted
Protected against dust – limited ingress (no Protected against low pressure jets of water
5 5
harmful deposit) from all directions – limited ingress permitted
Protected against strong jets of water from all
6 Totally protected against dust 6
directions
Protected against the effects of temporary
7
immersion up to 1 metre
Protected against long periods of immersion
8
under pressure.

31
Sterling Pumps Pty. Ltd.
14 Sharnet Circuit
Pakenham

Phone: 03 5941 3400


Fax: 03 5940 2645

[email protected]

SPA026 08/18
www.sterling.com.au

You might also like