0% found this document useful (0 votes)
87 views34 pages

Heat Pump Updated Presentation

Heat pump water heaters utilize electricity to transfer heat from the air to water, making them 2 to 3 times more energy efficient than traditional electric heaters. They operate using a thermodynamic cycle involving components like compressors and condensers, achieving significant electricity savings. Various modes such as Green, Auto, and Boost allow for optimized heating based on user needs and environmental conditions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
87 views34 pages

Heat Pump Updated Presentation

Heat pump water heaters utilize electricity to transfer heat from the air to water, making them 2 to 3 times more energy efficient than traditional electric heaters. They operate using a thermodynamic cycle involving components like compressors and condensers, achieving significant electricity savings. Various modes such as Green, Auto, and Boost allow for optimized heating based on user needs and environmental conditions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd

ARISTON GROUP

WHAT is HEAT PUMP

Heat pump water heaters use electricity to “move” heat from


one place to another instead of generating heat directly (like an
ESWH or EIWH)
In doing so, HP can be 2

HOW??
to 3 times more energy
efficient than
conventional electric
water heaters

HEAT
PUMP
work like a pulls heat from
pulls heat
from the
surrounding
3 x
refrigerator inside a box and
dumps it into air and dumps
in reverse
the surrounding it (at a higher
room temp.) into a
tank
Heat pump technology and its
THERMODYNAMIC
advantages CYCLE
Compressor
Low Pressure 1 2 High Pressure Heat pump uses a thermodynamic cycle
Area Area to heat the water inside the storage tank by means of the
air sucked in the thermal group.
7 GAS low 3
pressure.
The same mechanism (reverse only ) used in
refrigerator.
Gas
Zone A refrigerant fluid (R134a), through status changes,
compression and expansion cycles, removes the heat from
Liquid the air at low temperature and transfers it to domestic
Zone water at a higher temperature.
THERMOSTATI
C
The electric consumption of the product is only
Cold air as a 6 VALVE 5 4 that necessary to give power to the fan (which captures the
Bonus air) and the compressor (which allows the refrigerant fluid
to circulate in the system.
Evaporat Condense Energy
r transfer
or
to the
water
It’s an ecological revolution!

80% savings on electricity bill


compare with electric storage WH, thanks
to the high Coefficient of performance
(COP)

= +
100 80 20
Hot water Free heat from Electricity
air
Much lower electricity load
compared to a standard electric storage

COP
water heater

80 L 200 L

1:4
2500 W 250 W 500 W
X 25 X X5
2,5
4
MAIN COMPONENT - COMPRESSOR

compressor is
a mechanical
device that
increases the
pressure of a
gas by reducing
its volume

BRAND HIGHLY GREE HITACHI PANASONIC COPELAND


220~240/1/50
220~240/1/50 220~240/1/50 220~240/1/50 380~415/3/50
Commercial A/W
(AR-6PM & 10PM HX
Power Source Heat Pump Swimming Pool Swimming Pool Commercial A/W
MT)
Domestic (AR-8 & AR-12SM HX (AR-20 & 50 STP HX (AR-20 & 40 PTP HX
(NUOS SERIES) MT) MT) MT)
Swimming Pool
(AR-6SM HX MT)
R410a
Refrigerant R134a (NUOS)
(A/W & Swimming Pool)
Max. Operating
2,8 MPa 4,2 MPa
pressure
Type Rotary Scroll
MAIN COMPONENT - FAN MOTOR &
BLADE
Fans provide the needed air flow through the
unit’s evaporator, guaranteeing a proper heat
extraction
MAIN COMPONENT - CONDENSER/HEAT
EXCHANGER
Within the condenser, the refrigerant gives its heat to the water, warming it up

The coil of the “Tube in Shell” Shell heat exchanger, in


condenser is wrapped heat exchanger titanium, for corrosive
around the tank, waters
outside it.
DOMESTIC COMMERCIAL SWIMMING POOL
MAIN COMPONENT - EVAPORATOR
Refrigerant goes into the evaporator
(invested by surrounding air flow pushed by
the fan) and gets heat from the air by
evaporating
MAIN COMPONENT - THERMOSTATIC VALVE
Adjusts the gas flow rate according to the pressure and temperature inside the gas circulating
system.
TYPE OF HEAT PUMP WATER HEATER
Hot water tank

Thermal
group Hot
Water Thermal group
tank

Hot
Water
tank

Thermal
group

DOMESTIC DOMESTIC SPLIT COMMERCIAL


MONOBLOC
TYPE OF HEAT PUMP WATER HEATER – Commercial

Air-to-”pool” Air-to-water Water-to-water


3

1 2

TRANSFER TO THE WATER


ZONA

FAN / BLOWER
COLD AIR
GAS

ZONA
COMPRESSOR CAIRAN

6 5

EVAPORATOR CONDENSER 4
EXPANSION
VALVE

Heat Heat Heat


Pump Pump Pump

WATER
AIR TO AIR TO
TO
WATER WATER
WATER
HEAT HEAT
PUMP HEAT
PUMP Ground
Air Air Stora PUMP
or Storag
Sourc Pool Sourc ge Chiller e Tank
e e Tank output

NAMING: XXX to YYY HEAT PUMP


• XXX the source of the heat
• YYY the outlet receiving the heat  in our case is always water, because we are making hot water (e.g. for Air Con we talk about Air to
Air)
FRANKIE 4_HF150/200 – FLOOR STANDING
HEAT PUMP
DOMESTIC NEW TECHNOLOGY DOMESTIC HPWH

COMFORT AND PEACE OF MIND


Functions: Green, Auto, Boost, Voyage and Night mode
Optimum temperature at temp. 55°C in heat pump mode.
Heating Element as backup to ensure satisfaction (up to 75°C).
Friendly HMI with multi-function display
150 - 200 L QUALITY AND DURABILTY
Working at ambient temp. 7 To 43°C.
Titanium Enameled tank with Anti-corrosion Magnesium anode.
Error code on display in case of problem.
EFFICIENCY AND ENERGY SAVING
Refrigerant environment friendly R410a.
Dedicated tank for indoor installation & low noise emission (outdoor unit)
HP HE Max Gas
Sound Hydraulic
Capacit Volt / powe Powe Water connectio Empty
Level connectio
y phase r r Pressu Indoor & n Weight
n Indoor &
(kW) (kW) re outdoor
outdoor

220 V/1
150 0.72 1.8 8 bar 52 dB 3/4 inch 1/4” / 3/8” 50 / 32 Kg
ph
220 V/1
200 0.72 1.8 8 bar 52 dB 3/4 inch 1/4” / 3/8” 75 / 32 Kg
ph
HSF300/27H – FLOOR STANDING
HEAT PUMP
DOMESTIC NEW TECHNOLOGY DOMESTIC HPWH

COMFORT AND PEACE OF MIND


Functions: Green, Auto, Boost, Voyage, Quick and Night mode
Optimum temperature at temp. 62°C in heat pump mode.
Heating Element as backup to ensure satisfaction (up to 75°C).
Friendly HMI with multi-function display
300 L QUALITY AND DURABILTY
Working at ambient temp. -7- 43°C.
Titanium Enameled tank with Anti-corrosion Magnesium anode.
Active Anode (ProTech) double protection for with electronic anode.
Error code on display in case of problem.
EFFICIENCY AND ENERGY SAVING
Refrigerant environment friendly R410a.
Dedicated tank for indoor installation & low noise emission (outdoor unit)
HP HE Max Gas
Sound Hydraulic
Capacit Volt / powe Powe Water connectio Empty
Level connectio
y phase r r Pressu Indoor & n Weight
n Indoor &
(kW) (kW) re outdoor
outdoor

220 V/1 100 / 34


300 0.62 1.5+1 8 bar 52 dB 3/4 inch 1/4” / 3/8”
ph Kg
PRO TECH ANODE
EVO A+

NUOS SPLIT INVERTER

HSF 300 L

*Note:
PRO TECH ANODE: The exclusive PROfessional TECH system solution is
an anodic anti-corrosion electronic protection system with a modulated
current (24 V).
It ensures maximum durability in terms of the boiler used in the water
heater. The electronic circuit creates a difference in potential between
the boiler and the titanium electrode, so that optimal boiler protection is
guaranteed, thereby preventing its corrosion.
BEWARE! If the product is not supplied through a power line, it is not
protected by the Pro-tech anode
WORKING MODES
HEAT PUMP DOMESTIC

GREEN MODE
Water heaters consume the lowest possible electrical energy, heating of the water is performed in Heat Pump Only.
The maximum setting temperature in green mode is depends on the models. Temperature regulation is achieved without using
a heating element that is only activated during operation by anti-legionella bacteria, antifreeze, ambient temperature outside
the range (*) or heat pump error.

Models Power [Watt] Air working temp. NUO


HF SPLIT 150 & 200 720 7 - 43°C S
HF SPLIT 300 620 -7 - 43°C

NUOS PLUS
Working Condition Heat Pump Heating
Condition Element
WI-FI
Condition
Twater < Green modes temp. ON OFF

Tair < Min. air working OFF ON


temp.
Tair > Max. air working OFF ON
temp.
WORKING MODES
HEAT PUMP DOMESTIC

AUTO MODE – COMFORT MODE


Allow the water heater to heat up water with efficient & effective, and if necessary to activate heating element based on Tset-
point.

ON OF
Heat Pump F 55°C or
Initial
62°C
temp. OF
ON OFF
Heating Element F HE1 + HE2
75°
C
WORKING MODES
HEAT PUMP DOMESTIC

BOOST MODE
by activating this mode, the Heat pump will work quickly by combining the heat pump with the Heating element
simultaneously since the Heat Pump was first started / turned on.

BOOST MODE is a mode that must be selected manually by the user if needed hot water in the shortest time possible.

After BOOST mode is selected, the Water heater will run the heat pump and heating element simultaneously. When the water
heater reaches the set temperature, BOOST Mode will automatically switch back to previous mode AUTO/GREEN Mode

ON OFF
Heat Pump 55°C or
Initial 62°C
OFF
temp. ON HE1 HE1 + HE2 75°
Heating Element Back to previous
C
1500 Watt 1500+1000 Watt set (Green/Auto
Mode)

Models Temp. max in Green Mode Temp. Max. in auto/boost Green mode [Watt] Heating Element [Watt]
HF SPLIT 150 & 200 55 75 720 1800
HF SPLIT 300 62 75 620 1500 + 1000
WORKING MODES
HEAT PUMP DOMESTIC

VOYAGE MODE
by activating this mode is allows for programming the number of days of absence, during which the water heater will remain
turned off. The appliance will activate only to supply hot water on the day of arrival; protection against corrosion will continue
to be guaranteed while the product will automatically ensure that the temperature of the water in the tank does not fall below
5°C.
OFF ON
Heat Pump
once holiday time elapses, the operating
Up to several days (1 up to
Initial mode will automatically go to previous
99)
temp. mode.
(Green/Auto Mode)

Models Temp. max in Green Mode Temp. Max. in auto/boost Green mode [Watt] Heating Element [Watt]
HF SPLIT 150 & 200 55 75 720 1800
HF SPLIT 300 62 75 620 1500 + 1000
WORKING MODES
HEAT PUMP DOMESTIC

PROGRAM / TIMER MODE


by activating this mode is Activating Program the device allows to reach the set delivery water temperature at the time
required, giving priority to heating by heat pump and, if necessary, through the heating element.
The final user can set two different programs with two different temperatures and times to be performed separately (P1 or P2)
or eventually together (P1+P2).

ON OFF
Time P1
Heat Pump 55°C or
62°C
ON Time P1 < HP OFFP1 > HP
Time
Initial HE1 HE1+H2 75°
Heat Pump+Heating Element BackCto previous
temp
. 1500/1800 Watt 1200/2000/1800/(1500+1000) Watt set (Green/Auto
Heat Pump+Heating Element ON Time P1 ≤ HP OFFP2 >Mode)
Time HP 75°
HE1+H2
Back Cto previous
1200/2000/1800/(1500+1000) Watt set (Green/Auto
Mode)
f the Set Temp > HP Temp & Current Temp > HP Temp. Set → H1 or H1+H2
f the Set Temp > HP TEMP. & Current Temp < HP Temp. Set : Models Green mode [Watt] Heating Element [Watt]
Current Temp. < HP Temp. set → HP, if can’t reached HP+H1 HF SPLIT 150 & 200 720 1800
Current Temp. > HP Temp. set → H1+H2
HF SPLIT 300 620 1500 + 1000
f the Set Temp. < HP Temp. Set → HP, if can’t reached HP+H1
WORKING MODES
HEAT PUMP DOMESTIC

QUICK MODE
by activating this mode the system will automatically heat the upper-half-tank water in the least time. The “Quick” mode will
turn itself off automatically and “Auto” mode begins to function after the water reach the pre-set temperature

ON OFF
Heat Pump 55°C or
Initial 62°C
OFF
temp. ON HE1 75°
Heating Element Back to previous
C
1500 Watt set (Green/Auto
Mode)

Models Temp. max in Green Mode Temp. Max. in auto/boost Green mode [Watt] Heating Element [Watt]

HF SPLIT 300 62 75 620 1500 + 1000


WORKING MODES
HEAT PUMP DOMESTIC

NIGHT MODE
by activating this mode the system will automatically select the suitable mode to heat the water from 23:00 pm to 6:00, we
can set start and end time to heating by this mode, during the time, system will selected power to heat up the water to
achieved at set time temperature.
ON OFF
HE1*
Heat Pump 55°C or
Initial 1500/1800 Watt 62°C
OFF
temp. ON HE1+H2 HE1+H2 75°
Heating Element Back to previous
C
1500/1800+1000 Watt 1500/1800+1000 Watt set (Green/Auto
Mode)
*optional turn ON, based on the time of the heating process.

Models Temp. max in Green Mode Temp. Max. in auto/boost Green mode [Watt] Heating Element [Watt]

HF SPLIT 150 & 200 55 75 720 1800

HF SPLIT 300 62 75 620 1500 + 1000


HEAT PUMP MARKET
Air/Water

Industrial
House Villas and application
Towers
Water/ Swimming
Water Pool

Domestic and
Chiller
professional
integration
swimming
pools
AR SERIES - COMMERCIAL
HEAT PUMP AIR TO WATER NEW TECHNOLOGY OF HEAT PUMP
EFFICIENCY
COP > 4
Compact Size air to water heat pump with 2 type of compressor
• Rotary compressor → 6 & 10 kW
• Scroll compressor → 20 & 45 kW
R410a ecological refrigerant gas
Electronic Expansion Valve (EEC)
EASY OF USE
Friendly HMI with multi-function display
Water pump embedded (AR-6PM)
Ready for Modbus RS485
SAFETY & RELIABILITY
Pressure and temperature sensors and switches
Working at ambient temperature: -7 up to 45°C (6kW) & -15 up to 45°C
(>6kW)
Automatic defrosting on the safety system.
Over-current and over-temperature protection
COMFORT
Hot water up to 60°C
Fan blade with special «low noise» shape
AR SERIES - COMMERCIAL
HEAT PUMP AIR TO WATER

Technical Data AR-6PM AR-10PM AR-20PTP AR-40PTP

Heating capacity kW 6.8 11.6 23 48

Power Input kW 1.65 2.49 4.84 9.97

COP 4 4.7 ÷ 5 4.7 ÷ 5 4.8 ÷ 5

Max. Power input kW 2 3.68 6.9 14.3

Max. Running
A 10.5 17.1 11.5 24.2
Current

Voltage/Phase 240V/ 1 ph 380V/ 3 ph

Hot water volume L/H 142 250 494 1031

Circulation pump m³/h 1.2 2 4 8.3

Max. Temp.
°C 60
Operation

Refrigerant R410A

Noise dB (A) 59 54 56 61

Water pressure
kpa 36 65 129 110
drop

Water connection Inch 1 1 1¼ 1½


HSF300/27H – DOMESTIC INSTALLATION
HEAT PUMP
GUIDE
DOMESTIC NEW TECHNOLOGY DOMESTIC HPWH

Required Materials
Skilled Person, Who Technically Sound in Refrigreation Cycle.
Vacuume Pump For remove moisture from Tube.
Multi-Meter, for checking Voltage & Wiring.
Other’s Tools like Tester, L Keys, Spanners etc.
300 L
Working at ambient temp. -7- 43°C.
Titanium Enameled tank with Anti-corrosion Magnesium anode.
Active Anode (ProTech) double protection for with electronic anode.
Error code on display in case of problem.
EFFICIENCY AND ENERGY SAVING
Refrigerant environment friendly R410a.
Dedicated tank for indoor installation & low noise emission (outdoor unit)
HP HE Max Gas
Sound Hydraulic
Capacit Volt / powe Powe Water connectio Empty
Level connectio
y phase r r Pressu Indoor & n Weight
n Indoor &
(kW) (kW) re outdoor
outdoor

220 V/1 100 / 34


300 0.62 1.5+1 8 bar 52 dB 3/4 inch 1/4” / 3/8”
ph Kg
NEW PRODUCT RANGE
HS 300 Split IN – FLOOR STANDING
HEAT PUMP
DOMESTIC NEW TECHNOLOGY DOMESTIC HPWH

COMFORT AND PEACE OF MIND


Functions: Standard, ECO, Hybrid
300 L Optimum temperature at temp. 55°C in heat pump mode.
Heating Element as backup to ensure satisfaction (up to 70°C).
Friendly HMI with multi-function display
QUALITY AND DURABILTY
Working at ambient temp. -7 To 43°C.
Titanium Enameled tank with Anti-corrosion Magnesium anode.
Error code on display in case of problem.
EFFICIENCY AND ENERGY SAVING
Refrigerant environment friendly R410a.
Dedicated tank for installation & low noise emission (outdoor unit)
HP HE Max Gas
Sound Hydraulic
Capacit Volt / powe Powe Water connectio Empty
Level connectio
y phase r r Pressu Indoor & n Weight
n Indoor &
(kW) (kW) re outdoor
outdoor

220 V/1
300 5.2 3 8 bar 50 dB 3/4 inch 1/4” / 3/8” 35 / 32 Kg
ph
HS 500 Mono Block IN – FLOOR STANDING
HEAT PUMP
DOMESTIC NEW TECHNOLOGY DOMESTIC HPWH

COMFORT AND PEACE OF MIND


Functions: Standard, ECO, Hybrid
Optimum temperature at temp. 55°C in heat pump mode.
500 L
Heating Element as backup to ensure satisfaction (up to 70°C).
Friendly HMI with multi-function display
QUALITY AND DURABILTY
Working at ambient temp. -7 To 43°C.
Titanium Enameled tank with Anti-corrosion Magnesium anode.
Error code on display in case of problem.
EFFICIENCY AND ENERGY SAVING
Refrigerant environment friendly R410a.
Dedicated tank for installation & low noise emission (outdoor unit)
HP HE Max Gas
Sound Hydraulic
Capacit Volt / powe Powe Water connectio Empty
Level connectio
y phase r r Pressu Indoor & n Weight
n Indoor &
(kW) (kW) re outdoor
outdoor

220 V/1
500 6.2 3 8 bar 54 dB 20 MM 20 MM 73 / 58 Kg
ph
WORKING MODES
HEAT PUMP DOMESTIC

ECO Mode
Water heaters consume the lowest possible electrical energy, heating of the water is performed in Heat Pump Only.
The maximum setting temperature in ECO mode is depends on the models. Temperature regulation is achieved without using a
heating element that is only activated during operation by anti-legionella bacteria, antifreeze, ambient temperature outside
the range (*) or heat pump error.

Mode Capacity Temperature setting range Temperature Hysteresis Heating element

ECO 500L 15C To 55C 12C HEATING ELEMENT OFF


WORKING MODES
HEAT PUMP DOMESTIC

STANDARD MODE
Water heaters consume the lowest possible electrical energy, heating of the water is performed in Heat Pump Only.
The maximum setting temperature in standard mode is depends on the models. Temperature regulation is achieved without
using a heating element that is only activated during operation by anti-legionella bacteria, antifreeze, ambient temperature
outside the range (*) or heat pump error.

Mode Capacity Temperature setting range Temperature Hysteresis Heating element

Standard 500L 15C To 55C 5C


Ambient≥ 2℃: OFF
Ambient< 2℃: ON
WORKING MODES
HEAT PUMP DOMESTIC

Hybrid MODE
Water heaters consume the lowest possible electrical energy, heating of the water is performed in Heat Pump Only.
The maximum setting temperature in Hybrid mode is depends on the models. Temperature regulation is achieved without
using a heating element that is only activated during operation by anti-legionella bacteria, antifreeze, ambient temperature
outside the range (*) or heat pump error.

Mode Capacity Temperature setting range Temperature Hysteresis Heating element

HYBRID 500L 15C To 70C 20C Works Together with Heat Pump
INSTALLATION - GUIDE
NEW TECHNOLOGY DOMESTIC HPWH

1 Vent 10 Domestic hot water Wire


2 Power supply 11 Safety valve Water circulation to ODU
3 Water flow switch 12 Check valve
4 Water temp. sensor 13 Y-filter Water circulation to IDU
5 Water inlet 14 Ball valve
6 Water outlet 15 Tap water Hot water supply
7 Ball valve 16 Anode rod Cold water supply
8 Sewage outlet 17 Electrical heating element Drainage
9 Ball valve 18 Wire controller
TroubleShooting - GUIDE
TroubleShooting - GUIDE

You might also like