This document is a programming manual for the KDT EVO controller. It explains how to configure the controller's parameters, including general parameters, door parameters, movement parameters, and safety parameters. Each parameter describes its function, allowed values, and the access level required to modify it. The manual provides examples and a guide on how to navigate the menus to find and change the settings.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views32 pages

De950110p07 KDT Evo Manual Eng 1 - 5

This document is a programming manual for the KDT EVO controller. It explains how to configure the controller's parameters, including general parameters, door parameters, movement parameters, and safety parameters. Each parameter describes its function, allowed values, and the access level required to modify it. The manual provides examples and a guide on how to navigate the menus to find and change the settings.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 32

Programming Manual. KDT EVO Manual Prog.KDT EVO Rev.

7 October 9, 2023

KDT EVO Maneuver


Programming Manual version 1.5

DE950110P07
*DE950110P07*

ESP
How to use the manual
Each parameter is described as follows:

XX.XX.XX–Parameter name

Parameter description(It can include allowed values and even notes)

EXAMPLE: Represents a possible situation

FACTORY DEFAULT: Factory settings

Access level - Tool - Connection


(Required level to view Required tool (Location)
or modify the parameter to view or modify
the parameter

Example

02.02.01.03 - Attempts to close doors

Adjust the number of times it will attempt to close the doors before entering the state of
locked doors
FACTORY DEFAULT: 10

Basic Intermediate Advanced Administrator Console PC M2CS Maneuver Cabin Hydraulic Electric

Location to make the connection


Levels without access to parameters (it can be from both sites)
(not marked)
Necessary tool (can be modified from Console and PC)

Levels with access to parameters


marked

2
01 - MONITOR

01.01 - E STATE..................................................................................................................................................... 8
01.02 - S UBESTADO................................................................................................................................................ 8
March 1stOUT OF SERVICE.......................................................................................................................... 8
01.04 - E MACHINE STATE............................................................................................................................... 8
01.05 - S STATE OF THE MACHINE.......................................................................................................................... 8
01.09 - M POSITION MONITOR................................................................................................................................. 8
01.09.01 - Current plant ................................................................................................................................. 8
01.09.02 - Destination plant ............................................................................................................................... 8
01.09.05 - Magnetic zone................................................................................................................................. 8
01.14 - M OUTPUT MONITORS ................................................................................................................................... 8
01.14.01 - Direction instructions .................................................................................................................. 8
01.14.02 - Speed instructions ................................................................................................................. 8
01.14.50 - Operator control signal monitors............................................................................... 8
01.15 - M INPUT MONITOR................................................................................................................................ 8
01.15.01 - Series Monitor
01.15.02 - Position monitor................................................................. 9
01.15.06 - Inspection signal monitor ................................................................................................. 9
01.15.10 - Input monitor ................................................................................................................ 9
01.15.10.01 - Adjustment of the input to monitor
01.15.10.02 - Value of the monitored entry .......................................................................................................... 9
01.15.51 - Photocell monitor .................................................................................................................. 9
01.15.60 - Complete and overload monitor........................................................................................ 9
01.15.65 - Central entry monitor................................................................................................. 9
01.50 - M COUNTER MONITOR9
01.50.50 - Total number of maneuvers .............................................................................................. 9
01:50:55– Travel stopwatch (ms) ............................................................................................................. 9
01.50.70 - Errors CANC(%) ............................................................................................................................ 9
01.60 - R HISTORICAL RECORD OF EVENTS................................................................................................................... 9
01.60.01 - 01.60.32 - Event number 1 until Event number 32 ................................................................. 9
01.70 - M HARDWARE MONITOR.............................................................................................................................. 9
01.70.20 - Cabin CAN
01.70.40 - BUS SAR ....................................................................................................................................... 10
01.70.90 - micro SD ...................................................................................................................................... 10

02 - CONFIGURATION..................................................................................................................................... 11

02.01 - P PARAMETERSGGENERAL........................................................................................................................... 11
02.01.01 Type of maneuver .......................................................................................................................... 11
02.01.02 - Upper floor ............................................................................................................................ 11
02.01.04 - Plant Downtime ....................................................................................................... 11
02.01.06 - Mounting mode............................................................................................................................. 11
02.01.08 - Positioning mode........................................................................................................... 11
02.01.11 - Call Acceptance .............................................................................................................. 11
02.02 - P BARS.................................................................................................................................................. 11
02.02.01 - General parameters ................................................................................ 11
02.02.01.02 - Door closing time limit...................................................................................................... 11
02.02.01.03 - Attempts to close doors ................................................................................................................... 12
02.02.01.04 - Door lock time..................................................................................................................... 12
02.02.01.05 - Door unlocking time ............................................................................................ 12
02.02.01.07 - Photocell Attempts.......................................................................................................................... 12
02.02.01.08 - Time for door rest
02.02.01.10 - Synthesis of doors............................................................................................................................... 12

3
02.02.02 - Specific parameters for each plant.............................................................. 12
02.02.02.01 - 02.02.02.8 - Operator Control Doors Plant 0 to Operator Control Doors Plant7 ............... 12
02.02.50 - Control entries and exits of the operators ......................................................................... 12
02.02.50.03 - Photocell connection 1 ..................................................................................................................... 13
02.02.50.04 - Connection of photocell 2
02.03 - I INDICATIONS
02.03.02 - Displayy ......................................................................................................................................... 13
02.03.02.01 - 02.03.02.8 Symbol Plant 0 until Symbol Floor 7 ........................................................................ 13
02.03.03 - Acoustics...................................................................................................................................... 13
02.03.03.01 - 02.03.03.8 Synthesis Plant 0 until Synthesis Plant7 .......................................................................... 14
02.03.08 - Type of indication on external push buttons................................................................................ 14
02.03.09 - Positional indication on cabin push buttons............................................................................ 14
February 3, 2013– TFT 2.8 cabin............................................................................................................................. 14
02.03.13.01– Brillo.14
02.03.13.10– Background color .................................................................................................................................... 14
02.03.13.11– Font color ................................................................................................................................... 14
02.03.13.20– Address ............................................................................................................................................. 15
March 2, 2014– TFT 2.8 exterior........................................................................................................................... 15
02.03.14.01– Brillo.................................................................................................................................................... 15
02.03.14.10– Background color .................................................................................................................................... 15
02.03.14.11– Font color ................................................................................................................................... 15
02.03.14.20– Address ............................................................................................................................................. 15
02.03.15 - TFT 7 and 10 .................................................................................................................................... 15
02.03.15.01 - Themea .15
02.03.15.02 - Logo
02.03.15.03 - Configuration
02.03.15.04– Font color................................................................................................................................ 15
02.03.15.05– Background color .................................................................................................................................... 15
02.03.15.10– 02.03.15.14– Texto1
March 2, 2015– Advertisement text................................................................................................................................. 15
02.03.15.21– Duration of the announcement .......................................................................................... 16
02.03.15.50– Volume Adjustment........................................................................................................................... 16
02.03.15.51– Voice synthesis configuration ......................................................................................................... 16
02.03.15.90– Reset to factory settings .............................................................................................. 16
02.03.89– Floor indication ....................................................................................................................... 16
02.04 - R RETURNS AND AUTOMATIC MANEUVERS16
02.04.01 - Returns ...................................................................................................................................... 16
02.04.01.01 - Return Activation
02.04.01.02 - Return Plant................................................................................................................................. 16
02.04.01.03 - Time for return............................................................................................................................ 16
02.04.03 - Parked
02.04.03.01 - Entrance for parked 1
02.04.03.02 - Parking plant1 .16
02.04.03.50 - Park with doors closeds .............................................................................................................. 16
02.05 - P TRACTOR GROUP PARAMETERS................................................................................................................ 17
02.05.50 - Engine Configuration............................................................................................................... 17
02.05.50.01 - Selection of direct starting or E-T .................................................................................................... 17
02.05.50.10 - Star time ............................................................................................................................... 17
02.05.60 - Delay in engine disconnection............................................................................................... 17
02.05.65 - Delay of instructions after engine
02.05.71 - Slow startup time ....................................................................................................... 17
02.05.72 - Block valveo ...................................................................................................................... 17
02.05.72.01 - Exit for block valve controlo........................................................................................... 17
02.05.72.05 - Lock valve time at start................................................................................................ 17
02.05.80 - Safety valve test ....................................................................................................... 17
02.05.81 - Braking margin time .................................................................................................... 17

4
02.06 - B GARLIC CONSUMPTION...
02.06.01 - Cabin light............................................................................................................................... 18
02.06.01.01 - Cabin light time ................................................................................................................................ 18
02.06.03 - Time for low power consumption displays ........................................................................................ 18
02.07 - R ESCATES................................................................................................................................................. 18
02.07. 10 - Type of rescue ........................................................................................................................... 18
02.07. 20 - Automatic rescue due to decompensation ................................................................................ 18
02.07.20.01 - Departure for automatic rescue control .......................................................................................... 18
02.07.45 - Rescue in oil
02.07.45.02 - Automatically perform rescue
02.07.50 - Departure for rescue control ................................................................................................ 18
02.07.51 - Allow upward rescue in VF ............................................................................................. 18
02.08– RRESTRICTIONS ......................................................................................................................................... 19
02.08.40 - Entry to disable the upload............................................................................................... 19
02.10 - O SPECIFIC OPERATIVES OF THE INSTALLATION.................................................................................................. 19
02.10.01 - Evacuation Control in case of fire (EN81-73)....................................................... 19
02.10.01.01 - EN81-73 Operational Procedures............................................................................................... 19
02.10.01.02 - Main evacuation plant ............................................................................................................ 19
02.10.01.03 - Door to open in main evacuation floor ................................................................................ 19
02.10.01.04 - Main alarm signal..................................................................................................................... 19
02.10.01.06 - Alternative evacuation plant......................................................................................................... 19
02.10.01.07 - Door to open in alternative evacuation plan ............................................................................. 20
02.10.01.08 - Alternative alarm signal ................................................................................................................. 20
02.10.01.20 - Close doors in evacuation plantn .............................................................................................. 20
02.10.11 - Control of brake monitor contacts (A3)............................................................... 20
02.10.11.01 - Control of the brake monitor contacts (A3) .......................................................... 20
02.10.11.02 - Brake monitor control signal (1 of 2) ......................................................................................... 20
02.10.11.03 - Brake monitor control signal (2 of 2) ......................................................................................... 20
02.10.15 - Automatic entry control in inspection ............................................................................ 20
02.10.15.01 - Enabling automatic entry in inspection.............................................................................. 20
02.10.15.02 - Access hole detection signal................................................................................................. 20
02.10.15.03 - Permission signal to exit inspectionn ........................................................................................... 21
02.10.15.04 - Permission to leave inspection ......................................................................................................... 21
02.10.15.10 - Exit for commissioning after inspection......................................................................... 21
02.10.15.90 - Type of access hole detection contact .............................................................................. 21
02.10.33 - Anti-drift device control................................................................................................. 21
02.10.33.01 - Enablement of the drift prevention device operation............................................................................ 21
02.10.33.10 - Exit to extend antiderivativea ................................................................ 21
02.10.33.11 - Departure to collect anti-drift
02.10.33.30 - Anti-drift control input outside................................................................................................ 21
02.10.33.31 - Anti-drift control entry recorded .......................................................................................... 21
02.10.33.50 - Cable un-tensioning time......................................................................................................... 21
02.10.33.55 - Time for anti-loosening operation ............................................................................................. 22
02.10.35– Photoelectric barrier test ...................................................................................................... 22
02.10.35.01 - Enabling of photoelectric barrier testa .
02.10.35.10 - Departure to carry out the test.................................................................................................................... 22
02.10.35.20 - Entry 1 for barrier test ................................................................................................................. 22
02.10.35.21 - Entry 2 for barrier test ................................................................................................................ 22
02.10.36– Fixed leverage ................................................................. 22
02.10.36.01 - enabling fixed cam control....................................................................................................... 22
02.10.36.10 - Exit for fixed camshaft control............................................................................................................. 22
02.10.36.20 - Entry for fixed cam control.......................................................................................................... 22
02.10.41 - Control EN81-41
02.10.41.01 - Operational enablement EN81-41 ........................................................................................................... 22
02.10.42– Door opener control............................................................................................................... 22
02.10.42.01 - Enable the door opening control operation ...................................................................... 22

5
02.10.42.10 - Exit to open door opening device ............................................................................................ 22
02.10.42.20 - Signal to close door opening device ........................................................................................... 22
02.10.43– Electric lock controls ................................................................................................. 22
02.10.43.10 - Departure for electric lock controls........................................................................................ 23
02.10.43.11 - Keep lock powered with door open........................................................................... 23
02.15 - M MAINTENANCE...................................................................................................................................... 23
02.15.01 - Installation test
02.15.01.01 - Activation of installation test mode
02.15.01.02 - Type of installation test................................................................................................................... 23
02.15.01.03 - Use of doors in installation tests ............................................................................................ 23
02.15.01.04 - Waiting time between test trips................................................................................................. 23
02.15.05 - Limiter Test ......................................................................................................................... 23
02.15.05.01 - Exit for spool 1 of fabrict............................................................................................................. 23
02.15.05.02 - Pulse in the test coil 1................................................................................................................. 23
02.15.05.03 - Exit for the tes coil 2t............................................................................................................. 23
02.15.05.04 - Pulse in test coil 2.................................................................................................................. 24
02.15.05.05 - Exit for coil 3 of teat............................................................................................................. 24
02.15.05.06 - Pulse in coil 3 of test.................................................................................................................. 24
02.20 - P PARAMETERSAADVANCED.......................................................................................................................... 24
02.20.01 - Service Operating Time Limit .......................................................................................... 24
02.20.07 - Type of photocella ........................................................................................................................ 24
02.20.08 - Type of weighing scales...................................................................................................................... 24
02.20.11 - Load cell connection in cabin ................................................................. 24
02.20.15 - Activation of the engine temperature control (PTC) .......................................................... 24
02.20.22 - Ignore the oil temperature overheat signal ................................................................. 24
02.20.23 - Ignore the center error signall ............................................................................................. 24
02.20.30 - Type of maneuvering batteries ..................................................................................................... 24
02.20.31 - Type of cabin batteries .......................................................................................................... 24
02.20.40 - Special configurations.......................................................................................................... 25
02.20.40.01 - 02.20.40.08 CEB 1 until CEB 8.......................................................................................................... 25
02.20.40.41 - 02.20.40.48 CEM 1 until CEM 8 ....................................................................................................... 25
02.20.40.61 - 02.20.40.68 CEIO 1 to CEIO 8....................................................................................................... 25
02:40 - S CABIN SIGNALS.................................................................................................................................... 25
02.40.05 - Entry to keep door open....................................................................................... 25
02.40.34 - Auxiliary Input AP
02.40.35 - Entry for door close button .................................................................................... 25
02.40.36 - Entrance for VIP function ............................................................................................................ 25
02.40.37 - Departure for RAP
02.40.50 - Alarm call disabling signal ............................................................................ 25
02.40.51 - Auxiliary output for cabin light control............................................................................... 25
02.40.54 - Auxiliary exit indication overload .................................................................................. 25
02.40.60 - Departure to CP1 ........................................................................................................................... 25
02.40.61 - Departure for CP2 ........................................................................................................................... 25
02.41 - S Hollow Signs26
02.41.01 - End of travel signal.............................................................................................................. 26
02.50 - C CONNECTIONSVVIRTUALS.............................................................................................................................. 26
02.50.01 - 02.50.32 Cable Virtual 0 until Cable Virtual 31 ...................................................................... 26
02.60 - C CONFIGURATION OFLOG .......................................................................................................................... 26
02.60.01 - Save position pulses in the LOG ......................................................................................... 26
02.60.02 - Save the status of the series in the LOG ....................................................................................... 26
02.75 - A USER MANAGEMENT.................................................................................................................... 26
02.75.01 - User 1 ..................................................................................................................................... 26
02.75.01.01 - PIN number ......................................................................................................................................... 26
02.75.01.02 - Access level .................................................................................................................................... 26
02.75.90 - Administrator.............................................................................................................................. 26
6
02.75.90.01 - PIN number ......................................................................................................................................... 26

03– UTILITIES............................................................................................................................................. 27

03.01 - R EARMAR
03.02 - L CALL TO APLANTA................................................................................................................................... 27
03.50 - F ECHA YHORA27
03.50.01 - Day of the weeka ......................................................................................................................... 27
03.50.02 - Year
03.50.03 - Months.............................................................................................................................................. 27
03.50.04 - Day ............................................................................................................................................... 27
03:50:05 - Hour
03:50:06 - Minuteo.27
03.55 - P PARAMETRIZATION..................................................................................................................................... 27
03.55.01 - Record parameters...................................................................................................................... 28
03.55.10 - Restore factory settings......................................................................................... 28
03.55.90– Access to optional features.............................................................................................. 28
03:55:91– Restartr .28
03.60– HHISTORY OF FAILURES................................................................................................................................ 28
03.60.01– Reset failure history......................................................................................................... 28
03.90 - A UPDATE......................................................................................................................................... 28
03.90.01 - Update Maneuver Firmware ................................................................................................... 28

MANUFACTURER'S NOTE

Carlos Silva SA will not be liable for claims regarding damages or costs arising from the
failure to comply with the instructions in this manual or to use it beyond what is described here.

The information contained in this document may change without prior notice. Except as permitted
Under copyright laws, reproduction, adaptation, or translation is prohibited without a
written permission.

®Carlos Silva is the brand of Carlos Silva S.A.


KDT Evoes product owned by Carlos Silva S.A.

7
01 - Monitor
Allows viewing the status of the elevator

01.01 - State
Allows you to visualize the status of the elevator in real time
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

Substate
Allows you to view the substatus of the elevator in real time.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

01.03 - Out of service reason


Allows you to view the reason for the elevator being out of service in real time
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

01.04 - Machine status


It allows you to view the state of the machine in real time.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

01.05 - Machine Substate


Allows visualizing the substate in which the machine is located in real time
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

01.09 - Position monitor


Allows visualizing the position/location of the elevator in real time
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

01.09.01 - Current plant


Indicate the floor where the elevator is located.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

01.09.02 - Destination plant


Indicate the destination floor of the elevator
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

01.09.05 - Magnetic zone


Indicate the magnetic zone where the elevator is located.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

01.14 - Output Monitor

01.14.01 - Direction instructions


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

01.14.02 - Speed limits


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

01.14.50 - Operator control signal monitor


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

01.15 - Input monitor


Monitor the maneuver entries

01.15.01 - Series Monitor


Monitor the sets of the maneuver
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

8
01.15.02 - Position monitor
Monitor the elevator position
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

01.15.06 - Inspection Signal Monitor


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

01.15.10 - Entrance monitor


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

01.15.10.01 - Adjustment of the entry to monitor


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

01.15.10.02 - Value of the monitored entry


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

01.15.51 - Photocell monitor


It allows you to view the status of the photoelectric cells.
photoelectric cell (2)
ON - Interrupted
OFF - Without interruption
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

01.15.60 - Full and overload monitor


Allows you to visualize the status of the complete and the overload.
left - excess load
ON - with full / with excess load
OFF - without full / without overload
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

01.15.65 - Central input monitor


Show the information supplied by the control center to the operation.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

01.50 - Counter monitor


Monitor the status of the different counters of the maneuver
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

01.50.50 - Total number of maneuvers


Total number of maneuvers performed by this elevator
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

01:50:55 - Travel timer (ms)


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

01.50.70 - Errors CANC(%)


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

01.60 - Historical event log


Inquiry about the latest relevant events of the elevator
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

01.60.01 - 01.60.32 - Event number 1 to Event number 32


Event stored in record 1 until Event stored in record 32
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

01.70 - Hardware Monitor


Allows you to view the status of different hardware elements of the system
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

9
01.70.20 - Cabin CAN
OK - The communication bus with the cabin CPU is correct
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

01.70.40 - BUS SAR


OK - Communication received from the SAR
ERROR - no communication is received from the SAR (it may be because the installation does not have SAR, because not
there is a CAN bus in the cabin or an error in the hardware
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

01.70.90 - micro SD
OK - The micro SD works correctly
ERROR - Cannot access the micro SD (it may be because it is not inserted, because it has a
invalid format or because it is not compatible
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

10
02 - Configuration
Adjustment of the specific parameters of each elevator

02.01 - General Parameters


Basic configuration parameters of the installation

02.01.01 Type of maneuver


Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.01.02 - Upper floor


Adjust this parameter to the number of plants minus one
EXAMPLE: In an 8-story building, this parameter is adjusted to 7.
FACTORY DEFAULT: 1
MIN: 1 MAX: 31 STEP: 1
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.01.04 - Downtime in the plant


Adjust the time the elevator will be stopped on a floor before ordering the doors to close for
serve new calls
FACTORY DEFAULT: 7 s
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.01.06 - Mounting mode


This parameter will be used during the mounting period to prevent the elevator from performing
automatic movements
With the mounting mode activated, the cabin can only be moved during inspection and only if it is not in
inspection will be out of service
0 - Mount mode disabled (normal operation once fully installed)
1 - Mounting mode activated (only moves in inspection)
FACTORY DEFAULT: 1
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.01.08 - Positioning mode


Select the type of elevator positioning.
1 - Standard positioning
2 - Basic positioning (only 1 speed and 2 stops oils)
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.01.11 - Call Acceptance


Define how the action on the call buttons affects the movement of the cabin:
This action on the buttons can be to press and hold or just press.
NO - Press and hold in the cabin and outside
LANDING - Press and hold in the cabin, only press outside
CAR & LANDING - Just press in the cabin and outside
FACTORY DEFAULT: NO
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.02 - Doors
Adjust the parameters related to the door settings

02.02.01 - General parameters


Adjust the door parameters that generally affect all floors
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.02.01.02 - Door closing time limit


Adjust the maximum time that the maneuver allows the closing door order without having closed it.
If this time ends and it has not managed to close it, it will reopen to retry later.
FACTORY DEFAULT: 7 s
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics
11
02.02.01.03 - Attempts to close doors
Adjust the number of times it will try to close the doors before entering the door state.
blocked
FACTORY DEFAULT: 10
MIN: 10 MAX: 20 STEP: 1
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.02.01.04 - Door lockout time


Adjust the maximum allowed time with intercepted maneuver or activated door open button. If
if this time is exceeded, it will enter a locked doors state
FACTORY DEFAULT: 30 s
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.02.01.05 - Door unlocking time


Adjustment of the time that will remain in locked door status
Setting this high time prevents the door operator from malfunctioning due to excessive operations in front of a
failure in the series
FACTORY DEFAULT: 5 min
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.02.01.07 - Attempts of photocell


Adjust the number of times the photocell allows interception before entering door mode.
blocked
FACTORY DEFAULT: 10
MIN: 3 20
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.02.01.08 - Time for door rest


Adjust the time that must elapse before ordering the doors to return to their resting state.
NOTE: The resting state of the doors is selected individually from floor to floor and may be different in each of them.
FACTORY DEFAULT: 30 s
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.02.01.10 - Door synthesis


Activation of messages opening and closing doors in cabin synthesis
0 - Disabled
1 - Activated
FACTORY DEFAULT: 1
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.02.02 - Specific parameters of each plant


Adjust the specific door parameters for each floor
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.02.02.01 - 02.02.02.8 - Control Operator Doors Plant 0 to Control Operator Doors


Plant 7
A - Operator 1 acts (NOT MARKED - does not act)
B - The operator 2 acts (NOT CHECKED - does not act)
C - Door 1 OPEN at rest (UNMARKED - CLOSED at rest)
D - Door 2 OPEN at rest (UNMARKED - CLOSED at rest)
E - Selective Door Opening (UNMARKED - Fixed double boarding)
F - Allows opening two doors at the same time (UNCHECKED - Does not allow opening two doors at the same time)
G - Not used
H - Not used
FACTORY DEFAULT: A - 1 / B - 0 / C - 0 / D - 0 / E - 0 / F - 0 / G - 0 / H - 0
NOTE: 0 - FALSE / 1 - TRUE
Basic Advanced Intermediate Admin Console PC M2CS Cabin Maneuver Electric Hydraulics

02.02.50 - Control entries and exits of operators


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

12
02.02.50.03 - Connection of photocell 1
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.02.50.04 - Connection of phototransistor 2


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.03 - Indications
Adjustment of user indication parameters

02.03.02 - Display
Adjustment of the symbols to be displayed on the screens.
Standard symbols table in displays.
-3 , -2 , -1 , 0 , 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 , 9 , 10 , 11 , 12 , 13 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 ,
24, 1A, 1B, 2A, 2B, 3A, 3B, A, B, BAR, C, CAR, E, G, G1, G2, G3, H, L, LB, LG, M, P, PB, PH
PR , R , RC , RI , RJ , RS , S , S1 , S2 , S3 , SA , SS , T , U , UG , Z

NOTE: For symbols not included in this table, a Display with special sequence is required.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.03.02.01 - 02.03.02.8 Plant Symbol 0 to Plant Symbol 7


Programming of the symbol that appears on the Display from floor 0 of the installation to floor 15
from the installation.

FACTORY DEFAULT Floor 0 0


FACTORY DEFAULT Plant 1 1
FACTORY DEFAULT Plant 2 2
FACTORY DEFAULT Plant 3 3
FACTORY DEFAULT Plant 4 4
FACTORY DEFAULT Plant 5 5
FACTORY DEFAULT Floor 6 6
FACTORY DEFAULT Plant 7 7

Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.03.03 - Acoustics
Adjustment of the cabin synthesis message on each floor
Table with standard voice synthesis in synthesizer.
VOICE ACOUSTICS M21 <Unassigned>
M1 PLANT ONE M22 Unassigned
M2 SECOND FLOOR M23 <Unassigned>
M3 PLANT THREE M24 <Not assigned>
M4 FOURTH FLOOR M25 <Unassigned>
M5 FIVE PLANT M26 <Not assigned>
M6 FLOOR SIX M27 <Unassigned>
M7 PLANT SEVEN M28 <Unassigned>
M8 PLANT EIGHT M29 <Unassigned>
M9 Ninth floor M30 <Unassigned>
M10 PLANT TEN M31 GROUND FLOOR
M11 PLANT ONCE M32 PLANT LESS ONE
M12 SWEET PLANT M33 PLANT LESS TWO
M13 PLANT THIRTEEN M34 PLANT LESS THREE
M14 PLANT FOURTEEN M35 <Unassigned>
M15 <Unassigned> M36 <Unassigned>
M16 <Not assigned> M37 <Unassigned>
M17 <Unassigned>
M38 BASEMENT ONE
M18 Unassigned
M39 BASEMENT TWO
M19 <Not assigned>
M40 BASEMENT THREE
M20 <Unassigned>
M41 <Unassigned>

13
M42 <Unassigned> M58 <Unassigned>
M43 Unassigned M60 PLANT ZERO
M44 <Unassigned> M61 PARKING
M45 <Unassigned> M63 RESTAURANT
M46 <Unassigned> M66 <Unassigned>
M47 <Unassigned> M67 Unassigned
M48 Unassigned M68 <Unassigned>
M49 <Unassigned> M74 <Not assigned>
M50 ATTIIC M75 <Unassigned>
M51 SOBREATICAL M79 GARAGE
M52 GROUND FLOOR M80 BASEMENT
M53 PRINCIPAL M81 RESTAURANT
M54 Mezzanine M82 <Unassigned>
M55 Principal
NOTE: For synthesis messages not included in this table, a synthesizer with special sequence is required.
Basic Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.03.03.01 - 02.03.03.8 Synthesis Plant 0 to Synthesis Plant 7


Synthesis programming that will be broadcast in each plant
FACTORY DEFAULT Plant 0 M60
FACTORY DEFAULT Plant 1 M1
FACTORY DEFAULT Plant 2 M2
FACTORY DEFAULT Plant 3 M3
FACTORY DEFAULT Plant 4 M4
FACTORY DEFAULT Plant 5 M5
FACTORY DEFAULT Plant 6 M6
FACTORY DEFAULT Plant 7 M7

Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.03.08 - Type of indication on external buttons


Define the indication in the registration of the exterior buttons between:
0 - Indicates occupied
1 - Indicates call log and positional
2 - Indicates call log and is
3 - Indicates call log
4 - Indicates occupied and is
FACTORY DEFAULT: 0
Basic Interim Advanced Administrator Console PC M2CS Maneuver Cabin Hydraulic Electric

02.03.09 - Positional indication on cabin push buttons


0 - No position indication on the cockpit control panel
1 - With positional indication on the control panel of the cabin
FACTORY DEFAULT: 1
Basic Intermediate Advanced Administrator Console PC M2CS Maneuver Cabin Hydraulic Electric

02.03.13–TFT 2.8 cabin


Basic Intermediate Advanced Administrator Console PC M2CS Maneuver Cabin Hydraulic Electric

02.03.13.01–Brillo
Basic Intermediate Advanced Administrator Console PC M2CS Maneuver Cabin Hydraulic Electric

02.03.13.10–Background color
Basic Intermediate Advanced Administrator Console PC M2CS Maneuver Cabin Hydraulic Electric

02.03.13.11–Font color
Basic Intermediate Advanced Administrator Console PC M2CS Maneuver Cabin Hydraulic Electric

14
02.03.13.20–Direction
Basic Intermediate Advanced Administrator Console PC M2CS Maneuver Cabin Hydraulic Electric

02.03.14–TFT 2.8 exterior


Basic Intermediate Advanced Administrator Console PC M2CS Maneuver Cabin Hydraulic Electric

02.03.14.01–Brightness
Basic Intermediate Advanced Administrator Console PC M2CS Maneuver Cabin Hydraulic Electric

02.03.14.10–Background color
Basic Intermediate Advanced Administrator Console PC M2CS Maneuver Cabin Hydraulic Electric

02.03.14.11–Font color
Basic Intermediate Advanced Administrator Console PC M2CS Maneuver Cabin Hydraulic Electric

02.03.14.20–Address
Basic Intermediate Advanced Administrator Console PC M2CS Maneuver Cabin Hydraulic Electric

02.03.15 - TFT 7 and 10


Basic Intermediate Advanced Administrator Console PC M2CS Maneuver Cabin Hydraulic Electric

02.03.15.01 - Theme
1 - Vertical with multimedia
2 - Vertical with weather information*
3 - Horizontal with left positioning and multimedia
4 - Horizontal with position on the left and weather information*
5 - Horizontal with positional to the right and multimedia
6 - Horizontal with position to the right and weather information*
For weather information, the screen requires an Internet connection.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.03.15.02 - Logo
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.03.15.03 - Configuration
A - Show date and time
B - Show weather information*
C, D, E, F, G, H - Not used*
For weather information, the screen requires an internet connection.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.03.15.04–Font color
A - Value of red
B - Value of green
C - Value of blue
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.03.15.05–Background color
A - Value of red
B - value of green
C - Value of blue
D - Opacity (0 transparent - 10 Opaque)
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.03.15.10–02.03.15.14–Text1 to Text5
Basic Advanced Intermediate AdminConsole PC M2CS Cabin Maneuver Electric Hydraulic

02.03.15.20–Announcement text
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

15
02.03.15.21–Duration of the announcement
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.03.15.50–Volume adjustment
A - Volume of the voice synthesis
B - Multimedia Volume
C - Volume of the gong
NOTE: All volumes range from 0 (MUTE) to 10 (MAX)
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.03.15.51–Voice synthesis configuration


Single synthesis (0) or synthesis in two languages (1)
B - Language of the first synthesis
C - Language of the second synthesis
B - Language of the texts on screen
Basic Advanced Intermediate Admin Console PC M2CS Cabin Maneuver Electric Hydraulics

02.03.15.90–Reset to factory values


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.03.89 - Floor indication


Basic Intermediate Advanced Administrator Console PC M2CS Maneuver Cabin Hydraulic Electric

02.04 - Returns and automatic maneuvers


Return adjustments and automatic maneuvers

02.04.01 - Returns
Adjustment of parameters related to the automatic returns of the cabin
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.04.01.01 - Return Activation


Activate the plant return
0 - Disabled
1 - Activated
NOTE: When activated (parameter set to 1) it will return from any floor to the return floor when the return time elapses.
FACTORY DEFAULT: 0
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.04.01.02 - Return plant


Adjust the floor that the cabin will return to if there is any return activated.
FACTORY DEFAULT: 0 MIN: 0 MAX: 31 STEP: 1
Basic Intermediate Advanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.04.01.03 - Time for return


Adjust the time it will take for the cabin to return to the return station once it has stopped.
rest
NOTE: Adjust 0 s so that it returns automatically after the stop time
FACTORY DEFAULT: 1 min
Basic Advanced Intermediate Admin Console PC M2CS Cabin Maneuver Electric Hydraulics

02.04.03 - Parked
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectrics

02.04.03.01 - Entrance for parking 1


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.04.03.02 - Parking plant 1


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.04.03.50 - Park with closed doors


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

16
02.05 - Tractor group parameters
Adjustment of the specific parameters of the control type
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.05.50 - Engine Configuration


Adjustment of the motor control parameters
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Hydraulic Electric

02.05.50.01 - Direct start or E-T selection


Adjust the engine starting type
0 - Star-delta start
1 - Direct start
Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02.05.50.10 - Star Time


Star time adjustment
Basic Advanced Intermediate Admin Console PC M2CS Cabin Maneuver HydraulicElectrics

02.05.60 - Engine disconnection delay


Time that elapses from when the speed commands and the motor are disconnected for (soft stop)
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02.05.65 - Delay of instructions after engine


Time that elapses from when the motor is connected until the speed setpoint appears.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectrics

02.05.71 - Slow start time


Allows the maneuver to start at low speed for a specified period of time.
Set NO to start directly in fast mode
FACTORY DEFAULT: 2
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Hydraulic Electric

02.05.72 - Locking valve


Control of the locking valve operation
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02.05.72.01 - Exit for lock valve control


Output to activate the lock valve
FACTORY DEFAULT: NoUSE
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02.05.72.05 - Valve locking time at startup


Adjust the behavior of the locking valve:
OFF - Works only when going down
TRAVEL - It works on ascent and descent
0.5 - 2.5 - The time adjusted to the start of the trip works
FACTORY DEFAULT: TRAVEL
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02.05.80 - Safety valve test


If necessary, allow enabling an automatic and periodic tightness test of the valve.
safety (also called pilot valve or UCM valve)
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Hydraulic Electric

02.05.81 - Braking margin time


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Hydraulic Electric

17
02.06 - Low consumption
Adjustment of parameters related to low consumption
02.06.01 - Cabin light
Adjustment of parameters that allow for savings in cabin light consumption
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Hydraulic Electric

02.06.01.01 - Cabin light time


Time to turn off the cabin light after the doors enter standby mode.
NOTE: Set NO so that the cabin light never turns off, 0 s for it to turn off immediately after the doors pass.
rest state or other desired value
FACTORY DEFAULT: 5 min
Basic Advanced Intermediate Admin Console PC M2CS Cabin Maneuver Electric Hydraulics

02.06.03 - Time for low consumption displays


Time to switch the displays to low consumption mode after the doors transition to the state of
rest
NOTE: Set NO so that they never switch to low consumption, 0 s so that they switch immediately after the doors change state
of rest or another desired value
FACTORY DEFAULT: NO
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.07 - Rescues
Adjustment of the parameters related to the different available automatic rescues

02.07. 10 - Type of rescue


Adjust the type of rescue
No rescue
1 -Automatic at reduced speed to lower plant
2 - Automatic by brake release with pulse train
FACTORY DEFAULT: 0
Basic Advanced Intermediate Administrator Console PC M2CS Cabin Maneuver HydraulicElectric

02.07. 20 - Automatic rescue due to decompensation


Through this rescue, in the event of a power supply failure, the control will safely maneuver the cabin.
to the nearest floor and then it will open both doors to allow for evacuation.
This rescue is carried out due to decompensation, so it is not possible to choose the plant in which.
will evict.
NOTE: In order for this operation to be available, an accessory is required to enable automatic rescue due to imbalance and define
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectrical

02.07.20.01 - Departure for automatic rescue control


It allows defining an output in the maneuver to control the automatic rescue due to decompensation.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectrical

02.07.45 - Oil rescue


Adjustment of parameters related to the rescue in the oils
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02.07.45.02 - Perform rescue automatically


In the event of a power failure, the rescue will be carried out automatically or not.
0 - It will not be automatic, it will be done when making a call
1 - It will be carried out automatically to the immediate lower plant
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Hydraulic Electric

02.07.50 - Departure for the rescue control


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02.07.51 - Allow upward rescue in VF


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

18
02.08–Restrictions
It allows restricting the use of the elevator if necessary.

02.08.40 - Entry to disable the upload


Entry to disable upward trips
Closed contact allows upward travel
Open contact, does NOT allow uphill travel
FACTORY DEFAULT: NoUSE
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.10 - Specific operating procedures of the installation


Adjustment of the parameters of a specific operation of the installation
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.10.01 - Evacuation Control in case of fire (EN81-73)


Adjustment of the operational parameters EN81-73
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.10.01.01 - EN81-73 Operation


Select whether the elevator must have EN81-73 operation or not.
0 - It should not have EN81-73 operational.
1 - If it must have EN81-73 operational
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Hydraulic Electrical

02.10.01.02 - Main evacuation plant


Define the floor where the cabin will evacuate in case of detecting the main evacuation alarm (EN81-
73)
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02.10.01.03 - Door to open in the main evacuation floor


Define the door that will open when the cabin goes to the main evacuation floor as a consequence
from a main alarm
1 - It will open door 1
2 - It will open door 2
1 and 2 - It will open the two doors (A and B of the door configuration on that floor have to be
marked)
NOTE: It is possible to have a regular door in a building, but during an evacuation, another one can be opened. To do this, it must be defined.
plant as selective double loading (A, B and E marked)
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02.10.01.04 - Main alarm signal


Define where the main fire alarm signal of EN81-73 is connected.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02.10.01.06 - Alternative evacuation plant


Define the floor where the cabin will evacuate in case of detecting an alternative evacuation alarm (EN81-
73).
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

19
02.10.01.07 - Door to open in alternative evacuation floor
Define the door that will open when the cabin goes to the alternative evacuation floor as
consequence of an alternative alarm
1 - It will open door 1
2 - It will open door 2
1 and 2 - It will open the two doors (A and B of the door configuration of that floor need to be
marked)
NOTE: It is possible to ensure that in a building the usual door is one, but in an evacuation another one opens. To achieve this, it must be defined.
plant as selective double dispatch (A, B, and E marked).
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Hydraulic Electric

02.10.01.08 - Alternative alarm signal


Define where the alternative fire alarm signal for EN81-73 is connected.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02.10.01.20 - Close doors in evacuation plant


It allows you to select whether at the evacuation plant it will park with doors open or closed.
0 - with open doors
1 - with closed doors
Basic Advanced Intermediate Admin Console PC M2CS Cabin Maneuver HydraulicElectric

02.10.11 - Control of the brake monitor contacts (A3)


Adjustment of the control parameters for the brake monitor contacts
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.10.11.01 - Control of brake monitor contacts (A3)


Adjustment of the control parameters of the brake monitor contacts
Basic Advanced Intermediate Administrator Console PC M2CS Cabin Maneuver Electric Hydraulic

02.10.11.02 - Brake monitor control signal (1 of 2)


Define where the signal that informs Hydra Crono that brake body 1 is connected.
open
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.10.11.03 - Brake monitor control signal (2 of 2)


Define where the signal is connected that informs Hidra Crono that brake body 2 is.
open
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.10.15 - Automatic entry control in inspection


Adjustment of automatic input control parameters in inspection
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.10.15.01 - Enabling automatic entry in inspection


Enable automatic input operation in inspection. (When a sensor located on the ceiling of
the cabin detects access, the maneuver enters inspection even if the box selector is on
NORMAL
If this operation is enabled, in order to exit inspection, it is necessary to grant permission either from a
entry in the maneuver or from a command in the console/PC (connected in maneuver)
0 - No automatic entry in inspection
1 - Automatic entry into inspection upon detecting access to cabin roof
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.10.15.02 - Access hole detection signal


Entry used to detect access to the gap
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

20
02.10.15.03 - Permit signal to leave inspection
Entry used to allow the maneuver to exit inspection
NOTE: Only act if the maneuver is in NORMAL and with closed series.
Basic Advanced Intermediate Admin Console PC M2CS Cabin Maneuver Electric Hydraulic

02.10.15.04 - Permission to leave for inspection


Allows exit from inspection.
NOTE: Only act if the maneuver is in NORMAL and with the series closed.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.10.15.10 - Exit for commissioning after inspection


It allows generating a pulse in the coils that enable commissioning after inspection.
(EN81-21)
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.10.15.90 - Type of access gap detection contact


Selection of the type of contact for access hole detection
0 - Open contact that closes upon detecting access to gap
1 - Closed contact that opens when access is detected
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.10.33 - Anti-drift device control


Control of an electric anti-drift device
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.10.33.01 - Activation of the anti-drift device operation


0 - Without antiderivative
1 - With antiderivative
FACTORY DEFAULT: 0
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.10.33.10 - Exit to extend counter-drift


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.10.33.11 - Departure to pick up anti-drifting


Basic Advanced Intermediate Admin Console PC M2CS Cabin Maneuver Electric Hydraulic

02.10.33.30 - Control entry for anti-drift off


Closed contact indicates complete backflow out
FACTORY DEFAULT: NoUSE
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.10.33.31 - Collection of anti-drift control entry


Closed contact indicates completely retracted antideriva.
FACTORY DEFAULT: NoUSE
Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.10.33.50 - Cable de-tensioning time


Upon reaching the floor, it maintains a slow descent order for the selected time to release the cables of
traction
FACTORY DEFAULT: 0
Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

21
02.10.33.55 - Time for anti-sagging operation
In the adjusted time, the maneuver will make an upward movement to prevent the cables from
loosen and get out of the pulley
NOTE: adjust NO so that it does not perform this function
FACTORY DEFAULT: NO
Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.10.35–Photoelectric barrier test


Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.10.35.01 - Enable photoelectric barrier test


Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.10.35.10 - Departure to take the test


Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.10.35.20 - Entry 1 for barrier test


Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.10.35.21 - Entry 2 for barrier test


Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

Fixed lever
Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.10.36.01 - enabling of fixed cam control


Basic IntermediateAdvanced Admin Console PC M2CS Cabin Maneuver Electric Hydraulics

02.10.36.10 - Exit for fixed camshaft control


Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.10.36.20 - Entry for fixed lever control


Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.10.41 - Control EN81-41


Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.10.41.01 - Operational enablement EN81-41


Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.10.42–Door opener control


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.10.42.01 - Enabling the operation of door opening control


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.10.42.10 - Departure to open door opening device


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.10.42.20 - Signal to close door opening device


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.10.43–Control of electric locks


Allows you to define an output to control electric locks
Basic Advanced Intermediate Administrator Console PC M2CS Cabin Maneuver Electric Hydraulic

22
02.10.43.10 - Departure for control of electric locks
Basic Advanced Intermediate Admin Console PC M2CS Cabin Maneuver Electric Hydraulics

02.10.43.11 - Keep the lock powered with the door open


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectrical

02.15 - Maintenance
Allows maintenance operations of the elevator

02.15.01 - Installation test


Adjustment of parameters related to installation test mode
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.15.01.01 - Activation of installation test mode


Activate the installation test mode. This mode allows to subject the entire elevator to a series of
stress tests
0 - Installation test mode disabled
1 - Installation test mode activated
NOTE: While in test mode, it remains in public service. If you are making a test trip and a call is generated, it will abort the
test trip and the call will serve
Once it rests, it will return to test mode.
FACTORY DEFAULT: 0
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.15.01.02 - Installation test type


Selection between the two different types of installation test mode
0 - Test between random plants
1 - End-to-end test
FACTORY DEFAULT: 0
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.15.01.03 - Use of doors in installation tests


Select whether you want the doors to open as a result of a test call.
0 - It will not open the doors
1 - If it will open the doors
NOTE: the doors that will open in each case will always depend on the door configuration of the floor where it has stopped.
FACTORY DEFAULT: 1
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.15.01.04 - Waiting time between test trips


Adjust the time between test trips
NOTE: Set 0s so that it does not wait between test trips
ATTENTION!!! Adjust this time high enough so that it never exceeds the maximum number of connections/hour of the machine.
FACTORY DEFAULT: 0 s
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.15.05 - Limiter Test


It allows generating a pulse in the triggering coils of the speed limiter. It can support
limiters with up to three trigger coils
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.15.05.01 - Output for test coil 1


Select the output where the trigger coil 1 of the limiter is connected.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.15.05.02 - Pulse in test coil 1


Generate a 1-second pulse on the output for coil 1
Basic Advanced Intermediate Console Administrator PC M2CS Maneuver Cabin Electric Hydraulic

02.15.05.03 - Output for test coil 2


Select the output where the trigger coil 2 of the limiter is connected.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric
23
02.15.05.04 - Pulse in test coil 2
Generate a 1-second pulse on the output for coil 2.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02.15.05.05 - Exit for test coil 3


Select the output where the triggering coil 3 of the limiter is connected.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02.15.05.06 - Pulse in test coil 3


Generate a 1-second pulse on the output for coil 3.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02.20 - Advanced Parameters


Advanced parameter adjustment

02.20.01 - Service Operating Time Limit


The maximum operating time in service is the maximum allowed running time without detecting any
change in position signals
If this time expires, the elevator will go out of service permanently, from which it will only come out by
manual rearm
FACTORY DEFAULT: 45 s
Basic IntermediateAdvanced Administrator Console PC M2CS Cabin Maneuver Electric Hydraulic

02.20.07 - Type of photocell


Selection of the type of photocell
0 - (NC) without interrupting, there is tension at the entrance
1 - (NO) without interruption, there is NO tension at the input
FACTORY DEFAULT: 0
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.20.08 - Type of fish load


Selection of the type of weighing scale
0 - (NC) without excess load, there is tension at the input
1 - (NO) without excess load, there is no tension at the input
FACTORY DEFAULT: 0
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.20.11 - Load cell connection in cabin


Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.20.15 - Activation of the engine temperature control (PTC)


Activate or deactivate the engine temperature sensor (PTC)
0 - Disabled
1 - Activated
FACTORY DEFAULT: 1
Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.20.22 - Ignore the oil temperature high signal


Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.20.23 - Ignore the central error signal


Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.20.30 - Type of maneuvering batteries


Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.20.31 - Cabin battery types


Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics
24
02.20.40 - Special configurations
Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.20.40.01 - 02.20.40.08 CEB 1 to CEB 8


Basic IntermediateAdvanced Administrator Console PC M2CS Cabin Maneuver Electric Hydraulics

02.20.40.41 - 02.20.40.48 CEM 1 to CEM 8


Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.20.40.61 - 02.20.40.68 CEIO 1 to CEIO 8


Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.40 - Cabin signals


Allows configuring the available cabin signals in the cabin roof interface

02.40.05 - Entrance to keep door open


When this entry is activated, it will keep the cabin door open.
It has the same function as the cabin door open button.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectrical

02.40.34 - Auxiliary input AP


Define an auxiliary input for a second door open button.
This input works in parallel with the cabin control panel.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectrics

02.40.35 - Entrance for door closing button


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Hydraulic Electric

02.40.36 - Entrance for VIP function


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02:40:37 - Departure for RAP


Define an output for acoustic indication of accepted call in the cabin.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Hydraulic Electric

02.40.50 - Alarm call disable signal


Signal used to inhibit the alarm button and prevent emergency calls from being made.
when the elevator is functioning correctly.
When the elevator does not allow calls, this exit will be active.
NOTE: It is not necessary to define it if the maneuver is equipped with SAR equipment.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02.40.51 - Auxiliary output for cabin light control


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02.40.54 - Auxiliary output indication overload


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02.40.60 - Departure for CP1


Define an output for the signal to close door 1
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02.40.61 - Departure for CP2


Define an output for the door closing signal 2
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

25
02.41 - Gap signals

02.41.01 - End of travel signal


Report the maneuver that has gone over the race.
NOTE: THIS SIGNAL IS NOT THE SERIES. It is an additional contact at the end of the stroke that will indicate to the maneuver that it has exceeded the stroke if
this happens
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver HydraulicElectric

02.50 - Virtual Connections


Adjustment of virtual connections

02.50.01 - 02.50.32 Virtual Cable 0 to Virtual Cable 31


Establish the correspondence between an input and an output. A virtual cable is defined when
assign an input to an output.
NOTE: Consult the maneuver documentation for details on the available inputs and outputs in Hidra Crono.
FACTORY DEFAULT: INPUT - NoUSE / OUTPUT–NoUSE
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.60 - Log Configuration


Adjust parameters related to the information stored in the LOG

02.60.01 - Save position pulses in the LOG


With this parameter set to 1, the position pulses are saved in the LOG.
This is useful for locating errors in the detection system, but it increases the file size.
generated
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.60.02 - Save series state in the LOG


Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.75 - User Management


Allows managing access to the settings menu for up to 5 different users

02.75.01 - User 1
Adjustment of user access 1
Basic Advanced Intermediate Administrator Console PC M2CS Cabin Maneuver Electric Hydraulic

02.75.01.01 - PIN Number


Adjust the PIN of user 1
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

02.75.01.02 - Access level


Adjust user 1's access level to:
No access
Basic: Basic access
Intermediate: Intermediate access
Advanced: Advanced access
FACTORY DEFAULT: Basic
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

02.75.90 - Administrator
Administrator access adjustment
Basic Advanced Intermediate Administrator Console PC M2CS Cabin Maneuver Electric Hydraulics

02.75.90.01 - PIN number


Adjust the administrator PIN
Basic Advanced Intermediate Admin Console PC M2CS Cabin Maneuver Electric Hydraulics

26
03-Utilities
Allows performing elevator maintenance operations

03.01 - Rearm
Allows reassembling the elevator in case of permanent out of service
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

03.02 - Call to Plant


Make a cabin call to the selected plant
FACTORY DEFAULT: 0
MIN: 0 MAX: 31 STEP: 1
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

03:50 - Date and Time


Allows adjusting the maneuver clock to register events with the correct time
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

03.50.01 - Day of the week


Adjustment of the day of the week
Sunday
Monday
Tue - Tuesday
Wed - Wednesday
Thursday
Friday
Sat - Saturday
FACTORY DEFAULT: Sun
Basic Advanced Intermediate Console Administrator PC M2CS Maneuver Cabin Electric Hydraulic

03.50.02 - Year
Year adjustment
FACTORY DEFAULT: 12 MIN: 12 MAX: 99 STEP: 1
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

03.50.03 - Month
Month adjustment
FACTORY DEFAULT: 1 MIN: 1 MAX: 12 STEP: 1
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

03.50.04 - Day
Adjustment of the day
FACTORY DEFAULT: 1 MIN: 1 MAX: 31 STEP: 1
Basic Advanced Intermediate Console Administrator PC M2CS ManeuverCabin Electric Hydraulics

03:50:05 - Time
Time adjustment
FACTORY DEFAULT: 0 MIN: 0 MAX: 23 STEP: 1
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

03:50:06 - Minute
Minute adjustment
FACTORY DEFAULT: 0 MIN: 0 59
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

03.55 - Parameterization
Allows performing operations related to the elevator parameterization
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

27
03.55.01 - Record parameters
Record the parameterization in the memory of the maneuver.
NOTE: Changes to the unsaved parameters will be lost if the power supply is interrupted.
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

03.55.10 - Restore factory settings


Restore all the settings to factory values.
NOTE: To restore factory settings, the maneuver must be stopped and the safety devices must be open.
Basic Advanced Intermediate Console Administrator PC M2CS ManeuverCabin Electric Hydraulics

03.55.90–Access to optional features


Allows access to optional maneuver functions.
FACTORY DEFAULT: A - 1 / B - 0 / C - 0 / D - 0 / E - 0 / F - 0 / G - 0 / H - 0
Basic IntermediateAdvanced Console Administrator PC M2CS Cabin Maneuver Electrical Hydraulic

03.55.91–Restart
Basic IntermediateAdvanced AdminConsole PC M2CS Cabin Maneuver Electric Hydraulics

03.60–Failure history
Utilities related to the history of failures
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulic

03.60.01–Reset fault history


Allows you to delete the 32 records of the failure history
Basic Advanced Intermediate Console Administrator PC M2CS Cabin Maneuver Electric Hydraulics

03.90 - Update
Allows performing operations related to the elevator firmware update
Basic IntermediateAdvanced Console Administrator PC M2CSCabin Maneuver Electric Hydraulic

03.90.01 - Update Maneuver Firmware


Allows updating the maneuver firmware.
In order to update it, a microSD card with a single firmware file in the root is required.
It is only possible to update if the elevator has the safety series open.
ATTENTION: This operation must be carried out only by authorized personnel and at their own risk.
Basic Advanced Intermediate Console Administrator PC M2CSCabinManeuver Electric Hydraulics

28
NOTES

29
NOTES

30
31
www.carlos-silva.com

Electronic Solutions and Systems for Elevator Control

Salvador Albert i Riera 3, 08339 Vilassar de Dalt, Barcelona, SPAIN


(41° 30' 51" N / 2° 22' 12" E)
+34 937541980
www.carlos-silva.com
[email protected]