0% found this document useful (0 votes)
51 views11 pages

Technical Data Sheet For 2520V-2520VQ PVV Hydraulics Vane Pump

The document provides detailed specifications and installation guidelines for SV Series Paddle and Vane Pumps, including model codes, flow codes, and connection types. It outlines recommended hydraulic oil types, installation practices, and maintenance procedures, emphasizing the importance of proper alignment and sealing to prevent operational issues. Additionally, it includes information on cartridge kits for easy replacement and maintenance of the pumps.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
51 views11 pages

Technical Data Sheet For 2520V-2520VQ PVV Hydraulics Vane Pump

The document provides detailed specifications and installation guidelines for SV Series Paddle and Vane Pumps, including model codes, flow codes, and connection types. It outlines recommended hydraulic oil types, installation practices, and maintenance procedures, emphasizing the importance of proper alignment and sealing to prevent operational issues. Additionally, it includes information on cartridge kits for easy replacement and maintenance of the pumps.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

SV Series Paddle Pumps SV Series Vane Pumps

Double Pump - Model Codes Double Pump - Model Code

(F3-) S3525V 38A21 -1 AA 22 R

(F3-) ****V ** A ** (F) -** * 22 *

Designation Connections No.


Flow Code Flow Code Type Axis Exit positions Rotation
Series Port design

Series Port Design


Flow code Flow code Shaft type Outlet positions Rotation
designation connections No.
Omit 10, 12, 14 2, 3, 4 Viewed from the side cover
if I don't know 15, 17, 19 5, 6, 7 Viewed from cover end Visa
2520V
requires 21, 25 8, 9, 10 Assembly since

Omit 11, 12, 14 Mounting A - opposite entrance the axis

if not 2, 3, 4

required 21, 25, 30 5, 6, 7 B- 90° SAH from the entrance Viewed from
3520V
32, 35, 38 8, 9, 10 Omit shaft end
11, 12, 14 if I don't know -1 C- online with input of pump
35, 42, 45 2, 3, 4 requires Key handle
F3- 50, 57, 60 Brida 5, 6, 7 Omit strkey D- 90° SH from the entrance
4520V
Together 66, 75 SAE 8, 9, 10 if not R-SH
Vitón 11, 12, 14 required -86 (I turn to
22
10, 12, 14 Key. Chaveta rights)
F3- 21, 25, 30 SAE 15, 17, 19 Reinforced R-CW
3525V
Viton 32, 35, 38 Flange 21, 25 Hdstrkey A- opposite inlet port
Seals
35, 42, 45 10, 12, 14 F- -11 B- 90° CCW from inlet L-SAH
50, 57, 60 15, 17, 19 Assembly Striped (Turn to
4525V
66, 75 21, 25 with foot Spline C- inline with inlet left
F- L-CCW
35, 42, 45 Foot D- 90° CW from inlet
50, 57, 60 21, 25, 30 mounting
4535V
66, 75 32, 35, 38

7
SV Series Paddle Pumps SV Series Vane Pumps

7.Exit positions Outlet positions

Entry

Exit No. 1

Exit No. 2

Side view cover Viewed from cover end of pump

Ports departure positions All series except S4535V


S4535V
Outlet port positions All series except S4535V
Exit No. 2 at 135° SAH from the entrance Exit No. 2 opposite the entrance
AA
No. 2 outlet 135° CCW from inlet No. 2 outlet opposite inlet
Exit No. 2 at 45° SAH from the entrance Exit No. 2 at 90° SAH from the entrance
AB
Exit No. 1 opposite the entrance No. 2 outlet 45° CCW from inlet No. 2 outlet 90° CCW from inlet
No. 1 outlet opposite to inlet Exit No. 2 at 45° SH from the entrance Exit No. 2 in line with the entrance
AC
No. 2 outlet 45° CW from inlet No. 2 outlet inline with inlet
Exit No. 2 at 135° SH from the entrance Exit No. 2 at 90° SH from the entrance
AD
No. 2 outlet 135° CW from inlet No. 2 outlet 90° CW from inlet
Exit No. 2 at 135° SAH from the entrance Exit No. 2 opposite to the entrance
BA
No. 2 outlet 135° CCW from inlet No. 2 outlet opposite inlet
Exit No. 2 at 45° SAH from the entrance Exit No. 2 at 90° SAH from the entrance
BB
Exit No. 1 at 90° SAH from the entrance No. 2 outlet 45° CCW from inlet No. 2 outlet 90° CCW from inlet
No. 1 outlet 90° CCW from inlet Exit No. 2 at 45° SH from the entrance Exit No. 2 in line with the entrance
BC
No. 2 outlet 45° CW from inlet No. 2 outlet inline with inlet
Exit No. 2 at 135° SH from the entrance Exit No. 2 at 90° SH from the entrance
BD
No. 2 outlet 135° CW from inlet No. 2 outlet 90° CW from inlet
Exit No. 2 at 135° SAH from the entrance Exit No. 2 opposite the entrance
CA
No. 2 outlet 135° CCW from inlet No. 2 outlet opposite inlet
Exit No. 2 at 45° SAH from the entrance Exit No. 2 at 90° SAH from the entrance
CB
Exit No. 1 in line with the entrance No. 2 outlet 45° CCW from inlet No. 2 outlet 90° CCW from inlet
No. 1 outlet inline with inlet Output No. 2 at 45° SH from the entrance Exit No. 2 in line with the entrance
CC
No. 2 outlet 45° CW from inlet No. 2 outlet inline with inlet
Exit No. 2 at 135° SH from the entrance Exit No. 2 at 90° SH from the entrance
CD
No. 2 outlet 135° CW from inlet No. 2 outlet 90° CW from inlet
Exit No. 2 at 135° SAH from the entrance Exit No. 2 opposite to the entrance
YES
No. 2 outlet 135° CCW from inlet No. 2 outlet opposite inlet
Exit No. 2 at 45° SAH from the entrance Exit No. 2 at 90° SAH from the entrance
DB
Exit No. 1 at 90° South of the entrance No. 2 outlet 45° CCW from inlet No. 2 outlet 90° CCW from inlet
No. 1 outlet 90° CW from inlet Exit No. 2 at 45° SH from the entrance Exit No. 2 online with the entrance
DC
No. 2 outlet 45° clockwise from inlet No. 2 outlet inline with inlet
Exit No. 2 at 135° SH from the entrance Exit No. 2 at 90° SH from the entrance
DD
No. 2 outlet 135° CW from inlet No. 2 outlet 90° CW from inlet

8.Design number Design number


9.Rotation (seen from the axis at the end of the pump) Rotation (viewed from shaft end of pump)
R-SH, Right turn for clockwise direction, omit CW Right hand for clockwise, omit
L-SAH, left turn for counterclockwise direction CCW Left hand for counterclockwise

8
SV Series Paddle Pumps SV Series Vane Pumps

S2520V

See optional axes

Entry Ø63.5 Output No.1 Ø25.4

Exit No.2 Ø19.1

Optional Axes Optional Shafts Cylindrical shaft with keyway Straight key shaft type
Modelo Código Eje F(key)longchave
A B C ØD E
Model Shaft code F(key)widthxlength
1 59 9.53 11.1 22.23/22.20 24.5/24.4 4.75x32
S2520V
86 78 9.53 11.1 25.37/25.35 28.3/28.1 6.36x50.8

Optional Axes Optional Shafts Serrated axle type Splined shaft type
Striated Data Table Spline data table

Code No. Diameter Diameter Diameter


Model Step
Axis A B C D ØE teeth Mayor Primitive Minor

Shaft Number Major Form Minor


Model Pitch
code of teeth diameter diameter diameter

S2520V 11 44.5 9.53 11.1 --- 27.8 13 16/32 22.17/22.15 19.03 18.63/18.35

9
SV Series Pallet Pumps SV Series Vane Pumps

Cartridge Kit Series SV SV Series Cartridge Kits

(F3)-PC-S25V-21-10 R
(F3-) PC S**V ** 10 *
Marking Kit Cartridge Designation Series Flow Code Design number Rotation
Cartridge kit mark Series designation Flow code Design number Rotation

PC-kit pump cartridge 2, 3, 4, 5, 6, 7, 8 Seen from the axis


S20V
simple and double, side axis 9, 10, 11, 12, 14
Omit if not Viewed from shaft
is required PC-cartridge kit of single 10, 12, 14, 15 end of pump
S25V
Omit if not required pump and doublepump shaft end 17, 19, 21, 25
10
PCT-kit double pump cartridge, 21, 25, 30 R- counterclockwise SH
S35V
F3-Vitón joint side cover 32, 35, 38 Anti-clockwise turn SAH
F3-Viton seal PCT-cartridge kit of double pump, 35, 42, 45, 50 R- CW
S45V
cover end 57, 60, 66, 75 L- CCW

Series M Council N (O-ring)


ØA B C ØD E ØF ØG H K
Series M Gasket N (O-ring)
S20V 82.5 81.5 70.1 47 61.5 4.8 76.2 7 73.6 82.76x72.26x3.5 40x3.5
S25V 96.8 98.8 87 52.2 71.2 4.8 90.5 7 88.19 97x91x3.5 44x3.5
S35V 114.3 117.7 105 72.2 90.3 6.4 108 7 103.94 114.5x108.5x3.5 63.09x3.53
S45V 133.35 141.1 129.6 80.2 105.5 6.4 127 8 123.8 133.6x127.6x3.5 71x3.55

19
Installation and Application Installation and Application
Hoses for Pump Inlet and Outlet Flange for Inlet and Outlet of Pump

Model Entry Exit Output No. 1 (side axis) Exit No. 2 (side axle)
Model Inlet Outlet No. 1 Outlet (shaft end) No. 2 Outlet (shaft end)
S20V (Q) F-12-* F-06-*
S25V (Q) F-12-* F-08-*
S35V (Q) F-16-* F-10-*
S45V (Q) F-24-* F12-*
S2520V (Q) F-20-* F-08-* F-06-*
S3520V (Q) F-24-* F-10-* F-06-*
S3525V (Q) F-24-* F-10-* F-08-*
S4520V (Q) F-28-* F-12-* F-06-*
S4525V (Q) F-28-* F-12-* F-08-*
S4535V (Q) F-32-* F-12-* F-10-*

Installation and Application

Hydraulic Oil
● Anti-wear hydraulic oil is recommended. Viscosity range 10 ~ 100 cSt (1.8 ~ 13° C), recommended viscosity 24 cSt (50° C).
● Filtration: the filtration ratio should not be less than a 25 μm filter, a filter with a filtration ratio must be incorporated at the inlet.
70 ~ 150 μm and with a flow rate ratio of twice that of the pump.
● Rango de temperatura: temperatura ambiente -20 ~ +70° C; Temperatura de trabajo 10 ~ 60° C.
● Fire-resistant fluid: special seals must be used if fire-resistant fluid is employed; for pressure ratios and maximum
pump speed, taking the performance data table as a reference.

2. Installation
● The support and structure for the pump must be reliable, solid, and a good absorber of vibrations.
● Horizontal mounting is recommended to maintain the necessary fluid level in the pump. To extend the life of the pump, it is important
the concentricity of the pump and motor shafts, which should be within a Ø0.1mm. Radial or axial loads should not be applied.
about the shaft of the pump. An elastic coupling must be used, and a rigid coupling is not allowed.
● All joints and hoses must be perfectly sealed to prevent noises and vibrations caused by air that could enter.
through the suction flange.
● Before the pump is put into service, make sure that both the inlet and outlet are correctly connected and that the rotation
the pump is the right one. To prevent cavitation in the pump caused by the first use or by startup
after a long period of inactivity, it is advisable to purge the pump.
When the pump is started, it should be operated without load repeatedly. When the pump is functioning normally
it will be ready to use.
● The suction height of the pump should not exceed 500 mm.

3. Replacement cartridge kit

The cartridge kit design of the SV and SVQ series Gear Pumps provides a fast and efficient field of application. When the kit is replaced
cartridge, the seals inside the pump must be checked to ensure they are not crushed. When tightening the fastening screws,
It must be done with a constant force and diagonally.

Installation and Application

1. Operating Oil
● Anti-wear hydraulic oil is recommended. Its viscosity range: 10 ~ 100 cSt (1.8 ~ 13° C), recommended viscosity 24 cSt (50° C).
● Filtration: the filtration rating shouldn't be lower than 25 μm, a filter with a filtration rating of 70 ~ 150 μm should be fitted at the inlet port.
and its rated flow is more than twice that of the pump.

68
Installation and Application Installation and Application
Hoses for Pump Inlet and Outlet Flange for Inlet and Outlet of Pump

● Temperature range: ambient temperature -20 ~ +70° C; operating temperature 10 ~ 60° C.


● Fire resistance fluid: special seal should be used when using fire resistance fluid; for rated pressure and max. speed of the pump, refer.
to that in the main performance data table.

2. Installation
● Foot and frame for pump must be reliable, solid and good in vibration absorption.
● Horizontal mounting is recommended to maintain necessary case fluid level. Concentricity of shafts between pump and motor is important for
Pump life and should be within Ø0.1mm. Radial or axial load cannot be applied on pump shaft and flexible coupling should be used and rigid.
linkage is not permitted.
● To reduce noise and vibration of the system caused by trapped air, the attachment flange at the inlet port, along with all fittings and pipelines, must be strictly sealed.
● Before starting the pump, you should check if the inlet and outlet have been correctly connected and the rotation of the pump is in line with
the arrow on the nameplate. To prevent the pump from cavitation caused by the first starting or stopping run for a long time, air should be
bled from the pump delivery line. This may be accomplished by loosening a connection in the delivery line close to the pump. An air bleed valve
is available for this purpose. When starting, the pump should be repeatedly jogged without any load. After the pump may normally run, it can be
actually primed.
● Suction lift of pump shouldn't be higher than 500 mm.

3. Replacing cartridge kit.


The cartridge kit design of SV and SVQ series vane pumps offers fast and efficient field serviceability. When replacing the cartridge kit seals inside
the pump should be checked to avoid them crimping; when tightening the fastening screws, they should be treated with even force in diagonal direction.

Aplicaciones de Productos Hidráulicos Applications of Hydraulic Products

Industrial Applications Mobile Machinery Ports and vessels Water Conservation Project Others
Industrial Applications Mobile machinery Port and Ship Water Conservancy Project. Others
Machine tool Construction Excavator Drilling platform
Machine-tool Building Excavator Drilling Platform Dam and Gate Equipment Weapon Building
Hydraulic presses Loader Dragados Aerospace equipment
Hydraulic Press Loader Dredger Reservoir Sluice Aerospace Equipment
Chemical Machinery Forklift Steering systems Recreational machinery
Chemical Machinery Fork Lifter Steering Systems Headstock Gear Recreation Machine
Rubber Machinery Crane Dredging Engineering Sanitary machinery
Rubber Machinery Crane Dredge Engineering Hydroelectric Equipment Sanitary Machinery
Plastic Machinery Hydraulic Crane Propulsion systems Firefighter equipment
Plastics Machinery Hydraulic Crane Propeller Systems Ship Locks Fire-fighting Equipment
Metallurgical Machinery Road roller Boat elevation
Metallurgical Machinery Road Roller Ship Lifter Tide-block Dam Official Truck
Mining Machinery Spreader Port Machinery
Mining Machinery Spreader Deck Machinery Movable Bridge Obstacle Eliminating Mach.
Linber Machinery Earth Moving Machinery Port Machinery Medical machinery
Linber Machinery Earth-moving Machines Port Machinery Desalting Equipment Medical Machinery
Automotive Industry Road Construction Equipment Loaders Mach. Fabric. Bridges Garbage collection trucks
Automobile Manufacturing Road-building Machines Loader and Unloader Bridge-building Machinery Garbage Truck
Skin Machinery
Leather Machinery Grader Bert Building Berth Cracker Pile Driver
Ceramic Machinery Excavation Rock drilling Trams
Ceramic Machinery Digger Reclaiming Engineering Rock Drill Cable Car
Paper Machinery Drilling machinery Concrete pumps Fire Trucks
Paper Machinery Piping Machinery Pushing-up System Concrete Pump Fire Truck
Tunnel Boring Machine Agricultural Machinery Concrete mixers Oil production machinery
Tunneling Machinery Agricultural Machinery Offset Device Concrete Mixer Oil Producing Machinery
Steel Rolling Mills Forest machinery Transport Packaging Machine
Steel Rolling Mill Forest Machinery Mud Barge Conveyor Packing Machine

69
SVQ Series Paddle Pumps SVQ Series Vane Pumps
Double Pump - Model Codes Double Pump - Model Code

F3- S3525VQ 38A21 -1 AA 22 R

(F3-) ****V ** A ** (F) -** * 22 *

Designation Connections No.


Flow Code Flow Code Type Axis Exit positions Rotation
Series Port design

Series Port Design


Flow code Flow code Shaft type Outlet positions Rotation
designation connections No.
Omit 10, 12, 14 2, 3, 4 Seen from the side cover
if I don't 15, 17, 19 5, 6, 7 Viewed from cover end Seen
2520VQ
requires 21, 25 8, 9, 10 Assembly since

Omit 11, 12, 14 Mounting A- opposite entry the axis

if not 2, 3, 4

required 21, 25, 30 5, 6, 7 B- 90° angle of the entrance Viewed from


3520VQ
32, 35, 38 8, 9, 10 shaft end
11, 12, 14 Omit -1 C- online with entry of pump
35, 42, 45 2, 3, 4 if I do not Chaveta
F3- 50, 57, 60 Brida 5, 6, 7 requires strkey D- 90° SH from the entrance
4520VQ
Together 66, 75 SAE 8, 9, 10 Omit R-SH
Vitón 11, 12, 14 if not -86 (Turn to
22
10, 12, 14 required Key Cil. rights)
F3- 21, 25, 30 SAE 15, 17, 19 Reinforced R-CW
3525VQ
Viton 32, 35, 38 Flange 21, 25 Hdstrkey A- opposite inlet port
Seals
35, 42, 45 10, 12, 14 F- -11 B- 90° CCW from inlet L-SAH
50, 57, 60 15, 17, 19 Mounting Striated (I turn to
4525VQ
66, 75 21, 25 with foot Spline C- inline with inlet left
F- L-CCW
35, 42, 45 Foot D- 90° CW from inlet
50, 57, 60 21, 25, 30 mounting
4535VQ
66, 75 32, 35, 38

25
SVQ Series Paddle Pumps SVQ Series Vane Pumps

7.Exit positions Outlet positions

Entry
S4535VQ
Exit No. 1

Exit No. 2

View from the side cover Viewed from cover end of pump

Exit port positions All the series except S4535VQ


S4535VQ
Outlet port positions All series except S4535VQ
Exit No. 2 at 135° South of the entrance Exit No. 2 opposite the entrance
AA
No. 2 outlet 135° CCW from inlet No. 2 outlet opposite inlet
Exit No. 2 at 45° SAH from the entrance Exit No. 2 at 90° SAH from the entrance
AB
Exit No. 1 opposite to the entrance No. 2 outlet 45° CCW from inlet No. 2 outlet 90° CCW from inlet
No. 1 outlet opposite to inlet Exit No. 2 at 45° SH from the entrance Output No. 2 in line with the input
AC
No. 2 outlet 45° CW from inlet No. 2 outlet inline with inlet
Exit No. 2 at 135° SH from the entrance Exit No. 2 at 90° SH from the entrance
AD
No. 2 outlet 135° CW from inlet No. 2 outlet 90° CW from inlet
Exit No. 2 at 135° from the entrance Exit No. 2 opposite to the entrance
BA
No. 2 outlet 135° CCW from inlet No. 2 outlet opposite inlet
Exit No. 2 at 45° SAH from the entrance Exit No. 2 at 90° SAH from the entrance
BB
Exit No. 1 at 90° SAH from the entrance No. 2 outlet 45° CCW from inlet No. 2 outlet 90° CCW from inlet
No. 1 outlet 90° CCW from inlet Exit No. 2 at 45° South of the entrance Output No. 2 in line with the input
BC
No. 2 outlet 45° CW from inlet No. 2 outlet inline with inlet
Exit No. 2 at 135° SH from the entrance Exit No. 2 at 90° SH from the entrance
BD
No. 2 outlet 135° CW from inlet No. 2 outlet 90° CW from inlet
Exit No. 2 at 135° SAH from the entrance Exit No. 2 opposite to the entrance
CA
No. 2 outlet 135° CCW from inlet No. 2 outlet opposite inlet
Exit No. 2 at 45° SAH from the entrance Exit No. 2 at 90° SAH from the entrance
CB
Output No. 1 in line with the input No. 2 outlet 45° CCW from inlet No. 2 outlet 90° CCW from inlet
No. 1 outlet inline with inlet Exit No. 2 at 45° SH from the entrance Exit No. 2 in line with the entrance
CC
No. 2 outlet 45° CW from inlet No. 2 outlet inline with inlet
Exit No. 2 at 135° SE from the entrance Exit No. 2 at 90° SH from the entrance
CD
No. 2 outlet 135° CW from inlet No. 2 outlet 90° CW from inlet
Exit No. 2 at 135° SAH from the entrance Exit No. 2 opposite to the entrance
YES
No. 2 outlet 135° CCW from inlet No. 2 outlet opposite inlet
Exit No. 2 at 45° SAH from the entrance Exit No. 2 at 90° SAH from the entrance
DB
Exit No. 1 at 90° South of the entrance No. 2 outlet 45° CCW from inlet No. 2 outlet 90° CCW from inlet
No. 1 outlet 90° CW from inlet Exit No. 2 at 45° South of the entrance Exit No. 2 in line with the entrance
DC
No. 2 outlet 45° CW from inlet No. 2 outlet inline with inlet
Exit No. 2 at 135° SH from the entrance Exit No. 2 at 90° SH from the entrance
DD
No. 2 outlet 135° CW from inlet No. 2 outlet 90° CW from inlet

8.Design number Design number


9. Rotation (viewed from the axis at the end of the pump) Rotation (viewed from shaft end of pump)
R-SH, right turn for clockwise direction, omit CW Right hand for clockwise, omit
L-SAH, Left turn for counterclockwise direction CCW Left hand for counterclockwise

26
SVQ Series Paddle Pumps SVQ Series Vane Pumps

S252VQ

See optional axes

Entry Ø63.5 Exit No.1 Ø25.4

Exit No.2 Ø19.1

Optional Axes Optional Shafts Cylindrical shaft type with key Straight key shaft type
Model Code Axis F(key)longanchox
A B C ØD E
Model Shaft code F(key)widthxlength
1 59 9.53 11.1 22.23/22.20 24.5/24.4 4.75x32
S2520VQ
86 78 9.53 11.1 25.37/25.35 28.3/28.1 6.36x50.8

Optional Axes Optional Shafts Spline type Splined shaft type


Striated Data Table Spline data table

Code Number of Diameter Diameter Diameter


Model Step
Axis A B C D ØE teeth Mayor Primitive Minor

Shaft Number Major Form Minor


Model Pitch
code of teeth diameter diameter diameter

S2520VQ 11 44.5 9.53 11.1 --- 27.8 13 16/32 22.17/22.15 19.03 18.63/18.35

27
Installation and Application Installation and Application
Hoses for Pump Inlet and Outlet Flange for Inlet and Outlet of Pump

Model Entry Exit Output No. 1 (side axis) Exit No. 2 (side axis)
Model Inlet Outlet No. 1 Outlet (shaft end) No. 2 Outlet (shaft end)
S20V (Q) F-12-* F-06-*
S25V (Q) F-12-* F-08-*
S35V (Q) F-16-* F-10-*
S45V (Q) F-24-* F12-*
S2520V (Q) F-20-* F-08-* F-06-*
S3520V (Q) F-24-* F-10-* F-06-*
S3525V (Q) F-24-* F-10-* F-08-*
S4520V (Q) F-28-* F-12-* F-06-*
S4525V (Q) F-28-* F-12-* F-08-*
S4535V (Q) F-32-* F-12-* F-10-*

Installation and Application

Hydraulic Oil
● Anti-wear hydraulic oil is recommended. Viscosity range 10 ~ 100 cSt (1.8 ~ 13° C), recommended viscosity 24 cSt (50° C).
● Filtration: the filtration ratio should not be less than a 25 μm filter; a filter with a filtration ratio should be incorporated at the inlet.
70 ~ 150 μm and with a flow rate ratio twice that of the pump.
● Rango de temperatura: temperatura ambiente -20 ~ +70° C; Temperatura de trabajo 10 ~ 60° C.
● Fire-resistant fluid: special seals must be used if fire-resistant fluid is employed; for pressure ratios and maximum
pump speed, take as reference the performance data table.

2. Installation
● The support and structure for the pump must be reliable, solid, and a good absorber of vibrations.
● Horizontal mounting is recommended to maintain the necessary fluid level in the pump. To extend the life of the pump, it is important
the concentricity of the pump and motor shafts, which should be within a Ø0.1mm. Radial or axial loads should not be applied
about the pump shaft. An elastic coupling must be used, and a rigid coupling is not allowed.
● All connections and hoses must be perfectly sealed to prevent noise and vibrations caused by air that could enter.
through the suction flange.
● Before putting the pump into service, ensure that both the inlet and outlet are properly connected and that the rotation
The pump is the right one. To prevent cavitation in the pump caused by initial use or by startup.
After a long period of inactivity, it is advisable to purge the pump.
When the pump is started, it should be operated without load in a repetitive manner. When the pump is functioning normally
It will be ready for use.
● The suction height of the pump should not exceed 500 mm.

3.Replacement cartridge kit

The design of the cartridge kit for the SV and SVQ Pump series offers a quick and efficient field of application. When the kit is replaced
cartridge, the seals inside the pump should be checked to ensure they are not compressed. When tightening the securing screws,
it should be done with a constant force and diagonally.

Installation and Application

Operating Oil
● Anti-wear hydraulic oil is recommended. It's viscosity range: 10 ~ 100 cSt (1.8 ~ 13° C), recommended viscosity 24 cSt (50° C).
● Filtration: the filtration rating shouldn't be lower than 25 μm, a filter with filtration rating of 70 ~ 150 μm should be fitted at the inlet port
and its rated flow is more than twice that of the pump.

68
Installation and Application Installation and Application
Brackets for Inlet and Outlet of the Pump Flange for Inlet and Outlet of Pump

● Temperature range: ambient temperature -20 ~ +70° C; operating temperature 10 ~ 60° C.


● Fire resistance fluid: special seal should be used when using fire resistance fluid; for rated pressure and max. Speed of the pump, refer.
to that in the main performance data table.

2. Installation
● Foot and frame for pump must be reliable, solid and good in vibration absorption.
● Horizontal mounting is recommended to maintain necessary case fluid level. Concentricity of shafts between pump and motor is important for
Pump life and should be within Ø0.1mm. Radial or axial load cannot be applied on pump shaft and flexible coupling should be used and rigid.
linkage is not permitted.
● To reduce noise and vibration of the system caused by trapped air, the attachment flange at the inlet port, all fittings and pipelines must be strictly sealed.
● Before starting the pump, you should check if the inlet and outlet have been correctly connected and the rotation of the pump is in line with
the arrow on the nameplate. To prevent the pump from cavitation caused by the first starting or stopping run for a long time, air should be
bled from the pump delivery line. This may be accomplished by loosening a connection in the delivery line close to the pump. An air bleed valve
is available for this purpose. When starting, the pump should be repeatly jogged without any load. After the pump may normally run, it can be
actually primed.
● Suction lift of pump shouldn't be higher than 500 mm.

3. Replacing cartridge kit.


The cartridge kit design of SV and SVQ series vane pumps offers fast and efficient field serviceability. When replacing the cartridge kit seals inside
The pump should be checked to avoid them crimping; when tightening the fastening screws, they should be treated with even force in a diagonal direction.

Applications of Hydraulic Products Applications of Hydraulic Products

Industrial Applications Mobile Machinery Ports and vessels Water Conservation Project Others
Industrial Applications Mobile machinery Port and Ship Water Conservancy Project. Others
Machine tool construction Excavator Drilling platform
Machine-tool Building Excavator Drilling Platform Dam and Gate Equipment Weapon Building
Hydraulic presses Loader Dragados Aerospace equipment
Hydraulic Press Loader Dredger Reservoir Sluice Aerospace Equipment
Chemical Machinery Forklift Steering systems Recreational machinery
Chemical Machinery Fork Lifter Steering Systems Headstock Gear Recreation Machine
Rubber Machinery Crane Dredging Engineering Sanitary machinery
Rubber Machinery Crane Dredge Engineering Hydroelectric Equipment Sanitary Machinery
Plastic Machinery Hydraulic Crane Propulsion systems Firefighters equipment
Plastics Machinery Hydraulic Crane Propeller Systems Ship Locks Fire-fighting Equipment
Metallurgical Machinery Steamroller Boat elevation
Metallurgical Machinery Road Roller Ship Lifter Tide-block Dam Official Truck
Mining Machinery Spreader Port Machinery
Mining Machinery Spreader Deck Machinery Movable Bridge Obstacle Eliminating Machine.
Linber Machinery Earth movements machinery Port Machinery Medical machinery
Linber Machinery Earth-moving Machines Port Machinery Desalting Equipment Medical Machinery
Automobile Industry Road Construction Machinery Loaders Maq. Fabric. Bridges Garbage collection trucks
Automobile Making Road-building Machines Loader and Unloader Bridge-building Machinery Garbage Truck
Skin Machinery
Leather Machinery Grader Bert Building Berth Cracker Pile Driver
Ceramic Machinery Excavation Rock drilling Trams
Ceramic Machinery Digger Reclaiming Engineering Rock Drill Cable Car
Paper Machinery Drilling machinery Concrete pumps Fire Trucks
Paper Machinery Piping Machinery Pushing-up System Concrete Pump Fire Truck
Tunnel Boring Machine Agricultural Machinery Concrete mixers Oil production machinery
Tunneling Machinery Agricultural Machinery Offset Device Concrete Mixer Oil Producing Machinery
Steel Rolling Mills Forest machinery Transport Packaging Machine
Steel Rolling Mill Forest Machinery Mud Barge Conveyor Packing Machine

69

You might also like