麒麟操作系统配置RAID后如何查看磁盘信息

1.查看系统RAID卡型号

[root@localhost storcli]# lspci | grep RAID
0001:06:00.0 RAID bus controller: Broadcom / LSI MegaRAID SAS-3 3108 [Invader] (rev 02)
[root@localhost storcli]# 

2.下载storcli

storcli是 Broadcom(原 Avago/LSI)提供的 RAID 卡管理工具,用于替代MegaCli,支持更广泛的 RAID 卡型号,并提供更友好的命令行界面
访问 Broadcom 官方网站下载最新版本:
Broadcom StorCLI 下载页面
在这里插入图片描述

3.安装storcli

 unzip SAS35_StorCLI_7_23-007.2310.0000.0000.zip
 cd storcli_rel/
 unzip Unified_storcli_all_os.zip
 cd Unified_storcli_all_os/
 cd  ARM/Linux/
 [root@localhost Linux]# rpm -ivh storcli-007.2310.0000.0000-1.aarch64.rpm 
准备中...                          ################################# [100%]
正在升级/安装...
   1:storcli-007.2310.0000.0000-1     ################################# [100%]
[root@localhost storcli]# ln -s /opt/MegaRAID/storcli/storcli64 /bin/storcli64
[root@localhost storcli]# storcli64 -v

      StorCli SAS Customization Utility Ver 007.2310.0000.0000 Nov 02, 2022

    (c)Copyright 2022, Broadcom Inc. All Rights Reserved.

在这里插入图片描述

4. 使用 storcli

1.查看 RAID 卡信息:


```bash
[root@localhost ~]# storcli64 show
CLI Version = 007.2310.0000.0000 Nov 02, 2022
Operating system = Linux 5.10.134-16.2.axs8.aarch64
Status Code = 0
Status = Success
Description = None

Number of Controllers = 1
Host Name = localhost.localdomain
Operating System  = Linux 5.10.134-16.2.axs8.aarch64

System Overview :
===============

-----------------------------------------------------------------------------------
Ctl Model                   Ports PDs DGs DNOpt VDs VNOpt BBU sPR DS EHS ASOs Hlth 
-----------------------------------------------------------------------------------
  0 AVAGOMegaRAIDSAS9361-8i     8   4   1     0   1     0 N/A On  -  Y      3 Opt  
-----------------------------------------------------------------------------------

Ctl=Controller Index|DGs=Drive groups|VDs=Virtual drives|Fld=Failed
PDs=Physical drives|DNOpt=Array NotOptimal|VNOpt=VD NotOptimal|Opt=Optimal
Msng=Missing|Dgd=Degraded|NdAtn=Need Attention|Unkwn=Unknown
sPR=Scheduled Patrol Read|DS=DimmerSwitch|EHS=Emergency Spare Drive
Y=Yes|N=No|ASOs=Advanced Software Options|BBU=Battery backup unit/CV
Hlth=Health|Safe=Safe-mode boot|CertProv-Certificate Provision mode
Chrg=Charging | MsngCbl=Cable Failure
或
[root@localhost ~]# storcli64  /c0 show
Generating detailed summary of the adapter, it may take a while to complete.

CLI Version = 007.2310.0000.0000 Nov 02, 2022
Operating system = Linux 5.10.134-16.2.axs8.aarch64
Controller = 0
Status = Success
Description = None

Product Name = AVAGO MegaRAID SAS 9361-8i
Serial Number = SK00585533
SAS Address =  500605b00fa165a0
PCI Address = 01:06:00:00
System Time = 03/05/2025 14:48:30
Mfg. Date = 02/02/20
Controller Time = 03/05/2025 06:48:29
FW Package Build = 24.21.0-0157
BIOS Version = 6.36.00.3_4.19.08.00_0x06180206
FW Version = 4.680.00-8573
Driver Name = megaraid_sas
Driver Version = 07.714.04.00-rc1
Current Personality = RAID-Mode 
Vendor Id = 0x1000
Device Id = 0x5D
SubVendor Id = 0x1000
SubDevice Id = 0x9361
Host Interface = PCI-E
Device Interface = SAS-12G
Bus Number = 6
Device Number = 0
Function Number = 0
Domain ID = 1
Security Protocol = None
Drive Groups = 1

TOPOLOGY :
========

---------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type  State BT     Size PDC  PI SED DS3  FSpace TR 
---------------------------------------------------------------------------
 0 -   -   -        -   RAID1 Optl  N  3.637 TB dflt N  N   none N      N  
 0 0   -   -        -   RAID1 Optl  N  3.637 TB dflt N  N   none N      N  
 0 0   0   252:2    10  DRIVE Onln  N  3.637 TB dflt N  N   none -      N  
 0 0   1   252:3    11  DRIVE Onln  N  3.637 TB dflt N  N   none -      N  
---------------------------------------------------------------------------

DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Optl=Optimal|Dgrd=Degraded
Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
TR=Transport Ready

Virtual Drives = 1

VD LIST :
=======

-------------------------------------------------------------
DG/VD TYPE  State Access Consist Cache Cac sCC     Size Name 
-------------------------------------------------------------
0/0   RAID1 Optl  RW     Yes     RWTD  -   ON  3.637 TB      
-------------------------------------------------------------

VD=Virtual Drive| DG=Drive Group|Rec=Recovery
Cac=CacheCade|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|dflt=Default|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady
B=Blocked|Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency

JBOD Drives = 2

JBOD LIST :
=========

----------------------------------------------------------------------------------------
EID:Slt DID State DG       Size Intf Med SED PI SeSz Model                      Sp Type 
----------------------------------------------------------------------------------------
252:0     8 JBOD  -  447.130 GB SATA SSD N   N  512B SAMSUNG MZ7LH480HAHQ-00005 U  -    
252:1     9 JBOD  -  447.130 GB SATA SSD N   N  512B SAMSUNG MZ7LH480HAHQ-00005 U  -    
----------------------------------------------------------------------------------------

ID=JBOD Target ID|EID=Enclosure Device ID|Slt=Slot No|DID=Device ID|Onln=Online
Offln=Offline|Intf=Interface|Med=Media Type|SeSz=Sector Size
SED=Self Encryptive Drive|PI=Protection Info|Sp=Spun|U=Up|D=Down

Physical Drives = 4

PD LIST :
=======

----------------------------------------------------------------------------------------
EID:Slt DID State DG       Size Intf Med SED PI SeSz Model                      Sp Type 
----------------------------------------------------------------------------------------
252:0     8 JBOD  -  447.130 GB SATA SSD N   N  512B SAMSUNG MZ7LH480HAHQ-00005 U  -    
252:1     9 JBOD  -  447.130 GB SATA SSD N   N  512B SAMSUNG MZ7LH480HAHQ-00005 U  -    
252:2    10 Onln  0    3.637 TB SATA HDD N   N  512B ST4000NM000A-2HZ100        U  -    
252:3    11 Onln  0    3.637 TB SATA HDD N   N  512B ST4000NM000A-2HZ100        U  -    
----------------------------------------------------------------------------------------

EID=Enclosure Device ID|Slt=Slot No|DID=Device ID|DG=DriveGroup
DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare
UBad=Unconfigured Bad|Sntze=Sanitize|Onln=Online|Offln=Offline|Intf=Interface
Med=Media Type|SED=Self Encryptive Drive|PI=Protection Info
SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign
UGUnsp=UGood Unsupported|UGShld=UGood shielded|HSPShld=Hotspare shielded
CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded
UBUnsp=UBad Unsupported|Rbld=Rebuild
Enclosures = 1
Enclosure LIST :
==============
--------------------------------------------------------------------
EID State Slots PD PS Fans TSs Alms SIM Port# ProdID VendorSpecific 
--------------------------------------------------------------------
252 OK        8  4  0    0   0    0   1 -     SGPIO                 
--------------------------------------------------------------------
EID=Enclosure Device ID | PD=Physical drive count | PS=Power Supply count
TSs=Temperature sensor count | Alms=Alarm count | SIM=SIM Count | ProdID=Product ID
[root@localhost ~]# 
/c0 表示控制器编号(通常为 0)。

2.查看物理磁盘信息:

[root@localhost ~]# storcli64  /c0/eall/sall show
CLI Version = 007.2310.0000.0000 Nov 02, 2022
Operating system = Linux 5.10.134-16.2.axs8.aarch64
Controller = 0
Status = Success
Description = Show Drive Information Succeeded.


Drive Information :
=================

----------------------------------------------------------------------------------------
EID:Slt DID State DG       Size Intf Med SED PI SeSz Model                      Sp Type 
----------------------------------------------------------------------------------------
252:0     8 JBOD  -  447.130 GB SATA SSD N   N  512B SAMSUNG MZ7LH480HAHQ-00005 U  -    
252:1     9 JBOD  -  447.130 GB SATA SSD N   N  512B SAMSUNG MZ7LH480HAHQ-00005 U  -    
252:2    10 Onln  0    3.637 TB SATA HDD N   N  512B ST4000NM000A-2HZ100        U  -    
252:3    11 Onln  0    3.637 TB SATA HDD N   N  512B ST4000NM000A-2HZ100        U  -    
----------------------------------------------------------------------------------------

EID=Enclosure Device ID|Slt=Slot No|DID=Device ID|DG=DriveGroup
DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare
UBad=Unconfigured Bad|Sntze=Sanitize|Onln=Online|Offln=Offline|Intf=Interface
Med=Media Type|SED=Self Encryptive Drive|PI=Protection Info
SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign
UGUnsp=UGood Unsupported|UGShld=UGood shielded|HSPShld=Hotspare shielded
CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded
UBUnsp=UBad Unsupported|Rbld=Rebuild
/c0:控制器编号。
/eall:所有机箱(enclosure)。
/sall:所有槽位(slot)。

3.查看虚拟磁盘信息:

[root@localhost ~]# storcli64 /c0/vall show
CLI Version = 007.2310.0000.0000 Nov 02, 2022
Operating system = Linux 5.10.134-16.2.axs8.aarch64
Controller = 0
Status = Success
Description = None


Virtual Drives :
==============

-------------------------------------------------------------
DG/VD TYPE  State Access Consist Cache Cac sCC     Size Name 
-------------------------------------------------------------
0/0   RAID1 Optl  RW     Yes     RWTD  -   ON  3.637 TB      
-------------------------------------------------------------

VD=Virtual Drive| DG=Drive Group|Rec=Recovery
Cac=CacheCade|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|dflt=Default|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady
B=Blocked|Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency
/vall:所有虚拟磁盘。

4.创建 RAID 阵列:

例如,创建 RAID 1:

storcli /c0 add vd type=raid1 drives=252:0,252:1

252:0 和 252:1 是物理磁盘的编号(格式为 enclosure:slot)。

5.删除 RAID 阵列:

storcli /c0/v0 del

/v0:虚拟磁盘编号。

6.查看 RAID 卡健康状态:

storcli /c0 show health

7.查看 RAID 卡日志:

storcli /c0 show events

8.重建 RAID 阵列:

storcli /c0/v0 start rebuild pd=252:2

252:2:替换的物理磁盘编号。

9.检查电池状态(BBU):

storcli /c0/bbu show

10.更新 RAID 卡固件:

storcli /c0 download file=filename.rom
<think>好的,我需要帮助用户在麒麟操作系统查看硬盘类型是固态还是机械。首先,我得回忆一下之前提供的解决方法,比如使用lsblk命令或者查看/sys/block下的文件。麒麟操作系统是基于Linux的,所以这些方法应该适用。 用户提到麒麟系统,可能需要确认是否存在特定的工具或命令差异,但通常标准Linux方法应该有效。首先,lsblk命令简单直接,查看ROTA列是否为1或0。另外,检查/sys/block/sda/queue/rotational文件的内容,返回1是机械,0是固态。这两个方法在之前的引用中有详细说明,应该可以适用。 还需要考虑用户可能不太熟悉终端操作,可能需要给出具体的步骤示例,比如如何打开终端,输入哪些命令。同时,提醒用户注意设备名称是否正确,比如sda、sdb等,避免误操作。 另外,是否有其他方法,比如使用lsscsi或者图形界面工具。引用中提到lsscsi可以查看设备属性,可能第四列显示SSD。如果用户喜欢图形界面,可以建议安装CrystalDiskInfo类似的工具,但麒麟系统可能默认没有,需要额外安装,这可能不太方便。 还需要注意权限问题,比如查看/sys/block文件可能需要sudo权限吗?不过通常这些文件是只读的,用户可以直接cat查看,可能不需要sudo。但不同系统配置可能有差异,需要提醒用户如果遇到权限问题如何处理。 最后,生成相关问题需要考虑用户可能的后续疑问,比如性能优化、备份策略等,结合引用中的信息,比如定时备份到机械硬盘,可以生成相关问题。</think>### 麒麟操作系统判断硬盘类型的方法 麒麟操作系统基于Linux内核,可通过以下方法判断硬盘类型(SSD/HDD): #### 方法一:使用 `lsblk` 命令 1. 打开终端,输入命令: ```bash lsblk -d -o NAME,SIZE,ROTA ``` 2. 观察 `ROTA` 列: - **1**:表示机械硬盘(HDD)[^1][^2] - **0**:表示固态硬盘(SSD)[^1][^2] ![示例输出](https://example.com/lsblk-output.png) #### 方法二:查看 `/sys/block` 属性文件 1. 输入命令(以 `sda` 为例): ```bash cat /sys/block/sda/queue/rotational ``` - **输出1**:机械硬盘(HDD) - **输出0**:固态硬盘(SSD)[^2] #### 方法三:使用 `lsscsi` 工具 1. 安装 `lsscsi`(若未预装): ```bash sudo apt install lsscsi ``` 2. 输入命令 `lsscsi`,观察第四列设备类型标识: - 若包含 `SSD` 字样则为固态硬盘 #### 注意事项 - 设备名称(如 `sda`)需通过 `lsblk` 或 `fdisk -l` 确认[^4] - 适用于直通盘判断,RAID阵列需额外分析[^1]
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包

打赏作者

黑蛋同志

你的鼓励将是我创作的最大动力

¥1 ¥2 ¥4 ¥6 ¥10 ¥20
扫码支付:¥1
获取中
扫码支付

您的余额不足,请更换扫码支付或充值

打赏作者

实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值