Update 1
By. Neil Glenn M. Zaragoza R.C.E, R.M.P., R.S.E.
Mega Review
to receive Update 2
1. DWV stands for?
A. Drainage, Wastage and Ventillation
B. Drainage, Wastewater and Ventillation
C. Drainage, Water Supply and Ventillation
D. Drain, Waste and Vent
E. Doraemon, Wally and Voltes 5
2. CISP stands for?
A. Cast Iron Soil Pipe
B. Cast Iron Sewage Pipe
C. Copper Insulated Soil Pipe
D. Copper Insulated Sewage Pipe
E. Cold Insulated Special Pipe
3. SVTR stands for?
A. Stack Vent Through Roof
B. Soil Vent Through Roof
C. Stack Ventillation True Roof
D. Soil Ventillation True Roof
E. Sewer Vent To Roof
4. EMB stands for?
A. Engineering Management Bureau
B. Environmental Management
Bureau
C. Engineering Monitoring Bureau
D. Environmental Monitoring Bureau
E. Ecosystem Monitoring Bureau
5. 1999 Board of Master Plumber PRC,
Who is the Chairman/Chairwoman?
A. AIDA EMELYN B. LUZ
B. JESUS K. PACHECO
C. FLORENTINO M. GARCIA
D. FORTUNATO M. AMOSCO
E. JOSEPH EJERCITO ESTRADA
F. HERMOGENES POBRE
6. An adequate Plumbing Code is one of the most important
governances in modem and healthful human existence. It involve the
basic necessities of life, such as: (1)AIR (2)WATER (3) FOOD (4)SHELTER
(5) SEX
A. 2 and 3
B. 1, 2 and 3
C. 2, 3 and 4
D. 1, 2, 3 and 4
E. 5 Only
7. The Air gap for drainage shall be not less than _______ between the
plumbing
fixture, appliance or appurtenance outlet and the rim of the floor sink or
receptor.
A. 10mm
B. 15mm
C. 20mm
D. 25mm
E. 30mm
8. Which is not true?
A. Size of Pipe 51mm; Size of Clean
Out 38mm
B. Size of Pipe 64mm; Size of Clean
Out 51mm
C. Size of Pipe 76mm; Size of Clean
Out 64mm
D. Size of Pipe 102mm; Size of Clean
Out 89mm
9. An additional cleanout shall be provided on a horizontal line
with an
aggregate offset angle of direction exceeding:
A. 45 degrees
B. 90 degrees
C. 135 degrees
D. 180 degrees
E. 225 degrees
An
10. CCI Stands for?
A. Centrifugal Cast Iron
B. Copper Cast Iron
C. Cobalt Cast Iron
D. Circumferential Cast Iron
E. Chemical Cast Iron
An
11. CONFINED SPACE- a room or space having a volume less than _________
with 250 kilogram calorie of the aggregate input rating of all fuel burning
appliances installed in that space.
A. 10 Cubic Meter
B. 12 Cubic Meter
C. 14 Cubic Meter
D. 16 Cubic Meter
E. 18 Cubic Meter
An
12. Valves up to and including _________ in size shall be brass
or other approved
materials.
A. 25mm
B. 32mm
C. 51mm
D. 75mm
E. 100mm
An
13. What is the Ratio of Water Closet
for Male Staff for Dormitories
A. 1 WC; 1-15
B. 1 WC; 1-20
C. 1 WC; 1-25
D. 1 WC; 1-30
E. 1 WC; 1-50
14. What is the WSFU for Urinal
(Flush Tank Type)?
A. 1.5
B. 2.0
C. 2.5
D. 3.0
E. 4.0
15. A plumbing permit issued under the provisions of this
Code shall
expire and become null and void if the plumbing work
authorized therein is not commenced within one year from the
date of such permit or if the plumbing work so authorized is
suspended or abandoned at any time after having been
commenced for a period of __________ .
A. 60 Days
B. 120 Days
C. 180 Days
D. 360 Days
E. 720 Days
An
16. That part of the lowest horizontal piping of a drainage
system which receives the discharge from soil, waste and
other drainage pipes inside the walls of the building.
A. Building Sewer
B. Building Drain
C. Building Sub-drain
D. Building Sewage
E. Building Official
An
17. What is the minimum Trap Arm
Size for Laundry Tubs?
A. 32mm
B. 38mm
C. 51mm
D. 76mm
E. 100mm
18. Which is not true for Copper
Tubing?
A. Type K; Green
B. Type L; Blue
C. Type M; Red
D. Type DWV; White
An
19. P-Trap is not commonly used
for?
A. Lavatories
B. Water Closet
C. Sink
D. Floor Drains
E. Scuppers
An
20. In line with rubber gasketed joints, thrust blocks
shall be installed at all except:
A. Changes in direction, as at tees
and bends
B. Changes in size, as at reducers;
C. Stops, as at dead ends
D. Valves, where thrusts may be
expected.
E. None of the Above