EE 2304 Power Electronics Laboratory Manual
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 1
EE 2304 Power Electronics Laboratory Manual
General Instructions to students for EEE Lab courses
Be punctual to the lab class.
Attend the laboratory classes wearing the prescribed uniform and shoes. Avoid wearing any metallic rings, straps or bangles as they are likely to prove dangerous at times. Girls should put their plait inside their overcoat Boys students should tuck in their uniform to avoid the loose cloth getting into contact with rotating machines. Acquire a good knowledge of the surrounding of your worktable. Know where the various live points are situated in your table. In case of any unwanted things happening, immediately switch off the mains in the worktable. This must be done when there is a power break during the experiment being carried out. Before entering into the lab class, you must be well prepared for the experiment that you are going to do on that day. You must bring the related text book which may deal with the relevant experiment. Get the circuit diagram approved. Prepare the list of equipments and components required for the experiment and get the indent approved. Plan well the disposition of the various equipments on the worktable so that the experiment can be carried out. Make connections as per the approved circuit diagram and get the same verified. After getting the approval only supply must be switched on. For the purpose of speed measurement in rotating machines, keep the tachometer in the extended shaft. Avoid using the brake drum side. Get the reading verified. Then inform the technician so that supply to the worktable can be switched off. You must get the observation note corrected within two days from the date of completion of experiment. Write the answer for all the discussion questions in the observation note. If not, marks for concerned observation will be proportionately reduced. Submit the record note book for the experiment completed in the next class. If you miss any practical class due to unavoidable reasons, intimate the staff in charge and do the missed experiment in the repetition class. Such of those students who fail to put in a minimum of 75% attendance in the laboratory class will run the risk of not being allowed for the University Practical Examination. They will have to repeat the lab course in subsequent semester after paying prescribed fee. Use isolated supply for the measuring instruments like CRO in Power Electronics Laboratory experiments.
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 2
EE 2304 Power Electronics Laboratory Manual
EE 2304 POWER ELECTRONICS LABORATORY
AIM To study the characteristics of switching devices and its applications in rectifier inverter, chopper and resonant converter. List of experiments with objectives and exercises 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Characteristics of SCR Characteristics of TRIAC Characteristics of MOSFET and IGBT Transient characteristics of SCR and MOSFET AC to DC fully controlled converter AC to DC half-controlled converter Step down and step up MOSFET based choppers IGBT based single-phase PWM inverter IGBT based three-phase PWM inverter Resonant dc-to-dc converter
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 3
EE 2304 Power Electronics Laboratory Manual
Ex. No. 1 CHARACTERISTICS OF SCR & ITS APPLICATION
AIM : To determine the characteristics of SCR and to study the operation of Single Phase Single Pulse Converter using SCR. APPARATUS REQUIRED: S.No. 1 2 3 4 5 6 7 8 9 10 11 12 13 APPARATUS SCR Module kit Thyristor Trainer Module Kit Firing Circuit Module Regulated Power Supply Regulated Power Supply DRB Voltmeter Ammeter Ammeter Resistor Loading Rheostat CRO Patch Chords RANGE 220 V / 5 A TYPE QUANTITY 1 1 1 1 1 1 1 1 1 1 1 1 10
(0-5) V (0-30) V (0-30) V (0-30)mA (0-100)A 1 k 50 / 5 A 20 MHZ MC MC MC
PROCEDURE: 1. To determine the Characteristics of SCR 1) 2) 3) 4) 5) 6) Make the connections as per the circuit diagram. Switch on the supply Set the gate current at a fixed value by varying RPS on the gate-cathode side. Increase the voltage applied to anode-cathode side from zero until breakdown occurs. Note down the breakdown voltage. Draw the graph between anode to cathode voltage (v ak) and anode current (ia)
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 4
EE 2304 Power Electronics Laboratory Manual
2. To study the operation of Single Phase Single Pulse Converter. 1) 2) 3) 4) Make the connections as per the circuit diagram Switch on the supply Switch on the supply and observe the waveforms of various firing angle by varying the POT in resistance firing circuit. Observe the range of firing angle control. For any particular triggering angle plot the waveforms of the voltage across the load and the SCR. CIRCUIT DIAGRAM:
TABULAR COLUMN:
IG =.(A) S.No. VAK (V) IA (mA)
IG =.(A) VAK (V) IA (mA)
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 5
EE 2304 Power Electronics Laboratory Manual
MODEL GRAPH: IA I g1
Pin configuration
I g2 ig2 >ig1 VAK K A G ZP4M
CIRCUIT DIAGRAM (SINGLE PHASE SINGLE PULSE CONVERTER) :
TABULAR COLUMN (SINGLE PHASE SINGLE PULSE CONVERTER): S.No. Non-Conducting Period (ms) Conducting Period (ms) Firing Angle ( ) Output Voltage (V)
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 6
EE 2304 Power Electronics Laboratory Manual
MODEL GRAPH (SINGLE PHASE SINGLE PULSE CONVERTER):
Vin 2 3
VT
RESULT: Thus the Characteristics of SCR and the Output waveforms of Single Phase Single Pulse Converter were obtained.
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 7
EE 2304 Power Electronics Laboratory Manual
Ex. No. 2 TRIAC PHASE CONTROL CIRCUIT
AIM: To construct the Single Phase AC Control Circuit using TRIAC for various values of firing angle. APPARATUS REQUIRED: S.No. 1 2 3 4 5 6 7 APPARATUS TRIAC Power Circuit kit TRIAC Firing Circuit kit Isolation Transformer Auto Transformer CRO Loading Rheostat Patch Chords RANGE Single Phase 230 V / 10 A Single Phase 230 V / 5 A 230 / 115 V 230 / 230 V 20 MHZ 100 , 2 A TYPE QUANTITY 1 1 1 1 1 1 10
PROCEDURE: 1) 2) 3) 4) 5) 6) Make the connections as per the circuit diagram. Keep the multiplication factor of CROs probe at maximum position. Switch on the TRIAC knob and firing circuit kit. Vary the firing angle in steps and note the readings of waveforms in CRO. Switch of the supply. Draw the output waveforms. CIRCUIT DIAGRAM: Ph 230 V A.C 50 Hz N 1 Auto Transformer 230V/ 0 210V 1KvA 230V / 115-55-0-115V Isolation Transformer MT2 G MT1 (0 5A) MI A (0 300V) MI V Resistive Load
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 8
EE 2304 Power Electronics Laboratory Manual
TABULAR COLUMN: Firing angle Voltage (v) Time t (ms) Current (A) Practical value o
S.No.
MODEL GRAPH:
RESULT: Thus Single Phase AC Phase Control Circuit using TRIAC was constructed and output waveforms was drawn.
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 9
EE 2304 Power Electronics Laboratory Manual
Ex. No. 3 CHARACTERISTICS OF TRIAC
AIM: To determine the characteristics of TRIAC. APPARATUS REQUIRED: S.No. 1 2 3 4 5 6 7 8 APPARATUS TRIAC Module kit Regulated Power Supply Regulated Power Supply Voltmeter Ammeter Ammeter Resistor Patch Chords RANGE 220 V / 5 A (0-5) V (0-15) V (0-30) V (0-30)mA (0-50)mA 1 k TYPE QUANTITY 1 1 1 1 1 1 1 10
MC MC MC
PROCEDURE: 1. Make the connections as per the circuit diagram. 2. Switch on the supply. 3. Set the gate current at a fixed value by varying RPS on the 4. gate- cathode side. 5. 6. Increase the voltage applied across anode and corresponding current is noted. The above steps are repeated for different values of I G. 7. Draw the graph between anode to cathode voltage (V AK) and anode 8. current (I A)
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 10
EE 2304 Power Electronics Laboratory Manual
CIRCUIT DIAGRAM:
TABULAR COLUMN:
S.No.
IG =.(mA) VAK (V) IA (mA)
IG=.(mA) VAK (V) IA (mA)
MODEL GRAPH:
RESULT : Thus the Characteristics of TRIAC was obtained.
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 11
EE 2304 Power Electronics Laboratory Manual
Ex. No. 4 CHARACTERISTICS OF MOSFET & IGBT
AIM : To determine the characteristics of MOSFET & IGBT.. APPARATUS REQUIRED: S.No. 1 2 3 4 5 6 7 8 9 APPARATUS MOSFET & IGBT Module kit Regulated Power Supply Regulated Power Supply Voltmeter Voltmeter Ammeter DRB Resistor Patch Chords RANGE 220 V / 5 A (0-15) V (0-30) V (0-5) V (0-30) V (0-5)mA 5 K, 1 k TYPE QUANTITY 1 1 1 1 1 1 1 1 10
MC MC MC
PROCEDURE: 1) 2) 3) 4) Make the connections as per the circuit diagram. Switch on the supply. Set the gate current at a fixed value by varying RPS on the gate-cathode side. Vary the voltage applied across Gate and corresponding VDS ( VCE) and ID ( IC ) is noted . 5) 6) 7) The above steps are repeated for different values of I G . Vary the voltage across Collector and Emitter and noted down VGE and IC. Draw the graph between V GS (VCE ) and ID (IC ) and VGS (VGE ) and ID (IC ).
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 12
EE 2304 Power Electronics Laboratory Manual
CIRCUIT DIAGRAM (MOSFET) :
CIRCUIT DIAGRAM (IGBT) :
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 13
EE 2304 Power Electronics Laboratory Manual
TABULAR COLUMN (MOSFET): TRANSFER CHARACTERISTICS:
S.No
VGS =.(V) VDS (mV) ID (mA)
VGS =.(V) VDS (mV) ID (mA)
DRAIN CHARACTERISTICS:
V DS =.(V) S.No VGS (mV) ID (mA)
MODEL GRAPH ( MOSFET ): TRANSFER CHARACTERISTICS DRAIN CHARACTERISTICS
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 14
EE 2304 Power Electronics Laboratory Manual
TABULAR COLUMN (IGBT): TRANSFER CHARACTERISTICS:
S.No
VGE =.(V) VCE (mV) IC (mA)
VGE =.(V) VCE (mV) IC (mA)
DRAIN CHARACTERISTICS:
V CE =.(V) S.No VGE (mV) IC (mA)
MODEL GRAPH (IGBT): TRANSFER CHARACTERISTICS DRAIN CHARACTERISTICS
RESULT: Thus the Characteristics of MOSFET & IGBT were obtained.
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 15
EE 2304 Power Electronics Laboratory Manual
Ex. No. 5
TRANSIENT CHARACTERISTICS OF SCR AND MOSFET
AIM: To determine the transient characteristics of MOSFET & IGBT. APPARATUS REQUIRED: S.No. 1 2 3 4 5 6 7 8 9 10 11 APPARATUS MOSFET & IGBT Module kit Regulated Power Supply Regulated Power Supply Voltmeter Voltmeter Ammeter Ammeter Ammeter DRB Resistor Patch Chords RANGE 220 V / 5 A (0-15) V (0-30) V (0-5) V (0-30) V (0-5)mA (0-10)mA (0-100)A 1 K, 1k, 100 k,5 k, TYPE QUANTITY 1 1 1 1 1 1 1 1 1 1 10
MC MC MC MC MC
PROCEDURE: 1) Make the connections as per the circuit diagram. 2) Switch on the supply. 3) Set the 30 V in the voltmeter using variable DC supply provided in the trainer. gate current at a fixed value by varying RPS on the gate-cathode side. 4) Vary the gate current and note down the values of IA & VA . 5) The above steps are repeated for different values of I G . 6) Draw the graph between VAK (VDS ) and IG (VGS ) and IA (ID) and IG (VGS).
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 16
EE 2304 Power Electronics Laboratory Manual
CIRCUIT DIAGRAM ( SCR ) :
CIRCUIT DIAGRAM (MOSFET):
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 17
EE 2304 Power Electronics Laboratory Manual
TABULAR COLUMN ( SCR ) : S.No. VAK (V) IG (A) IA (mA)
MODEL GRAPH ( SCR ):
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 18
EE 2304 Power Electronics Laboratory Manual
TABULAR COLUMN (MOSFET): S.NO ID (mA)
VGS (V)
VDS (V)
MODEL GRAPH (MOSFET):
RESULT: Thus the Transient Characteristics of SCR & MOSFET were obtained.
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 19
EE 2304 Power Electronics Laboratory Manual
Ex. No. 6 TRIGGERING CIRCUITS FOR SCR
AIM: To construct the R, RC &UJT triggering circuit for SCR and plot its output waveforms. APPARATUS REQUIRED: S.No. 1 2 3 4 5 6 APPARATUS CRO R.P.S DRB Transformer Load Voltmeter RANGE 20 MHz (0-30)V 230/24V 100,2A (0-15)V TYPE QUANTITY 1 1 1 1 1 1
MI
COMPONENTS REQUIRED: S.No. 1 2 3 4 5 ITEM SCR Capacitor Resistor Diode UJT RANGE 104F 1K,2.2K,0.1K 10K,22K IN4007 2N2646 TYPE 2P4M QUANTITY 1 2 1 1 2 1
PROCEDURE: (R-TRIGGERING) 1. Make the connections as per the circuit diagram. 2. Vary the DRB to get maximum resistance value. 3. Switch on the power supply. 4. Note down the output waveform across the load and the voltage across gate cathode using a CRO. 5. Repeat the procedure for various resistor values of potentiometer. 6. Switch off the power and remove the connections. PROCEDURE: (RC-TRIGGERING) 1. Make the connections as per the circuit diagram.
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 20
EE 2304 Power Electronics Laboratory Manual
2. Switch on the power supply. 3. Note down the output waveform across the load using a CRO. 4. Repeat the procedure for various resistor values of potentiometer. 5. Switch off the power and remove the connections.
PROCEDURE: ( UJT-TRIGGERING) 1. 2. 3. 4. 5. Make the connections as per the circuit diagram. Switch on the power supply and set the biasing voltage to 18volts. Note down the waveform of voltages (Vc and Vo) using a CRO . Repeat the procedure for various resistor values of potentiometer. Switch off the power supply and remove the connections.
CIRCUIT DIAGRAM (RESISTANCE FIRING CIRCUIT) : 50/5A LOAD I VO R1 R2 VS D
CRO
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 21
EE 2304 Power Electronics Laboratory Manual
CIRCUIT DIAGRAM (RC-TRIGGERING):
1 Transformer 230/24V Load D 230V AC 10K 1K 50/5A
V
(0-10)VM.I
D 0.47F
CIRCUIT DIAGRAM (UJT-TRIGGERING):
R2
R3
(0-30)V RPS
B2 B1
CR O
C R1
CR O
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 22
EE 2304 Power Electronics Laboratory Manual
TABULAR COLUMN (R-TRIGGERING) : Input Cycle Time (Ms) Voltage Across (Anode- Cathode) V rms (V)
Input S.No. Voltage (V)
Resistance Value (K )
O/P Voltage V rms (V)
MODEL GRAPH ( R-TRIGGERING) :
VS
VL t
VAK
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 23
EE 2304 Power Electronics Laboratory Manual
TABULATOR COLUMN (RC-TRIGGERING): Voltage Resistance Value (K ) O/P Voltage V rms (V) Across (AnodeCathode) V rms (V)
Input S.No. Voltage (V)
Input Cycle Time (Ms)
MODEL GRAPH (RC-TRIGGERING):
Vin t Vc
V0 t
TABULAR COLUMN (UJT-TRIGGERING):
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 24
EE 2304 Power Electronics Laboratory Manual
Resistor S.No. value(r) ()
Capacitor voltage Vc (v)
Charging time (ms)
Discharging Time (ms)
Voltage vo (v)
Time Period (ms)
MODEL GRAPH ( UJT-TRIGGERING) :
Vc
0 t
Vo
t 0 t t RESULT: Thus the R, RC &UJT triggering circuit for SCR was constructed and its output waveforms were plotted.
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 25
EE 2304 Power Electronics Laboratory Manual
Ex. No. 7 AC TO DC HALF CONTROLLED CONVERTER
AIM: To construct a single phase half controlled Converter and plot its output response. APPARATUS REQUIRED: S.NO. 1 3 4 5 6 7 8 FORMULA: t Firing angle 0 = --------- x 180 10ms t= non-conducting period of thyristor. PROCEDURE: 1. Make the connections as per the circuit diagram. 2. Keep the multiplication factor of the CROs probe at the maximum position. 3. Switch on the thyristor kit and firing circuit kit. 4. Keep the firing circuit knob at the 180 position. 5. Vary the firing angle in steps. 1 230V 50Hz AC Supply 6. Note down the voltmeter reading and waveform from the CRO. 7. Switch off the power supply and disconnect. CIRCUIT DIAGRAM : P
OF Isolation 1 Auto DEPARTMENT1 ELECTRICAL AND ELECTRONICS ENGINEERING, REC 26 Transformer Transformer 230V/0-270V
APPARATUS Half controlled Converter Power circuit kit SCR firing circuit kit Isolation Transformer Auto-transformer Loading Rheostat CRO Patch chords
RANGE 1 , 230V,10A 1 ,230V,5A 230V/115-550-55-115 230V/0-270V, 4A 100 / 2A 20MHz -
TYPE -
QUANTITY 1 1 1 1 1 1 15
Resistive Load
EE 2304 Power Electronics Laboratory Manual
T1
T2
D1
D2
TABULATOR COLUMN: Observed Angle O (Degree)
S.No.
Firing Angle Output Voltage Non Conducting (Degree) Vo (Volts) Period T Sec
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 27
EE 2304 Power Electronics Laboratory Manual
MODEL GRAPH:
Vin
2 3 t
VT t
RESULT : Thus a single-phase half controlled converter was constructed and their Output waveforms were plotted.
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 28
EE 2304 Power Electronics Laboratory Manual
Ex. No. 8 AC TO DC FULLY CONTROLLED CONVERTER
AIM: To construct a single phase fully controlled Converter and plot its response. APPARATUS REQUIRED: S.NO ITEM 1 Fully controlled Converter Power 3 4 5 6 7 8 FORMULA : t Firing angle 0 = --------- x 180 10ms t= non-conducting period of thyristor. PROCEDURE: 1. Make the connections as per the circuit diagram.. 2. Keep the multiplication factor of the CROs probe at the maximum position. 3. Switch on the thyristor kit and firing circuit kit. 4. Keep the firing circuit knob at the 180 position. 5. Vary the firing angle in steps. 6. Note down the voltmeter reading and waveform from the CRO. 7. Switch off the power supply and disconnect. circuit kit SCR firing circuit kit Isolation Transformer Auto-transformer Loading Rheostat CRO Patch chords 1 ,230V,5A 230V/115-55-0-55-115 230V/0-270V, 4A 100 / 2A 20MHz 1 1 1 1 1 15 RANGE 1 , 230V,10A TYPE QUANTITY 1
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 29
EE 2304 Power Electronics Laboratory Manual
CIRCUIT DIAGRAM :
1 230V 50Hz AC Supply
Resistive Load
1 Auto Transformer 230V/0-270V
1 -Isolation Transformer 1:1
TABULAR COLUMN: Observed angle o (degree)
S.No.
Firing angle (degree)
Output voltage Vo (volts)
Non conducting Period t sec
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 30
EE 2304 Power Electronics Laboratory Manual
MODEL GRAPH : in
2 3 t
VT
RESULT: Thus a single-phase fully controlled converter was constructed and their responses were plotted.
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 31
EE 2304 Power Electronics Laboratory Manual
Ex. No. 9 STEP UP AND STEP DOWN MOSFET BASED CHOPPERS
AIM: To construct Step down & Step up MOSFET based choppers and to draw its output response. APPARATUS REQUIRED: S.NO ITEM Step up & Step down MOSFET based chopper kit CRO Patch chords 20 MHZ RANGE QUANTITY 1 1 15
1 2 3
PROCEDURE (STEP UP CHOPPER & STEP DOWN CHOPPER) : 1. 2. 3. 4. 5. 6. 7. 8. 9. Initially keep all the switches in the OFF position Initially keep duty cycle POT in minimum position Connect banana connector 24V DC source to 24V DC imput. Connect the driver pulse [output to MOSFET input Switch on the main supply Check the test point waveforms with respect to ground. Vary the duty cyle POT and tabulate the Ton, Toff & output voltage Trace the waveforms of Vo Vs & Io Draw the graph for Vo Vs Duty cycle, K
CIRCUIT DIAGRAM (STEP UP CHOPPER) :
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 32
EE 2304 Power Electronics Laboratory Manual
CIRCUIT DIAGRAM (STEP DOWN CHOPPER):
TABULAR COLUMN (STEP UP CHOPPER):
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 33
EE 2304 Power Electronics Laboratory Manual
Vs = ____________ V S.NO T ON (sec) TOFF (sec) T Duty Ratio, k=TON / T Vo=kVs(V)
(sec)
TABULAR COLUMN (STEP DOWN CHOPPER): Vs = ____________ V S.NO T ON (sec) TOFF (sec) T Duty Ratio, k=TON / T Vo=kVs(V)
(sec)
MODEL GRAPH (STEP UP CHOPPER) :
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 34
EE 2304 Power Electronics Laboratory Manual
MODEL GRAPH (STEP DOWN CHOPPER) :
RESULT: Thus the output response of Step down & Step up MOSFET based choppers were drawn.
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 35
EE 2304 Power Electronics Laboratory Manual
Ex. No. 10 IGBT BASED SINGLE PHASE PWM INVERTER
AIM : To obtain Single phase output wave forms for IGBT based PWM inverter APPARATUS REQUIRED: S.No. 1 2 3 4 ITEM IGBT Based PWM inverter Kit CRO Patch Chord Load rheostat RANGE 220/10A 20MHZ 50/5A TYPE QUANTITY 1 1 10 1
PROCEDURE : 1. Make the connection as per the circuit diagram. 2. Connect the gating signal from the inverter module. 3. Switch ON D.C 24 V. 4. Keep the frequency knob to particulars frequency. 5. Observe the rectangular and triangular carrier waveforms on the CRO. 6. Obtain the output waveform across the load Rheostat.
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 36
EE 2304 Power Electronics Laboratory Manual
CIRCUIT DIAGRAM: +
C1 T1 D1 50/5A 24V,D.C T3 D3
C2 T2 D2
Vo T4 D4
TABULAR COLUMN: S.no Output voltage (v) Time (ms)
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 37
EE 2304 Power Electronics Laboratory Manual
MODEL GRAPH:
Vref
Vcar
Vo
RESULT : Thus the output waveform for IGBT inverter (PWM) was obtained.
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 38
EE 2304 Power Electronics Laboratory Manual
Ex. No. 11 IGBT BASED THREE PHASE PWM INVERTER
AIM: To obtain Three phase output wave forms for IGBT based PWM inverter APPARATUS REQUIRED: S.No. 1 2 3 4 PROCEDURE: 1. Make the connection as per the circuit diagram. 2. Connect the gating signal from the inverter module. 3. Switch ON D.C 24 V. 4. Keep the frequency knob to particulars frequency. 5. Observe the input and output waveforms for 180 conduction mode and 120 conduction mode in the CRO. 6. Obtain the output waveform across the load Rheostat. CIRCUIT DIAGRAM: ITEM IGBT Based PWM inverter Kit CRO Patch Chord Load rheostat RANGE 220/10A 20MHZ 50/5A TYPE QUANTITY 1 1 10 1
LAMP LOAD
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 39
EE 2304 Power Electronics Laboratory Manual
TABULAR COLUMN: S.No. Output Voltage (V) Time (ms)
MODEL GRAPH :
RESULT : Thus the output waveform for IGBT inverter (PWM) was obtained.
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 40
EE 2304 Power Electronics Laboratory Manual
Ex. No. 12 RESONANT DC TO DC CONVERTER
AIM: To study Zero Voltage Switching Resonant converter and Zero Current Switching Resonant Converter and plot its output waveforms. APPARATUS REQUIRED: S.No. ITEM 1 Resonant Converter Module 2 Loading rheostat 3 CRO 4 Patch chords RANGE 100 / 2A 20 MHZ TYPE QUANTITY 1 1 1 15
PROCEDURE (ZVS & ZCS RESONANT CONVERTER): 1. Make the connections as per the circuit diagram. 2. Switch on the resonant converter module. 3. Keep the frequency knob of the firing circuit kit below the resonance Frequency of power circuit kit 4. Switch on the DC power supply connected to the power circuit kit and Switch on the firing circuit kit 5. Vary the frequency knob of the firing circuit kit 6. Observe the waveform from the CRO. 7. Repeat the same procedure for different values of switching frequency. 8. Switch of the power supply and disconnect the connection
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 41
EE 2304 Power Electronics Laboratory Manual
CIRCUIT DIAGRAM (ZVS RESONANT CONVERTER ) :
CIRCUIT DIAGRAM (ZCS RESONANT CONVERTER) :
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 42
EE 2304 Power Electronics Laboratory Manual
TABULAR COLUMN (ZVS RESONANT CONVERTER ) : RESONANT FREQUENCY = S.No. Input voltage (vi) V Switching frequency (hz) Output voltage Vo (V) Output current io (A)
TABULAR COLUMN ( ZCS RESONANT CONVERTER ) : RESONANT FREQUENCY = S.No. Input voltage (vi) V Switching frequency (Hz) Output voltage Vo (V) Output current io (A)
MODEL GRAPH ( ZVS RESONANT CONVERTER ) :
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 43
EE 2304 Power Electronics Laboratory Manual
MODEL GRAPH ( ZCS RESONANT CONVERTER ) :
RESULT : Thus ZVS and ZCS Resonant Converter operation were studied and its output waveform were plotted.
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 44
EE 2304 Power Electronics Laboratory Manual
Ex. No. 13 RESONANT INVERTERS
AIM : To study a Single-phase series inverter and parallel inverter and plot its output waveform. APPARATUS REQUIRED : S.No. ITEM 1 Series inverter power circuit kits 2 Series inverter firing circuit kit 3 Loading rheostat 4 5 6 Regulated power supply CRO Patch chords RANGE 1 ,230 V , 2 A 1 ,230 V , 2 A 100 / 2A (0 30 V) / 2 A 20 MHZ TYPE QUANTITY 1 1 1 1 1 15
PROCEDURE ( SERIES INVERTER ) : 1. Make the connections as per the circuit diagram. 2. Switch on the thyristor firing circuit 3. Keep the frequency knob of the firing circuit kit below the resonance Frequency of power circuit kit 4. Switch on the DC power supply connected to the power circuit kit and Switch on the firing circuit kit 5. Vary the frequency knob of the firing circuit kit 6. Observe the waveform from the CRO. 7. Repeat the same procedure for different values of L,C and load resistance. 8. Switch of the power supply and disconnect the connection 9. Calculate the frequency of the output waveform .
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 45
EE 2304 Power Electronics Laboratory Manual
PROCEDURE (PARALLEL INVERTER ) : 1. Make the connection as per the circuit diagram. 2. Switch on the 24V DC power supply. 3. Vary the output frequency by proper tuning. 4. Obtain the voltage output across secondary of transformer. 5. Obtain also the voltage across Inductance. CIRCUIT DIAGRAM (SERIES INVERTER) :
FUSE(2A )
T1 D1 L1
(0-30V), M.I V
C1
(0-30)V RPS M D2
LOAD L2 T2
CR O
C2
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 46
EE 2304 Power Electronics Laboratory Manual
CIRCUIT DIAGRAM (PARALLEL INVERTER):
V0
P1 + D R C 24V dc T1
P2 P3
P4
P5
C1
Trigger Circuit
T2
R C
L -
TABULAR COLUMN (SERIES INVERTER): RESONANCE FREQUENCY = ____________: FIRING ANGLE = __________ S.No. Input Voltage (Vi) Volts Frequency Of Firing Circuit (Hz) Output Voltage Vo (Volts)
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 47
EE 2304 Power Electronics Laboratory Manual
TABULAR COLUMN (PARALLEL INVERTER):
Output voltage Voltage (v) Time (ms) Voltage across inductor Voltage (v) Time (ms) Voltage across diode Voltage Time (v) (ms) Voltage across scr Voltage (v) Time (ms)
MODEL GRAPH (SERIES INVERTER):
T1 T2 ec1
t
ec2
eo
t
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 48
EE 2304 Power Electronics Laboratory Manual
MODEL GRAPH (PARALLEL INVERTER) : V0
VL
VSCR1
VD1
RESULT: Thus a single-phase series inverter and parallel inverter operation were studied and its output waveform were plotted.
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING, REC 49