0% found this document useful (0 votes)
17 views5 pages

FL12323 - R9 - II - (H) Inst 12323.31

This document provides product approval details for extruded vinyl sliding patio doors, specifically models 9403, 9409, and 9422, which comply with the Florida Building Code. It outlines installation requirements, structural compliance, and necessary protective measures for wind-borne debris. The approval is valid only for the state of Florida and includes detailed specifications and materials used in the construction of the doors.

Uploaded by

admin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views5 pages

FL12323 - R9 - II - (H) Inst 12323.31

This document provides product approval details for extruded vinyl sliding patio doors, specifically models 9403, 9409, and 9422, which comply with the Florida Building Code. It outlines installation requirements, structural compliance, and necessary protective measures for wind-borne debris. The approval is valid only for the state of Florida and includes detailed specifications and materials used in the construction of the doors.

Uploaded by

admin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Digitally signed by Lyndon F Schmidt

Date: 2023.07.31 15:55:29 -04'00'


3773 STATE ROAD This item has been digitally signed and sealed by
L. F. Schmidt, P.E. on the date adjacent to the seal.
CUYAHOGA FALLS, OH 44223 Printed copies of this document are not
considered signed and sealed and the signature
must be verified on any electronic copies.
THIS PRODUCT APPROVAL IS VALID
ONLY FOR THE STATE OF FLORIDA

SERIES 9400
MODEL 9403/9409/9422
EXTRUDED VINYL SEE CHART FOR MAX. FRAME WIDTH

SLIDING PATIO DOORS


"NON-IMPACT"

SEE CHART FOR MAX. FRAME HEIGHT


GENERAL NOTES

1. This product has been evaluated and is in compliance with the 8th Edition (2023) Florida
Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone"
O X O
(HVHZ).

2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to
Z:\2023 FBC Drawings\Associated Materials, Inc\FL-12323 R9\FL-12323.30-32.dwg

base material shall be beyond wall dressing or stucco.

3. When used in areas requiring wind borne debris protection this product is required to be
protected with an impact resistant covering that complies with FBC Sections 1609.1.2 &
R301.2.1.2.

4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for
2x buck masonry construction.

© 2012 R.W. Building Consultants Inc.


5. Site conditions that deviate from the details of this drawing require further engineering
analysis by a licensed engineer or registered architect.
OVERALL MAX. MAX. DESIGN PRESSURE (PSF)
TABLE OF CONTENTS FRAME PANEL D.L.O.
GLASS
SHEET# DESCRIPTION TYPE
DIMENSION DIMENSION DIMENSION POSITIVE NEGATIVE
1 Typical elevation, design pressures & general notes
2 Horizontal cross sections 140.87" x 95.5" 47.37" X 92.37" 40.75" X 80.0" G1 +25.0 -25.0
3 Vertical cross sections and glazing details
4 Buck & frame anchoring
Bill of materials, glazing details & components
140.87" x 79.5" 47.37" X 76.19" 40.75" X 64.06" G2 +35.0 -35.0
5
NOTES:
1. Frame corners fastened with (3) #8 x 3" PH SMS and
contain a closed cell foam gasket. The frame
intersections at the sill sealed with silicone sealant.

2. Fixed panel secured to the head and sill with two molded
composite L-Brackets, one at each end of the meeting stile. 1
Bracket attached to the frame with one #8 x 1-1/4" SMS and 3
to the meeting stile with one #8 x 5/8" SMS. 2
3

1 O X 2
O 2
2

3
3
E
1-1/4" MIN.
F B EMB. (TYP.)
23 A
1-1/4" MIN. 1 C
45 10
EMB. (TYP.) 6
46 19 25
50 24
Z:\2023 FBC Drawings\Associated Materials, Inc\FL-12323 R9\FL-12323.30-32.dwg

56
18
48
9

G1 G2

© 2012 R.W. Building Consultants Inc.


50 46 G1 G2
16 10 18 38
1 J
47
D C 1 2 HORIZONTAL CROSS SECTION
HORIZONTAL CROSS SECTION
E 2 2X Buck 2 Shown w/1X sub-buck
EMB. (TYP.)
1-1/4" MIN.
E

NOTE: Sheet Metal Screws must penetrate


D
a min. of 3 threads through at least two
E K F

EMB. (TYP.)
1-1/4" MIN.
(2) sheets of metal. Maintain a minimum
5/8" edge distance. B
D
C C
1
1 36
15
15 X
C 37 20

8
1
8 8 8

16
16
8 G1 G2
G1 G2
1 VERTICAL CROSS SECTION 8
3 Shown w/ Direct to Masonry option

16
G1 G2
Z:\2023 FBC Drawings\Associated Materials, Inc\FL-12323 R9\FL-12323.30-32.dwg

11 11
2 VERTICAL CROSS SECTION
3 Shown w/ Steel Stud framing option
26

21
5/8" 13

© 2012 R.W. Building Consultants Inc.


5/8"
GLASS BITE 1" THICK GLASS BITE 1" THICK
GLASS 14
DOUBLE SIDED GLASS 15
DOUBLE SIDED
GLAZING TAPE GLAZING TAPE
5/32" TEMPERED
1/8" TEMPERED
27 4

AIR SPACE
AIR SPACE
5/32" TEMPERED
1/8" TEMPERED
INTERCEPT SPACER (STEEL) INTERCEPT SPACER (STEEL) E
GLAZING DETAIL
G1 GLAZING DETAIL
G2 3 VERTICAL CROSS SECTION
3 Shown w/ Direct to Masonry @ Sill
CL
4" (TYP.)
CL

4" (TYP.) 22" MAX. O.C.


4" (TYP.) 6" (TYP.)
(TYP.)

4" (TYP.)

6" (TYP.)
D F

O.C. (TYP.)
24" MAX.
HEAD & 2X BUCK HEAD &
JAMBS (TYP.) JAMBS (TYP.)

2X BUCK

MEETING STILE
SHOWN FOR
MASONRY MASONRY REF. ONLY

14" MAX. O.C.


OPENING OPENING

(TYP.)
(TYP.)
4"
(TYP.)
FRAME ANCHORING

6" (TYP.)
BUCK ANCHORING

6"
Masonry 2X

(TYP.)
4"
CL

CL PANEL
6" (TYP.)
4" (TYP.)
Z:\2023 FBC Drawings\Associated Materials, Inc\FL-12323 R9\FL-12323.30-32.dwg

6" (TYP.)

O.C. (TYP.)
J 1X BUCK

20" MAX.
1X BUCK
K STEEL
DIRECT TO
CONCRETE ANCHOR NOTES: D
MASONRY
1. Concrete anchor locations at the corners may be adjusted to maintain the min.
HEAD & JAMBS
edge distance to mortar joints.

© 2012 R.W. Building Consultants Inc.


2. Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted to (TYP.)
maintain the min. edge distance to mortar joints, additional concrete anchors
may be required to ensure the "MAX. ON CENTER" dimension are not exceeded. MASONRY
3. Concrete anchor table: MEETING STILE
OPENING
SHOWN FOR

4"
MIN. MIN. CLEARANCE MIN. CLEARANCE REF. ONLY
ANCHOR ANCHOR
TO MASONRY TO ADJACENT
TYPE SIZE EMBEDMENT
EDGE ANCHOR
ITW
® 1/4" 1-1/4" 2" 4"
TAPCON

4"
DeWALT
® 1/4" 1-1/4" 1" 4"
ULTRACON+

(TYP.)
FRAME ANCHORING

6"
WOOD SCREW INSTALLATION NOTES:
1. Maintain a minimum 5/8" edge distance, 1" end distance, & 1" o.c. spacing of (1X, Steel Stud, and Masonry)
wood screws to prevent the splitting of wood.
5.69" 3.25"
BILL OF MATERIALS
ITEM # DESCRIPTION MATERIAL 2.35"
A 1X BUCK (SG >= 0.42) WOOD
0.075"
B 2X BUCK (SG >= 0.42) WOOD

2.18"
0.071"

1.62"
C 1/4" MAX. SHIM SPACE -
D 1/4" X 2-3/4" PFH DeWALT OR ITW CONCRETE SCREW STEEL
MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI
E CONCRETE
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90

0.075"
STILE
10
F #10 X 2-3/4" PPH SMS (1-1/2" MIN. EMBEDMENT) STEEL
FRAME 5.69"
J 1/4" X 3-1/4" PFH DeWALT OR ITW CONCRETE SCREW STEEL 1

0.075"
K #10 PPH SELF-DRILLING SMS STEEL
L #8 X 3" PH SHEET METAL SCREW STEEL 1.62"

0.075"
0.071"
X STEEL STUD Min. Thk .033" (ASTM A653 GRADE 33 Fy=33 Ksi Min, Fu=45 Ksi Min) STEEL
1 FRAME - HEAD & SIDE JAMBS* - #UU0400 PVC

0.059"

2.18"
4 FRAME BOTTOM SILL* - #UU0401 PVC
8 5" FIXED & OPERABLE PANEL TOP RAIL* - #UU0403 PVC
10 3" FIXED & OPERABLE PANEL STILE* - #UU0402 PVC
11 7" FIXED & OPERABLE PANEL BOTTOM RAIL* - #UU0404 PVC

4.1"
7"
FRAME
4

6.25"
13 FIXED PANEL SUPPORT* - #UU0409 PVC

5"
0.071"
14 ROLLER TRACK *- #UU0406 PVC
15 SCREEN TRACK HEAD & SILL* - #UU0408 PVC
16 GLAZING BEAD* - #UU0410 PVC

0.063"
0.91"
18 INTERIOR INTERLOCK* - # UU0405 PVC 1.23"
0.071"

0.89"
19 LOCK STILE INSERT *- #UU0417 PVC
20 SASH STOP* - #UU0416 PVC

1.16"
21 ROLLER TRACK CAP SS
23 HANDLE SET - SIGNATURE TOP LOCK - #UU0244 - REINFORCEMENT
TOP RAIL 46
24 2-POINT LOCK - 1.62" 8 JAMB STILE
25 KEEPER - BOTTOM RAIL
11 0.91"
26 ROLLER NYLON 0.07"

0.47"

5.33"
27 WEEP COVER* PVC
Z:\2023 FBC Drawings\Associated Materials, Inc\FL-12323 R9\FL-12323.30-32.dwg

0.89"
36 FRAME WEATHERSTRIPPING - AMESBURY .187" X .240" G2 FIN PILE - 0.59"

0.125"
37 FRAME WEATHERSTRIPPING - AMESBURY .187" X .240" G2 FIN PILE - 0.63"

1.03"
0.07"
38 INTERLOCK BULB SEAL - AMESBURY 91500 -
REINFORCEMENT

2.08"
45 INTERIOR JAMB POCKET COVER* - # UU0416 PVC 50 INTERLOCK

0.625"
46 3" JAMB STILE REINFORCEMENT - # UY0096 STEEL SCREEN TRACK
47 3 LITE MULLION* - # UU0413 PVC 15 LOCK STILE INSERT
19
48 SCREW COVER* - #UU0412 PVC

© 2012 R.W. Building Consultants Inc.


50 3" INTERLOCK STILE REINFORCEMENT - # UY0098 STEEL MULLION
0.46" 47 0.125"
56 MULLION REINFORCEMENT - # UY0118 ALUM

0.067"

2.02"
* THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE REINFORCEMENT
56 MULLION
PRODUCED BY EXTRUDERS LICENSEES IN "AAMA CERTIFICATION PROGRAMS FOR 2.48"

0.55"
RIGID PVC EXTRUSIONS". 0.85"

0.067"

0.88"
0.81"

0.86"
0.55" 2.07"
0.07"
COVER POCKET COVER INTERLOCK
48 45 20 & SASH STOP
18 ROLLER TRACK FIXED PANEL GLAZING BEAD