Solenod-valve.
md 2025-06-06
Purchasing Checklist – High-Pressure Solenoid Valve
for Nitrogen (-40 °C, GOST Class A)
Valve Specifications
1/2" nominal port size (DN15)
2/2-way Normally Closed (NC)
Fully welded stainless steel body (SS316/316L)
Media: Nitrogen gas
Operating Pressure: ≥ 950 psi (65 bar)
Temperature Range: ≥ -40 °C
Leakage Class: Class A (zero leakage / bubble tight)
Seal material: PTFE or PEEK (low-temperature compatible)
End connections: Butt-weld or socket-weld (no threads)
Certifications & Compliance
GOST-R and/or TR CU 032/2013
ATEX/IECEx (if hazardous area)
IP65 or higher protection (coil/enclosure)
Manufacturer-provided leakage test certificate
Optional
Coil with frost protection or heating element
Manual override for emergency operation
Mounting bracket or frame included
📄 Technical Specification – Solenoid Valve for High-
Pressure Nitrogen
General
Application: Shutoff valve for nitrogen gas supply
Media: Nitrogen (inert gas)
Valve Type: Solenoid, 2/2-way, Normally Closed
Leak Class: GOST-K Class A (zero leakage, bubble-tight)
Process Conditions
Parameter Value
1/3
[Link] 2025-06-06
Parameter Value
Pressure 950 psi (≈65 bar)
Temperature Range -40 °C to +180 °C
Valve Size 1/2" (DN15)
Flow Direction Unidirectional
Mounting Position Any (preferably upright)
Certification *GOST, **TR CU 012/2011, *Ex IIC T4
Hazardous Zone Zone 1 / Zone 2
Material Requirements
Body: Stainless Steel 316 or 316L, fully welded
Seal: PTFE or PEEK (for low temp and gas compatibility)
Internal parts: Stainless steel or compatible non-reactive materials
Connections
Welded ends (butt-weld or socket-weld) – no threaded connections
Electrical & Enclosure
Coil Voltage: Specify (TBA)
Ingress Protection: IP65 minimum
Options: Coil heating, manual override
Solenoid Valve Options – Welded Stainless, Nitrogen Gas, -40 °C, GOST
Class A leakage
Summary Requirements
Fluid: Nitrogen gas
Pressure: 950 psi (65 bar)
Temperature: -40 °C minimum
Valve Size: 1/2" (DN15)
Construction: Fully welded stainless steel (316/316L)
Leakage Class: GOST-K Class A (zero leakage)
Seal Material: PTFE or PEEK
Connection: Butt-weld or socket-weld (no threads)
Certifications: GOST-R / TR CU 032/2013 / ATEX optional
Option 1 – Rotex 20116V01-W
Type: 2/2 NC solenoid valve
Body: Fully welded stainless steel 316
2/3
[Link] 2025-06-06
Seal: PTFE
Temp Range: -55 °C to +180 °C
Pressure: Up to 400 bar
Connection: Welded ends
Leakage Class: Class A (zero)
Certifications: GOST-R, TR CU, SIL, ATEX (optional)
Link: [Link]
Option 2 – Bürkert Type 5406 (Cryogenic Version)
Type: 2/2 NC, direct-acting solenoid valve
Body: Stainless steel 316L, optional welded ends
Seal: PTFE / PEEK
Temp Range: -50 °C to +150 °C
Pressure: Up to 100 bar
Connection: Weld ends (DIN/ANSI)
Leakage Class: Class A
Certifications: GOST, TR CU on request, ATEX optional
Link: [Link]
Option 3 – ASCO 327 Cryogenic Stainless (Welded Custom Variant)
Type: 2/2 NC solenoid valve
Body: Stainless steel 316L, welded construction on request
Seal: PTFE (cryogenic rated)
Temp Range: -50 °C to +180 °C
Pressure: Up to 100 bar
Connection: Welded tube or flange (custom options)
Leakage Class: Class A
Certifications: GOST-R, TR CU, ATEX, PED, SIL
Link: [Link] Emerson
Notes on Explosion Protection (Ex IIC T4)
Prefer welded ends over threaded for leak-proof operation under pressure and thermal cycling.
Confirm seal compatibility for -40 °C Enviroment.
Request GOST leakage certificates and test data for Class A performance.
Zone 1 or 2 use requires Ex d or Ex mb certified coils rated IIC T4.
IIC group includes the most explosive gases (e.g., hydrogen, acetylene).
T4 means max surface temperature ≤135 °C.
All selected valves offer coil enclosures or flameproof housings for compliance.
For GOST zones, confirm TR CU 012/2011 certificate availability with vendor.