1-Non Central Carrer
1-Non Central Carrer
FOR IN-HOME
COMFORT
Carrier Ductless Systems
Product Catalog Fall 2023
2
TABLE OF
CONTENTS
Ductless Technology & Benefits
4
Ductless & VRF Product Lineup
14
Single Zone Residential Products
Infinity System®
18
20
Performance Series™ 24
Comfort Series™ 44
3
ENHANCING YOUR
IN-HOME COMFORT
ONE ROOM AT A TIME
Ductless systems are becoming an increasingly
popular HVAC choice in homes across the U.S. Why?
Because not only can they heat and cool any space with
precision—but, in most cases, they don’t require ductwork,
which provides homeowners with increased flexibility.
Often called “mini-splits,” ductless systems use the same process for heating and cooling
as traditional systems. However, instead of delivering hot or cool air to an entire home
(through ducts and vents), each ductless unit blows air directly into a single room.
This allows for greater comfort control of individual spaces and improves energy
efficiency and sustainability along the way.
4
CARRIER. MAKING
INDOOR SPACES
MORE LIVABLE.
As a general rule of thumb, complete ductless
systems include:
5
VERSATILE UNITS.
STREAMLINED DESIGNS.
Almost every home has a room that always seems
drafty or overheated. Perhaps it’s a sunroom that gets
too hot to be enjoyable or a master bedroom that’s just
not cool enough for sleeping.
6
Experience the best of comfort and design flexibility
with the new Carrier one-way cassette. This versatile
unit can be incorporated into a single or multi-zone
system and easily installed nearly anywhere in the
home or office with no modifications to existing framing.
The latest addition to the Carrier ductless series, the one-way cassette is the ideal choice for
homeowners seeking an exceptionally efficient, whisper-quiet and stylish system that provides
dependable comfort in all climates.
7
MORE OF WHAT
YOU NEED
& LESS OF WHAT
YOU DON’T
It goes without saying that ductless systems have
benefits to spare. Even the most challenging areas to
control and maintain can be turned into comfortable,
usable spaces with the addition of ductless.
ENHANCED COMFORT
• Air Quality—Each Carrier ductless unit has • Smart Controls—Carrier Infinity ductless
removable, washable air filters inside. This helps systems have built-in Wi-Fi®. Most ductless
prevent airborne particles from recirculating in systems have integrated sensors that can
your home's air, keeping it fresher and cleaner. direct airflow toward the people in the room
Plus, our top-of-the-line systems allow you to and third-party thermostat compatibility.
precisely control humidity levels, so rooms never
• Quiet Operation—Ultra-quiet operation reduces
feel too damp or too dry.
noise pollution both indoors and out for more
• Multi-Zone Capabilities—Our multi-zone peaceful, comfortable spaces.
outdoor unit can connect and power several
indoor units at the same time, which helps
achieve the desired comfort level for every room.
8
GREATER SUSTAINABILITY
•E
nergy Efficiency—Ductless systems only use power when it’s CARRIER DUCTLESS
needed, reducing energy consumption and keeping costs down in
tandem. Plus, owners may qualify for added efficiency rebates from SYSTEMS DON’T
local utilities companies. Visit the Carrier Rebate Center to see eligible
products and incentives for your area. JUST KEEP YOU
•E
nergy Savings—Because Carrier ductless systems allow you to COMFORTABLE—
select which rooms to heat or cool (instead of an entire house), energy
use is limited to those specific areas. This also helps offset the energy THEY ALSO HELP
loss commonly experienced in older homes.
THE PLANET AND
• SEER2 (Seasonal Energy Efficiency Ratio) measures the cooling
efficiency of a system. The higher the SEER2, the less energy needed KEEP YOUR UTILITY
to cool your home. Carrier systems have a SEER2 rating of up to 28.5.
BILLS DOWN.
• HSPF2 (Heating Seasonal Performance Factor) is how the heating
efficiency of the system is measured. Just like SEER2, the higher the
HSPF2 number, the more efficient the heat pump. Carrier systems
have an up to 18.0 HSPF2 rating.
9
IMPROVED
APPLICATION
FLEXIBILITY
RENOVATIONS & EXPANSIONS
The flexibility of ductless systems means they can be
easily integrated into new architecture without having to
accommodate for additional space between walls and
ceilings. When converting an existing area that may not be
connected to the central HVAC system into a new living
space (i.e., a basement, attic or garage), ductless is a simple HOME ADDITIONS
solution for providing comfort year-round.
EASY INSTALLATION
The system’s refrigerant pipe and electrical cable enter
the house through a three-inch hole in the wall. That’s it!
Installation is quick, non-intrusive and minimally disruptive
to your space.
RENOVATIONS
CONSISTENT TEMPERATURES
Have a room that’s too hot or too cold? No problem.
Ductless can help you target areas with uneven
temperatures for more consistent comfort.
10
SUNROOMS
ATTICS
GARAGES
76°F
72°F
66°F
BASEMENTS
ROOMS THAT
ARE TOO COLD
68°F
11
A BRAND THAT
HAS NEVER
STOPPED
INNOVATING—
& NEVER WILL
Founded upon Willis Carrier’s invention of the
modern air conditioning in 1902, Carrier is a world
leader in heating, cooling and refrigeration solutions.
We are constantly building upon our history of
proven innovation with new products and services
that improve global comfort and efficiency—
addressing customer challenges and providing great
experiences along the way.
But our innovation doesn't stop there. From the hiring of the first female air conditioning
engineer to the creation of the first air conditioning systems for skyscrapers, homes,
factories and ships, Carrier continues to look for ways to advance comfort.
As a trusted partner for precise temperature and humidity control, we know a thing or
two about innovation. And it’s this same innovation that we put to work in your home.
For enhanced in-home comfort, Carrier is the expert you can count on.
12
"CARRIER IS ALWAYS
FORWARD-THINKING.
I ABSOLUTELY LOVE HOW
THEY'RE ALWAYS DEVELOPING
NEW TECHNOLOGY, AND NOT
JUST WITH UTILITY SAVINGS
AND EFFICIENCIES IN MIND.
THEY'RE ALSO THINKING
ABOUT US, THE DEALERS AND
THE TECHNICIANS."
Daren Shawver
IMS Heating and Air
"In the 20 years we've worked "Ductless gives us so "They invented the
together, Carrier has been much adaptability for industry, and they
tested. And every time, different needs and spaces." continue to innovate."
Carrier's passed the test." Mike Hinton Brianna Woods
Ryan Brown Mike's Heating & Cooling Advantage Heating & Cooling
Conway Air Conditioning
13
DUCTLESS & VRF SYSTEMS
Product Lineup
Single Zone Residential
Capacity Range
• 9-18K Btu/h
• Up to 28.5 SEER2
• Up to 18.0 HSPF2
38MPRB Outdoor Unit 40MPHB High Wall 40MPHB High Wall
Sizes: 09 / 12 / 18 Sizes: 09 / 12 Size: 18
Pump Type
Heat Pump
Capacity Range
• 6–36KBtu/h 38MARB Outdoor Unit 40MAHB High Wall 40MBCQ Cassette 40MBCAQ Cassette
• Up to 28.1 SEER2 Sizes: 06 / 09 / 12 / Sizes: 06 / 09 / 12 / Sizes: 09 / 12 / 18 Size: 24
18 / 24 / 30 / 36 18 / 24 / 30 / 36
• Up to 12.0 HSPF2
Pump Type
Heat Pump
40MBDQ Ducted 40MBDAQ High Static 40MCCAQ
Sizes: 09 / 12 / 18 / 24 Slim Ducted One-Way Cassette
Sizes: 09 / 12 / 18 / 24 Sizes: 06 / 09 / 12 / 18
Capacity Range
• 9–36KBtu/h 38MHRDC Outdoor Unit 40MHHAC High Wall 40MHHAQ High Wall
• Up to 21.5 SEER2* Sizes: 09 / 12 / 18 / 24 Sizes: 09 / 12 / 18 / 24 Sizes: 09 / 12 / 18 / 24 / 30 / 36
• Up to 9.4 HSPF2 Cooling Only Cooling Only Heat Pump
Pump Type
Heat Pump
Cooling Only
14
Multi-Zone Residential
Product Line Outdoor Units Indoor Units
Capacity Range
38MGRB 38MGRB 40MPHB 40MAHB 40MHH 40MBAB 40MCCAQ
• 18–48KBtu/h Outdoor Unit Outdoor Unit High Wall High Wall High Wall Air Handler One-Way Cassette
• Up to 26.0 SEER2 Size: 18R Size: 36R Sizes: 09 / 12 / 18 Sizes: 06 / 09 / 12 / Sizes: 09 / 12 / Sizes: 18 / 24 / Sizes: 06 / 09 / 12 / 18
38MGHB High 18 / 24 / 30 / 36 18 / 24 / 30 / 36 30 / 36
• Up to 10.5 HSPF2 Heat Outdoor Unit
Sizes: 24HH / 30HH
Pump Type
Heat Pump
38MGRB Outdoor Unit 40MBDQ Ducted 40MBDAQ 40MBFQ Console 40MBFAQ 40MBCQ 40MBCAQ
Size: 48R Sizes: 09 / 12 / High Static Size: 18 / 24 Floor Console Cassette Cassette
38MGHB High Heat 18 / 24 Slim Ducted Size: 12 Sizes: 09 / Size: 24
Outdoor Unit Sizes: 09 / 12 / 18
Sizes: 36HH / 48HH 12 / 18 / 24
VRF PRODUCTS
Carrier VRF
Capacity Range
40VMW High Wall 40VMC 4-way 40VMF 40VMI One-way 40VMU 40VMR Floor
• 36–60K Btu/h Sizes: 12 / 15 / Compact Cassette 4-way Cassette Compact Cassette Underceiling Console
• Up to 19.2 SEER2 18 / 24 / 30 / Sizes: 05 / 07 / Sizes: 09 / 12 / Sizes: 05 / 07 / 09 / Sizes: 12 / 15 / 18 / Sizes: 07 / 09 /
36 / 48 09 / 12 / 15 15 / 18 / 24 / 12 / 15 / 18 / 24 24 / 30 / 36 / 48 12 / 15 / 18 / 24
• Up to 9.2 HSPF2 30 / 36 / 48
38VMB-H
Pump Type
Outdoor Unit
Sizes: 36 / 48 / 60
2-pipe Heat Pump
2-pipe Single-Phase
40VMV Vertical Air 40VML Low 40VMM Medium 40VMH High 40VMA Outside
Heat Pump Handling Unit (AHU) Static Ducted Static Ducted Static Ducted Air Ducted
Sizes: 12 / 18 / 24 / (Slim Profile) Sizes: 07 / 09 / Sizes: 24 / 30 / 36 / Sizes: 36 / 48 /
30 / 36 / 48 / 53.5 Sizes: 07 / 09 / 12 / 15 / 18 / 24 / 48 / 53.5 / 72 / 96 53.5 / 72 / 96
12 / 15 / 18 / 24 30 / 36 / 48
MMK7 High Wall MMU1Y One-way MMUM 4-way MMU4 4-way MMC8 Underceiling
Sizes: 07 / 09 / 12 / Cassette Compact Cassette Cassette Sizes: 18 / 24 /
Capacity Range 15 / 18 / 24 / 30 / 36 Sizes: 07 / 09 / 12 Sizes: 07 / 09 / Sizes: 07 / 09 / 12 / 30 / 36 / 48
• 72 / 144K Btu/h 12 / 15 / 18 15 / 18 / 24 / 30 /
36 / 42 / 48 / 54
• Up to 27.4 IEER
MMYF-1P Heat Recovery
• Up to 31.3 SCHE Outdoor Unit
Sizes: 72 / 144
Pump Type _____________
Heat Pump MML4 Floor MMDP Slim Ducted MMD6B MMD6H High MMLB Floor
Console – Exposed (Low Profile) Concealed Ducted Static Ducted Console – Recessed
3-pipe System
Sizes: 07 / 09 / Sizes: 07 / 09 / (Medium Static) Sizes: 24 / 30 / 36 / Sizes: 07 / 09 /
_______________ 12 / 15 / 18 / 24 12 / 15 / 18 Sizes: 07 / 09 / 12 / 48 / 54 / 72 / 96 12 / 15 / 18 / 24
15 / 18 / 21 / 24 /
Capacity Range 30 / 36 / 42 / 48 / 54
• 36–60K Btu/h
• Up to 23.1 SEER2
• Up to 10.9 HSPF2 MCY7 Heat Pump Outdoor Unit
Sizes: 36 / 48 / 60
Pump Type
15
DUCTLESS & VRF SYSTEMS
Product Lineup
Light Commercial
Capacity Range
• 36–58K Btu/h
38MBRC Outdoor Unit 40MBCAQ Cassette 40MBFQ Console 40MBDQ Ducted 40MBDQ Ducted
• Up to 19.8 SEER2 Size: 36 Sizes: 36 / 48 Sizes: 36 / 48 / 58 Sizes: 36 / 48 Size: 58
• Up to 10.2 HSPF2
Pump Type
Heat Pump
38MBRC Outdoor Unit 40MBDAQ High Static 40MBDAQ High Static 40MBAB Air Handler
Sizes: 48 / 58 Slim Ducted Slim Ducted Sizes: 36 / 48 / 60
Sizes: 36 / 48 Size: 58
Horizontal Discharge
Capacity Range
• 18–60k Btu/h
• 34SCA5:
Up to 17.1 SEER2 38MURA Outdoor Units
• 38MURA: Sizes: 18 / 24 / 30 / 36 / 48 / 60
Heat Pump
Up to 18.0 SEER2
Up to 9.8 HSPF2
Pump Type
Heat Pump
Cooling Only
34SCA5 40MUAA Air Handler
Sizes: 18 / 24 / 30 / 36 / 48 / 60 Sizes: 18 / 24 / 30 / 36 /
Cooling Only 48 / 60
RAV PRODUCTS
Capacity Range
RAVAT2 RAVAT2 RAVKR2 High Wall RAVUT2 Cassette
• 12–48KBtu/h Outdoor Unit Outdoor Unit Sizes: 12 / 18 / 24 / 30 / 36 Sizes: 18 / 24 / 30 / 36 /
• Up to 25.5 SEER2 Sizes: 12 / 18 Size: 24 42 / 48
• Up to 11.3 HSPF2
Pump Type
Heat Pump
V R O O M S E L E C T I O N S O F T WA R E Features include:
• Auto updates
With VRoom Selection Software, engineers can easily design, • Sleek drag-and-drop interface
• Table edit options for quick editing
lay out and prepare VRF and DLS systems for quotes. of multiple units
• Quick global edits for wired controllers
16
17
SINGLE ZONE
RESIDENTIAL
18
38MPRB Outdoor Unit
Up to 28.5 SEER2
Up to 18.0 HSPF2
Sizes: 09 / 12 / 18
40MBCQ Cassette
Sizes: 09 / 12 / 18
40MBCAQ Cassette
Size: 24
40MBDQ Ducted
Sizes: 09 / 12 / 18 / 24
40MBDAQ High Static Slim Ducted
Sizes: 09 / 12 / 18 / 24
40MBFQ Console
Sizes: 18 / 24
19
INFINITY® SYSTEM
38MPRB OUTDOOR UNIT
An Efficient
Single Zone Residential
COMPATIBLE WITH:
• 40MPHB High Wall (p 22)
20 INFINITY® SYSTEM
INFINITY® SYSTEM
38MPRB OUTDOOR UNIT
SPECIFICATIONS:
COMPATIBILITY:
Outdoor Unit
Indoor Unit
38MPRBQ09AA3 38MPRBQ12AA3 38MPRBQ18AA3
40MPHBQ09XA3 •
High Wall 40MPHBQ12XA3 •
40MPHBQ18XA3 •
High Wall
Indoor Model 40MPHBQ09XA3 40MPHBQ12XA3 40MPHBQ18XA3
ENERGY STAR® YES YES YES
Cooling System Tons 0.75 1 1.5
Cooling Rated Capacity Btu/h 9,000 12,000 18,000
Cooling Cap. Range Min - Max Btu/h 2,800~16,900 2,800~16,900 6,900~27,000
SEER2 28.5 27.0 26.3
EER2 16.0 14.0 15.3
Heating Rated Capacity (47° F) Btu/h 12,000 12,000 20,000
Heating Rated Capacity (17° F) Btu/h 6,900 6,900 11,000
Heating Maximum Capacity (17° F) Btu/h 18,100 18,100 11,300
Heating Maximum Capacity (5° F) Btu/h 13,900 13,900 25,400
Heating Cap. Range Min - Max Btu/h 5,100~19,000 5,100~19,000 9,900~31,000
HSPF2 18.0 12.0 15.5
COP (47° F) W/W 3.84 3.84 4.30
COP (17° F) W/W 2.89 2.89 2.80
COP (5° F) W/W 2.00 2.00 2.00
Infinity®
High Wall
FEATURES Sizes: 09 / 12 / 18
• Modes: Cool, Heat, Dry, Fan, Auto
KEY FEATURES
• Four Fan speeds including Turbo Mode
Superior Comfort
• Carbon Filter
With innovative features, like the Occupancy Sensor,
• Sleep Mode airflow is directed toward or away from anyone
• Relative Humidity Sensor in the room.
COMPATIBLE WITH:
• 38MPRB Outdoor Unit
Single Zone (p 20)
• 38MGRB & 38MGHB
Outdoor Unit Multi-Zone (p 54)
®
Optional Wireless
Wired Controller Remote
(7-Day Programmable) Controller
22 INFINITY® SYSTEM
INFINITY® SYSTEM
40MPHB HIGH WALL
SPECIFICATIONS:
COMPATIBILITY:
Performance™
Heat Pump with
Basepan Heater
FEATURES Heat Pump With Basepan Heater
• 100% Heating capacity at -4° F (-20° C)* Inverter Compressor
• Available in 208/230V (6-36K) and 115V (12K) Up to 28.1 SEER2
• Built-in basepan heater Up to 12.0 HSPF2
• Auto-restart function Sizes: 06 / 09 / 12 / 18 / 24 / 30 / 36 (208-230V);
Size 12 (115V)
• Anti-corrosive fin coating
Select sizes are ENERGY STAR® certified based
• Piping length up to 213 ft (65m)
on indoor unit pairing
• Cooling operating range -22° ~ 130° F
(-30° ~ 55° C)
KEY FEATURES
• Heating operating range -22° ~ 86° F
(-25° ~ 30° C) Extra-Low Temperature Heating
Heat output up to 69% of rated capacity at -22° F (-30° C). So, when it’s
cold outside, it will be warm inside, making this a primary heat source
COMPATIBLE WITH: and eliminating the need for a backup.
• 40MAHB High Wall (p 28) Rapid Cooling and Heating
• 40MCCAQ One-Way Cassette (p 30) After startup, the compressor quickly gets up to maximum speed,
cooling or heating the room in minutes.
• 40MBCQ & 40MBCAQ Cassette (p 32)
• 40MBDQ Ducted (p 36)
• 40MBDAQ High Static
Slim Ducted (p 38)
• 40MBFAQ & 40MBFQ Console (p 42)
• 40MBAB Air Handler (p 40)
24 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
38MARB OUTDOOR UNIT
PERFORMANCE:
PERFORMANCE:
PERFORMANCE:
SPECIFICATIONS:
38MARB Outdoor Unit
Heat Pump
System
Size 12 6 9 12 18 24 30 36
Outdoor Model 38MARBQ12AA1 38MARBQ06AA3 38MARBQ09AA3 38MARBQ12AA3 38MARBQ18AA3 38MARBQ24AA3 38MARBQ30AA3 38MARBQ36AA3
Electrical
Voltage-Phase-Cycle V-Ph-Hz 115-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
MCA A. 19 13 15 15 16 25 23 28
MOCP - Fuse Rating A. 25 15 15 15 25 35 30 35
Operating Range
Cooling Outdoor DB Min - Max ° F (° C) -22~122 (-30~50) -22~122 (-30~50) -22~122 (-30~50) -22~122 (-30~50) -22~122 (-30~50) -22~122 (-30~50) -22~122 (-30~50) -22~122 (-30~50)
Heating Outdoor DB Min - Max ° F (° C) -22~86 (-30~30) -22~86 (-30~30) -22~86 (-30~30) -22~86 (-30~30) -22~86 (-30~30) -22~86 (-30~30) -22~86 (-30~30) -22~86 (-30~30)
Piping
Total Piping Length ft (m) 82 (25) 82 (25) 82 (25) 82 (25) 98 (30) 164 (50) 164 (50) 213 (65)
Piping Lift* ft (m) 32 (10) 32 (10) 32 (10) 32 (10) 65 (20) 82 (25) 82 (25) 98 (30)
Pipe Connection Size - Liquid in (mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Pipe Connection Size - Suction in (mm) 1/2 (12.7) 3/8 (9.52) 3/8 (9.52) 1/2 (12.7) 1/2 (12.7) 5/8 (16) 5/8 (16) 5/8 (16)
Refrigerant
Type R410A R410A R410A R410A R410A R410A R410A R410A
Charge in (mm) 2.47 (1.12) 2.38 (1.08) 2.6 (1.18) 2.6 (1.18) 4.08 (1.85) 5.73 (2.6) 6.06 (2.75) 7.50 (3.40)
Compressor
Type Rotary Inverter Rotary Inverter Rotary Inverter Rotary Inverter Rotary Inverter Rotary Inverter Rotary Inverter Rotary Inverter
Outdoor
Unit Width in (mm) 30.12 (765) 30.12 (765) 31.69 (805) 31.69 (805) 35.04 (890) 37.24 (946) 37.24 (946) 37.24 (946)
Unit Height in (mm) 21.85 (555) 21.85 (555) 21.81 (554) 21.81 (554) 26.50 (673) 31.89 (810) 31.89 (810) 31.89 (810)
Unit Depth in (mm) 11.93 (303) 11.93 (303) 12.99 (330) 12.99 (330) 13.46 (342) 16.14 (410) 16.14 (410) 16.14 (410)
Net Weight lbs (kg) 66.80 (30.3) 63.71 (28.9) 74.07 (33.6) 73.63 (33.4) 100.97 (45.8) 134.48 (61) 141.76 (64.3) 150.13 (68.1)
Airflow CFM 794 1,324 1,324 1,324 1,765 2,235 2,235 2,235
Sound Pressure dB(A) 54.0 54.5 54.5 56.0 59.0 62.0 61.5 61.5
26 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
38MARB OUTDOOR UNIT
One-Way 40MCCAQ09XA3 • •
Cassette 40MCCAQ18XA3 • •
40MBDQ09---3
•
40MBDAQ09XH3
40MBDQ12---3
•
40MBDAQ12XH3
Ducted
40MBDQ18---3
•
40MBDAQ18XH3
40MBDQ24---3
• •
40MBDAQ24XH3
40MBDAQ09XH3 •
40MBDAQ12XH3 •
40MBDAQ18XH3 •
High Static
40MBDAQ24XH3 •
Slim Ducted
40MBDAQ36XH3 •
40MBDAQ48XH3 •
40MBDAQ58XH3 •
40MBFAQ12XA3 •
Console 40MBFQ18---3 •
40MBFQ24---3 •
40MBABQ18XB3 •†
40MBABQ24XB3 •†
Air Handler
40MBABQ30XB3 •†
40MBABQ36XB3 •
• Compatible
† Compatible with phased out outdoor unit models starting with serial number: 5122V10319, see TIC 2022-0021 for additional information
Performance™
High Wall
FEATURES Sizes: 06 / 09 / 12 / 18 / 24 / 30 / 36
(208-230V); Size 12 (115V)
• Available in 208/230V (6-36K) or 115V (12K)
• Modes: Cool, Heat, Dry, Fan, Auto
KEY FEATURES
• Turbo Mode
Time-saving Design
• Fully modulating fan speeds The unit disassembles quickly with a removable filter on
• Sleep Mode top for simplified maintenance. The motor and blower can
be serviced without removing the cabinet.
• Up-Down / Left-Right louver control
(fixed or swing) Improved Efficiency & Performance
ECO mode with intelligent eight-hour night cycle program
• ECO Mode saves up to 60% of energy for improved overnight comfort,
• Heating setback (46° F Heating Mode) efficiency and performance.
• Anti-corrosive fin coating Customizable Comfort
Compatible with both single and multi-zone outdoor units
for maximum flexibility.
COMPATIBLE WITH:
• 38MARB Outdoor Unit CONTROLS
Single Zone (p 24)
Wireless Remote Controller included with indoor unit
• 38MGRB & 38MGHB
Outdoor Unit Multi-Zone (p 54) Optional Wired Remote Controller KSACN0801AAA
(7-Day Programmable)
ACCESSORIES
Wi-Fi® Kit KSAIF0601AAA
24V Interface for third-party thermostat compatibility KSAIC0301230
28 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
40MAHB HIGH WALL
SPECIFICATIONS:
COMPATIBILITY:
Indoor Unit 40MAHBQ12XA1 40MAHBQ06XA3 40MAHBQ09XA3 40MAHBQ12XA3 40MAHBQ18XA3 40MAHBQ24XA3 40MAHBQ30XA3 40MAHBQ36XA3
Outdoor Unit Single Zone* 38MARBQ12AA1 38MARBQ06AA3 38MARBQ09AA3 38MARBQ12AA3 38MARBQ18AA3 38MARBQ24AA3 38MARBQ30AA3 38MARBQ36AA3
38MGRQ18B--3
38MGRQ24C--3
Outdoor Unit
38MGRQ30D--3
Multi-Zone*
38MGRQ36D--3
38MGRQ48E--3
*Performance may vary based on the compatible outdoor units. See respective pages for performance data.
Performance™
Cassette
FEATURES Sizes: 06 / 09 / 12 / 18
• Modes: Cool, Heat, Dry, Fan, Auto Select sizes are ENERGY STAR® certified
• Turbo Mode
KEY FEATURES
• Four fan speeds
Flexible Installation
• Sleep Mode
The one-way cassette is designed to be mounted
• ECO Mode between 16" joists for a range of installation applications,
• Quiet indoor operation including corners.
30 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
40MCCAQ ONE-WAY CASSETTE
SPECIFICATIONS:
COMPATIBILITY:
Indoor Unit 40MCCAQ09XA3 40MCCAQ09XA3 40MCCAQ18XA3 40MCCAQ18XA3
Outdoor Unit Single Zone 38MARBQ06AA3 38MARBQ09AA3 38MARBQ12AA3* 38MARBQ18AA3*
38MGRBQ18BA3
38MGHBQ24CA3
38MGHBQ30DA3
Outdoor Unit Multi-Zone 38MGRBQ36DA3
38MGHBQ36DA3
38MGRBQ48EA3
38MGHBQ48EA3
*IDU must be set to the capacity size matching the ODU, refer to the installation instructions for more information.
Performance™
Cassette
FEATURES Sizes: 09 / 12 / 18
• Modes: Cool, Heat, Dry, Fan, Auto
KEY FEATURES
• Auto-restart function
Built-in Condensate Lift Pump
• Louver control (fixed or swing)
The cassette is supplied with a condensate lift pump that is
• Three fan speeds capable of lifting the water 29.5in. (750mm.) above the top
• Outside air intake of the unit.
COMPATIBLE WITH:
• 38MARB Outdoor Unit
Single Zone (p 24)
• 38MGRB & 38MGHB
Outdoor Unit Multi-Zone (p 54)
ACCESSORIES
Wi-Fi® Smartphone control kit KSAIF0401AAA
24V Interface for compatibility with conventional thermostat
KSAIC0301230
Grille is required; sold separately.
32 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
40MBCQ CASSETTE
SPECIFICATIONS:
COMPATIBILITY:
Indoor Unit 40MBCQ09---3 40MBCQ12---3 40MBCQ18---3
Outdoor Unit Single Zone 38MARBQ09AA3 38MARBQ12AA3 38MARBQ18AA3
38MGRQ18B--3
38MGRQ24C--3
Outdoor Unit Multi-Zone 38MGRQ30D--3
38MGRQ36D--3
38MGRQ48E--3
Backward compatible with 38MAQ Single Zone and 38MGQ Multi-Zone Systems
40MBCQ CASSETTE 33
PERFORMANCE™ SERIES
40MBCAQ CASSETTE
Single Zone Residential
Performance™
Cassette
FEATURES Size: 24
• Modes: Cool, Heat, Dry, Fan, Auto, Turbo Select sizes are ENERGY STAR® certified based on
• Louver control (fixed or swing) indoor pairings
34 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
40MBCAQ CASSETTE
SPECIFICATIONS:
Performance may vary based on the Outdoor unit matched to. See compatible Outdoor Units pages for Performance Data
COMPATIBILITY:
Indoor Unit 40MBCAQ24XA3
38MARBQ24AA3
Outdoor Unit Single Zone
38MGRQ30D--3
38MGRQ36D--3
38MGRQ48E--3
38MGHBQ30DA3
Outdoor Unit Multi-Zone
38MGRBQ36DA3
38MGHBQ36DA3
38MGRBQ48EA3
38MGHBQ48EA3
40MBCAQ CASSETTE 35
PERFORMANCE™ SERIES
40MBDQ DUCTED
Single Zone Residential
Performance™
Ducted
FEATURES Sizes: 09 / 12 / 18 / 24
• Modes: Cool, Heat, Dry, Fan, Auto
KEY FEATURES
• Vertical or horizontal installation
Vertical or Horizontal Installation
• Up to 0.64 in W.C.
Designed for maximum installation flexibility.
• Rear or bottom return The secondary drain built-in allows the unit to be mounted
• Outside air intake vertically allowing either a floor or ceiling-concealed
installation depending on existing conditions.
• Follow Me (senses temperature at
handheld remote) Flexible Air Intake
Air inlet can be installed either at the back or the bottom of
• Heating setback (46°F Heating Mode) the unit due to the small plate size on the flange, allowing
• Quiet indoor operation, as low as 30 dB(A) for flexible installation to meet the needs of each job.
• Anti-corrosive fin coating
CONTROLS
• E xternal condensate lift pump shipped
with the unit (sizes 09-18) Wireless Remote Controller included with indoor unit
• Built-in condensate lift pump (size 24) Wired Remote Controller KSACN0701AAA
included with indoor unit (7-Day Programmable)
COMPATIBLE WITH:
• 38MARB Outdoor Unit
Single Zone (p 24)
• 38MGRB & 38MGHB
Outdoor Unit Multi-Zone (p 54)
ACCESSORIES
Wi-Fi® kit KSAIF0401AAA
24V Interface for compatibility with conventional
thermostat KSAIC0301230
36 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
40MBDQ DUCTED
SPECIFICATIONS:
Performance may vary based on the compatible outdoor units. See respective pages for performance data.
COMPATIBILITY:
Indoor Unit 40MBDQ09---3 40MBDQ12---3 40MBDQ18---3 40MBDQ24---3
Outdoor Unit Single Zone 38MARBQ09AA3 38MARBQ12AA3 38MARBQ18AA3 38MARBQ24AA3
38MGRQ18B--3
38MGRQ24C--3
Outdoor Unit Multi-Zone 38MGRQ30D--3
38MGRQ36D--3
38MGRQ48E--3
40MBDQ DUCTED 37
PERFORMANCE™ SERIES
40MBDAQ HIGH STATIC SLIM DUCTED
Single Zone Residential
Performance™
Slim Ducted
FEATURES Sizes: 09 / 12 / 18 / 24
• Vertical or horizontal installation (Except 58K)
KEY FEATURES
• External static pressures of up to 0.80 in W.C.
Discrete Design
• Constant air volume control
A slim duct design, recessed installation and exterior
• Modes: Cool, Heat, Dry, Fan, Auto connection via flexible refrigerant tubing allow this unit
• Rear or bottom return to integrate seamlessly into existing architecture and
new construction.
• Outside air intake
Improved Indoor Air Quality
• Built-in condensate lift pump Each unit comes equipped with a washable, reusable filter
• Follow Me (senses temperature for simple, cost-effective servicing. And with the ability
at handheld remote) to accommodate filters rated up to MERV 13, customers
can benefit from the gold standard in indoor air quality
• Quiet indoor operation, as low as 35 dB(A) technology without sacrificing performance or efficiency.
ACCESSORIES
Wi-Fi® kit KSAIF0401AAA
24V Interface Kit 230V KSAIC0301230
38 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
40MBDAQ HIGH STATIC SLIM DUCTED
SPECIFICATIONS:
Performance may vary based on the compatible outdoor units. See respective pages for performance data.
COMPATIBILITY:
Indoor Unit 40MBDAQ09XH3 40MBDAQ12XH3 40MBDAQ18XH3 40MBDAQ24XH3
Outdoor Unit Single Zone 38MARBQ09AA3 38MARBQ12AA3 38MARBQ18AA3 38MARBQ24AA3
38MGHBQ24CA3
38MGHBQ30DA3
38MGRBQ36DA3
Outdoor Unit Multi-Zone
38MGHBQ36DA3
38MGRBQ48EA3
38MGHBQ48EA3
Performance™
Air Handler
FEATURES Size: 18 / 24 / 30 / 36
• Modes: Cool, Heat, Dry, Fan, Auto
Select sizes are ENERGY STAR® certified based
• 4-way installation (Up flow, Down flow, on indoor pairings
Right, Left)
• New aluminum coil KEY FEATURES
• Automatic Airflow Technology with static Unmatched Maintenance Simplicity
pressure up to 0.8 in W.C. With a top panel and an indoor coil that can be easily
• Less than 2% air leakage removed, get faster access to the core parts of the unit
needed for service. You only need to remove two screws!
• Easy maintenance
Less Complex Electronics
• Quiet indoor operation Having only two integrated printed circuit boards
• Anti-corrosive fin coating means the electronic components are less complicated.
One is the main control board, and the other is the
function board for the 24V Interface, dip switch, wired
COMPATIBLE WITH: controller and LED display.
• 38MARB Outdoor Unit Easier Access to Electric Heater
Single Zone (p 24) This single-piece construction enables easy installation
• 38MGRB & 38MGHB and maintenance.
Outdoor Unit Multi-Zone (p 54) Modular Slide Design
The indoor coil can be easily pulled out through the slide
track for quick and easy maintenance.
CONTROLS
Wireless Remote Controller included with indoor unit
24V Interface for third party thermostat compatibility
built-in
WARRANTY
Limited Warranty*
10-year limited to original purchaser on compressor and
parts upon timely registration, otherwise 5 years.
40 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
40MBAB AIR HANDLER
SPECIFICATIONS:
*Performance may vary based on the compatible outdoor units. See respective pages for performance data.
COMPATIBILITY:
Indoor Unit 40MBABQ18XB3 40MBABQ24XB3 40MBABQ30XB3 40MBABQ36XB3
Outdoor Unit Single Zone 38MARBQ18AA3 38MARBQ24AA3 38MARBQ30AA3 38MARBQ36AB3
38MGHBQ24CA3
38MGHBQ30DA3 38MGHBQ30DA3
38MGRBQ36DA3 38MGRBQ36DA3
Outdoor Unit Multi-Zone
38MGHBQ36DA3 38MGHBQ36DA3
38MGRBQ48EA3 38MGRBQ48EA3 38MGRBQ48EA3 38MGRBQ48EA3
38MGHBQ48EA3 38MGHBQ48EA3 38MGHBQ48EA3 38MGHBQ48EA3
Manufacturer reserves the right to discontinue, or change at any time, specification or designs without notice or incurring obligations.
Multi-Zone configuration:
Performance™
Console Sizes 18 & 24
40MBFQ
Optional Wireless
Wired Controller Remote
(7-Day Programmable) Controller
KSACN0601AAA or
KSACN0701AAA
ACCESSORIES
Wi-Fi® kit KSAIF0401AAA (sizes 18–24)
24V Interface for compatibility with conventional
thermostat KSAIC0301230
42 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
40MBFAQ & 40MBFQ CONSOLE
SPECIFICATIONS:
Performance may vary based on the compatible outdoor units. See respective pages for performance data.
COMPATIBILITY:
Indoor Unit 40MBFAQ12---3 40MBFQ18---3 40MBFQ24---3
Outdoor Unit Single Zone 38MARBQ12AA3 38MARBQ18AA3 38MARBQ24AA3
38MGRQ18B--3
38MGRQ24C--3
Outdoor Unit Multi-Zone 38MGRQ30D--3
38MGRQ36D--3
38MGRQ48E--3
Backward compatible with 38MAQ Single Zone and 38MGQ Multi-Zone Systems
Comfort™
Heat Pump
FEATURES Cooling Only — 38MHRDC
• Cost competitive Sizes: 09 / 12 / 18 / 24
• Built-in basepan heater Heat Pump — 38MHRCQ
• Auto-restart function Sizes: 09 / 12 / 18 / 24 / 30 / 36
• Condenser high-temperature protection Up to 21.5 SEER2
• Refrigerant leakage detection (Size 9K only)
44 COMFORT™ SERIES
COMFORT™SERIES
38MHRDC & 38MHRCQ OUTDOOR UNIT
SPECIFICATIONS:
COMPATIBILITY:
Outdoor Unit
Indoor Unit
38MHRCQ09AA1 38MHRCQ12AA1 38MHRCQ09AA3 38MHRCQ12AA3 38MHRCQ18AA3 38MHRCQ24AA3 38MHRCQ30AA3 38MHRCQ36AA3
40MHHAQ09XA1 •
40MHHAQ12XA1 •
40MHHAQ09XA3 •
40MHHAQ12XA3 •
High Wall
40MHHAQ18XA3 •
40MHHAQ24XA3 •
40MHHAQ30XA3 •
40MHHAQ36XA3 •
PERFORMANCE:
40MHHAC High Wall
Cooling Only
Indoor Unit 40MHHAC09XA3 40MHHAC12XA1 40MHHAC12XA3 40MHHAC18XA3 40MHHAC24XA3
Outdoor Model 38MHRDC09AA3 38MHRDC12AA1 38MHRDC12AA3 38MHRDC18AA3 38MHRDC24AA3
Cooling Rated Capacity Btu/h 9,000 12,000 12,000 18,000 24,000
Cooling System Tons 0.75 1.0 1.0 1.5 2.0
Cooling Cap. Range Min - Max Btu/h 2800~11000 3300~12500 3030~12500 4200~18300 4700~23600
SEER2 20.5 21 21 21 20
EER2 12.5 11.9 12.0 11.3 10.2
46 COMFORT™ SERIES
COMFORT™ SERIES
38MHR OUTDOOR UNIT
SPECIFICATIONS:
* Permissible limits of the voltage range at which the unit will operate satisfactorily
** Condensing unit above or below indoor unit
COMPATIBILITY:
Outdoor Unit
Indoor Unit
38MHRDC09AA3 38MHRDC12AA1 38MHRDC12AA3 38MHRDC18AA3 38MHRDC24AA3
40MHHAC09XA3 •
40MHHAC12XA1 •
High Wall 40MHHAC12XA3 •
40MHHAC18XA3 •
40MHHAC18XA3 •
Comfort™
High Wall
FEATURES Cooling Only - 40MHHAC
• Available in 115V and 208/230V Sizes: 09 / 12 / 18 / 24
• Modes: Cool, Heat, Dry, Fan, Auto Heat Pump - 40MHHAQ
• Turbo Mode Sizes: 09 / 12 / 18 / 24 / 30 / 36
• Up-down right-left louver control
(fixed or swing) KEY FEATURES
• Four fan speeds Improved Serviceability
Full access to the terminal connections and fan after
• ECO Mode
lifting the front cover of the high wall for easy installation
• Anti-corrosive fin coating and service.
Eco Mode
COMPATIBLE WITH: An intelligent eight-hour night cycle program provides
huge energy savings—up to 60%—while maintaining a
• 38MHRDC & 38MHRCQ
comfortable sleeping environment.
Outdoor Unit Single Zone (p 44)
• 38MGRB & 38MGHB
Outdoor Unit Multi-Zone (p 54) CONTROLS
Wireless Remote Controller included with indoor unit
Optional Wired Remote Controller (7-Day Programmable)
Optional Wired Remote Controller with Timer Function
ACCESSORIES
Wi-Fi® kit KSAIF0601AAA
24V Interface for compatibility with conventional
thermostat KSAIC0301230
48 COMFORT™ SERIES
COMFORT™ SERIES
40MHHAC & 40MHHAQ HIGH WALL
SPECIFICATIONS:
Performance may vary based on the compatible outdoor units. See respective pages for performance data.
Performance may vary based on the compatible outdoor units. See respective pages for performance data.
50 COMFORT™ SERIES
COMFORT™ SERIES
40MHHA HIGH WALL
COMPATIBILITY:
COMPATIBILITY:
Heat Pump
Indoor Unit 40MHHAQ09XA1 40MHHAQ12XA1 40MHHAQ09XA3 40MHHAQ12XA3 40MHHAQ18XA3 40MHHAQ24XA3 40MHHAQ30XA3 40MHHAQ36XA3
38MGRQ18B--3
38MHRCQ12AA1
38MHRCQ09AA3
Outdoor Unit 38MHRCQ12AA3
Single Zone 38MHRCQ18AA3
38MHRCQ24AA3
38MHRCQ30AA3
38MHRCQ36AA3
52
Multi-Zone Ductless
38MGRB & 38MGHB Outdoor Unit
Up to 26.0 SEER2
Up to 10.5 HSPF2
Sizes: 18 / 24HH / 30HH /
36 / 36HH / 48 / 48HH
Multi-Zone VRF
MMYF-1P Heat
Recovery System
Sizes: 72 / 144
MCY7 Heat
Pump System
Sizes: 36 / 48 / 60
53
PERFORMANCE™ SERIES
38MGRB & 38MGHB OUTDOOR UNIT
High Performance
Multi-Zone Ductless
Outdoor Unit
for Customizable
Indoor Comfort
FEATURES Heat Pump With Basepan Heater
• Cost competitive Inverter Compressor
• Built-in base pan heater Sizes: 18 / 24HH / 30HH / 36 / 36HH / 48 / 48HH
• Auto-restart function Up to 26.0 SEER2
• Quiet outdoor operation, as low as 59 dB(A) Up to 10.5 HSPF2
• Anti-corrosive fin coating Select systems are ENERGY STAR® certified based on indoor pairings
54 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
38MGRB & 38MGHB OUTDOOR UNIT
SPECIFICATIONS:
Multi-Zone Ductless
38MGRB & 38MGHB Outdoor Unit
Heat Pump
System
Size 18R 24HH 30HH 36R 36HH 48R 48HH
Outdoor Model 38MGRBQ18BA3 38MGHBQ24CA3 38MGHBQ30DA3 38MGRBQ36DA3 38MGHBQ36DA3 38MGRBQ48EA3 38MGHBQ48EA3
Max Number of Zones 2 3 4 4 4 5 5
Operating Range
Cooling Outdoor
° F (° C) 5~122 (-15~50) 5~122 (-15~50) 5~122 (-15~50) 5~122 (-15~50) 5~122 (-15~50) 5~122 (-15~50) 5~122 (-15~50)
DB Min - Max
Heating Outdoor
° F (° C) 13~75 (-30~24) -22~75 (-30~24) -22~75 (-30~24) 13~75 (-30~24) -22~75 (-30~24) 13~75 (-30~24) -22~75 (-30~24)
DB Min - Max
Piping
Total Piping Length ft (m) 131 (40) 197 (60) 262 (80) 262 (80) 262 (80) 328 (100) 328 (100)
Piping to furthest FCU ft (m) 82 (25) 98 (30) 115 (35) 115 (35) 115 (35) 115 (35) 115 (35)
Drop (OD above ID) ft (m) 49 (15) 49 (15) 49 (15) 49 (15) 65 (20) 65 (20) 65 (20)
Lift (OD below ID) ft (m) 49 (15) 49 (15) 49 (15) 49 (15) 65 (20) 65 (20) 65 (20)
1/4*2 1/4*3 1/4*4 1/4*4 1/4*4 1/4*5 1/4*5
Pipe Connection Size - Liquid in (mm)
(6.35*2) (6.35*3) (6.35*4) (6.35*4) (6.35*4) (6.35*5) (6.35*5)
Pipe Connection Size - 3/8*2 3/8*3 1/2 *1+ 3/8*3 1/2 *1+ 3/8*3 1/2 *2+ 3/8*2 1/2 *2+ 3/8*3 1/2 *2+ 3/8*3
in (mm)
Suction (9.52*2) (9.52*3) (12.7*1+9.52*3) (12.7*1+9.52*3) (12.7*2+9.52*2) (12.7*2+9.52*3) (12.7*2+9.52*3)
Refrigerant
Type R410A R410A R410A R410A R410A R410A R410A
Charge lbs (kg) 4.08 (1.85) 5.73 (2.6) 8.38 (3.8) 8.38 (3.8) 10.14 (4.6) 10.14 (4.6) 10.14 (4.6)
Electrical
Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
Power Supply Indoor unit powered from outdoor unit
MCA A. 18 24.5 25 25 40 40 40
Recommended Fuse Size A. 20 25 30 30 45 45 45
MOCP - Fuse Rating A. 25 30 40 40 60 60 60
Compressor
Type Rotary Inverter Rotary Inverter Rotary Inverter Rotary Inverter Rotary Inverter Rotary Inverter Rotary Inverter
Outdoor
Unit Width in (mm) 35.04 (890) 37.24 (946) 37.24 (946) 37.24 (946) 37.48 (952) 37.48 (952) 37.48 (952)
Unit Height in (mm) 26.50 (673) 31.89 (810) 31.89 (810) 31.89 (810) 52.48 (1333) 52.48 (1333) 52.48 (1333)
Unit Depth in (mm) 13.46 (342) 16.14 (410) 16.14 (410) 16.14 (410) 16.34 (415) 16.34 (415) 16.34 (415)
Net Weight lbs (kg) 100.31 (45.5) 139.77 (63.4) 169.09 (76.7) 169.09 (76.7) 223.1 (101.2) 225.5 (102.3) 238.32 (108.1)
Airflow CFM 1,765 2,129 2,147 2,147 4,500 4,500 4,500
Sound Pressure dB(A) 59 61 63 63 64 64 65
Non-Ducted
Size 18R 24HH 30HH 36R 36HH 48R 48HH
Outdoor Model 38MGRBQ18BA3 38MGHBQ24CA3 38MGHBQ30DA3 38MGRBQ36DA3 38MGHBQ36DA3 38MGRBQ48EA3 38MGHBQ48EA3
Max Number of Zones 2 3 4 4 4 5 5
ENERGY STAR® YES YES YES NO YES YES NO
Cooling System Tons 1.5 2.0 2.5 3.0 3.0 4.0 4.0
Cooling Rated Capacity Btu/h 18,000 24,000 30,000 36,000 36,000 48,000 48,000
Cooling Cap. Range Min - Max Btu/h 5,650~22,000 9,573~32,100 9,429~40,800 8,209~40,555 17,900~42,000 19,000~50,000 19,300~51,000
SEER2 22.9 24.6 26.0 23.9 22.2 23.4 21.8
EER2 13.9 13.4 13.0 11.7 13.6 12.5 11.7
Heating Rated Capacity (47° F) Btu/h 19,000 25,000 30,000 37,000 36,500 48,000 49,000
Heating Maximum Capacity
Btu/h 12,400 23,000 29,400 23,900 36,000 36,000 48,000
(5° F)
Heating Cap. Range Min - Max Btu/h 5,050~24,400 8,439~33,930 8,118~41,400 8,008~44,632 12,500~49,000 12,500~52,000 11,500~58,000
HSPF2 10.5 10.0 9.8 9.5 10.5 8.7 9.8
COP (47° F) W/W 3.92 4.10 3.81 3.61 3.85 3.60 3.59
COP (5° F) - Maximum W/W 1.75 1.75 1.90 1.75 1.75 1.75 2.00
PERFORMANCE:
Ducted
Size 18R 24HH 30HH 36R 36HH 48R 48HH
Outdoor Model 38MGRBQ18BA3 38MGHBQ24CA3 38MGHBQ30DA3 38MGRBQ36DA3 38MGHBQ36DA3 38MGRBQ48EA3 38MGHBQ48EA3
Max Number of Zones 2 3 4 4 4 5 5
ENERGY STAR® NO YES NO NO NO NO NO
Cooling System Tons 1.5 2.0 2.5 3.0 3.0 4.0 4.0
Cooling Rated Capacity Btu/h 18,000 24,000 30,000 36,000 36,000 48,000 48,000
Cooling Cap. Range Min - Max Btu/h 3,850~22,400 6,193~30,697 8,124~38,500 8,789~40,288 17,400~44,000 19,400~51,000 18,500~51,000
SEER2 19.0 21.3 20.0 20.0 19.0 20.5 20.9
EER2 12.0 12.5 12.0 11.0 11.7 10.8 11.7
Heating Rated Capacity (47° F) Btu/h 19,000 24,000 30,000 37,000 37,000 50,000 50,000
Heating Maximum Capacity
Btu/h 13,000 21,500 28,600 24,000 36,000 36,000 48,000
(5° F)
Heating Cap. Range Min - Max Btu/h 4,350~25,800 7,394~33,700 6,652~43,200 6,900~46,624 13,300~47,000 15,500~56,000 12,000~59,000
HSPF2 9.8 9.7 9.2 9.2 10.0 9.7 8.9
COP (47° F) W/W 3.80 3.81 3.81 3.60 3.74 3.57 3.86
COP (5° F) - Maximum W/W 1.75 1.95 1.85 1.68 1.80 1.80 1.85
56 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
38MGRB & 38MGHB OUTDOOR UNIT
PERFORMANCE:
Multi-Zone Ductless
Combination Ducted and Non-Ducted
Size 18R 24HH 30HH 36R 36HH 48R 48HH
Outdoor Model 38MGRBQ18BA3 38MGHBQ24CA3 38MGHBQ30DA3 38MGRBQ36DA3 38MGHBQ36DA3 38MGRBQ48EA3 38MGHBQ48EA3
Max Number of Zones 2 3 4 4 4 5 5
ENERGY STAR® YES YES NO NO YES NO NO
Cooling System Tons 1.5 2.0 2.5 3.0 3.0 4.0 4.0
Cooling Rated Capacity Btu/h 18,000 24,000 30,000 36,000 36,000 48,000 48,000
Cooling Cap. Range Min - Max Btu/h 4,750~22,200 7,883~31,399 8,777~39,650 8,499~40,422 17,500~43,000 19,200~50,500 18,900~51,000
SEER2 20.9 22.9 23.0 21.95 20.6 21.9 21.3
EER2 12.9 12.9 12.5 11.35 12.6 11.6 11.7
Heating Rated Capacity (47° F) Btu/h 19,000 24,500 30,000 37,000 36,750 49,000 49,500
Heating Maximum Capacity (5° F) Btu/h 12,700 22,000 29,000 23,900 36,000 36,000 48,000
Heating Cap. Range Min - Max Btu/h 4,700~25,100 7,917~33,815 7,385~42,300 7,454~45,628 12,900~48,000 14,000~54,000 11,750~58,500
HSPF2 10.1 9.8 9.5 9.35 10.1 9.2 9.3
COP (47° F) W/W 3.86 3.96 3.81 3.61 3.80 3.59 3.73
COP (5° F) - Maximum W/W 1.75 1.85 1.88 1.72 1.80 1.80 1.90
Single-Phase
VRF Heat Pump
FEATURES VRF Heat Pump System
• Up to 19.2 SEER2 Sizes: 36K / 48K / 60K
• Up to 9.2 HSPF2 36,000 to 60,000 Btu/h
• 208/230-1-60Hz power supply 3 to 5 tons
• Connect up to nine multiple- style indoor
units on a 5-ton system KEY FEATURES
• High-performance outdoor unit with The Carrier 38VMB-H VRF heat pump system is a combination
inverter-driven scroll compressor of an outdoor unit with multiple-style indoor units connected
by refrigerant piping and wiring. The outdoor units have stacked
• Cooling operating range 5° ~ 118° F
dual-condenser fan with side-blow arrangement.
• Heating operating range -13° ~ 64° F
• Connected capacity up to 130%
• Quiet outdoor operation, as low as 58.7 dB(A)
COMPATIBLE WITH:
40VMA, 40VMF, 40VMH, 40VML, 40VMM,
40VMR, 40VMU, 40VMV, 40VMW, 40VMC,
40VMI & 40VM9 (controller)
Multi-Zone VRF
38VMB-H Outdoor Unit
System
Outdoor Unit Model Name 38VMB036HDS3-1 38VMB048HDS3-1 38VMB060HDS3-1
Nominal Tons Ton 3 4 5
Performance
Cooling Capacity (*1) Nominal kBtu/h 36,000 48,000 60,000
(with non-ducted indoor units/ducted) Rated kBtu/h 36,000 48,000 60,000
Heating Capacity (*1) Nominal kBtu/h 40,000 52,500 66,000
(with non-ducted indoor units/ducted) Rated kBtu/h 40,000 52,500 66,000
Performance Non-Ducted
With Non-Ducted Power Supply (*2) 208/230V, 1-Phase, 60Hz
Indoor Units Power Consumption kW 3.1 4.6 6.1
Cooling
SEER2 (Seasonal Energy Efficiency Ratio) Btu/W*hr 19.2 19.0 18.6
Electrical Power Consumption kW 3.1 4.3 5.8
Characteristics Heating HSPF2 (Heating Seasonal
(Nominal) (*1) Btu/W*hr 9.2 8.9 8.7
Performance Factor)
Performance Ducted
With Ducted Power Supply (*2) 208/230V, 1-Phase, 60Hz
Indoor Units Power Consumption kW 2.9 4.7 6.1
Cooling
SEER2 (Seasonal Energy Efficiency Ratio) Btu/W*hr 17.3 17.0 15.9
Electrical Power Consumption kW 3 .0 4.2 5.7
Characteristics Heating HSPF2 (Heating Seasonal
(Nominal) (*1) Btu/W*hr 9.1 8.5 8.0
Performance Factor)
Dimensions
Height in 52-1/4
Width in 35-1/2
Depth in 15-3/4
Total Weight Unit lb 220
Compressor
Type/Quantity Inverter-Driven Hermetic Rotary/1
Motor Output kW 13
Fan Unit
Motor Output W 90+90
Air Volume cfm 4,100
Refrigerant (*3) (charged refrigerant amount) lb 8.6
Electrical MCA (*4) A 36 38 40
Unit
Specifications Recommended Fuse Size A 40 40 45
Piping
Refrigerant Connecting Port Gas Side (main pipe) (brazing) in 5/8 3/4
Piping Diameter Liquid Side (main pipe) (brazing) in 3/8
Operation Temperature Range
o
Cooling F DB 5~118
o
Heating F WB -13~64
Indoor
Maximum Number of Connected Indoor Units 5 7 9
Maximum Capacity of Combined Indoor Units 50 to 130%
Sound Pressure Level Cooling/Heating (*5) dB(A) 58.7 60.1 60.7
Toshiba Carrier
VRF Heat
Recovery
FEATURES 3-Pipe VRF Heat Recovery System
• Available in 6-ton single module which can 72,000 or 144,000 Btu/h
be twinned up to 12-ton capacity 6 or 12 tons
• Ability to connect up to 25 indoor units
• High-performance outdoor units with all KEY FEATURES
inverter-driven twin rotary compressor The Toshiba Carrier VRF system is a combination of an
• DC inverter condenser fan motor outdoor unit with multiple-style indoor units connected
by refrigerant piping and wiring. The VRF heat recovery
• 208/230-1-60Hz voltage
outdoor unit is a single module with twinning capability up
• Cooling ambient operating temperature to 12 tons to achieve greater capacity.
is 14° ~ 122° F
• Heating ambient operating temperature
is -13° ~ 60° F
• Connected capacity up to 150%
COMPATIBLE WITH:
The MMYF-SP heat recovery unit is matched with
multiple VRF fan coils.
60 TOSHIBA CARRIER
TOSHIBA CARRIER
MMYF-1P HEAT RECOVERY SYSTEM
SPECIFICATIONS:
Multi-Zone VRF
MMYF-1P Outdoor Unit
System
Outdoor Unit Set Model Name MMY- AP1446FT2P-UL
MAP0726FT2P-UL 0726FT2P-UL
Outdoor Unit Model Name MMY-MAP
0726FT2P-UL
Nominal Tons Ton 6 12
Performance
Cooling Capacity (*1) Nominal kBtu/h 72 144
(with non-ducted indoor units/ducted) Rated kBtu/h 69 138
Heating Capacity (*1) Nominal kBtu/h 81 162
(with non-ducted indoor units/ducted) Rated kBtu/h 77 154
Performance Non-Ducted
With Non-ducted Power Supply (*2) 208/230V, 1-Phase, 60Hz
Indoor Units Power Consumption (*6) kW 4.43 9.65
Cooling
IEER (Integrated Energy Efficiency Ratio) Btu/W*hr 27.4 25.7
Electrical Power Consumption (*6) kW 5.98 11.69
Characteristics Heating SCHE (Simultaneous Cooling &
(Nominal) (*1) Btu/W*hr 30.6 31.3
Heating Efficiency)
Performance Ducted
With Ducted Power Supply (*2) 208/230V, 1-Phase, 60Hz
Indoor Units Power Consumption (*6) kW 4.88 9.81
Cooling
IEER (Integrated Energy Efficiency Ratio) Btu/W*hr 20.6 20.0
Electrical Power Consumption (*6) kW 6.10 11.56
Characteristics Heating SCHE (Simultaneous Cooling &
(Nominal) (*1) Btu/W*hr 27.8 26.6
Heating Efficiency)
Dimensions
Height in 72.9 72.9
Width in 39.0 39.0 x 2
Depth in 30.7 30.7
Total Weight Unit lb 600 600 + 600
Compressor
Type Hermetic Twin Rotary Compressor
Fan Unit
Air Volume cfm 5,900 5,900 x 2
Maximum External Static Pressure in W.C. 0.24 0.24
Refrigerant (*3) (charged refrigerant amount) lb 24.3 24.3 x 2
Electrical MCA (*4) A 47 47 + 47
Unit
Specifications Recommended Fuse Size A 50 50 + 50
Piping
Gas Side (main pipe) (brazing) in 7/8 1-1/8
Refrigerant Connecting Port Liquid Side (main pipe) (flare) in 1/2 5/8
Piping Diameter Discharge (main pipe) (flare) in 3/4 7/8
Balance Pipe (flare) in 3/8 3/8
Operation Temperature Range
Cooling º F DB 14~122
Heating º F WB -13~60
Indoor
Maximum Number of Connected Indoor Units 12 25
Maximum Capacity of Combined Indoor Units 50 to 150%
Sound Pressure Level Cooling/Heating (*5) dB(A) 57/60 60/63
Toshiba
Multi-Zone VRF
Carrier VRF
Single-Phase
Heat Pump
FEATURES VRF Heat Pump System
• Ability to connect up to nine multiple-style 36,000 to 60,000 Btu/h
indoor units on a 5-ton system 3 to 5 tons
• High-performance outdoor unit with
inverter-driven twin rotary compressor KEY FEATURES
• 208/230-1-60Hz power supply The Toshiba Carrier VRF System is a combination of an
• Cooling operating range 23° ~ 122° F outdoor unit with multiple-style indoor units connected
by refrigerant piping and wiring. The outdoor units have
• Heating operating range -13° ~ 60° F
stacked dual-condenser fan with side-blow arrangement.
• Connected capacity up to 135%
• Up to 23.1 SEER2 cooling efficiency
• Up to 10.9 HSPF2 heating efficiency
• Quiet outdoor operation
COMPATIBLE WITH:
The MCY7 heat pump is matched
with multiple VRF fan coils.
62 TOSHIBA CARRIER
TOSHIBA CARRIER
MCY7 HEAT PUMP SYSTEM
SPECIFICATIONS:
Multi-Zone VRF
MCY7 Outdoor Unit
System
Outdoor Unit Model Name MCY- MAP0367HS-UL MAP0487HS-UL MAP0607HS-UL
Nominal Tons Ton 3 4 5
Performance
Cooling Capacity (*1)
Nominal kBtu/h 36 48 60
(with non-ducted indoor units/ducted)
Heating Capacity (*1)
Nominal kBtu/h 40 54 66
(with non-ducted indoor units/ducted)
Performance Non-Ducted
Power Supply (*2) 208/230V, 1-Phase, 60Hz
With Non-Ducted Power Consumption kW 2.29 3.71 5.26
Indoor Units Cooling
EER (Energy Efficiency Ratio) Btu/W*hr 15.7 12.95 11.4
Power Consumption kW 2.79 3.95 5.16
Electrical Heating
Characteristics COP (Coefficient of Performance) Btu/W*hr 4.20 4.01 3.75
(Nominal) (*1) SEER2 (Seasonal Energy Efficiency Ratio) 22.8 21.1 23.1
HSPF2 (Heating Seasonal Performance Ratio) 10.9 9.4 10.6
Performance Ducted
Power Supply (*2) 208/230V, 1-Phase, 60Hz
With Ducted Power Consumption kW 2.76 4.87 5.76
Indoor Units Cooling
EER (Energy Efficiency Ratio) Btu/W*hr 13.05 9.85 10.42
Power Consumption kW 3.45 5.27 5.34
Electrical Heating
Characteristics COP (Coefficient of Performance) Btu/W*hr 3.40 3.0 3.62
(Nominal) (*1) SEER2 (Seasonal Energy Efficiency Ratio) 20.1 17.2 18.4
HSPF2 (Heating Seasonal Performance Ratio) 10.0 9.5 9.8
Dimensions
Height in 61 61 61
Width in 39.8 39.8 39.8
Depth in 14.6 14.6 14.6
Total Weight Unit lb 311 311 311
Compressor
Type Hermetic Twin Rotary Compressor
Motor Output kW 3.75 3.75 3.75
Fan Unit
Air Volume cfm 4,520 4,690 4,850
Refrigerant R410A (*3) (charged refrigerant amount) lb 14.8 14.8 14.8
Electrical MCA (*4) A 36.3 36.3 36.3
Unit
Specifications Recommended Fuse Size A 40 40 40
Piping
Refrigerant Connecting Port Gas Side (main pipe) (brazing) in 5/8 5/8 3/4
Piping Diameter Liquid Side (main pipe) (brazing) in 3/8 3/8 3/8
Operation Temperature Range
o
Cooling F DB 23~122
o
Heating F WB -13~60
Indoor
Maximum Number of Connected Indoor Units 6 8 9
Maximum Capacity of Combined Indoor Units 80 to 135% 80 to 135% 50 to 135%
Sound Pressure Level Cooling/Heating (*5) dB(A) 52/56 54/57 55/58
64
38MBRC Outdoor Unit
Up to 19.8 SEER2
Up to 10.2 HSPF2
Sizes: 36 / 48 / 58
40MBCAQ Cassette
Sizes: 36 / 48
40MBDQ Ducted
Sizes: 36 / 48 / 58
40MBFQ Console
Sizes: 36 / 48 / 58
65
PERFORMANCE™ SERIES
38MBRC OUTDOOR UNIT
Light Commercial
An Efficient
Outdoor Unit with
36K 48K/58K
Easy Maintenance
FEATURES Outdoor Heat Pump Unit
• Variable speed compressor Inverter Compressor
• High efficiency ECM fan motor Sizes: 36 / 48 / 58
• Factory installed base pan heater Up to 19.8 SEER2
• Factory installed crankcase heater Up to 10.2 HSPF2
• Low voltage controls
• Auto-restart function KEY FEATURES
• Condenser high temperature protection Premium Efficiency
Enjoy increased energy savings with a unit equipped
• Quiet operation with inverter technology that delivers first-rate comfort
• Anti-corrosive fin coating and efficiency.
Simple Maintenance
COMPATIBLE WITH: With convenient access to the control compartment
through both top and side panels, this outdoor unit
• 40MBCAQ Cassette (p 70) makes servicing and maintenance a breeze.
• 40MBDQ Ducted (p 72)
• 40MBDAQ High Static
Slim Ducted (p 74)
• 40MBFQ Console (p 76)
• 40MBAB Air Handler (p 78)
66 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
38MBRC OUTDOOR UNIT
SPECIFICATIONS:
Light Commercial
38MBRC Outdoor Unit
Heat Pump
System
Size 36K 48K 58K
Outdoor Model 38MBRCQ36AA3 38MBRCQ48AA3 38MBRCQ58AA3
Electrical
Voltage-Phase-Cycle V-Ph-Hz 208/230-1-60 208/230-1-60 208/230-1-60
MCA A. 30 35 35
MOCP - Fuse Rating A. 50 50 50
Operating Range
Cooling Outdoor DB Min - Max ° F (° C) -22~130 (-30~55) -22~130 (-30~55) -22~130 (-30~55)
Heating Outdoor DB Min - Max ° F (° C) -22~86 (-30~30) -22~86 (-30~30) -22~86 (-30~30)
Piping
Total Piping Length ft (m) 213 (65) 213 (65) 213 (65)
Piping Lift* ft (m) 98 (30) 98 (30) 98 (30)
Pipe Connection
in (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Size - Liquid
Pipe Connection
in (mm) 5/8 (16) 5/8 (16) 7/8 (22)
Size - Suction
Refrigerant
Type R410A R410A R410A
Charge lbs (kg) 6.72 (3.05) 9.26 (4.2) 10.58 (4.8)
Compressor
Type Rotary Inverter Rotary Inverter Rotary Inverter
Dimensions
Unit Width in (mm) 37.24 (946) 37.48 (952) 37.48 (952)
Unit Height in (mm) 31.89 (810) 52.48 (1333) 52.48 (1333)
Unit Depth in (mm) 16.14 (410) 16.34 (415) 16.34 (415)
Net Weight lbs (kg) 148.59 (67.4) 219.14 (99.4) 217.15 (98.5)
Airflow CFM 2,130 4,500 4,500
Sound Pressure dB(A) 63 62.5 61.2
*Condensing unit above or below indoor unit.
COMPATIBILITY:
Outdoor Unit
Indoor Unit
38MBRCQ36AA3 38MBRCQ48AA3 38MBRCQ58AA3
40MBABQ36XA3 •
Air Handler 40MBABQ48XA3 •
40MBABQ60XA3 •
40MBCAQ36XA3 •
Cassette
40MBCAQ48XA3 •
40MBFQ36---3 •
Console 40MBFQ48---3 •
40MBFQ58---3 •
40MBDQ36---3 •
Ducted 40MBDQ48---3 •
40MBDQ58---3 •
40MBDAQ36XH3 •
High Static
40MBDAQ48XH3 •
Slim Ducted
40MBDAQ58XH3 •
PERFORMANCE:
40MBCAQ Cassette
Size 36K 48K
Indoor Model 40MBCAQ36XA3 40MBCAQ48XA3
Cooling System Tons 3.0 4.0
Cooling Rated Capacity Btu/h 36,000 48,000
Cooling Cap. Range Min - Max Btu/h 12,400~36,000 16,600~48,000
SEER2 19.2 18.5
EER2 9.4 9.5
Heating Rated Capacity (47° F) Btu/h 38,000 50,000
Heating Rated Capacity (17° F) Btu/h 23,000 28,000
Heating Maximum Capacity (17° F) Btu/h 25,300 37,900
Heating Maximum Capacity (5° F) Btu/h 22,300 30,200
Heating Cap. Range Min - Max Btu/h 11,200~38,000 11,850~52,000
HSPF2 8.8 9.8
COP (47° F) W/W 3.01 3.1
COP (17° F) W/W 1.9 1.8
COP (5° F) W/W 2.02 1.92
68 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
38MBRC OUTDOOR UNIT
PERFORMANCE:
Light Commercial
40MBFQ Floor Console
Size 36K 48K 58K
Indoor Model 40MBFQ36---3 40MBFQ48---3 40MBFQ58---3
Cooling System Tons 3.0 4.0 4.5
Cooling Rated Capacity Btu/h 36,000 48,000 54,000
Cooling Cap. Range Min - Max Btu/h 11,400~36,000 15,800~48,000 15,000~54,000
SEER2 19.0 18.9 19.8
EER2 8.5 9.3 9.8
Heating Rated Capacity (47° F) Btu/h 38,000 50,000 60,000
Heating Rated Capacity (17° F) Btu/h 23,000 29,000 35,000
Heating Maximum Capacity (17° F) Btu/h 23,000 29,000 35,000
Heating Maximum Capacity (5° F) Btu/h 22,000 28,000 30,000
Heating Cap. Range Min - Max Btu/h 11,400~38,000 12,000~50,000 17,000~62,000
HSPF2 9.0 10.0 9.0
COP (47° F) W/W 2.8 2.5 3
COP (17° F) W/W 2.34 2.52 2.49
COP (5° F) W/W 1.8 1.95 1.9
PERFORMANCE:
40MBDQ Ducted
Size 36K 48K 58K
Indoor Model 40MBDQ36---3 40MBDQ48---3 40MBDQ58---3
Cooling System Tons 3.0 4.0 4.8
Cooling Rated Capacity Btu/h 36,000 48,000 57,000
Cooling Cap. Range Min - Max Btu/h 5,900~36,000 12,000~48,000 13,000~59,000
SEER2 15.8 15.1 17.0
EER2 8.8 8.5 10.3
Heating Rated Capacity (47° F) Btu/h 40,000 50,000 60,000
Heating Rated Capacity (17° F) Btu/h 27,000 29,000 35,400
Heating Maximum Capacity (17° F) Btu/h 25,000 29,000 35,400
Heating Maximum Capacity (5° F) Btu/h 22,000 32,000 35,000
Heating Cap. Range Min - Max Btu/h 12,700~40,000 11,600~50,000 12,000~61,000
HSPF2 8.8 9.3 8.4
COP (47° F) W/W 3.37 3 3.5
COP (17° F) W/W 2.63 2.57 2.5
COP (5° F) W/W 1.9 1.95 2.01
PERFORMANCE:
Performance™
Cassette
FEATURES Sizes: 36 / 48
• Modes: Cool, Heat, Dry, Fan, Auto, Turbo Select sizes are ENERGY STAR® certified based on
• Louver control (fixed or swing) indoor pairings
CONTROLS
Wireless Remote Controller included with indoor unit
Optional Wired Remote Controller KSACN0101AAA
(timer function)
Optional Wired Remote Controller KSACN0701AAA
(7 day programmable)
70 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
40MBCAQ CASSETTE
SPECIFICATIONS:
Light Commercial
40MBCAQ Cassette
Heat Pump
System
Size 36 48
Indoor Model 40MBCAQ36XA3 40MBCAQ48XA3
Electrical
Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 208/230-1-60
Power Supply Indoor Unit Powered From Outdoor Unit
MCA A 1.0 1.5
Controls
Wireless Remote Controller (° F /° C Convertible) Standard Standard
Wired Remote Controller (° F / ° C Convertible) Optional Optional
Operating Range
Cooling Indoor DB Min - Max ° F (° C) 60.8~90 (16~32) 60.8~90 (16~32)
Heating Indoor DB Min - Max ° F (° C) 32~86 (0~30) 32~86 (0~30)
Piping
Pipe Connection Size - Liquid in (mm) 3/8 (9.52) 3/8 (9.52)
Pipe Connection Size - Suction in (mm) 5/8 (15.9) 5/8 (15.9)
Indoor
Body Unit Width in (mm) 32.68 (830) 32.68 (830)
Body Unit Height in (mm) 9.65 (245) 11.3 (287)
Body Unit Depth in (mm) 32.68 (830) 32.68 (830)
Body Net Weight lbs (kg) 59.97 (27.2) 64.59 (29.3)
Panel Unit Width in (mm) 37.4 (950) 37.4 (950)
Panel Unit Height in (mm) 2.17 (55) 2.17 (55)
Panel Unit Depth in (mm) 37.4 (950) 37.4 (950)
Panel Net Weight lbs (kg) 11.02 (5) 11.02 (5)
Number of Fan Speeds 4 4
Airflow (lowest to highest) cfm 753/853/947/1041 935/1059/1171/1288
Sound Pressure (lowest to highest) dB(A) 46/49/51/53 49/52/54/56
Air Throw Data ft (m) 16.4 (5) 16.4 (5)
Moisture Removal Pint/h (L/h) 8.5 (4.0) 12.3 (5.8)
Field Drain Pipe Size O.D. in (mm) 1 (25.4) 1 (25.4)
Performance may vary based on the Outdoor unit matched to. See compatible Outdoor Units pages for Performance Data
COMPATIBILITY:
Indoor Unit 40MBCAQ36XA3 40MBCAQ48XA3
Outdoor Unit 38MBRCQ36AA3 38MBRCQ48AA3
40MBCAQ CASSETTE 71
PERFORMANCE™ SERIES
40MBDQ DUCTED
Light Commercial
ACCESSORIES
Wi-Fi® kit KSAIF0401AAA
24V Interface for third-party thermostat compatibility KSAIC0301230
72 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
40MBDQ DUCTED
SPECIFICATIONS:
Light Commercial
40MBDQ Ducted
Heat Pump
System
Size 36 48 58
Indoor Model 40MBDQ36---3 40MBDQ48---3 40MBDQ58---3
Electrical
Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 208/230-1-60 208/230-1-60
Power Supply Indoor Unit Powered From Outdoor Unit
MCA A 2.45 3.2 3.65
Controls
Wireless Remote Controller (° F / ° C Convertible) Standard Standard Standard
Wired Remote Controller (° F / ° C Convertible) Standard Standard Standard
Operating Range
Cooling Indoor DB Min - Max ° F (° C) 63~90 (17~32) 63~90 (17~32) 63~90 (17~32)
Heating Indoor DB Min - Max ° F (° C) 32~86 (0~30) 32~86 (0~30) 32~86 (0~30)
Piping
Pipe Connection Size - Liquid in (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Pipe Connection Size - Suction in (mm) 5/8 (16) 5/8 (16) 3/4 (19)
Indoor
Unit Width in (mm) 53.54 (1,360) 47.24 (1,200) 55.12 (1,400)
Unit Height in (mm) 9.8 (249) 11.81 (300) 17.32 (440)
Unit Depth in (mm) 30.47 (774) 34.41 (874) 33.78 (858)
Net Weight lbs (kg) 106.48 (48.3) 119.71 (54.3) 163 (74)
Number of Fan Speeds 3 3 3
Airflow (lowest to highest) cfm 700/910/1,080 720/1,030/1,230 1,260/1,710/2,150
Sound Pressure (lowest to highest) dB(A) 38.5/42/45.5 46/49.5/50.5 51/54/57
Max Static Pressure in W.C. 0.64 0.64 0.80
Field Drain Pipe Size O.D. in (mm) 1 (25.4) 1 (25.4) 1 (25.4)
Performance may vary based on the compatible outdoor units. See respective pages for performance data.
COMPATIBILITY:
Indoor Unit 40MBDQ36---3 40MBDQ48---3 40MBDQ58---3
Outdoor Unit 38MBRCQ36A--3 38MBRCQ48A--3 38MBRCQ58A--3
40MBDQ DUCTED 73
PERFORMANCE™ SERIES
40MBDAQ HIGH STATIC SLIM DUCTED
Light Commercial
ACCESSORIES
Wi-Fi® kit KSAIF0401AAA
24V Interface Kit 230V KSAIC0301230
74 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
40MBDAQ HIGH STATIC SLIM DUCTED:
SPECIFICATIONS:
Light Commercial
40MBDAQ High Static Slim Ducted
Heat Pump
System
Size 36 48 58
Indoor Model 40MBDAQ36XH3 40MBDAQ48XH3 40MBDAQ58XH3
Electrical
Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 208/230-1-60 208/230-1-60
Power Supply Indoor Unit Powered From Outdoor Unit
MCA A 3.0 4.0 5.0
Controls
Wireless Remote Controller (° F / ° C Convertible) Standard Standard Standard
Wired Remote Controller (° F / ° C Convertible) Standard Standard Standard
24V Interface for 3rd Part Thermostat Control Optional Optional Optional
Wi-Fi® Control for Phone App Control Optional Optional Optional
Operating Range
Cooling Indoor DB Min - Max ° F (° C) 62~90 (16~32) 62~90 (16~32) 62~90 (16~32)
Heating Indoor DB Min - Max ° F (° C) 59~84 (15~29) 59~84 (15~29) 59~84 (15~29)
Piping
Pipe Connection Size - Liquid in (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Pipe Connection Size - Suction in (mm) 5/8 (16) 5/8 (15.9) 7/8 (22)
Indoor
Unit Width in (mm) 47.24 (1200) 47.24 (1200) 55.12 (1400)
Unit Height in (mm) 11.81 (300) 11.81 300) 18.11 (460)
Unit Depth in (mm) 34.41 (874) 34.41 (874) 33.78 (858)
Net Weight lbs (kg) 106.48 (48.3) 119.71 (54.3) 163 (74)
Number of Fan Speeds 3 3 3
Airflow (lowest to highest) cfm 1000/1235/1588 1059/1588/1882 1262/1709/2156
Sound Pressure (lowest to highest) dB(A) 36/41/45 45/51/54 50/53/57
Max Static Pressure in W.C. 0.8 0.8 0.8
Field Drain Pipe Size O.D. in (mm) 1.0 (25.4) 1.0 (25.4) 1.0 (25.4)
Performance may vary based on the compatible outdoor units. See respective pages for performance data.
COMPATIBILITY:
Indoor Unit 40MBDAQ36XH3 40MBDAQ48XH3 40MBDAQ58XH3
Outdoor Unit 38MBRCQ36AA3 38MBRCQ48AA3 38MBRCQ58AA3
Performance™
Commercial
Console
FEATURES Sizes: 36 / 48 / 58
• Modes: Cool, Heat, Dry, Fan, Auto
KEY FEATURES
• Auto-restart function
Outside Air Intake
• Capable to be mounted on floor
Outside air is brought into the room via a connection pipe,
and ceiling
which keeps the indoor air fresher and cleaner.
• Louver control (fixed or swing)
Flexible Installation
• Three fan speeds Can be installed on the floor or ceiling depending on the
• Follow Me (senses temperature at application need.
handheld remote)
• Heating setback (46° F Heating Mode) CONTROLS
• Quiet indoor operation, as low as 43 dB(A) Wireless Remote Controller included with indoor unit
COMPATIBLE WITH:
• 38MBRC Outdoor Unit (p 66)
Optional Wireless
Wired Controller Remote
(7-Day Programmable) Controller
KSACN0701AAA
ACCESSORIES
Wi-Fi® kit KSAIF0401AAA
24V Interface for third-party thermostat compatibility KSAIC0301230
76 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
40MBFQ CONSOLE
SPECIFICATIONS:
Light Commercial
40MBFQ Console
Heat Pump
System
Size 36 48 58
Indoor Model 40MBFQ36---3 40MBFQ48---3 40MBFQ58---3
Electrical
Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 208/230-1-60 208/230-1-60
Power Supply Indoor Unit Powered From Outdoor Unit
MCA A 1.23 0.85 1.48
Controls
Wireless Remote Controller (° F / ° C Convertible) Standard Standard Standard
Wired Remote Controller (° F / ° C Convertible) Optional Optional Optional
Operating Range
Cooling Indoor DB Min - Max ° F (° C) 63~90 (17~32) 63~90 (17~32) 63~90 (17~32)
Heating Indoor DB Min - Max ° F (° C) 32~86 (0~30) 32~86 (0~30) 32~86 (0~30)
Piping
Pipe Connection Size - Liquid in (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Pipe Connection Size - Suction in (mm) 5/8 (16) 5/8 (16) 3/4 (19)
Indoor
Unit Width in (mm) 50.59 (1,285) 64.96 (1,650) 64.96 (1,650)
Unit Height in (mm) 9.25 (235) 9.25 (235) 9.25 (235)
Unit Depth in (mm) 26.57 (675) 26.57 (675) 26.57 (675)
Net Weight lbs (kg) 69 (31.3) 83.78 (38) 110 (50)
Number of Fan Speeds 3 3 3
Airflow (lowest to highest) cfm 638/917/1,037 1,000/1,120/1,350 796/1,029/1,385
Sound Pressure (lowest to highest) dB(A) 43/49/54 52/54/57 46/49/55
Air Throw Data ft (m) 33 (10) 39 (12) 39 (12)
Field Drain Pipe Size O.D. in (mm) 1 (25.4) 1 (25.4) 1 (25.4)
Performance may vary based on the compatible outdoor units. See respective pages for performance data.
COMPATIBILITY:
Indoor Unit 40MBFQ36---3 40MBFQ48---3 40MBFQ58---3
Outdoor Unit 38MBRCQ36A--3 38MBRCQ48A--3 38MBRCQ58A--3
40MBFQ CONSOLE 77
PERFORMANCE™ SERIES
40MBAB AIR HANDLER
Light Commercial
Performance™
Air Handler
FEATURES Size: 36 / 48 / 60
• Modes: Cool, Heat, Dry, Fan, Auto
KEY FEATURES
• 4-way installation (Up flow, Down flow,
Right, Left) Unmatched Maintenance Simplicity
With a top panel and an indoor coil that can be easily
• New aluminum coil
removed, get faster access to the core parts of the unit
• Automatic Airflow Technology with static needed for service. You only need to remove two screws!
pressure up to 0.8 in W.C.
Less Complex Electronics
• Less than 2% air leakage Having only two integrated printed circuit boards means
• Easy maintenance the electronic components are less complicated. One is
the main control board, and the other is the function
• Quiet indoor operation board for the 24V Interface, dip switch, wired controller
• Anti-corrosive fin coating and LED display.
Easier Access to Electric Heater
COMPATIBLE WITH: This single-piece construction enables easy installation
and maintenance.
• 38MBRC Outdoor Unit (p 66)
Modular Slide Design
The indoor coil can be easily pulled out through the slide
track for quick and easy maintenance.
CONTROLS
Wireless Remote Controller included with indoor unit
24V Interface for third party thermostat compatibility
built-in
WARRANTY
Limited Warranty*
10-year limited to original purchaser on compressor and
parts upon timely registration, otherwise 5 years.
78 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
40MBAB AIR HANDLER
SPECIFICATIONS:
Light Commercial
40MBAB Air Handler
Heat Pump
System
Size 36 48 60
Indoor Model 40MBABQ36XA3 40MBABQ48XA3 40MBABQ60XA3
Electrical
Voltage-Phase-Cycle V-Ph-Hz 208/230-1-60 208/230-1-60 208/230-1-60
Power Supply Indoor unit powered from outdoor unit
MCA A. 5 7.5 9
Controls
Wireless Remote Controller (° F/° C Convertible) Standard Standard Standard
Wired Remote Controller (° F/° C Convertible) Standard Standard Standard
Operating Range
Cooling Indoor DB Min - Max ° F (° C) 60~90 (16~32) 60~90 (16~32) 60~90 (16~32)
Heating Indoor DB Min - Max ° F (° C) 32~86 (0~30) 32~86 (0~30) 32~86 (0~30)
Piping
Pipe Connection Size - Liquid in (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Pipe Connection Size - Suction in (mm) 5/8 (16) 5/8 (16) 7/8 (22)
Indoor
Unit Width in (mm) 21 (534) 21 (534) 24.5 (622)
Unit Height in (mm) 49 (1245) 49 (1245) 53 (1346)
Unit Depth in (mm) 21 (534) 21 (534) 21 (534)
Net Weight lbs (kg) 129.63 (58.8) 132.5 (60.1) 164.02 (74.4)
Number of Fan Speeds 4 4 4
Airflow (lowest to highest) CFM 865/971/1082/1188 906/1094/1282/1471 1135/1359/1582/1806
Sound Pressure - Cooling
dB(A) 41.4/44.0/48.5 44.6/47.7/51.0/53.7 45.7/47.5/51.2/53.3
(lowest to highest)
Sound Pressure - Heating
dB(A) 33.9/39.0/45.1 43.4/47.8/50.5/53.8 39.4/44.9/50.1/51.0
(lowest to highest)
Max Static Pressure in W.C. 0.8 0.8 0.8
Field Drain Pipe Size O.D. in (mm) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1)
*Performance may vary based on the compatible outdoor units. See respective pages for performance data.
COMPATIBILITY:
An Efficient
Light Commercial
Reliable System
that’s Ideal for
Small Outdoor
Spaces
SYSTEM FEATURES Heat Pump with Basepan Heater
• Anti-corrosive fin coating Inverter-driven, variable speed, rotary compressor
• Traditional unitary line set sizes Up to 18.0 SEER2
• Quiet operation Up to 10.0 HSPF2
Sizes: 18 / 24 / 30 / 36 / 48 / 60
OUTDOOR FEATURES
• Factory installed basepan heater KEY FEATURES
• Factory installed crankcase heater Minimal Footprint
A low-profile, unobtrusive outdoor unit makes this system
• Low voltage controls an ideal option for homes with zero lot lines or limited
• 24V Interface pre-installed outdoor space.
• Standard heat and high heat options Whole-Home Solution
This versatile, energy efficient system can be easily
• Auto-restart function
retrofitted to combine with existing connections, providing
• Condenser high temp protection an efficiency upgrade for your entire home.
80 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
38MURA OUTDOOR UNIT
SPECIFICATIONS:
Light Commercial
38MURA Outdoor Unit
Heat Pump (Standard Heat)
System
Outdoor Size 1.5T 2T 2.5T 3T 4T 5T
Outdoor Model 38MURAQ18AA3 38MURAQ24AA3 38MURAQ30AA3 38MURAQ36AA3 38MURAQ48AA3 38MURAQ60AA3
Electrical
Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
MCA A. 16 19 20 24 34 34
Recommended Fuse Size A. 20 20 25 25 35 35
MOPA - Fuse Rating A. 20 30 35 40 50 60
Short Circuit Current Rating (SCCR) kA 2.4 2.4 2.4 2.4 2.4 2.4
Operating Range
Cooling Outdoor DB Min - Max ° F (° C) 5~130 (-15~55) 5~130 (-15~55) 5~130 (-15~55) 5~130 (-15~55) 5~130 (-15~55) 5~130 (-15~55)
Heating Outdoor DB Min - Max ° F (° C) -5~86 (-15~30) -5~86 (-15~30) -5~86 (-15~30) -5~86 (-15~30) -5~86 (-15~30) -5~86 (-15~30)
Piping
Total Piping Length ft (m) 98 (30) 164 (50) 164 (50) 213 (65) 213 (65) 213 (65)
Piping Lift* ft (m) 65 (20) 82 (25) 82 (25) 98 (30) 98 (30) 98 (30)
Pipe Connection Size - Liquid in (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Pipe Connection Size - Suction in (mm) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 7/8 (22)
Refrigerant
Refrigerant Type R410A R410A R410A R410A R410A R410A
Charge lbs (kg) 3.53 (1.6) 4.63 (2.1) 6.72 (3.05) 8.16 (3.7) 10.4 (4.7) 10.8 (4.9)
Add'l Refrigerant (between Std & Max Piping Lengths) Oz/ft (g/m) 0.69 (65) 0.69 (65) 0.69 (65) 0.69 (65) 0.69 (65) 0.69 (65)
Metering Device EEV EEV EEV EEV EEV EEV
Outdoor Coil
Face Area Sq. Ft. 5 5.9 8.18 8.14 13.53 13.36
No. Rows 2 2 2.6 3 2 3
Fins per inch 20 20 18 18 18 18
Circuits 4 6 6 6 8 14
Compressor
Type Rotary Inverter Rotary Inverter Rotary Inverter Rotary Inverter Rotary Inverter Rotary Inverter
Model KSN140D21UFZ KTM240D57UMT KTF250D22UMT KTF250D22UMT KTQ420D1UMU KTQ420D1UMU
Oil Type VG74 VG74 VG74 VG74 VG74 VG74
Oil Charge Fl. Oz. 14.9 22.7 22.7 22.7 47.3 47.3
Rated Current RLA 9 14 16 17.6 24 24.6
Airflow & Sound
Airflow CFM 1,450 1,765 3,000 2,235 4,500 4,412
Sound Pressure dB(A) 54 60 62 61 59 61
PERFORMANCE:
38MURA Outdoor Unit
Heat Pump (Standard Heat)
Outdoor Size 1.5T 2T 2.5T 3T 4T 5T
M1 Ratings
Cooling Rated Capacity Btu/h 18,000 24,000 30,000 36,000 47,000 57,000
Cooling Cap. Range Min - Max Btu/h 5400~18700 7500~26000 9500~33000 8900~38900 10500~48000 4400~60200
SEER2 17.0 17.0 17.3 16.9 15.8 14.7
EER2 10.9 10.5 10.6 10.1 8.8 8.8
Heating Rated Capacity (47° F) Btu/h 18,000 26,000 31,000 36,000 55,000 60,000
Heating Rated Capacity (17° F) Btu/h 11,500 20,700 20,000 20,500 36,500 36,000
Heating Rated Capacity (5° F) Btu/h 10,000 17,000 17,800 21,000 36,500 34,800
Heating Cap. Range Min - Max Btu/h 5600~18700 5600~30000 12200~32000 6000~36400 11700~57000 11400~63100
HSPF2 8.8 9.2 8.5 8.2 9.4 8.5
COP (47° F) W/W 3.50 3.45 3.25 3.39 3.15 3.45
COP (17° F) W/W 2.75 2.40 2.45 2.40 2.30 2.35
COP (5° F) W/W 1.90 2.00 1.75 1.88 1.98 1.89
PERFORMANCE:
38MURA Outdoor Unit
Heat Pump (High Heat)
Outdoor Size 1.5T - HH 2T - HH 2.5T - HH 3T - HH 4T - HH 5T - HH
M1 Ratings
Cooling Rated Capacity Btu/h 18,000 24,000 30,000 36,000 47,000 55,000
Cooling Cap. Range Min - Max Btu/h 6900~21000 6400~27000 10400~33600 12000~47400 18000~48000 18000-56000
SEER2 18.0 17.4 16.2 16.0 15.6 15.3
EER2 12.4 11.7 10.0 10.0 8.2 8.8
Heating Rated Capacity (47° F) Btu/h 19,000 24,000 33,000 40,000 50,000 59,000
Heating Rated Capacity (17° F) Btu/h 13,000 18,600 20,400 29,500 35,000 42,000
Heating Rated Capacity (5° F) Btu/h 16,500 22,700 24,100 34,500 46,000 50,000
Heating Cap. Range Min - Max Btu/h 2800~21000 10100~31000 12000~37000 9000~57200 20000~55000 20000-68000
HSPF2 9.3 10.0 8.9 9.5 9.4 9.4
COP (47° F) W/W 3.60 3.40 3.30 3.35 3.15 3.00
COP (17° F) W/W 2.50 2.40 2.30 2.40 2.30 2.60
COP (5° F) W/W 2.00 1.85 1.80 1.95 1.90 1.96
82 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
40MUAA AIR HANDLER
SPECIFICATIONS:
Light Commercial
40MUAA Air Handler
System
Indoor Size 18K 24K 30K 36K 48K 60K
Indoor Model 40MUAAQ18XA3 40MUAAQ24XA3 40MUAAQ30XA3 40MUAAQ36XA3 40MUAAQ48XA3 40MUAAQ60XA3
Electrical
Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
MCA A. 2.5 4 4.5 5 7.5 9
Recommended Fuse Size A. 5 5 5 10 10 10
MOPA - Fuse Rating A. 15 15 15 15 15 15
Operating Range
Cooling Indoor DB Min - Max ° F (° C) 60~90 (16~32) 60~90 (16~32) 60~90 (16~32) 60~90 (16~32) 60~90 (16~32) 60~90 (16~32)
Heating Indoor DB Min - Max ° F (° C) 32~86(0~30) 32~86(0~30) 32~86(0~30) 32~86(0~30) 32~86(0~30) 32~86(0~30)
Piping
Pipe Connection Size - Liquid in (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Pipe Connection Size - Suction in (mm) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 7/8 (22)
Refrigerant
Refrigerant Type R410A R410A R410A R410A R410A R410A
Metering Device EEV EEV EEV EEV EEV EEV
Indoor Coil
Face Area Sq. Ft. 3 3 3.8 3.8 3.8 4.88
No. Rows 3 3 4 4 4 5
Fins Per Inch 20 20 20 20 20 20
Circuits 6 6 10 10 10 14
Airflow & Sound
Number of Fan Speeds (low/med/high/turbo) 4 4 4 4 4 4
Airflow (lowest to highest) CFM 488/529/576/618 629/694/759/824 712/806/894/1088 865/971/1082/1188 906/1094/1282/1471 1135/1359/1582/1806
Cooling Sound Pressure
dB(A) 30.5/31.4/33.4/35.2 33.6/36.6/38.7/40.4 37.7/41.3/43.0/45.6 40.2/43.2/45.7/48.0 42.5/47.1/50.3/54.0 45.0/49.1/52.1/55.3
(low to high)
Heating Sound Pressure
dB(A) 29.8/30.7/34.0/35.3 32.4/36.9/39.6/40.6 29.5/36.9/43.0/43.2 35.6/40.7/46.8/46.7 43.7/46.8/50.2/52.7 43.4/48.0/53.0/60.5
(low to high)
Max Static Pressure in W.C. 0.8 0.8 0.8 0.8 0.8 0.8
Field Drain Pipe Size O.D. in (mm) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1)
Performance™
Outdoor Unit
FEATURES Cooling Only – 35SCA5
• Available in 208/230V–1, Fixed-Speed Compressor
208/230V–3 and 460V–3 Up to 17.1 SEER2
• WeatherArmorTM cabinet – All-steel cabinet Sizes: 18 / 24 / 30 / 36 / 48 / 60
construction – Mesh coil guard
• Quiet outdoor operation, as low as 66 dB(A)
KEY FEATURES
• Piping length up to 250 ft.
Longer Piping Lengths
• Cooling operating range-20° ~ 125° F Piping flexibility up to a total piping length
(-28° ~ 52° C) (w/ Low-Ambient Kit) of 213 ft. (65m.).
Low Ambient Cooling
COMPATIBLE WITH: With built-in low ambient kit or special designed PCB,
• Ducted Indoor Units outdoor fan speeds can be changed automatically based on
the temperature. The unit can run cooling operation even in
low ambient temperatures.
84 PERFORMANCE™ SERIES
PERFORMANCE™ SERIES
35SCA5
PHYSICAL DATA:
Light Commercial
35SCA5
Unit Size 18 24 30 36 48 60
Compressor Type Scroll
Refrigerant Puron® (R-410A)
Charge lbs (kg) 7.50 (3.40) 6.80 (3.08) 8.70 (3.95) 9.40 (4.26) 10.50 (4.76) 10.50 (4.76)
Cond Fan Propeller Type, Direct Drive
Air Discharge Horizontal
Air Qty CFM 1360 1530 1920 2615 2785 2785
Motor HP 1/3 1/3 1/10 1/4 1/4 1/3
Motor RPM in (mm) 830 830 800 825 850 840
Cond Coil
Face Area Sq. ft. 7.5 7.5 12.3 12.3 14.4 14.4
Fins per In. 20 20 20 20 20 20
Rows 2 2 2 2 2 2
Circuits 2 3 3 3 4 4
Valve Connect In. ID
Vapor 5/8 3/4 3/4 7/8 7/8 7/8
Liquid 3/8
Refrigerant Tubes* In. OD
Rated Vapor* 5/8 3/4 3/4 7/8 7/8 1-1/8
Max Liquid Line† 3/8
* Units are rated with 25ft.(7.6m) of lineset length. Review the Vapor Line Sizing and Cooling Capacity Loss section when using other lineset sizes and lengths of lineset.
†
Liquid Line Sizing For Cooling Only Systems with Puron® (R-410A) Refrigerant Tables.
Note: Review the unit’s Installation Instructions for proper installation guidance.
35SCA5 85
TOSHIBA CARRIER
RAVAT2 OUTDOOR UNIT
Light Commercial
Toshiba Carrier
Light Commercial
Heat Pump
FEATURES Inverter Compressor
• Available in 208/230V Up to 25.5 SEER2
• Quiet outdoor operation, as low as 48 dB(A) Up to 11.3 HSPF2
• Piping length 165 ~ 245 ft. Sizes: 12 / 18 / 24 / 30 / 36 / 42 / 48
• Cooling operating range 5° ~ 115° F
• Heating operating range -13° ~ 59° F
(-20° ~ 15° C)
Systems can be programmed to operate in cooling-only mode with
heating locked out.
Ducted Console
Systems can be programmed to operate in cooling-only mode with heating locked out.
Light Commercial
RAV System: Outdoor Model
Model name Outdoor unit RAV - SP122AT2P-UL SP182AT2P-UL SP242AT2P-UL SP302AT2P-UL SP362AT2P-UL SP422AT2P-UL SP482AT2P-UL
Outdoor unit
Air flow volume Cooling / Heating CFM 1590 / 1590 1590 / 1590 2300 / 2220 3570 / 2870 3570 / 3100 3570 / 3290 4540 / 4060
Sound pressure level (High) (*2) Cooling / Heating dB(A) 48 / 52 48 / 52 52 / 54 54 / 54 54 / 54 54 / 54 60 / 60
Height in 21.7 35 52.8
External dimension Width in 30.8 35.3 35.4
Depth in 11.4 12.6 12.6
Total weight Main unit lbs 99.2 141.1 218.3 233.7
Refrigerant
Min. length ft 16-1/2
Max. total length ft 164 246
Refrigerant pipe
Lift (ODU below IDU) ft 98
Lift (ODU above IDU) ft 98
Refrigerant (*3) (Charged refrigerant amount) lbs 3.75 3.75 5.51 6.83 6.83 7.27 7.27
Flare connections
Gas side in 1/2 5/8
Liquid side in 1/4 3/8
Operating range
Cooling °F DB 5 to 115
Cooling w/ wind baffles °F DB 5 to 115 -13 to 115
Heating °F WB -13 to 59
Note:
(*1) Rated conditions
Cooling: Indoor air temperature 80°F dry bulb / 67°F wet bulb, Outdoor air temperature 95°F dry bulb
Heating: Indoor air temperature 70°F dry bulb, Outdoor air temperature 47°F dry bulb / 43°F wet bulb
(*2) The actual values in an operating environment are generally higher than the indicated values due to the contribution from ambient noise.
(*3) The amount does not consider extra piping length. Refrigerant must be added on site in accordance with the actual piping length.
(*4) Select wire size based on larger value of MCA
MCA: Minimum Circuit Amps (Minimum Circuit Amps required for power supply design)
(*5) MOCP: Maximum Over Current Protection
COMPATIBILITY:
4-Way Cassette Underceiling Medium Static Ducted High Wall
RAV-SPxxxUT-UL RAV-SPxxxCT-UL RAV-SPxxxBTP-UL RAV-SPxxxKRT-UL
Single-split SDI
• •
RAV-SP120AT2P-UL
Single-split SDI
• • • •
RAV-SP180/240/300/360AT2-UL
Single-split SDI
• • •
RAV-SP420/480AT2-UL
Toshiba Carrier
RAV High Wall
FEATURES Sizes: 12 / 18 / 24 / 30 / 36
• Available in 208/230V
• Modes: Cool, Heat, Dry, Fan, Auto CONTROLS
• Turbo Mode Wireless Remote Controller included with indoor unit
• Sleep Mode
• Filter maintenance indicator
• Quiet indoor operation, as low as 28 dB(A)
COMPATIBLE WITH:
• R AVAT2 Outdoor Unit
Single Zone (p 86) Optional Standard
Wired Controller Wireless
(7-Day Programmable) Controller
RBC-AWSU52-UL
ACCESSORIES
Condensate Pump (230V optional)
Insulated 25' Line Set
Systems can be programmed to operate in cooling-only mode with heating locked out.
Light Commercial
RAV System: High Wall
Model name Indoor unit RAV - SM122KRTP-UL SM182KRTP-UL SM242KRTP-UL SM302KRTP-UL SM362KRTP-UL
Operating Range
Capacity kBtu/h 12 18 24 30 36
Cooling SEER2 25.2 23.8 22.7 23.6 22
EER2 15.7 12 11.8 13.1 10.5
Capacity kBtu/h 14 20 27 34 40
Heating HSPF2 11.1 10.3 10.3 9.5 8.9
COP 13.0 11.4 10.6 12.0 10.7
Electrical
Power supply 1 Phase 208V/230V 60 Hz
Electrical requirements MCA(*4) 14 14 17 30 30
MOCP(*5) 25 25 25 40 40
Indoor unit
Height in 12.6 13.7
External dimension Width in 41.4 47.2
Depth in 9.9 11
Total weight 33.1 44.1
Standard airflow (H/M/L) CFM 475 / 355 / 250 530 / 425 / 325 705 / 530 / 355 940 / 825 / 705 970 / 910 / 735
Main unit Motor output W 30 30 30 61 61
Motor type DC DC DC DC DC
Gas side in 1/2 5/8
Connecting pipe Liquide side in 1/4 3/8
Drain port (nominal dia) in VP16 (Polyvinyl Chloride Tube: Dia. 0.87 Internal Dia. 0.63)
Sound pressure level (H/M/L)(*2) dB(A) 37 / 33 / 28 41 / 37 / 32 46 / 41 / 35 48 / 45 / 41 50 / 47 / 43
Note:
(*1) Rated conditions
Cooling: Indoor air temperature 80°F dry bulb / 67°F wet bulb, Outdoor air temperature 95°F dry bulb
Heating: Indoor air temperature 70°F dry bulb, Outdoor air temperature 47°F dry bulb / 43°F wet bulb
(*2) The actual values in an operating environment are generally higher than the indicated values due to the contribution from ambient noise.
(*3) The amount does not consider extra piping length. Refrigerant must be added on site in accordance with the actual piping length.
(*4) Select wire size based on larger value of MCA
MCA: Minimum Circuit Amps (Minimum Circuit Amps required for power supply design)
(*5) MOCP: Maximum Over Current Protection
Toshiba Carrier
Cassette
FEATURES Sizes: 18 / 24 / 30 / 36 / 42 / 48
• Available in 208/230V
• Modes: Cool, Heat, Dry, Fan, Auto CONTROLS
• One-touch memory Controller not included with indoor unit. Must order:
Optional Wireless Remote Controller
• Sleep Mode Optional Wired Remote Controller
• Filter maintenance indicator
• Built-in condensate lift pump
• Outside air intake
• Branch duct capability
• Independent louver control (fixed or swing)
• Power-saving Mode
• Quiet indoor operation, as low as 32 dB(A) Optional Standard
Wired Controller Wireless
(7-Day Programmable) Controller
COMPATIBLE WITH: RBC-AWSU52-UL
• R AVAT2 Outdoor Unit
Single Zone (p 86) ACCESSORIES
Condensate Pump (230V optional)
Insulated 25' Line Set
Outside air intake
Air-discharge direction kit
Auxiliary Fresh Air Flange
Air discharge direction kit
TCB-FF101URUL
TCB-BC1602UUL
Systems can be programmed to operate in cooling-only mode with heating locked out.
Light Commercial
RAV System: 4-Way Cassette
Model name Indoor unit RAV - SM182UTP-UL SM242UTP-UL SM302UTP-UL SM362UTP-UL SM422UTP-UL SM482UTP-UL
Operating Range
Capacity(*1) kBtu/h 18 24 30 36 42 48
Cooling SEER2 25.5 23.7 23.7 24.3 22.6 22.4
EER2 13.5 13 14 13.4 12 10.6
Capacity(*1) kBtu/h 20 27 34 40 47 54
Heating HSPF2 11.3 10.7 11.2 11.1 10.2 9.8
COP 13.90 13.2 13.8 13.3 12.0 11.0
Electrical
Power supply 1 Phase 208V/230V 60 Hz
Electrical requirements MCA(*4) A 14 17 30 30 32 32
MOCP(*5) A 25 25 40 40 40 40
Indoor unit
Height in 10.1 (1.2) 12.6 (1.2)
External dimension
Width in 33.1 (37.4) 33.1 (37.4)
Main unit (Ceiling panel)*
Depth in 33.1 (37.4) 33.1 (37.4)
Total weight (Ceiling panel)* lbs 56.3 (10) 65.1 (10)
Standard airflow (H/M/L) CFM 670 / 540 / 470 730 / 630 / 510 1150 / 840 / 630 1200 / 850 / 650 1250 / 870 / 650 1300 / 1080 / 880
Main unit Motor output W 60 60 130 130 130 130
Motor type DC DC DC DC DC DC
Gas side in 1/2 5/8
Connecting pipe Liquid side in 1/4 3/8
Drain port (nominal dia) in VP25 (Polyvinyl Chloride Tube: External Dia. 1-1/4 Internal Dia. 1)
Sound pressure level (H/M/L)(*2) dB(A) 38 / 33 / 31 41 / 37 / 34 43 / 38 / 34 45 / 39 / 35 46 / 40 / 36 48 / 44 / 41
Note:
(*1) Rated conditions
Cooling: Indoor air temperature 80°F dry bulb / 67°F wet bulb, Outdoor air temperature 95°F dry bulb
Heating: Indoor air temperature 70°F dry bulb, Outdoor air temperature 47°F dry bulb / 43°F wet bulb
(*2) The actual values in an operating environment are generally higher than the indicated values due to the contribution from ambient noise.
(*3) The amount does not consider extra piping length. Refrigerant must be added on site in accordance with the actual piping length.
(*4) Select wire size based on larger value of MCA
MCA: Minimum Circuit Amps (Minimum Circuit Amps required for power supply design)
(*5) MOCP: Maximum Over Current Protection
RAVUT2 CASSETTE 91
TOSHIBA CARRIER
RAVBT2 DUCTED STYLE
Light Commercial
Toshiba Carrier
Ducted
FEATURES Sizes: 12 / 18 / 24 / 30 / 36 / 42 / 48
• Available in 208/230V
• Modes: Cool, Heat, Dry, Fan, Auto CONTROLS
• Up to 0.46 in W.C. Controller not included with indoor unit. Must order:
Optional Wireless Remote Controller
• Rear or bottom return Optional Wired Remote Controller
• Outside air intake
• Built-in condensate lift pump
• Quiet indoor operation, as low as 25 dB(A)
COMPATIBLE WITH:
• R AVAT2 Outdoor Unit
Single Zone (p 86)
Optional Optional
Wired Controller Wireless
(7-Day Programmable) Controller
RBC-AWSU52-UL
ACCESSORIES
Condensate Pump (208–230V optional)
Systems can be programmed to operate in cooling-only mode with heating locked out.
Light Commercial
RAV System: Medium Static Ducted
Model name Indoor unit RAV - SM122BTP-UL SM182BTP-UL SM242BTP-UL SM302BTP-UL SM362BTP-UL SM422BTP-UL SM482BTP-UL
Operating Range
Capacity(*1) kBtu/h 12 18 24 30 36 42 48
Cooling SEER2 17.1 14.5 19.4 19.3 17.6 16.9 16.2
EER2 12.2 9.8 12.4 12.5 11 9.5 8.5
Capacity(*1) kBtu/h 14 20 27 34 40 47 54
Heating HSPF2 8.9 8.7 10.3 10.3 9.9 9 7.9
COP 13.3 11.4 13.4 14.1 13.1 12.2 11.3
Electrical
Power supply 1 Phase 208V/230V 60 Hz
Electrical
MCA(*4) A 14 14 17 30 30 32 32
requirements
MOCP(*5) A 25 25 25 40 40 40 40
Indoor unit
Height in 10.9 10.9 10.9
External dimension Width in 27.6 39.4 55.2
Depth in 29.6 29.6 29.6
Total weight lbs 52.9 70.5 92.6
Standard
CFM 395 / 330 / 265 540 / 390 / 315 775 / 640 / 510 990 / 780 / 650 1130 / 920 / 790 1130 / 955 / 810 1175 / 1025 / 885
airflow (H/M/L)
Main unit
Motor output W 150 150 150 250 250 250 250
Motor type DC DC DC DC DC DC DC
Gas side in 1/2 5/8
Liquid side in 1/4 3/8
Connecting pipe
Drain port
in VP25 (Polyvinyl Chloride Tube: External Dia. 1-1/4 Internal Dia. 1)
(nominal dia)
Sound pressure level (H/M/L)(*2) dB(A) 33 / 29 / 25 34 / 30 / 26 36 / 31 / 27 37 / 34 / 31 38 / 35 / 32 38 / 35 / 32 40 / 36 / 33
Note:
(*1) Rated conditions
Cooling: Indoor air temperature 80°F dry bulb / 67°F wet bulb, Outdoor air temperature 95°F dry bulb
Heating: Indoor air temperature 70°F dry bulb, Outdoor air temperature 47°F dry bulb / 43°F wet bulb
(*2) The actual values in an operating environment are generally higher than the indicated values due to the contribution from ambient noise.
(*3) The amount does not consider extra piping length. Refrigerant must be added on site in accordance with the actual piping length.
(*4) Select wire size based on larger value of MCA
MCA: Minimum Circuit Amps (Minimum Circuit Amps required for power supply design)
(*5) MOCP: Maximum Over Current Protection
Toshiba Carrier
Underceiling
FEATURES Sizes: 18 / 24 / 30 / 36 / 42 / 48
• Available in 208/230V
• Modes: Cool, Heat, Dry, Fan, Auto CONTROLS
• Outside air intake Controller not included with indoor unit. Must order:
Optional Wireless Remote Controller
• Power-saving Mode Optional Wired Remote Controller
• Filter maintenance indicator
• Quiet indoor operation, as low as 32 dB(A)
COMPATIBLE WITH:
• R AVAT2 Outdoor Unit
Single Zone (p 86)
Optional Optional
Wired Controller Wireless
(7-Day Programmable) Controller
RBC-AWSU52-UL
ACCESSORIES
Condensate Pump (208–230V optional)
Elbow Piping Kit
Systems can be programmed to operate in cooling-only mode with heating locked out
Light Commercial
RAV System: Underceiling
Model name Indoor unit RAV - SM182CTP-UL SM242CTP-UL SM302CTP-UL SM362CTP-UL SM422CTP-UL SM482CTP-UL
Operating Range
Capacity kBtu/h 18 24 30 36 42 48
Cooling SEER2 23.6 23.2 22 22.4 19.6 19.4
EER2 11.5 12.7 13 12.1 9.9 9.2
Capacity kBtu/h 20 27 34 40 47 54
Heating HSPF2 10.7 10.4 10.4 11.1 10.7 10.3
COP 13.1 12.9 12.2 12.5 11.5 11.1
Electrical
Power supply 1 Phase 208V/230V 60 Hz
Electrical requirements MCA(*4) A 14 17 30 30 32 32
MOCP(*5) A 25 25 40 40 40 40
Indoor unit
Height in 9.3 9.3 9.3
External dimension Width in 37.5 50 62.5
Depth in 27.2 27.2 27.2
Total weight 52.9 66.1 83.8
Standard airflow (H/M/L) CFM 565/ 425 / 320 845 / 600 / 440 845 / 600 / 440 1095 / 795 / 600 1095 / 900 / 705 1250 / 1125 / 925
Main unit Motor output W 94 94 94 139 139 139
Motor type DC DC DC DC DC DC
Gas side in 1/2 5/8
Connecting pipe Liquid side in 1/4 3/8
Drain port (nominal dia) in VP20 (Polyvinyl Chloride Tube: Dia. 1.1 Internal Dia 0.79)
Sound pressure level (H/M/L)(*2) dB(A) 37 / 35 / 28 41 / 36 / 29 43 / 36 / 33 44 / 38 / 32 44 / 41 / 35 47 / 45 / 41
Note:
(*1) Rated conditions
Cooling: Indoor air temperature 80°F dry bulb / 67°F wet bulb, Outdoor air temperature 95°F dry bulb
Heating: Indoor air temperature 70°F dry bulb, Outdoor air temperature 47°F dry bulb / 43°F wet bulb
(*2) The actual values in an operating environment are generally higher than the indicated values due to the contribution from ambient noise.
(*3) The amount does not consider extra piping length. Refrigerant must be added on site in accordance with the actual piping length.
(*4) Select wire size based on larger value of MCA
MCA: Minimum Circuit Amps (Minimum Circuit Amps required for power supply design)
(*5) MOCP: Maximum Over Current Protection
RAVCT2 UNDERCEILING 95
24V INTERFACE
Light Commercial
24V Interface
for Third-Party
Thermostat
FEATURES KSAIC0301230 Ductless Indoor + Outdoor Single Zone 208–230V
• Control the ductless system using a
third-party thermostat(*1) KEY FEATURES:
• One 24V Interface Kit per indoor head(*2) Maintain Inverter Compressor Technology
The new 24V Interface keeps the inverter compressor
• Single and multi-zone applications
operating as a variable-speed system when using a
• Keeps the inverter compressor operating third-party thermostat, making adjustments to maintain
as a variable-speed system(*3) more consistent operation.
• Rated for outdoor and indoor mounting Easy & Flexible Installation
• Dry mode contact for active Experience quick and easy installation between
dehumidification control either a single or multi-zone outdoor unit and the
fan coil. The interface can be installed either
• Remote on/off contact indoors or outdoors.
• Auxiliary heat control through Consumer Choice & Control
the thermostat(*4) Consumers can choose the type of thermostat
• Diagnostic code display LEDs they want to use without adversely affecting the
efficiency or performance of their ductless systems.
• Power supplied through the outdoor unit
COMPATIBLE WITH:
• 40MPHB High Wall (p 22)
ACCESSORIES:
• 40MAHB High Wall (p 28)
115V Transformer RCD#11203103000393
• 40MCCAQ One-Way Cassette (p 30) (Used only on ductless systems with 115V power.)
• 40MBCQ Cassette (p 32)
• 40MBCAQ Cassette (p 34)
• 40MHHAC & 40MHHAQ
High Wall (p 48)
• 40MBDQ Ducted (p 72)
• 40MBDAQ High Static
Slim Ducted (p 74)
• 40MBFQ Console (p 76)
Included in:
• 40MBAB Air Handler (p 78)
• 40MUAA Air Handler &
38MURA Outdoor Unit (p 80)
96
24V INTERFACE
COMPATIBILTY:
Light Commercial
Compatibility Table
Indoor Single Zone Outdoor Multi-Zone Outdoor
Type of Indoor Unit 208/230V
Family Name Family Name Family Name
40MPHB 38MPRB 38MGR All Sizes
High Wall 40MAHB 38MARB 38MGR All Sizes
40MHHA 38MHR 38MGR All Sizes
40MCCAQ 38MARB 38MGR All Sizes
Cassette 40MBCQ 38MARB 38MGR All Sizes
40MBCAQ 38MARB 38MGR All Sizes
40MBDQ 38MARB 38MGR All Sizes Except Size 58 (See Note)
Ducted
40MBDAQ 38MARB 38MGH All Sizes Except Size 58 (See Note)
Console 40MBFQ 38MARB 38MGR All Sizes Except Sizes 12 and 58 (See Note)
Note: The indoor unit requires an updated control board for compatibility with the 24V Interface Kit. High Wall units starting with
Serial #4316V10001 are shipped with the compatible control board. Ducted units starting with Serial #4616V10001 are shipped
with the compatible control board. For other model numbers not shown on the table above, please contact your ductless representative.
Ducted size 58 Console sizes 12 and 58 starting with serial #1419V1001 are shipped with compatible control board.
Single Zone Multi-Zone
Notes:
(*1) Third-party thermostats used with the 24V Interface Kit will replace the wireless Remote Controller included with the unit.
Consult with dealer for more information.
(*2) When using in a Multi-Zone System not all the indoor heads require a 24V Interface Kit.
(*3) A conventional 5-wire thermostat is required.
(*4) A secondary output is necessary for auxiliary heat control.
24V INTERFACE 97
C O M PAT I B I L I T Y C O N T R O L S :
• Optional
• Standard
Notes:
‡ Compatible with indoor units starting with Serial Number 0117V10001.
** Starting with Serial Number 2820V10001 (Week 28, Year 2020) the KSACN0701AAA became the standard controller but is backwards compatible with previous production units.
« 24V Interface compatible with all the sizes except sizes 12 and 58 depending on serial number. Starting with Serial Number 1419V10001 the sizes 12 and 58 are
shipped with the compatible control board. Units built prior these serial number would require a Control Board Replacement on the Indoor unit in order to be compatible.
¬ Indoor unit model comes with everything to be compatible with the USB WiFi Dongle Model 17310900000281 from the KSAIF0301AAA kit. If installed in a high wall unit
other than the 40MAQ, install the USB Wi-Fi® Dongle 17310900000281 into the high wall unit's factory USB port only and discard all other components of the KSAIF0301AAA kit.
W I - F I ® C O M PAT I B I L I T Y :
The use of the Wi-Fi® Accessory Kits on some indoor units would disable the ability
to use the Wired Controllers in some instances:
Note:
The use of the 24V interface will disable system’s Wi-Fi® module. Please consider using a Wi-Fi® Thermostat when using the 24V interface.
Wi-Fi® kits cannot be used on networks requiring a user login.
Wi-Fi® kits are only supported with networks using WPA-PSK/WPA2-PSK encryption and no encryption. WPA-PSK/WPA2-PSK encryption is recommended.
Please consult the installation instructions and Owners Manuals of the individual kits for more information.
98
S TA N D A R D F E AT U R E S G L O S S A R Y
Airflow Panel
360° air outlet creates a soft and gentle airflow, which circulates High Heating Operation
throughout the whole space and provides an even temperature The high tier and mid-tier systems can be a primary heat source, with high
distribution in the room. heating down to -22° F, so when it’s cold outside, it’s warm inside.
99
carrierductless.com
01-DLS-021-CA-01
10/2023