0 - 4 8 0 A B B S O L A R I N V E R T E R S
—
ABB string inverters
—
SOL AR INVERTERS TRIO-TM-50.0-400
ABB string inverters TRIO-TM-60.0-480
TRIO-TM-50.0-400 / TRIO-TM-60.0-480 50 to 60 kW
50 to 60 kW —
Technical data and types
latest three-phase string solution Absolute maximum DC input voltage (Vmax,abs) 1000 V
Start-up DC input voltage (Vstart) 420…700 V (Default 420 V) 420…700 V (Default 500 V)
for cost efficient large Operating DC input voltage range (Vdcmin ...Vdcmax) 0,7xVstart ...950 V (min 300 V) 0,7xVstart ...950 V (min 360 V)
Rated DC input voltage (Vdcr) 610 Vdc 720 Vdc
decentralized photovoltaic systems Rated DC input power (Pdcr) 52000 W 61800 W
Number of independent MPPT 3 (SX and SX2 version) / 1 (standard and SX version)
for both commercial and utility Maximum DC input power for each MPPT (PMPPT,max) 17500 W 21000 W
MPPT input DC voltage range (VMPPTmin ... VMPPTmax) at Pacr 480-800 Vdc 570-800 Vdc
applications. Maximum DC input current (I dcmax) for each MPPT 36 A
Maximum input short circuit current for each MPPT 55 A (165 A in case of parallel MPPT)
Number of DC input pairs for each MPPT 5
Screw terminal block (Standard and -S version)
DC connection type
or PV quick fit connector 3) (-SX and SX2 version)
Input protection
Reverse polarity protection Yes, from limited current source
Input over voltage protection for each MPPT - varistor Yes, 1 for each MPPT
Input over voltage protection for each MPPT - plug In modular
Type 2 (option) with monitoring
surge arrester
Photovoltaic array isolation control According to local standard
01
DC switch rating for each MPPT (version with DC switch) 60 A / 1000 V for each MPPT (180 A in case of parallel MPPT)
Fuse rating (version with fuses) 15 A / 1000 V
Output side
— This new addition to the TRIO family, with 3 Ethernet, RS485) combined with a Sunspec compliant AC grid connection type Three-phase (3W+PE or 4W+PE)
01 TRIO-TM-50.0/60.0 Rated AC power (Pacr @cosf=1 ) 50000 W 60000 W
outdoor string inverter independent MPPT and power ratings of up to 60 kW Modbus protocol (RTU/TCP) allow the inverter to be
Maximum AC output power (Pacmax @cosf=1) 50000 W 60000 W
(480 V version), has been designed with the objective easily integrated with any third party monitoring and Maximum apparent power (S max) 50000 VA 60000 VA
to maximize the ROI in large systems with all the control systems. Rated AC grid voltage (Vac,r) 400 V 480 V
advantages of a decentralized configuration for both AC voltage range 320...480 V 1) 384…571 V 1)
Maximum AC output current (I ac,max) 77 A
rooftop and ground-mounted installations. Improved commissioning and maintenance
Contributory fault current 92 A
Thanks to the build-in Web User Interface (WUI) the Rated output frequency (fr) 50 Hz / 60 Hz
Modular design installer can commission the inverter wirelessly and Output frequency range (fmin ...fmax) 47...53 Hz / 57…63 Hz 2)
The TRIO-TM-50.0/60.0 has a modular design to change advanced parameters by using any standard Nominal power factor and adjustable range > 0.995; 0...1 inductive/capacitive with maximum S max
Total current harmonic distortion <3%
guarantee maximum flexibility, thanks to the different WLAN enabled device (smartphone, tablet or PC). Maximum AC cable 95 mm2 copper only (150 mm2 copper/alluminum with TRIO-AC-WIRING-KIT)
versions available. Integrated logging capability allows remote AC connection type Screw terminal block, cable gland
The separate and configurable AC and DC monitoring of the plant without the need of any Output protection
Anti-islanding protection According to local standard
compartments increase the ease of installation and additional external loggers.
Maximum external AC overcurrent protection 100 A
maintenance with their ability to remain separately Remote firmware update of the inverter system and Output overvoltage protection - varistor Yes
wired from the inverter module inside the system. components via Aurora Vision®. Output overvoltage protection - plug In modular surge arrester Type 2 (option) with monitoring
The TRIO comes with the most complete wiring box Operating performance
Maximum efficiency (hmax) 98.3% 98.5%
configurations available including up to 15 DC inputs Highlights Weighted efficiency (EURO) 98.0% / - 98.0% / -
with fast connectors, string protection fuses, AC and • 3 Independent MPPT Communication
DC switches and type II AC and DC surge arresters. • Transformerless inverter Embedded communication interfaces 2x RS485, 2x Ethernet (RJ45), WLAN (IEEE802.11 b/g/n @ 2,4 GHz)
Communication protocols Modbus RTU / TCP (Sunspec compliant); Aurora Protocol
• Double stage topology for a wide input range
Remote monitoring services Standard level access to Aurora Vision monitoring portal
Design flexibility • Large set of specific grid codes available which can Integrated Web User Interface; Display (option);
Advanced features
The double stage conversion topology offers the be selected directly in the field Embedded logging and direct transferring of data to Cloud
Environmental
advantage of a wide input voltage range for maximum • Separate AC and DC compartments are available in -25...+60°C (-13...140 °F) -25...+60°C (-13...140 °F)
Ambient temperature range
flexibility of system design. different configurations with derating above 45 °C (113 °F) with derating above 45 °C (113 °F)
Relative humidity 4%... 100% condensing
The TRIO-TM comes with a forced air cooling system, • Both vertical and horizontal installation
Sound pressure level, typical 75 dB(A) @1 m
used also in the previous TRIO products, designed for • 2 available sizes, 50 and 60 kW with 400 and 480 Vac Maximum operating altitude 2000m / 6561ft
a simple and fast maintenance, allowing a maximum of output voltage, respectively Physical
flexibility of plant design. The inverter comes with • Wireless access to embedded user interfaces Environmental protection rating IP65 (IP54 for cooling section)
Cooling Forced air
mounting supports for both horizontal and vertical • Ethernet daisy chain enabled Dimension (H x W x D) 725 mm x 1491 mm x 315 mm / 28.5” x 58.7” x 12.4”
installations, which allow for the best use of space • Modbus TPC/RTU Sunspec compliant 95 kg / 209 lbs overall, 66 kg / 145 lbs electronic compartment,
Weight
available beneath the solar panels. • Remote monitoring and firmware update via Aurora 15 kg / 33 lbs AC wiring box (full optional), 14kg / 31 lbs DC wiring box (full optional)
Mounting system Wall bracket, horizontal support
Embedded multi communication interfaces (WLAN, Vision® (logger free)
P R O D U C T F LY E R F O R T R I O -T M - 5 0 . 0 - 4 0 0 / T R I O -T M - 6 0 . 0 - 4 8 0 A B B S O L A R I N V E R T E R S
—
ABB TRIO-TM-50.0-400 / TRIO-TM-60.0-480 string inverter block diagram
L2 L2 L2 N N, S N N, S
IN1- IN1-
IN1- L3 L3 L3 PE PE
IN1- IN2- IN1- IN2-
IN3- IN3-
Standard -S version
IN2+
IN2-
L1 L1, S
L2 L2, S
IN3- PE
PE
IN1A(+)
IN1B(+)
DC/DC DC/AC
IN1+ Current reading DSP DSP
contr. contr.
IN1E(+) OVP monitoring
-SX version
IN2A(+)
IN2B(+) Control circuit
IN2+
IN2E(+)
IN3A(+)
IN3B(+)
IN3+
1_RS485
IN3E(+) + T/R
- T/R
GND
IN1A(-)
IN1B(-) 2_RS485
µP + T/R
2 1 3
- T/R
IN1E(-)
GND
IN2A(-)
IN1- Remote control
IN2B(-)
+ R1
IN2-
+ R2
IN2E(-)
IN3- GND
IN3A(-) Alarm
IN3B(-) N.C
Communication N.O
IN3E(-)
platform
C
1 Inverter power module
Aux 2 DC wiring box
N.C
N.O 3 AC wiring box
C
Ethernet Ethernet WLAN
Version -SX
—
Technical data and types