Counter Weight @ Deadman Foundation Rebar Inspection Report
Site Code: PH410207
Region: IV-
Site Address: PUROK PAUNLARIN, BRGY. CALATEGAS, B
NARRA, PALAWAN
Counter Weight @ Deadman Foundation Rebar Inspection Report
Work Control Record
This is to certify that the reinforcement works has been supervised and conducted
as per project specifications and in accordance with local codes and standards.
Date : September 27 , 2025 Rebar Supplier: Twin’s D Construction
Supply
Structure : Deadman Foundation
Line and Grade : NGL Excavation (Depth) : 200mm
Footing Dimension(L,W,H): 600 x 2500 x Pedestal Dimension(L,W,H): N/A
2500mm
Diameter Installation
Top Bar : 12mm Top Bar : 12mm
Bottom Bar : 12mm Bottom Bar : 12mm
Stirrups / Lateral Ties : N/A Stirrups / Lateral Ties : N/A
Vertical Bar : N/A Vertical Bar : N/A
Quantity Spacing
Top Bar : 128 pcs Top Bar : spcd @ 150mm o c
Bottom Bar : 128 pcs Bottom Bar : spcd @ 150mm o c
Stirrups / Lateral Ties : N/A Stirrups / Lateral Ties : N/A
Vertical Bar : N/A Vertical Bar : N/A
Chair Bar : 12mm Def. Bar
Marking Legend :
Formworks 2 x 2
P - Passed :
NP – Not Passed Anchor Bolts : N/A
Setting Plate : N/A
Tie wires : #16 GI Tie Wires
Concrete Cover: Bottom: 75mm
Sides: 75mm
Top: 75mm
Remarks :
FTAP Tower Foundation Rebar
Inspection Report Page 1 of
4
Counter Weight @ Deadman Foundation Rebar Inspection Report
Site Code: PH410207
Region: IV-
Site Address: PUROK PAUNLARIN, BRGY. CALATEGAS, B
NARRA, PALAWAN
PHOTOGRAPHS
Reinforcement
Setting
FTAP Tower Foundation Rebar
Inspection Report Page 2 of
4
Counter Weight @ Deadman Foundation Rebar Inspection Report
Site Code: PH410207
Region: IV-
Site Address: PUROK PAUNLARIN, BRGY. CALATEGAS, B
NARRA, PALAWAN
Concrete Cover Foundation Base Concrete Cover Foundation @ sides
Concrete Cover @ Top
CONTRACTOR REPRESENTATIVE FTAP REPRESENTATIVE
Name : TYRONE PATRICK T. MORANTE Name : RAUL M CENIZA
Signature : Signature :
Date : 9/27/2025 Date : 9/27/2025
FTAP Tower Foundation Rebar
Inspection Report Page 3 of
4
Counter Weight @ Deadman Foundation Rebar Inspection Report
Site Code: PH410207
Region: IV-
Site Address: PUROK PAUNLARIN, BRGY. CALATEGAS, B
NARRA, PALAWAN
FTAP Tower Foundation Rebar
Inspection Report Page 4 of