Numerical Analysis of Reinforced Concrete Beam Column Joint Retrofitted Using Carbon Fiber Reinforced Polymer Sheets

Uploaded by

seena jalal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
45 views10 pages

Numerical Analysis of Reinforced Concrete Beam Column Joint Retrofitted Using Carbon Fiber Reinforced Polymer Sheets

Uploaded by

seena jalal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd

Numerical Analysis of Reinforced

Concrete Beam Column Joint Retrofitted


using Carbon Fiber Reinforced Polymer
Sheets
Guided By
Prof. REKHA AMBI Presented By
ASSISTANT PROFESSOR, SEENA JALAL
DEPT. OF CIVIL ENGINEERING, Roll No: M20CESC13
TKM COLLEGE OF ENGNEERING. S3 [Link] (SECM)
2

Introduction
 Reinforced Cement Concrete (RCC) structures exhibit distress and damage
 Beam Column Joint - critical region
 Unsafe design and detailing of joint is dangerous
 Retrofitting- increasing seismic resistance of a building
 Retrofitting techniques
 ferrocement jacketing, epoxy injection, shear wall etc.
 Carbon Fiber-Reinforced Polymer (CFRP)
 light-weight, high strength and high corrosion resistance

[Link] Project by Seena Jalal ( M20CESC13) 12/23/2021


3

Significance of work
 Beam column joint
 critical part under seismic actions
 intricate reinforcement detailing
 shear demands are considerably high due to lateral inertia forces
 brittle failures
 Retrofitting and strengthening
 increase in the applied loads
 loss of strength due to deterioration over time
 Successful retrofitting technique of depends on strengthening material

[Link] Project by Seena Jalal ( M20CESC13) 12/23/2021


4
Need of the study
 Beam column joints have a significant influence on the response of the structure

 Cost of replacing the deficient structure exceed the cost of strengthening

 Retrofitting enhances the load carrying capacity of a structure

 Experimental analysis of beam column joint is cumbersome and time consuming

 Numerical analysis helps in modeling and analyzing a retrofitted beam column joints

[Link] Project by Seena Jalal ( M20CESC13) 12/23/2021


5
Novelty of work
 Majority of the literatures experimentally studied the behaviour of retrofitted reinforced
concrete beam column joints
 Literature sources available on analytical study of a retrofitted beam column joint is very
less
 Analytical studies on the behavior of a beam column joint gives a proper understanding of
its structural behavior and also its importance in a structure subjected to gravity and
earthquake loads
 Present study focuses on 3D finite-element analysis of exterior beam column joint
retrofitted using carbon fibre reinforced polymer laminates
 Numerical analysis is done using Abaqus software

[Link] Project by Seena Jalal ( M20CESC13) 12/23/2021


Literature Review 6
Sl AUTHORS JOURNAL TITLE CONCLUSION
No.

1 Al-Rousan et Response of interior beam- • Addition of CFRP results in higher energy dissipation, enhanced ductility, and
al.(2021) column connections integrate more stabilized stiffness degradation
with various schemes of CFRP • Intensity of the stresses within the joint decreased and yielding of steel
composites spreads more to the beam main steel
• CFRP orientation angle had a minor effect on the ultimate horizontal load
2 Wang Seismic Retrofit of Exterior RC  Successful relocation of the failure location from the joint region into the beam
et al.(2019) Beam-Column Joints with end region away from the column face.
Bonded CFRP Reinforcement:  effective suppression of the shear deformation in the joint panel.
An experimental study  Development of a ductile joint failure mode
Llia et Seismic retrofit of reinforced  Improved seismic performance of the deficient beam-column joints in terms of
3
al.
concrete strong beam–weak load-carrying capacity, ductility, and energy dissipation.
(2019)
column joints using EBROG  EBROG method eliminated surface debonding and buckling of CFRP
method combined with CFRP  strengthening shifted the plastic strains and deformations away from the
anchorage
[Link] Project by Seena system
Jalal ( M20CESC13) column face and joint panel zone
12/23/2021
Sl
Literature review (Contd..)
AUTHORS JOURNAL TITLE CONCLUSION
7
No.

4 Akhlaghi Experimental assessment of  EBROG technique was capable of eliminating both the surface debonding
and different anchorage systems  The combination of EBROG technique and 180-degree FRP anchor fan relocated
Mostofinejad used for CFRP flexurally the plastic hinge to the curtailment point of FRP sheets along the beam
(2020) retrofitted exterior RC beam-  The values of the peak strength and energy dissipation capacity were increased
column connections

Obaidat et Retrofitting of partially  The use of CFRP-plates enhanced the load-carrying capacity of joints
5
al.
(2019) damaged reinforced concrete  mode of failure changed from diagonal cracks to debonding of CFRP-plates
beam-column joints using  Initial stiffnesses of the various retrofitted joints were higher than the control
various plate-configurations specimen.
of CFRP under cyclic loading
Singh et al. Experimental studies on  increase in ultimate load carrying capacity and the yield load carrying capacity
6
2014
strength and ductility of  use of CFRP jacketing for retrofitting of initially stressed beam-column joints helps
CFRP jacketed reinforced regain full strength even if stressed up to 85% of ultimate load.
concrete beam-column joints  shifted the failure of the joint from column portion to the beam portion of the joint
[Link] Project by Seena Jalal ( M20CESC13) 12/23/2021
Literature review (Contd..) 8
Sl AUTHORS JOURNAL TITLE CONCLUSION
No.

7 Tahnat et al. Effect of using CFRP wraps on the • CFRP converts the brittle failure to ductile failure
(2018) strength and ductility behaviors of • stirrups continuity inside the joint increases the capacity and ductility
exterior reinforced concrete joint • strengthening approach for beam-column joints extremely effected by
initial design

8 Al-Rousan and Numerical simulation of the • improving the seismic performance of the deficient beam-column joints
Alkhawaldeh influence of bond strength • Eliminated surface debonding or buckling in the FRP composite
(2021) degradation on the behavior of • new guideline is proposed to predict the damage level
reinforced concrete beam-column
joints externally strengthened with
FRP sheets

9 Mostofinejadet 3D beam–column corner joints • The EBROG method eliminate both surface debonding
al.(2019) retrofitted with X-shaped FRP • The plastic hinge was effectively relocated away from the column
sheets attached via the EBROG • CFRP wraps in strengthened joints to inhibit concrete spalling
technique
[Link] Project by Seena Jalal ( M20CESC13) 12/23/2021
9
Research objectives
 To analyze the structural behaviour of exterior beam column joint retrofitted
using carbon fibre reinforced polymer

 To compare the overall load carrying capacity of retrofitted beam column joint to
a normal beam column joint

 To evaluate the ductility, stiffness degradation and energy dissipation capacity of


retrofitted beam column joint

[Link] Project by Seena Jalal ( M20CESC13) 12/23/2021


10

THANK YOU