0% found this document useful (0 votes)
471 views4 pages

Insulation Test Marina 15

This document summarizes the insulation test results for the electrical systems on a tugboat called Marina 15. It provides details of the main generator, auxiliary engine, diesel generator and alternator used to power the vessel. Measurement results are presented from insulation resistance tests of the main generator, charger circuits, stateroom circuits, and navigation panel. Readings were taken on board the vessel on September 9, 2012 and witnessed by a class surveyor.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
471 views4 pages

Insulation Test Marina 15

This document summarizes the insulation test results for the electrical systems on a tugboat called Marina 15. It provides details of the main generator, auxiliary engine, diesel generator and alternator used to power the vessel. Measurement results are presented from insulation resistance tests of the main generator, charger circuits, stateroom circuits, and navigation panel. Readings were taken on board the vessel on September 9, 2012 and witnessed by a class surveyor.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 4

APPROVED BY:

Owner or Yard Manager PT .BAHTERA BAHARI SHIPYARD BKI Surveyor

TRESYA

IR. ACEP SUBARKAH

Builder & Design By LOA : Owner B : H Vessel :

PT. BAHTERA BAHARI SHIPYARD


JL. SEI BINTI, SAGULUNG 29422 TANJUNG UNCANG, BATAM INDONESIA Phone: (+62)778-600 6000, 600 6001 Fax: (+62)778-600 6002 Email: [email protected]

300 80 18

FT

VESSEL TYPE

DECK CARGO BARGE

DATE

15/12/2009

FT OWNER : PT. BAHTERA PT. PELNASBAHTERA BESTARI SHIPPINGBESTARI FT HULL.NO. : H-064 & H-065 MARINE POWER 3015 SHIPPING CLASS : GERMANISCHER LLOYD

MARINA 15
Vessel Type Title

29M TUG

INSULATION TEST

Class Flag Prep. by Date Scale Hull No. Reg No. Sheet No.

: : : : : : : :

Biro Klasifikasi Indonesia Indonesia Afandy Sept 10th, 2012 NTS -

PT. BAHTERA BAHARI SHIPYARD


1

-1-

Jl. Sei Binti, Sagulung 29422 Tanjung Uncang Batam Indonesia Telp : +62 6006000 / 6006001 Fax : +62 778 6006002

TEST RECORD INSULATION RESISTANCE


GENERAL DATA Name of Ship Type of Ship Hull No. Length Over All Breadth Moulded Depth Date of Test Place Performer Witness : : : : : : : : : : MARINA 15 Twin Screw Tug 29 m 8 m 3.7 m 09 Sept 2012 On Board Quality Control PT. Bahtera Bahari Shipyard Class Surveyor

PARTICULAR OF MAIN GENERATOR

- Auxiliary Engine
Brand Model Output Revolution Manufacture : CUMMINS : 4BTA3. 9G2 : 50 KW : 1500 Rpm : Dong Feng Cummins Engine Co.Ltd., China

- Diesel Generator
Assembly and distributed by TRIPOWER Corporation Pte. Ltd Brand : JG Model : CCFJ505J-Y Output : 62.5 KVA / 50 KW Frequency : 50 Hz Voltage : 415 Volt Revolution : 1500 Rpm Manufacture : Taizhou Fengde Mec. & Elec. Machinery Co. Ltd.

- Alternator
Brand Model Output Frequency Voltage Revolution Manufacture : SUNVIM : SVH 224 : 62.5 KVA / 50 KW : 50 Hz : 415 Volt : 1500 Rpm : Shandong Sunvim Electrical Machinery Pte. Ltd.

INSULATION TEST MARINA 15 1

PT. BAHTERA BAHARI SHIPYARD


2

-2-

Jl. Sei Binti, Sagulung 29422 Tanjung Uncang Batam Indonesia Telp : +62 6006000 / 6006001 Fax : +62 778 6006002

1. Main Generator Particulars


Description Model Prime Rating Generator No. 1 4BTA.9GM 50 KW, 415 V, 90,2 AMP, 1500 Rpm, 50 Hz, 62,5 KVA Generator No. 2 4BTA.9GM 50 KW, 415 V, 90,2 AMP, 1500 Rpm, 50 Hz, 62,5 KVA

Megger Test From Main Generator


No. 1 2 Description Main Generator No. 1 Main Generator No. 2 Circuit G1-1 G2-1 Phase And Ground (M ) R-G S-G T-G 10 9 10 10 12 9 Remark Power Cable Power Cable

Megger Test From Charger


No. 1 2 3 4 5 Description Wheel House Windlass Mess Room DB Radio Battery Charger DC 12 V Radio Battery Charger DC 24 Phase Anground (M ) R-G S-G 397 395 495 524 293 296 814 812 826 813

T-G 405 503 301 822 834

Megger Test From Stater


No. 1 2 3 No. 1 2 3 4 5 6 7 8 9 10 2 Description Fresh Water Transfer Pump Fresh Water Separator Oil Water Separator Description Fresh Water Service Bilge Pump F.O Transfre Anchor Windlass GS/Fire Pump Steering Gear Blower Input 1 Blower Output 1 Blower Input 2 Blower Output 2 Phase And Ground (M ) P-G N-G 1713 1654 1292 1247 1353 1298 Remark Motor Motor Motor Remark Motor Motor Motor Motor Motor Motor Motor Motor Motor Motor

Phase And Ground (M ) R-G S-G T-G 1396 1386 1393 689 691 686 233 227 230 204 201 201 220 222 217 44.6 41.1 41.6 910 903 907 977 985 974 1022 1019 1019 893 919 890

INSULATION TEST MARINA 15

PT. BAHTERA BAHARI SHIPYARD


3

-3-

Jl. Sei Binti, Sagulung 29422 Tanjung Uncang Batam Indonesia Telp : +62 6006000 / 6006001 Fax : +62 778 6006002

Megger Test From Navigation


No. 1 Description Navigation Panel Phase And Ground (M ) P-G N-G 344 351 Remark Switch Box

INSULATION TEST MARINA 15 3