0% found this document useful (0 votes)
485 views5 pages

Mix Design

The document outlines the assumed standard deviation values for various grades of concrete as per IS 10262:2019, indicating that M10 and M15 have a standard deviation of 3.5 N/mm2, while M65 and above have a standard deviation of 6.0 N/mm2. It also provides water content requirements per cubic meter of concrete based on the nominal maximum size of coarse aggregate, with specific values for aggregates of sizes 10 mm, 20 mm, and 40 mm. Additionally, it notes that these values are contingent upon proper site control and may require adjustments based on actual conditions.

Uploaded by

Anupam Suwar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
485 views5 pages

Mix Design

The document outlines the assumed standard deviation values for various grades of concrete as per IS 10262:2019, indicating that M10 and M15 have a standard deviation of 3.5 N/mm2, while M65 and above have a standard deviation of 6.0 N/mm2. It also provides water content requirements per cubic meter of concrete based on the nominal maximum size of coarse aggregate, with specific values for aggregates of sizes 10 mm, 20 mm, and 40 mm. Additionally, it notes that these values are contingent upon proper site control and may require adjustments based on actual conditions.

Uploaded by

Anupam Suwar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Table 2; IS 10262:2019 (Assumed Standard Deviation)

Assumed Standard Deviation,


SI No. Grade of Concrete
N/mm2
(1) (2)
(3)
i. M10, M15 3.5
ii. M20, M25 4.0
iii. M30, M35, M40, M45, M50, M55, M60 5.0
iv. M65, M70, M75, M80 6.0
NOTES
1. The above values correspond to good degree of site control having proper storage of cement; weigh batching
of all materials; controlled addition of water; regular checking of all materials; aggregate grading and
moisture content; and regular checking of workability and strength. Where there are deviations from the
above, the site control shall be designated as fair and the values given in the above table shall be increased
by 1 N/mm2.
2. For grades M65 and above, the standard deviation may also be established by actual trials based on assumed
proportions, before finalizing the mix.

Table 4; IS 10262:2019 (Water Content per Cubic Metre of Concrete For Nominal Maximum Size of Coarse
Aggregate)

SI No. Nominal Maximum Size of Aggregate, mm Water Content 1), Kg


(1) (2) (3)
i. 10 208
ii. 20 186
iii. 40 165
1)
Water Content Corresponding to saturated Surface dry aggregate.
NOTES
1. These quantities of mixing water are for use in computing cement/cementitious materials content for trial
batches..
2. On account of long distances over which concrete needs to be carried from batching plant/RMC plant, the
concrete mix is generally designed for a higher slump initially than the slump required at the time of
placing. The initial slump value shall depend on the distance of transport and loss of slump with time.

Table 3; IS 10262:2019 (Approximate Air Content)


Table 5; IS 10262:2019 (Volume of Coarse Aggregate per unit Volume of Total Aggregate for Different Zones of
Fine Aggregate for Water-Cement/Water-Cementitious Material Ratio of 0.5)

You might also like