FHC - Hydraulic Calculation Report
Submitted by FHC user number: 9991 Project: Wet Riser Project
igorcauret@gmail.com Project Ref ---
Area Ref: Most Unfavourable
Inst. Number: 1
Tel:
Fax:
Project Data and Design Parameters
Project name : Wet Riser Project
Area reference : Most Unfavourable
Address / location : ---
Project number : ---
Installation number(s) : 1
Drawing number(s) : ---
Issue no / date : ---
Designers reference : ---
Project Data File : WET RISER PROJECT.FHC
Hazard classification : Domestic
Design authority : CP52:2004 Singapore Sprinkler Rules
Insurance company : ---
Specified density of discharge : 0.00 mm/min (l/min/m2)
Assumed maximum area of operation : 0.00 m2
Number of operating sprinkler heads : 3
Maximum area covered per head : 0.00 m2
Highest head / nozzle above source : 0.00 m
Number of pipes in system : 7 from 65 to 150 mm
Pressure loss equation used : Hazen-Williams
Fluid : Water
Pipe Data Table : CP52.PDT
Maximum fluid velocity : 0.00 m/s in pipe 0 0
Volume of pipework and fittings : 0.23 m3
Elbows are welded for : 65 mm and above
Comment : ---
Checked by & Date :
Source duty = 0.0 l/min @ 0.000 bar at node no 100
Canute FHC Ver: 1.8.6 13 August, 2025 - 13:58
www.canutesoft.com Page: 1/3
FHC - Hydraulic Calculation Report
Submitted by user number: 9991 Project: Wet Riser Project
igorcauret@gmail.com Project Ref ---
Tel: Area Ref: Most Unfavourable
Fax: Inst. Number: 1
Operating Sprinkler Heads, Nozzles and Hydrants
Head|Node| Size | 'K' |F l o w|A r e a|Density mm/min|Pressure bar|Heights|Pipe
no | no | mm | factor| l/min | m2 |Req.d Actual| Min Actual| m | no
1 120 384.86 0.0 0.000 0.00 0.00 3.50 0.000 0.000 2
2 131 384.86 0.0 0.000 0.00 0.00 3.50 0.000 0.000 4
3 142 384.86 0.0 0.000 0.00 0.00 3.50 0.000 0.000 6
0 heads are under the required density / minimum pressures
Canute FHC Ver: 1.8.6 13 August, 2025 - 13:58
www.canutesoft.com Page: 2/3
FHC - Hydraulic Calculation Report
Submitted by user number: 9991 Project: Wet Riser Project
igorcauret@gmail.com Project Ref ---
Tel: Area Ref: Most Unfavourable
Fax: Inst. Number: 1
Hydraulically Significant Pipes in System
NUMBERS | P I P E | F L O W |DIMENSIONS|ANGLE| VALUES |HEIGHT M|PRESSURES BARS
Pipe|Start|Size Type| L/min | Length VJ|Dir. | Eq.len | Start | Start Frict
no | End |Bore 'C'| Vel m/s |EL T VT|Slope| mbar/m | End | End Static
Maximum flow rate error at nodes : 0.00000 L/min
Maximum pressure drop error at nodes : 0.00000 bar
Maximum pressure drop error in loops : 0.00000 bar
Overall head flow balance error : 0.00000 %
Canute FHC Ver: 1.8.6 13 August, 2025 - 13:58