Wet Riser Project

The hydraulic calculation report for the Wet Riser Project indicates that the system's source duty is 0.0 l/min at 0.000 bar, with no operating sprinkler heads meeting the required density or minimum pressures. The design parameters include a specified discharge density of 0.00 mm/min and a maximum fluid velocity of 0.00 m/s. The report highlights that there are 7 pipes in the system, with a total volume of 0.23 m3, but no effective flow or pressure is achieved in the current configuration.

Uploaded by

snw1975
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
22 views3 pages

Wet Riser Project

The hydraulic calculation report for the Wet Riser Project indicates that the system's source duty is 0.0 l/min at 0.000 bar, with no operating sprinkler heads meeting the required density or minimum pressures. The design parameters include a specified discharge density of 0.00 mm/min and a maximum fluid velocity of 0.00 m/s. The report highlights that there are 7 pipes in the system, with a total volume of 0.23 m3, but no effective flow or pressure is achieved in the current configuration.

Uploaded by

snw1975
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

FHC - Hydraulic Calculation Report

Submitted by FHC user number: 9991 Project: Wet Riser Project


igorcauret@gmail.com Project Ref ---
Area Ref: Most Unfavourable
Inst. Number: 1

Tel:
Fax:

Project Data and Design Parameters


Project name : Wet Riser Project
Area reference : Most Unfavourable
Address / location : ---
Project number : ---
Installation number(s) : 1
Drawing number(s) : ---
Issue no / date : ---
Designers reference : ---
Project Data File : WET RISER PROJECT.FHC
Hazard classification : Domestic
Design authority : CP52:2004 Singapore Sprinkler Rules
Insurance company : ---
Specified density of discharge : 0.00 mm/min (l/min/m2)
Assumed maximum area of operation : 0.00 m2
Number of operating sprinkler heads : 3
Maximum area covered per head : 0.00 m2
Highest head / nozzle above source : 0.00 m
Number of pipes in system : 7 from 65 to 150 mm
Pressure loss equation used : Hazen-Williams
Fluid : Water
Pipe Data Table : CP52.PDT
Maximum fluid velocity : 0.00 m/s in pipe 0 0
Volume of pipework and fittings : 0.23 m3
Elbows are welded for : 65 mm and above
Comment : ---
Checked by & Date :

Source duty = 0.0 l/min @ 0.000 bar at node no 100

Canute FHC Ver: 1.8.6 13 August, 2025 - 13:58


www.canutesoft.com Page: 1/3
FHC - Hydraulic Calculation Report
Submitted by user number: 9991 Project: Wet Riser Project
igorcauret@gmail.com Project Ref ---
Tel: Area Ref: Most Unfavourable
Fax: Inst. Number: 1

Operating Sprinkler Heads, Nozzles and Hydrants


Head|Node| Size | 'K' |F l o w|A r e a|Density mm/min|Pressure bar|Heights|Pipe
no | no | mm | factor| l/min | m2 |Req.d Actual| Min Actual| m | no
1 120 384.86 0.0 0.000 0.00 0.00 3.50 0.000 0.000 2
2 131 384.86 0.0 0.000 0.00 0.00 3.50 0.000 0.000 4
3 142 384.86 0.0 0.000 0.00 0.00 3.50 0.000 0.000 6

0 heads are under the required density / minimum pressures

Canute FHC Ver: 1.8.6 13 August, 2025 - 13:58


www.canutesoft.com Page: 2/3
FHC - Hydraulic Calculation Report
Submitted by user number: 9991 Project: Wet Riser Project
igorcauret@gmail.com Project Ref ---
Tel: Area Ref: Most Unfavourable
Fax: Inst. Number: 1

Hydraulically Significant Pipes in System


NUMBERS | P I P E | F L O W |DIMENSIONS|ANGLE| VALUES |HEIGHT M|PRESSURES BARS
Pipe|Start|Size Type| L/min | Length VJ|Dir. | Eq.len | Start | Start Frict
no | End |Bore 'C'| Vel m/s |EL T VT|Slope| mbar/m | End | End Static
Maximum flow rate error at nodes : 0.00000 L/min
Maximum pressure drop error at nodes : 0.00000 bar
Maximum pressure drop error in loops : 0.00000 bar
Overall head flow balance error : 0.00000 %

Canute FHC Ver: 1.8.6 13 August, 2025 - 13:58


www.canutesoft.com Page: 3/3