Error e0049: Error in the point cloud densification
Error
Error e0049: Error in the point cloud densification.
Description
Processing step 2 stops with the message:
Error e0049: Error in the point cloud densification.
Cause
This error may come from different causes:
- There is not enough RAM
The project .log file contains the message:
Failed with error (bad allocation)!
This means that the RAM available is not enough for the amount of points generated. This may be due to the number of images, their resolution, the processing options or the available resources.
- The image resolution is to high to use the Semi Global Matching Add-on
The project .log file contains any of the following messages:
[Error]: SGM : invalid license
[Error]: SGM : trying to process high-resolution images
This means that the project consists of high resolution images and the high resolution Semi Global Matching add-on is needed.
- The processing area is wrongly defined
The project .log file contains any of the following message:
[Error]: Cannot densify the point cloud! There are 0 points in the densification area!
This means that the Processing Area is defined outside the results of Step 1, and therefore there are no Automatic Tie Points available to be densified.
Solutions
- There is not enough RAM:
The possible solutions are:
1. Use a computer with more RAM.
2. Reduce the number of points generated in the processing options. For step by step instructions: 202560419.
- The image resolution is to high to use the Semi Global Matching Add-on
Change the processing options and process again the step 2:
1. On the Menu bar, click Process > Processing Options...
2. In 2. Point Cloud and Mesh, in the Add-ons tab, unselect Use Semi Global Matching.
3. Click OK.
- The processing area is wrongly defined
1. Change the processing options and process again the step 2:
1. On the Menu bar, click Process > Processing Options...
2. In 2. Point Cloud and Mesh, in the Advanced tab, in the Point Cloud Filters section,deselect Use Processing Area.
3. Click OK.
2. Edit the Processing Area so that it includes Automatic Tie Points: 202560599.