SKF @ptitude Analyst is an advanced software solution designed for enterprise-wide asset condition monitoring and management, offering scalable and customizable features for data analysis and reporting. It supports various data collection methods and integrates with other enterprise systems, facilitating efficient communication and decision-making across departments. The software includes robust diagnostic tools, alarm management, and user-defined access controls, making it suitable for both novice and experienced users.

Uploaded by

Fabio Bringa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
16 views12 pages

CM-P8 10299-3 EN SKF Aptitude Analyst Brochure

SKF @ptitude Analyst is an advanced software solution designed for enterprise-wide asset condition monitoring and management, offering scalable and customizable features for data analysis and reporting. It supports various data collection methods and integrates with other enterprise systems, facilitating efficient communication and decision-making across departments. The software includes robust diagnostic tools, alarm management, and user-defined access controls, making it suitable for both novice and experienced users.

Uploaded by

Fabio Bringa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

SKF @ptitude Analyst

Intelligent and scalable software for


enterprise-wide communications
A core platform from the SKF @ptitude Monitoring Suite of reliability software applications

SKF @ptitude Analyst is a comprehensive Computerized


Enterprise
software solution with powerful diagnostic resource Maintenance
Management
planning
and analytical capabilities. SKF @ptitude SKF @ptitude
System

Analyst provides fast, efficient and reliable decision support

storage, analysis, and retrieval of complex


asset information and makes the informa-
tion accessible throughout your organiza- On-line Periodic
tion. SKF @ptitude Analyst easily scales to surveillance/
protection
vibration/
process data
your specific needs, whether it is operator
inspection rounds, condition monitoring
data collection or in-depth vibration analysis
and expert advice.
SKF @ptitude Analyst
• One software program to manage asset
condition data from portable and on-line
devices SKF @ptitude Analyst allows your opera-
• Easy for novice or experienced users to tions, maintenance and reliability staff to
learn and use view data from different sources using the
• Interconnectivity with multiple enter- same application and communicate infor-
prise-wide software programs and sys- mation to other departments in a customiz-
tems able format.
• Scalable and flexible to meet your unique SKF @ptitude Analyst integrates the SKF
needs Microlog, SKF Microlog Inspector, SKF MAR-
–– Start with one of three base models LIN, and SKF Multilog data collection device
and expand functionality according to ranges into one enterprise-wide software
your needs platform.
–– Easy personalization for individual It can also incorporate data from other
users sources, such as OPC servers, and seam-
–– Application add-ons extend core func- lessly interface with your organization’s
tionality without migration to other Computerized Maintenance Management
base models System (CMMS), Enterprise Resource Plan-
–– User access control to support func- ning (ERP) or other information manage-
tional roles and department needs ment systems. In this way, SKF @ptitude
–– User programmable functions compute Analyst’s integrated platform forms the hub
your company’s KPIs (Key Performance to share information, foster teamwork, and
Indicators) facilitate consistent and reliable decision-
• Supports Oracle and Microsoft SQL Serv- making across functional departments.
er database managers
• Compliance reporting and scheduling
direct tasks and workforce
• Built-in Human Machine Interface (HMI)
Organization and overview
Detailed information – quency, or other selections. SKF @ptitude
efficiently organized Analyst allows you to determine the appro-
priate limits for alarm conditions and how
Screen displays such as data plot layout, alarms are categorized to ensure you
color, size and position can be personalized receive consistent, reliable data in the for-
and automatically updated. A customizable mat that suits you best.
toolbar provides quick access to your most
frequenctly used program features.
Right click on your data plot to modify Automatically schedule
settings and machine information. Scrolling reports to save time
across a data plot, displays data values in
the plot window. The Scheduler Wizard enables you to auto-
matically schedule a specific action, such as
generating a report upon completion of a
Asset data customized for data collection upload, archiving measure-
your unique needs ment data at a specified time or other
event-based actions. This capability helps to
With this powerful analysis tools, you are in eliminate human error and allows you to
complete control – from the way you set up focus on other pressing issues.
hierarchy, filtered workspaces, routes, and Using SKF @ptitude Analyst throughout
analysis parameters, to the customized for- your organization allows collaboration and
mat for reporting. You can collect informa- communication without losing control of
tion based on location, machine type, fre- your data.

2
Connectivity
Staying connected is easy with SKF @ptitude SKF @ptitude Analyst also supports OPC, or OLE for Process Con-
Analyst trol, the most widely-used plant data exchange format. With the
OPC client interface for SKF @ptitude Analyst, common machinery
Today’s data collector systems must support a great variety of data information, such as load, speed, energy usage, and other important
connection methods. SKF @ptitude Analyst supports data collector process data, can be obtained and stored in the database for side by
connections through the USB. For remote users in a Wide Area Net- side analysis.
work or users with low bandwidth connection, the Thin Client Trans- XML (Extensible Markup Language), is an open data format sup-
fer application may be used to provide a remote but direct access to ported by SKF @ptitude Analyst. Using this format, a flexible data
the database. In addition, this supporting application also permits stream can be set up for automatic import or exports of selected
completely disconnected data collectors to transfer route and vibra- data types. XML data can be imported in Excel or other software
tion data using an email file attachment. with little programming, hence making SKF @ptitude Analyst a truly
On-line systems with USB, RS484 or Ethernet connections are open system.
supported and can be routed through gateways and firewalls. Serv-
ices dedicated to each monitoring device or monitoring chain ensure
data collection with a high throughput and thus quick live updates.

Remote CMMS
Monitoring Lubrication

Process
Inspection
Control Condition
and Safety
Monitoring

3
Diagnosis and analysis
Robust analytical and diagnostic capabilities
that are easy to use
SKF @ptitude Analyst continues to deliver class leading functionality
by incorporating innovations such as derived functions, CTA (Cyclic
Time Average) overlay, and HAL (Harmonic Activity Locator) analysis
to its users (CTA and HAL are SKF patented algorithms).
SKF @ptitude Analyst supports many standard graphs and com-
bination graphs that quickly visualize problem areas. Graph overlays
provide cursor functions to obtain special information such as fre-
quency band details, average and standard deviation values, skew or
kurtosis. Frequency analysis overlays can be used for spectrum
graphs to quickly identify common bearing or other fault source fre-
quencies. Implementation of HAL provides harmonic series recogni-
tion whereby impact failures are recognized and prioritized by likeli- The CTA overlay enhances time waveform analysis when diagnosing
hood. broken gear teeth.
In some cases, the actual stream of information is not directly
acquired but rather must be computed based on a combination of
acquired values. Therefore, SKF @ptitude Analyst supports Derived
Points, which act like virtual data collection points computed by a
user programmable macro that operates on any other data stream. Enhanced alarm view saves valuable time
For example, you may calculate potential savings from air leaks in a Alarm View window displays all points that require immediate atten-
compressed air system by implementing a derived calculation that tion to help you quickly identify and prioritize follow-up activities and
multiplies the severity of a measurable air leak in a pipe by the cost acknowledge alarm conditions. The Alarm Details window offers a
to generate each unit. comprehensive list of the specific points in alarm and the level and
type of alarm, all in one convenient view.
Auto Linking makes it easy to view individual alarms as data plots
Automated features simplify configuring and and alarm details change automatically when you select new points,
fine- tuning alarms saving time and simplifying the analysis process.

Since similar machines often use similar alarms, the Alarm Data-
base provides user-defined alarms that can be applied to create Versatile viewing options for multi-parameter
alarm settings for multiple measurement points. analysis
An Alarm Wizard assists in creating Statistical Alarms to set
alarms for your most important machinery with minimal research For fast, easy comparison of two or more readings across multiple
and effort. SKF @ptitude Analyst considers historical data and natu- points, SKF @ptitude Analyst allows you to select a measurement
ral variation in machinery vibration levels and generates reliable and drag and drop it into the plot, providing convenience and saving
alarm criteria tailored to the specific machine. time.
SKF @ptitude Analyst’s variable speed alarming features accom- The SKF @ptitude Analyst frequency analysis feature helps to
modate normal fluctuations in machine speed and function. Alarm identify specific bearing and gearbox frequency sets for rapid detec-
limits are automatically reset as speed changes, preventing false tion and correction of probable bearing and machine problems. SKF
alarms. @ptitude Analyst’s on-line data view automatically refreshes to dis-
SKF @ptitude Analyst also supports overdue alarms that notify play the latest information, point status and alarm details. Live views
you if monitoring data was not collected as expected. provide immediate update of displayed data while the Event Log
documents specific occurrences over time. The System Information
view provides one-stop navigation between different views, such as
Event Log, On-line Data view, individual routes and workspaces.
SKF @ptitude Analyst’s database management tools allow you to
closely track machine problems to recreate events for predictive
maintenance and to perform root cause failure analysis.

4
Scalability through application add-ons
Feature and deployment scalability
SKF @ptitude Analyst software is configured using license keys.
These keys automatically activate or add new functionality to the
base application, hence the name “add-on”. Additionally, three differ-
ent base applications are available: SKF @ptitude Inspector primarily
used for Operator Driven Reliability (ODR), SKF @ptitude Analyst for
SKF Microlog Analyzer, and SKF @ptitude Analyst, the flagship appli-
cation of the SKF @ptitude Monitoring Suite.
The SKF @ptitude Analyst software can be deployed as a stand
alone application on a single workstation or as a fully networked,
distributed application whereby data storage and business logic is
kept on separate application servers to help ensure high speed and
availability.
SKF @ptitude Analyst software fully supports virtualization
through environments such as Citrix or Microsoft Windows Server Orbit graph with synchronized X, Y channel time waveforms.
2008. These environments allow SKF @ptitude Analyst to be
installed and published onto an enterprise system from a centralized
location. Data connections can be made through the virtualization
environment or through Thin Client Transfer, which provides fast and
secure network connectivity.
Analysis and Reporting Module (ARM)
SKF @ptitude Analyst features embedded ARM functionality to
Transient analysis (Run up Coast down) upload, view and post-process field data from the following models
The Transient Manager is a standard add-on to the SKF @ptitude of the SKF Microlog Analyzer AX / GX, SKF Microlog Advisor Pro and
Analyst that allows you to manage and display all transient hierarchy SKF Microlog Consultant application modules: Run up Coast down,
views. Depending on transient view properties, the transient event FRF, Analyzer, Non-route, Balancing, Bump, Data Recorder, and
may be automatically captured at defined speed changes and other Check-to-Conformance. The field data can then be linked to hierar-
parameters to provide accurate analysis, such as a turbine coast chy nodes for future referencing or archiving.
down event. Transient events may be displayed in live or trend (his-
torical) mode using the following graphs:

• The Topology graph illustrates a series of spectra (similar to


Campbell plots) using a user-defined color scheme to easily visu-
alize amplitude peaks. This graph also features vector compensa-
tion.
• The Bode graph with Damping Cursor is a dual plot consisting of
phase and amplitude as a function of rotational speed. The damp-
ing cursor enables you to identify resonance information at critical
speed when performing transient event analysis.
• The Nyquist graph plots the shaft’s movement during a transient
event and is similar to a Bode graph but using polar notation. This
graph also features vector compensation and optional rotational
speed labels.
• The Cascade graph plots data over running speed and features
data filtering options for optimal event presentation. Analysis and Reporting Module transfer function – Frequency Response
Function (FRF) plot.

5
Operator Driven Reliability
Operator Driven Reliability (ODR), the framework for organizing an
operator’s activities, is key to an organization’s reliability program.
Being in close proximity to the machines 24 hours a day, 7 days a
week, operators are often the first to notice even the smallest
changes in machine condition.
To help you develop your ODR programme, SKF offers Mainte-
nance Strategy Review services that will evaluate your facility and
systems, determine asset criticality, and formulate a maintenance
strategy. Using the SKF Asset Management Support Tool (AMST),
SKF can analyze your plant’s dominant failure modes and the signifi-
cant effect of those failures. AMST can then further recommend
inspections and assign job tasks and actions for optimal asset effi-
ciency. Once a maintenance strategy review has been performed
using AMST, the data can be directly transferred to SKF @ptitude
Inspector software and used to create your plant’s asset hierarchy
and operator inspection rounds. SKF Machine Condition Detector
SKF @ptitude Inspector is the SKF @ptitude Analyst software SKF @ptitude Inspector fully supports the SKF Microlog Inspector,
specifically targeted for ODR use. SKF @ptitude Inspector and the SKF MARLIN’s, Machine Condition Detector as well as the Wireless
SKF Microlog Inspector, the next generation of hand held Windows Machine Condition Detector POINT type (velocity, acceleration envel-
Mobile based portable computer inspection system, or SKF MARLIN oping, and temperature). All process data types are supported
system enable operations personnel to make their rounds, collecting including: pressure, flow, RPM, temperature, and AC or DC current.
machine condition, inspection and process data easily and efficiently Instantly access points in alarm or view alarm status for a specific
in the palm-sized unit. Data is trended, and when certain conditions machine. An Alarm Wizard helps calculate alarms for plant machin-
are met, the SKF MARLIN system alerts the operator, then provides ery, making this complex task almost effortless for the user.
instructions for immediate corrective action.
• The Wireless Machine Condition Detector supports acquisition of
Fast Fourier Transfer (FFT) data for the Acceleration Enveloping
Software tailored to the needs of the (gE) and Velocity measurements. SKF @ptitude Inspector uploads
SKF Microlog Inspector and SKF and displays these dynamic data types effortlessly.
MARLIN user
SKF @ptitude Inspector incorporates a simple user interface to
speed up system implementation.

• Easily create and modify databases in a hierarchical form, define


data collection points and types, create routes and then download
to the SKF MARLIN data manager or automatically syncs with the
SKF Microlog Inspector.
• Compliance reporting and scheduling allows a range of collection
schedules that vary from day, week, month, day of year, and mul-
tiple or repeat collections per time period. Reports identify missed
or overdue collection points or data collection that is out of com-
pliance parameters.
• A variety of user specified views includes multi-pane plots, win- SKF Microlog Inspector I-Pro SKF Microlog Inspector S-Pro
dow sizes and positions, a customizable tool bar and more to help
optimize user productivity and efficiency.
• Standardized notes can be used to document observed machin-
ery and process conditions, then combined with machine data and
images to create a variety of reports.

SKF Machine
SKF Wireless Machine Condition Detector
Condition Detector

6
Access and security
SKF @ptitude Analyst permits access on a
customized basis, yet allows the effective
exchange of detailed information across
functional departments.

Advanced security system


protects data
SKF @ptitude Analyst enables security
through the use of security roles. A security
role is comprised of many individual security
levels that control access rights to data,
viewing, reporting, graphing, and more.
Assigning users a security role instantly
defines the access rights for that user.
Changing the security role definition updates
the access rights for all assigned users; this
is a time-savings feature when managing
several users. SKF @ptitude Analyst comes Personalized access rights allow the software administrator to protect against errors and enable
with four default roles, however an unlim- traceability.
ited number of roles can be defined.

Setup data change log


Measurement setup greatly defines how
effective the entire system monitors your
assets. For audit purposes, SKF @ptitude
Analyst provides a log of changes made to
the most important measurement setup
details, logging date, responsible person and
change detail.

Customized reports
Extensive report customization features let
you control the specific kinds of machine
information to be communicated throughout
the organization. You can customize the
templates or design an entirely new report
including data plots, supplemental informa- Predefined report templates make it easy to generate common reports such as Last Measurement,
tion and digital images. Additionally, the Exception, Overdue/Noncompliant, History, Route Statistics, and others.
Report Manager allows you to maintain a
history of reports, and pre-configure report
content and format to share with selected
users.
Reports are generated in HTML format,
giving you the flexibility to view on-screen,
print, edit using Microsoft Word or Excel,
attach to an email or automatically post to
your company’s intranet when programmed
into the Scheduler feature.

7
Features and capabilities
Features / capabilities SKF @ptitude SKF @ptitude SKF @ptitude Features / capabilities SKF @ptitude SKF @ptitude SKF @ptitude
Inspector Analyst for Analyst Inspector Analyst for Analyst
CMSW 7200 SKF Microlog CMSW 7400 CMSW 7200 SKF Microlog CMSW 7400
(t) Analyzer (n) (t) Analyzer (n)
CMSW 7300 CMSW 7300

( ) •
( )

Device support Alarms

• SKF Microlog Inspector


with Wireless machine
t n • Overall alarm levels
–– Danger high, alert high,
t • n
condition detector (WMCD) alert low, danger low
• SKF MARLIN with Machine t n –– Level alarm, out of
condition detector (MCD) window, in window
or Wireless machine


condition detector (WMCD) Alarm types

••
• SKF Microlog (AX series, n
GX series, CMVA 65 or • Overall forecast t n


CMVA 60) • Overall percent change t n
• SKF Multilog (DMx, IMx, n • Unlimited spectral band n

••
CMU, TMU or LMU) (overall and peak)
• Wireless WMx, Wireless n • Spectral envelope n


V/T • Phase angle n
• Overall t n
Human Machine Interface • Inspection t n
(HMI) • Machine condition t n
detector
• Integrated HMI n • Variable speed alarms n
• Crash alarm (CMU, TMU n
Diagnostics only)


• BOV alarming n
• Spectrum n • Statistical alarm t n
–– Harmonic Activity Index (HAI). A spectrum post processor showing the calculation
likelihood of harmonic patterns being present
–– Spectrum plot keyboard shortcuts Graph displays

••
• Time waveform n
–– Time domain statistics • Trend t n

••
including standard • Spectrum t n
deviation, skew, • Time domain n
kurtosis, and crest • Waterfall n
factor • Cascade n
• Analysis and Reporting n • Topology n
Module • Orbit n
• Transient analysis n • Shaft centerline n
–– Transient event views • Bode n


–– Vector compensation • Nyquist n
–– Live and trend mode graphs • Combination graphs n
–– Damping cursor –– Trend / spectrum
–– Trend / spectrum / time waveform
Alarms –– Trend / speed
–– Trend / speed / spectrum
• Advanced functions n –– Trend / speed / spectrum / time
including high level –– Trend / speed / time
analysis functions such as –– Waterfall / extracted trend / spectrum
CTA, HAL, Contribution, –– Trend / time waveform


Statistical functions, etc. –– Spectrum / band trend
• View alarm status t n –– Bode / Nyquist
indicators directly at the –– Speed / bode / orbit / spectrum


hierarchy –– Speed / bode / spectrum
• Alarm window t n • Live views / live bars (SKF n

••
–– Acknowledge alarms and enter comments or recommendations Multilog)
–– Quickly find and identify all points in alarm within the hierarchy, group, route, • Multiple hierarchy support t n


workspace, or machine • Transient analysis graphs n
• Alarm details t n


–– Provides a summary of the type of alarms and status
• User defined alarm levels t n
–– Public alarms that can be shared with other users
–– Private alarms that can only be used by specific users
–– Unlimited number of alarms can be configured

8
Features / capabilities SKF @ptitude SKF @ptitude SKF @ptitude Features / capabilities SKF @ptitude SKF @ptitude SKF @ptitude
Inspector Analyst for Analyst Inspector Analyst for Analyst
CMSW 7200 SKF Microlog CMSW 7400 CMSW 7200 SKF Microlog CMSW 7400
(t) Analyzer (n) (t) Analyzer (n)
CMSW 7300 CMSW 7300

( ) •
( )

Graph display overlays General

• Trend
–– Single cursor t •• n
• Multiple languages
available
t • n

••
–– Notes indicators t n –– Standard languages: English, French, German, Portuguese, Spanish,
–– Statistical trend line n Swedish

• •
–– Exponential curve line t n –– Non-standard languages: Russian, Simplified Chinese
–– Curve fit t n • True multi-processing t n

••
• Spectrum operating environment
–– Single cursor t n allowing simultaneous
–– Harmonic cursor with t n background and


Set Speed function foreground processing.
–– Sideband cursor with n Consistent with Microsoft


dB and Delta values Windows functions:
–– Band cursor n –– “Right-click” functionality
–– Peak cursor n –– Drag and drop
–– Frequency analysis n –– Cut / copy / paste


cursor –– Context sensitive help
–– Diagnostics cursor n • Allows for complete t n
–– Spectral band alarm, n integration of third party


spectral envelope alarm applications

••
• Time waveform • User preferences to allow t n


–– Single cursor n customization
–– Band cursor n • Complete user and t n
–– Band cursor with n installation manuals on

•• •
statistics installation DVD
–– CTA overlay n • Product Support Plans t n


–– Frequency analysis n (PSP) available
cursor • Optional interfaces t n
available:
Display tools –– OPC Client

• •
–– CMMS (contact SKF Sales Representative for details)
• Graph linking t n • Measurement archiving t n
–– Display information area • DAD services system – t n
–– On-screen text annotation down e-mail alerts
–– Percent of full scale setting
–– Auto scaling Measurement types


–– Spectrum cursor micro-manipulation

••
–– Date range setting • Acceleration, Velocity, n

••
• Baseline spectrum storage n Displacement
• Waterfall spacing (time / n • Amps, Volts (AC or DC) n


date) based or event • Acceleration Enveloping t n
• On-screen integration / n (gE)
differentiation • Machine condition t n
detector (MCD) Velocity,
Storage, file formats and networking Acceleration Enveloping,

•• •
Temperature
• Oracle support t n • Temperature (Celsius and n
• Microsoft SQL Server t n Fahrenheit)

• •
support • Flow (GPM, LPM) t n
• Binary importing and t n • High Frequency Detection n


exporting (.MAB) (HFD, DHFD)
• XML importing and n • Inspection (User definable) t n


exporting • Operating hours t n
• Supports for LAN and t n • Operating time (Elapsed n


WAN and accumulative) (SKF
• Support for Thin Client t n Multilog)

• ••
(Terminal) environments • Pressure (PSI and Bars) t n
• Operates with Citrix, t n • SEE n
Terminal Server, and • Machine speed t n
Microsoft Windows 2008


application server
• Unlimited number of: t n
–– Hierarchies
–– Collection points
–– Measurements
–– Workspaces

9
Features / capabilities SKF @ptitude SKF @ptitude SKF @ptitude Features / capabilities SKF @ptitude SKF @ptitude SKF @ptitude
Inspector Analyst for Analyst Inspector Analyst for Analyst
CMSW 7200 SKF Microlog CMSW 7400 CMSW 7200 SKF Microlog CMSW 7400
(t) Analyzer (n) (t) Analyzer (n)
CMSW 7300 CMSW 7300

( ) •
( )

Measurement attributes Reporting

• Conditional POINTs t n • Report templates allow t • n


–– SKF Microlog Inspector, SKF MARLIN only quick and easy report
• Control POINTs n configuration for use and
–– SKF Microlog Analyzer reuse

• •
–– SKF Multilogs IMx, CMU, LMU, TMU
• Support for Multi-Point n • Alarm acknowledgment t n

••
Automation (MPA) comments / notes
• English or metric units t n
• Triax sensor support n Security and stability


–– SKF Microlog Analyzer


–– SKF Multilogs CMU, LMU, IMx • Supports definition of user t n


• Multi-channel support n profiles / roles
–– SKF Microlog Analyzer AX series, GX series version 2.0 (or higher) • Unlimited number of user t n

• •
–– SKF Multilogs DMx, IMx profiles / roles
• Derived POINT t n • Fully configurable user t n
–– User definable mathematical formula to calculate values from data collected rights that allow you to
on one or more POINTs. read, view, and have full


• Alternative time zone n access
support for on-line devices • Access rights can be t n


located across a wide area restricted to specific
• Display and storage of t n hierarchy or allow multiple


non-collection events hierarchy access
–– SKF Multilog IMx • Point setup change log. t n
–– SKF Microlog Inspector Maintains a log of what
was changed by whom
Reporting and when. Preference


setting determines if a
• Preserved reports t n reason message is


–– Enables you to maintain a history of reports required before allowed to


• Shared reports t n make setup changes.


–– Allows you to share and preconfigure reports for selected users • Communication with on- t n
• Send reports to screen, t n line devices is supported


HTML file, printer by Windows services.
• HTML file can be posted to t n Multiple services may be


internet, intranet, emailed used to provide a high
• HTML files can be opened t n degree of security. Service


and modified further using requires no user login.
Microsoft Office products, • Communication services t n
such as Word, Excel, are auto-restarted in case


PowerPoint of failures
• Customizable report t n


content Templates and wizards


• Data plots, supplemental t n
information, and digital • Statistical alarm wizards t n
images can be included in use historical data to help

• •
reports refine overall alarms
• Report template types: t n • Hierarchy template wizard t n
–– Blank allows for rapid hierarchy
–– Last measurement creation and machine


–– Exception templates for reuse
–– Overdue / noncompliant • Report template allows for t n
–– Pending overdue / noncompliant the custom configuration
–– Collection status of reports and report
–– Route history / route statistics templates for reuse and


–– Set statistics sharing
–– Upload statistics • Scheduler wizard helps t n
–– History configure and preset
–– Inspection recurring activities such as
–– Work notification report generation, data
–– User defined archival and task
–– Compliance reminders

10
Hardware requirements
Stand alone configuration Network configuration – Database server
• Running SKF @ptitude Analyst / SKF @ptitude Inspector • Running Oracle or Microsoft SQL Server database management system
• Running Oracle or Microsoft SQL Server database management system • Storing data
• Storing data
Network configuration for up to 35 Clients and one database. Installations of
Configuration Minimum requirements Recommended requirements 50 Clients or greater will require an on-site assessment by our Field Service
Engineers.
Operating system Windows 7 OR Windows 7 OR
(Note 1) Windows XP Professional Windows XP Professional Configuration Minimum requirements Recommended requirements
with Service Pack 2+ with Service Pack 2+
Processor (Note 2) Intel 1.0 GHz, 32 or 64-bit, Intel Core 2 Duo, 2.0 GHz, Operating system Windows 2008 Server Windows 2008 Server
or better 32 or 64-bit, or better Processor (Note 2) Intel 2.0 GHz, 32 or 64-bit, Intel Core 2 Duo, 3.0 GHz,
RAM 2.0 GB 4.0 GB or more or better 32 or 64-bit, or better
Disk space available 1.2 GB 1.2 GB or more RAM 2.0 GB 4.0 GB or more
for standalone Quantity of hard 3 5
computer (Note 3) drives (Note 4)
DVD drive One (1) required One (1) required Disk space available 1.2 GB 1.2 GB or more
Oracle / Microsoft Version 10g, 11g / SQL Version 10g, 11g / SQL (Note 3)
SQL Server (Note 5) Server 2008 R2, 2008 Server 2008 R2, 2008 DVD drive One (1) required One (1) required
Oracle / Microsoft Version 10g, 11g / SQL Version 10g, 11g / SQL
SQL Server (Note 5) Server 2008 R2, 2008 Server 2008 R2, 2008

USB port for SKF Microlog / SKF Microlog Inspector / SKF MARLIN transfer
and serial port for SKF Multilog IMx configuration.

Network configuration – Network Client Network configuration – Application server


• Running SKF @ptitude Analyst / SKF @ptitude Inspector • Running SKF @ptitude Analyst / SKF @ptitude Inspector
• Running database client software
Network configuration for up to 35 Clients and one database. Installations of
Network configuration for up to 35 Clients and one database. Installations of 50 Clients or greater will require an on-site assessment by our Field Service
50 Clients or greater will require an on-site assessment by our Field Service Engineers.
Engineers.
Configuration Minimum requirements Recommended requirements
Configuration Minimum requirements Recommended requirements
Operating system Windows 7 OR Windows 7 OR
Operating system Windows 7 OR Windows 7 OR (Note 1) Windows 2008 Server Windows 2008 Server
(Note 1) Windows XP Professional Windows XP Professional Processor Intel 1.0 GHz, 32 or 64-bit, Intel Core 2 Duo, 3.0 GHz,
with Service Pack 2+ with Service Pack 2+ or better 32 or 64-bit, or better
Processor (Note 2) Intel 1.0 GHz, 32 or 64-bit, Intel Core 2 Duo, 2.0 GHz RAM 2.0 GB 4.0 GB or more
or better 32 or 64-bit, or better Disk space available 1.2 GB 1.2 GB or more
RAM 2.0 GB 4.0 GB or more DVD drive One (1) required One (1) required
Disk space available 1.0 GB 1.0 GB or more
for each network
client
DVD drive One (1) required One (1) required
Oracle / Microsoft Version 10g, 11g / SQL Version 10g, 11g / SQL
SQL Client (Note 5) Server 2008 R2, 2008 Server 2008 R2, 2008

USB port for SKF Microlog / SKF Microlog Inspector / SKF MARLIN transfer
and serial port for SKF Multilog IMx configuration.

Note 1 Note 4
Windows 7 (32 or 64-bit) Professional or Ultimate Editions (please visit the Windows 7 The major benefits of spreading Oracle across three or more hard disks at the server is
and UAC compatibility matrix in skf.com/cm the improved speed, and improved recoverability of a previously archived database. The
[www.skf.com/portal/skf/home/products?contentId=892828&lang=en]), recommended five disk configuration provides the optimal protection for backup, recov-
Microsoft.NET Framework 3.5, 4.0, Windows 4.5 Installer and Windows Mobile Device ery, indexing, and speed. Disk / file configuration should ONLY be handled by a SKF Field
Center 6.1. Service Technician certified on SKF @ptitude Analyst. If using RAID, the combination of
RAID 0 and RAID 1 is recommended over RAID 5.
Note 2
These requirements apply to SKF @ptitude Analyst complete with database manage- Note 5
ment system. Other applications running simultaneously may degrade performance. Oracle 10g Express Edition is supported under Windows XP 32-bit only. In a Network
Hyper-threading should be disabled in some systems. Client configuration you must install Oracle 32-bit Client Software. If using Windows 7
(32 or 64-bit), then Oracle 11g must be installed.
Note 3
These requirements ONLY apply to SKF @ptitude Analyst complete with database man- Notice
agement system. Additional storage disk space is required for data. If running other system configurations, please contact your local SKF Representative to
inquire about compatibility.

11
Ordering information Product Support Plans
• SKF @ptitude Analyst software for SKF Microlog Analyzer, SKF SKF is committed to providing the highest degree of customer sup-
Microlog Inspector, SKF MARLIN, SKF Multilog Systems (DMx, port in the industry. Product Support Plans (PSP) extend the stand-
WMx, IMx, TMU, CMU, LMU), MIM, and Wireless Monitoring Sys- ard product warranty for an additional length of time to continue
tem V/T [CMSW 7400] your unlimited access to Technical Support, global repair coverage
• SKF @ptitude Analyst for SKF Microlog Analyzer [CMSW 7300] and more.
• SKF @ptitude Inspector [CMSW 7200]

All models are available in Single and Multi-client configurations. Protect your investment
Please contact your local SKF Reliability Systems representative for Product Support Plans help to make sure that your equipment is
Multi-client model information. maintained to the highest standards. Condition monitoring products
are an investment, and a Product Support Plan is a great way to
protect your investment for years.
Installation and training
Installation and training is available through your local SKF Supplier Greater peace of mind
or Representative. • Firmware and / or software upgrades keep your products advanc-
ing with current industry standards*
• Unlimited technical support from knowledgeable professionals
can save you time and frustration by quickly resolving problems
• Data accuracy with unlimited calibrations that comply with ISO
standards
• Loaner equipment supplied when your product is brought in for
service*
• Hassle-free repairs. We’ve got you covered with parts, labor and
shipping.

Premier product support plans also include a full SKF @ptitude


Exchange subscription. SKF @ptitude Exchange is SKF’s knowledge
portal, complete with white papers, articles, interactive services,
tutorials and more – available 24 hours a day to help build your
staff’s asset maintenance and reliability expertise.

* Provided with Premier PSP coverage.

Please contact:
SKF USA Inc.
Condition Monitoring Center – San Diego
5271 Viewridge Court · San Diego, California 92123 USA
Tel: +1 858-496-3400 · Fax: +1 858 496-3531
Web: www.skf.com/cm

® SKF, @PTITUDE, MARLIN , MICROLOG, and MULTILOG are registered trademarks of the SKF Group.
Oracle is a registered trademark of Oracle Corporation.
Microsoft, Windows, PowerPoint, Excel and SQL Server are either registered trademarks or trademarks of Microsoft Corporation in the
United States and/or other countries.
Intel is a registered trademark of Intel Corporation.
All other trademarks are the property of their respective owners.
© SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-
sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
SKF Patents include: #US04768380 · #US05679900 · #US05845230 · #US05854553 · #US05992237 · #US06006164 ·
#US06199422 · #US06202491 · #US06275781 · #US06489884 · #US06513386 · #US06633822 · #US6,789,025 ·
#US6,792,360 · US 5,633,811 · US 5,870,699 · #WO_03_048714A1

PUB CM/P8 10299/5 EN · July 2011

skf.com

You might also like