1.查看系统RAID卡型号
[root@localhost storcli]# lspci | grep RAID
0001:06:00.0 RAID bus controller: Broadcom / LSI MegaRAID SAS-3 3108 [Invader] (rev 02)
[root@localhost storcli]#
2.下载storcli
storcli是 Broadcom(原 Avago/LSI)提供的 RAID 卡管理工具,用于替代MegaCli,支持更广泛的 RAID 卡型号,并提供更友好的命令行界面
访问 Broadcom 官方网站下载最新版本:
Broadcom StorCLI 下载页面
3.安装storcli
unzip SAS35_StorCLI_7_23-007.2310.0000.0000.zip
cd storcli_rel/
unzip Unified_storcli_all_os.zip
cd Unified_storcli_all_os/
cd ARM/Linux/
[root@localhost Linux]# rpm -ivh storcli-007.2310.0000.0000-1.aarch64.rpm
准备中... ################################# [100%]
正在升级/安装...
1:storcli-007.2310.0000.0000-1 ################################# [100%]
[root@localhost storcli]# ln -s /opt/MegaRAID/storcli/storcli64 /bin/storcli64
[root@localhost storcli]# storcli64 -v
StorCli SAS Customization Utility Ver 007.2310.0000.0000 Nov 02, 2022
(c)Copyright 2022, Broadcom Inc. All Rights Reserved.
4. 使用 storcli
1.查看 RAID 卡信息:
```bash
[root@localhost ~]# storcli64 show
CLI Version = 007.2310.0000.0000 Nov 02, 2022
Operating system = Linux 5.10.134-16.2.axs8.aarch64
Status Code = 0
Status = Success
Description = None
Number of Controllers = 1
Host Name = localhost.localdomain
Operating System = Linux 5.10.134-16.2.axs8.aarch64
System Overview :
===============
-----------------------------------------------------------------------------------
Ctl Model Ports PDs DGs DNOpt VDs VNOpt BBU sPR DS EHS ASOs Hlth
-----------------------------------------------------------------------------------
0 AVAGOMegaRAIDSAS9361-8i 8 4 1 0 1 0 N/A On - Y 3 Opt
-----------------------------------------------------------------------------------
Ctl=Controller Index|DGs=Drive groups|VDs=Virtual drives|Fld=Failed
PDs=Physical drives|DNOpt=Array NotOptimal|VNOpt=VD NotOptimal|Opt=Optimal
Msng=Missing|Dgd=Degraded|NdAtn=Need Attention|Unkwn=Unknown
sPR=Scheduled Patrol Read|DS=DimmerSwitch|EHS=Emergency Spare Drive
Y=Yes|N=No|ASOs=Advanced Software Options|BBU=Battery backup unit/CV
Hlth=Health|Safe=Safe-mode boot|CertProv-Certificate Provision mode
Chrg=Charging | MsngCbl=Cable Failure
或
[root@localhost ~]# storcli64 /c0 show
Generating detailed summary of the adapter, it may take a while to complete.
CLI Version = 007.2310.0000.0000 Nov 02, 2022
Operating system = Linux 5.10.134-16.2.axs8.aarch64
Controller = 0
Status = Success
Description = None
Product Name = AVAGO MegaRAID SAS 9361-8i
Serial Number = SK00585533
SAS Address = 500605b00fa165a0
PCI Address = 01:06:00:00
System Time = 03/05/2025 14:48:30
Mfg. Date = 02/02/20
Controller Time = 03/05/2025 06:48:29
FW Package Build = 24.21.0-0157
BIOS Version = 6.36.00.3_4.19.08.00_0x06180206
FW Version = 4.680.00-8573
Driver Name = megaraid_sas
Driver Version = 07.714.04.00-rc1
Current Personality = RAID-Mode
Vendor Id = 0x1000
Device Id = 0x5D
SubVendor Id = 0x1000
SubDevice Id = 0x9361
Host Interface = PCI-E
Device Interface = SAS-12G
Bus Number = 6
Device Number = 0
Function Number = 0
Domain ID = 1
Security Protocol = None
Drive Groups = 1
TOPOLOGY :
========
---------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
---------------------------------------------------------------------------
0 - - - - RAID1 Optl N 3.637 TB dflt N N none N N
0 0 - - - RAID1 Optl N 3.637 TB dflt N N none N N
0 0 0 252:2 10 DRIVE Onln N 3.637 TB dflt N N none - N
0 0 1 252:3 11 DRIVE Onln N 3.637 TB dflt N N none - N
---------------------------------------------------------------------------
DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Optl=Optimal|Dgrd=Degraded
Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
TR=Transport Ready
Virtual Drives = 1
VD LIST :
=======
-------------------------------------------------------------
DG/VD TYPE State Access Consist Cache Cac sCC Size Name
-------------------------------------------------------------
0/0 RAID1 Optl RW Yes RWTD - ON 3.637 TB
-------------------------------------------------------------
VD=Virtual Drive| DG=Drive Group|Rec=Recovery
Cac=CacheCade|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|dflt=Default|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady
B=Blocked|Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency
JBOD Drives = 2
JBOD LIST :
=========
----------------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
----------------------------------------------------------------------------------------
252:0 8 JBOD - 447.130 GB SATA SSD N N 512B SAMSUNG MZ7LH480HAHQ-00005 U -
252:1 9 JBOD - 447.130 GB SATA SSD N N 512B SAMSUNG MZ7LH480HAHQ-00005 U -
----------------------------------------------------------------------------------------
ID=JBOD Target ID|EID=Enclosure Device ID|Slt=Slot No|DID=Device ID|Onln=Online
Offln=Offline|Intf=Interface|Med=Media Type|SeSz=Sector Size
SED=Self Encryptive Drive|PI=Protection Info|Sp=Spun|U=Up|D=Down
Physical Drives = 4
PD LIST :
=======
----------------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
----------------------------------------------------------------------------------------
252:0 8 JBOD - 447.130 GB SATA SSD N N 512B SAMSUNG MZ7LH480HAHQ-00005 U -
252:1 9 JBOD - 447.130 GB SATA SSD N N 512B SAMSUNG MZ7LH480HAHQ-00005 U -
252:2 10 Onln 0 3.637 TB SATA HDD N N 512B ST4000NM000A-2HZ100 U -
252:3 11 Onln 0 3.637 TB SATA HDD N N 512B ST4000NM000A-2HZ100 U -
----------------------------------------------------------------------------------------
EID=Enclosure Device ID|Slt=Slot No|DID=Device ID|DG=DriveGroup
DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare
UBad=Unconfigured Bad|Sntze=Sanitize|Onln=Online|Offln=Offline|Intf=Interface
Med=Media Type|SED=Self Encryptive Drive|PI=Protection Info
SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign
UGUnsp=UGood Unsupported|UGShld=UGood shielded|HSPShld=Hotspare shielded
CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded
UBUnsp=UBad Unsupported|Rbld=Rebuild
Enclosures = 1
Enclosure LIST :
==============
--------------------------------------------------------------------
EID State Slots PD PS Fans TSs Alms SIM Port# ProdID VendorSpecific
--------------------------------------------------------------------
252 OK 8 4 0 0 0 0 1 - SGPIO
--------------------------------------------------------------------
EID=Enclosure Device ID | PD=Physical drive count | PS=Power Supply count
TSs=Temperature sensor count | Alms=Alarm count | SIM=SIM Count | ProdID=Product ID
[root@localhost ~]#
/c0 表示控制器编号(通常为 0)。
2.查看物理磁盘信息:
[root@localhost ~]# storcli64 /c0/eall/sall show
CLI Version = 007.2310.0000.0000 Nov 02, 2022
Operating system = Linux 5.10.134-16.2.axs8.aarch64
Controller = 0
Status = Success
Description = Show Drive Information Succeeded.
Drive Information :
=================
----------------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
----------------------------------------------------------------------------------------
252:0 8 JBOD - 447.130 GB SATA SSD N N 512B SAMSUNG MZ7LH480HAHQ-00005 U -
252:1 9 JBOD - 447.130 GB SATA SSD N N 512B SAMSUNG MZ7LH480HAHQ-00005 U -
252:2 10 Onln 0 3.637 TB SATA HDD N N 512B ST4000NM000A-2HZ100 U -
252:3 11 Onln 0 3.637 TB SATA HDD N N 512B ST4000NM000A-2HZ100 U -
----------------------------------------------------------------------------------------
EID=Enclosure Device ID|Slt=Slot No|DID=Device ID|DG=DriveGroup
DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare
UBad=Unconfigured Bad|Sntze=Sanitize|Onln=Online|Offln=Offline|Intf=Interface
Med=Media Type|SED=Self Encryptive Drive|PI=Protection Info
SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign
UGUnsp=UGood Unsupported|UGShld=UGood shielded|HSPShld=Hotspare shielded
CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded
UBUnsp=UBad Unsupported|Rbld=Rebuild
/c0:控制器编号。
/eall:所有机箱(enclosure)。
/sall:所有槽位(slot)。
3.查看虚拟磁盘信息:
[root@localhost ~]# storcli64 /c0/vall show
CLI Version = 007.2310.0000.0000 Nov 02, 2022
Operating system = Linux 5.10.134-16.2.axs8.aarch64
Controller = 0
Status = Success
Description = None
Virtual Drives :
==============
-------------------------------------------------------------
DG/VD TYPE State Access Consist Cache Cac sCC Size Name
-------------------------------------------------------------
0/0 RAID1 Optl RW Yes RWTD - ON 3.637 TB
-------------------------------------------------------------
VD=Virtual Drive| DG=Drive Group|Rec=Recovery
Cac=CacheCade|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|dflt=Default|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady
B=Blocked|Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency
/vall:所有虚拟磁盘。
4.创建 RAID 阵列:
例如,创建 RAID 1:
storcli /c0 add vd type=raid1 drives=252:0,252:1
252:0 和 252:1 是物理磁盘的编号(格式为 enclosure:slot)。
5.删除 RAID 阵列:
storcli /c0/v0 del
/v0:虚拟磁盘编号。
6.查看 RAID 卡健康状态:
storcli /c0 show health
7.查看 RAID 卡日志:
storcli /c0 show events
8.重建 RAID 阵列:
storcli /c0/v0 start rebuild pd=252:2
252:2:替换的物理磁盘编号。
9.检查电池状态(BBU):
storcli /c0/bbu show
10.更新 RAID 卡固件:
storcli /c0 download file=filename.rom