0% found this document useful (0 votes)
230 views6 pages

Battery Size Calculator

This document provides instructions on how to calculate the size of a battery bank and inverter for an off-grid electrical system. It includes details on determining the electrical load, factors that affect battery performance like temperature and depth of discharge, and formulas for sizing the battery bank capacity and inverter power. The key specifications and calculations are listed, such as a total daily load of 100 kWh, required battery bank capacity of 60 Ah, and recommended inverter size of 150 kW.

Uploaded by

Saravanamuthu G
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
230 views6 pages

Battery Size Calculator

This document provides instructions on how to calculate the size of a battery bank and inverter for an off-grid electrical system. It includes details on determining the electrical load, factors that affect battery performance like temperature and depth of discharge, and formulas for sizing the battery bank capacity and inverter power. The key specifications and calculations are listed, such as a total daily load of 100 kWh, required battery bank capacity of 60 Ah, and recommended inverter size of 150 kW.

Uploaded by

Saravanamuthu G
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 6

CALCULATE THE SIZE OF BATTERY BANK & INVERTOR

Electrical Load Details Sr.No Equiment Name 1 No 1 Watt 100 Using Hr/Day Watt Hr./Day 1 100.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 100.0 # 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 # Watt.Hr/Day

Total Load

BATTERY BANK & INVERTOR


Battery Bank's Voltage Reaserve Day: (How many days Do you want to get Power from battery Banks) Loose Connection/Wire Loss Factor: Battery Efficiency Battery Aging: Depth of Discharge:(DOD) Battery Operating Temp: The Battery Bank Required: If You are Selecting Battery Batteries connection for Battery Bank 12 2.5 20 100 20 50 46 60.0 50 Volts DC Days % % % % Amp.Hr Amp.Hr @

Jignesh.Parmar www.jiguparmar.com [email protected]

0.2 1 0.2 0.5

volts

Type of Connection For Batteries Selection of Batteries Connection: Selection of Each Battery Voltage Number of String for Battry Bank Total Amp.Hr of Each String Total No of Battery in Each String

:Battery Bank Detail : Series-Parral Connection O.K O.K 1 Nos 50 Amp.Hr 2 Nos 50 2 Amp.Hr Nos

Total Battery Bank Amp.Hr Total Nos of Batteries in Battery Bank

Calculate Additional Future Load Effieciency of Invertor Size of Invertor

:Size of Invertor: 20 % 80 % 150 KW

CALCULATIONS: Total KW.Hr/Day Total Amp.Hr Average Load Storage Required Battery Aging Including Operating Temp Depth of Discharge

100.0 8.3 10.0 25.0 30.0 30.0 60.0

Watt.Hr/Day Amp.Hr Amp.Hr Amp.Hr Amp.Hr Amp.Hr Amp.Hr

Watt.Hr/Day