0% found this document useful (0 votes)
64 views1 page

International Limited: Certificate of Visual Examination and Mpi

This document is a certificate of visual examination and magnetic particle inspection (MPI) issued by JC International Limited. It certifies that an MPI was performed on April 27, 2012 on a 3.5" center latch with identification number 557, 978 117. The inspection found no cracks or defects in the accessible areas of the equipment. The inspection was performed according to API RP 8B and JOP-020 procedures at the location of SEDCO 702 for Transocean Support Services.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
64 views1 page

International Limited: Certificate of Visual Examination and Mpi

This document is a certificate of visual examination and magnetic particle inspection (MPI) issued by JC International Limited. It certifies that an MPI was performed on April 27, 2012 on a 3.5" center latch with identification number 557, 978 117. The inspection found no cracks or defects in the accessible areas of the equipment. The inspection was performed according to API RP 8B and JOP-020 procedures at the location of SEDCO 702 for Transocean Support Services.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

JC International Limited

RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Certificate No. 64782 Identification Number Date of Examination 27/04/12 Examiner Qualifications SNT LEVEL II MT, PT & UT

SIMON OGBAN

Description of Equipment: 3.1/2 CENTER LATCH

557, 978 117

DIMENSIONS Top Bore Diameter: 5.5/8 Middle Bore: 4.1/8 Bottom Bore: N/A Right Ear: 4.3/8 Left Ear: 4.5/16 Door Gap: 7/32 Hinge Gap: 3/8 Shoulder Condition: Ok Spring Condition: Ok

EQUIPMENT TYPE - M G G MANUFACTURER VARCO BJ


METHOD: All accessible areas were subjected to a magnetic particle testing. No crack

or crack-like indication was found.

LOCATION: DRILL FLOOR


SPECIFICATION : API RP 8B MPI METHOD: WET VISIBLE MATERIAL: CARBON STEEL. EQUIPMENT USED: PERMANENT MAGNET COMSUMABLES USED: (a)CONTRAST PAINT (b)BLACK MAGNETIC INK RESULT: NO DEFECT FOUND (NDF) Name and address of equipment owner: Address of premises where Test / Examination was held: TEST PROCEDURE: JOP-020 MAGNETIZING CURRENT: DC MAGNETIZING METHOD: CONTINUOSE MAGNETIC FIELD INDICATOR: BURMAH CASTROL

Transocean Support Services

SEDCO 702

We hereby certify that on 27/04/2012 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector: Name of Inspector: SIMON OGBAN

Revision No: 01

Doc No: JCI-C-VMPI-01

You might also like