0% found this document useful (0 votes)
57 views2 pages

Termostat en

The document is an installation manual for the RT510 and RT510RF programmable thermostats, detailing their features, wiring diagrams, and operational modes such as manual, automatic, frost protection, and holiday settings. It includes technical specifications, safety information, and instructions for pairing the thermostat with the RXRT510 receiver. Users are guided on how to set up and program the devices, ensuring compliance with national and EU regulations.

Uploaded by

Norbert
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
57 views2 pages

Termostat en

The document is an installation manual for the RT510 and RT510RF programmable thermostats, detailing their features, wiring diagrams, and operational modes such as manual, automatic, frost protection, and holiday settings. It includes technical specifications, safety information, and instructions for pairing the thermostat with the RXRT510 receiver. Users are guided on how to set up and program the devices, ensuring compliance with national and EU regulations.

Uploaded by

Norbert
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

N

N
Button functions RT510 Wiring diagram L
AC 230 V 7 8
AC 230 V
RT510/RT510TX Thermostat RXRT510 Receiver L

Thermostat
RT510
3
Model: RT510 (Wired, electronic thermostat - programmable)

Thermostat
Thermostat
RT510
RT510
MAX
RT510RF (Wireless, electronic thermostat - programmable) 1 4 3 (1) A

Thermostat
SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING

Thermostat
MAX

RT510
Press or to set day of the week.

RT510
2 5

NO
COM
3 (1) A

NC
Thermostat
RT510

NO
COM
NC
Press SELECT to confirm.
6 7 SELECT SET TEST / PAIRING

NO
COM
NC
8 9 9 10
or M

NO
COM
NC
SELECT SET TEST / PAIRING

OR
or M
N

6. When in Manual Mode, N


1. Boost function
2. Manual Mode ON will turn the boiler on. SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING

3. Frost protection / Holiday Mode 7. When in Manual Mode,


4. Increase button OFF will turn the boiler off. RT510RF Wiring diagram Thermostat will return to the main screen.
5. Decrease button 8. Receiver operates in automatic mode
according to the thermostat Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done. AC 230 V
Press SET to confirm.
9. Receiver output is controlled L
AC 230 V
by the On/Off slide switch. L

Programming - automatic mode


Installation Manual LCD Icon description
I 2018

In this mode, user can set the schedules for thermostat


L (temperature
COM setpoints for specific periods of

Thermostat
L

RT510TX

RXRT510
Thermostat
time). To do this, firstly choose programming mode: “5-2” (business days + weekend) or “24h” (each

Receiver
COM

Thermostat

RXRT510
RT510TX

Receiver
RT510TX

RXRT510
Receiver
day separately) using DIP switch no. 1. Programmed schedules should
MAX use all time periods.
1. Day of the week 16 (5) A

DISTRIBUTOR OF SALUS CONTROLS: Importer: 15 14 13 12 2. Program number NO 1 N2 NO


11 N
QL CONTROLS Sp. z o.o., Sp. k. SALUS Controls plc 3. Program indicator
Rolna 4, Salus House, Dodworth Business Park 1 10
43-262 Kobielice, Whinby Road, Barnsley S75 3SP,
4. Settings
9
5. Temperature measured / set N or M
Poland United Kingdom
8
6. Boost function
2 7 7. Low battery status AC 230 V N
L
AC8.230Wireless
V connection with the receiver
L 9. Heating Mode On
SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING

3 4 5 6
10. Manual Mode On AC 230 V Use the or button to select day / days
L from which you want to start programming.
www.salus-controls.eu 11. Holiday Mode On
12. Frost Protection Mode On L COM Press the SET button to start programming.

Thermostat
Thermostat
SALUS Controls is a member of the Computime Group. L COM

RT510TX

RXRT510
Thermostat

Receiver

Thermostat
RT510TX

RXRT510
13. Temperature

Receiver
unit SELECT SET TEST / PAIRING

RXRT510
RT510TX

Receiver

RT510
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to MAX
14. AM / PM 16 (5) A
change specification, design and materials of products listed in this brochure without prior notice.
15. Clock 3 SELECT SET 4 TEST / PAIRING

NO N NO MAX
N 3 (1) A

Thermostat
RT510

NO
COM
NC
N OR
or M
Introduction RT510 Terminals description
RT510 / RT510RF is a programmable room thermostat used to control room temperature. Device N

NO
COM
NC
launching heating system by shorting terminal blocks, simultaneously informing the action and
SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING

showing this information on the LCD display. Extended features allows us to use various operating modes Terminal Description or M Use the or button to set the hour
- automatic (time schedules), manual, frost protection or holiday. Before use please read this manual 1 - COM Common Terminal AC 230 V to start the program #1.
carefully. Use only AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot
2 - NC Switched Live OFF
L Setting the time N
located under the cover. Do not use rechargeable batteries. Press SELECT to confirm.
SELECT SET TEST / PAIRING
3 - NO Switched Live ON
Product compliance 1 2

Thermostat
5 6

RT510
Directives: EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. SELECT SET TEST / PAIRING

Full information is available on the website www.saluslegal.com MAX


3 (1) A
Thermostat

Safety Information
RT510

NO
COM
NC
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition.
Product for indoor use only. Installation must be carried out by a qualified person in accordance to national SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING
SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING

and EU regulations. Press or to select the hour format.


RXRT510 Receiver terminals description Use the or button to set the minutes
NO
COM
NC

3 sec 3 sec to start the program #1.


or M
Technical specification Terminal Description Press the buttons SELECT and SET Press SELECT to confirm.
N together for 3 sec.SELECT SET TEST / PAIRING
SELECT SET TEST / PAIRING

RT510 Thermostat RT510TX Thermostat NO Switch Terminal 7 8


3 SELECT SET 4 TEST / PAIRING
SELECT SET TEST / PAIRING
Thermostat supply 2 x AA alkaline batteries 2 x AA alkaline batteries COM Common Switch Terminal
NO COM L N
Thermostat rating max 3 (1) A - L, N Supply (230 V AC)
Voltage free
Outputs NO / COM / NC -
terminals SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING

SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING

Temperature range 5 - 35°C 5 - 35°C Use the or button


Press or to set the hour. to set the temperature for program #1.
Temperature accuracy 0.1°C or 0.5°C 0.1°C or 0.5°C
DIP Switch Settings Press SELECT to confirm.
Hysteresis ±0.25°C or ±0.5°C ±0.25°C or ±0.5°C Press SELECT to confirm. TEST / PAIRING
The DIP switches are found on the rear of your thermostat. ON SELECT SET TEST / PAIRING
SELECT SET

Radio frequency - 868 MHz 24H +/-0.25°C 9 10


5 6 TEST / PAIRING
Dimension [mm] 120x96x27 120x96x27 The DIP switch number 1 is used to change the schedule mode: 5-2 SELECT SET TEST / PAIRING
SELECT SET

mode (business days + weekend) or for each day separately mode.


RXRT510 Receiver
DIP switch number 2 is used to change the span (temperature
Receiver supply 230 V AC accuracy) of your thermostat from the default ±0.5°C to ±0.25°C.
This may cause your boiler to operate more frequently. 5-2 +/-0.5°C
Receiver rating max 16 (5) A TEST / PAIRING TEST / PAIRING
SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING

2
SELECT SET SELECT SET

Outputs Voltage free NO / COM terminals 1 Follow steps 4-9,


Press or to set the minutes. to define programs 2-6.
Radio frequency 868 MHz
Press SELECT to confirm. Press SET button to end programming.
Dimension [mm] 96x96x27 Press SELECT to confirm.
SELECT SET TEST / PAIRING
Temporary Override mode Frost Protection RT510TX thermostat pairing with the receiver Installer mode
This function is available only in automatic mode (schedule). If a new setpoint temperature will be set
during the schedule - it will be maintained until next time interval starts according to programmed Temperature of the Frost Protection mode is set as default at 5°C. This temperature can be changed Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done. 1 2
schedule. in Installer Mode in d03 parameter. 3 sec
If you bought the RT510TX and RXRT510 seperately then pair as follows. Please make sure that
receiver switchers are set on AUTO and ON position. Connect your receiver to power supply - LED
indicator will flash red.

Begin the pairing process SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING

3 sec 3 sec

SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING


SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING
Press three buttons at the same time
for 3 seconds.
Using or buttons set new setpoint After new setpoint temperature set, Press button to turn On Frost Using SELECT button choose the parameter.
temperature. thermostat will return to the main screen. Protection mode.

SET Temporary Override mode will be disabled when new schedule will be set.
TEST / PAIRING 3 4
Turning Off the Frost Protection mode SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING

TEST / PAIRING
(the pairing process takes up to 9 minutes)
3 sec
SELECT SET TEST / PAIRING
Manual Mode and setting setpoint temperature Press and hold TEST/PAIRING button
In this mode thermostat does not work according to the programmed schedule but it will maintain for 3 seconds. SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING

selected temperature.
SELECT SET TEST / PAIRING Using or buttons set a parameter value.
End the pairing process
SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING

1 2
Press button again to turn Press SET to confirm.
Off Frost Protection mode. TEST / PAIRING
SELECT SET TEST / PAIRING
SELECT SET
SELECT SET TEST / PAIRING
5 6
SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING
Sleep mode

3
SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING

Press button to activate the Manual Mode. 3 sec


3 sec
3 4 SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING

TEST / PAIRING
SELECT SET TEST / PAIRING
Once devices are successfully paired, Follow steps 2-5, to set next parameters.
SELECT SET
LED on the receiver will go solid red. To exit the installer mode, wait 10 seconds
Press and hold TEST / PAIRING button for - thermostat will return automatically
SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING 3 seconds to end the pairing process. Press SELECT to confirm. to the main screen.
3 sec
Thermostat is in sleep mode.
SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING Hold and buttons simultaneously
for 3 seconds to start the sleep mode.
Using or buttons set new setpoint After new setpoint temperature set,
Test the pairing process
dxx Function Parametr Default
temperature. thermostat will return to the main screen. SELECT SET TEST / PAIRING
When the sleep mode is activated, all thermostat functions are paused. value
SET
To turn off the Manual Mode press
TEST / PAIRING
button. Once the manual mode is off, the hand iconSELECT on SET TEST / PAIRING d01 Temperature display increments 0.1°C or 0.5°C 0.5°C
the thermostat will disappear.
TEST / PAIRING d02 Temperature offset +/- 3.0°C 0.0°C

TEST / PAIRING TEST / PAIRING


d03 Frost Protection setpoint temperature 5.0°C - 17.0°C 5.0°C
SELECT SET SELECT SET

Hourly temperature Override Mode (+Hr)


This function is available in Automatic and Manual Mode. It is used to change the setpoint temperature ON OFF

for a specified number of hours (up to 9 hours). Once that time is over, thermostat returns to previous
Reset of the RT510 thermostat
SELECT SET TEST / PAIRING

SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING AUTO MANUAL

mode.
Press any key to deactivate sleep mode. Thermostat will return to the previous mode. Press TEST / PAIRING button
1 2 to check the connection with 1 sec
the receiver.

Press the RESET button once. You can use a paper


clip. Your thermostat will be reset and will start up
Holiday Mode automatically.
In this mode the “frost protection” temperature is maintained for a specific number of days.
SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING SELECT SET RESET

Press +Hr button to set number of hours for Using or button set a new setpoint
temperature override (e.g. to set up override temperature for override. 1 2
for 3 hours, press the button 3 times).
ON OFF

SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING

3 sec
AUTO MANUAL

3 4
SELECT SET TEST / PAIRING
Press TEST / PAIRING button
again to return to the main 1 sec
Reset of the RT310TX thermostat
TEST / PAIRING TEST / PAIRING
screen.
SELECT SET SELECT SET

Hold down button for 3 seconds Use or button to set the number
to activate the Holiday Mode. of days for Holiday Mode. Remove the batteries without pressing any button.
SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING
If you purchased an RXRT510 or RT510TX and intend pairing with other devices in the 5x5 range, please Wait 2 minutes and insert the batteries again.
3 SELECT SET
4 TEST / PAIRING refer to the Receiver Units manual or the relevant manuals available at www.salus-controls.eu Your device will be restarted.
Press SET button
to confirm. SELECT SET TEST / PAIRING

SELECT SET TEST / PAIRING

+ − When you want to change the batteries


Turning off hourly temperature override mode before time’s up TEST / PAIRING your device will use the internal memory to
SELECT SET − + backup your settings. You have 30 seconds
SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING
to change the batteries before losing your
settings.
SELECT SET TEST / PAIRING

Press SET button to confirm.


You can set up to 31 days.
SELECT SET TEST / PAIRING SELECT SET TEST / PAIRING

Press the + Hr button until number of hours To turn off the Holiday Mode, hold down button for 3 seconds. The airplane icon should
disappears from display. disappear from the display.