PAGE __________ OF ______________
JOB NO. ___________________________ ITEM NO. _______________
PURCH. ORDER NO. _______________ DATE ___________________
INQUIRY NO_______________________ BY _____________________
REVISION ________________________ DATE __________________
APPLICABLE TO:
FOR ___________________________________________________________________________________ UNIT ________________________________________________
SITE __________________________________________________________________________________ NO. OF PUMPS REQUIRED ___________________________
SERVICE ______________________________________________________________________________ SIZE AND TYPE _____________________________________
MANUFACTURER ______________________________________________________________________ SERIAL NO. _________________________________________
NOTE:
PROPOSAL
PURCHASE
AS BUILT
INDICATES INFORMATION TO BE COMPLETED BY THE PURCHASER
BY MANUFACTURER
7
8
NO. MOTOR DRIVEN ______________________ OTHER DRIVER TYPE ____________________________________________________________________________
PUMP ITEM NOS _________________________ PUMP ITEM NOS ________________________________________________________________________________
10
MOTOR ITEM NOS _______________________
11
MOTOR PROVIDED BY ____________________ DRIVER PROVIDED BY __________________________ GEAR PROVIDED BY __________________________
12
MOTOR MOUNTED BY ____________________ DRIVER MOUNTED BY __________________________ GEAR MOUNTED BY __________________________
13
MOTOR DATA SHEET NO. _________________ DRIVER DATA SHEET NO ________________________ GEAR DATA SHEET NO ________________________
DRIVER ITEM NOS ______________________________ GEAR ITEM NOS ______________________________
14
15
CAPACITY @ PT (m3/h):
TYPE OR NAME OF LIQUID ________________________________________
16
@ MAXIMUM VISCOSITY _________ @ MINIMUM VISCOSITY _________
PUMPING TEMPERATURE (OC):
17
DISCHARGE PRESSURE (kPa)(BARG):
NORMAL ____________ MAXIMUM _____________ MINIMUM ____________
18
MAXIMUM ___________ MINIMUM ___________
SPECIFIC GRAVITY_________ MAXIMUM _________ MINIMUM _________
19
SUCTION PRESSURE (kPa)(BARG):
SPECIFIC HEAT _________________________ Cp (kJ/kgOC)
20
MAXIMUM ___________ MINIMUM ___________
VISCOSITY (Cp) __________ MAXIMUM __________ MINIMUM__________
21
DIFFERENTIAL PRESSURE (kPa)(BARG):
CORROSIVE/EROSIVE AGENTS _________________________
22
MAXIMUM ___________ MINIMUM ___________
CHLORIDE CONCENTRATION (PPM) _____________________
23
NPSH AVAILABLE (m) _____________________________________________
24
HYDRAULIC kW __________________________________________________
25
H2S CONCENTRATION (PPM) ____________________________
LIQUID
TOXIC
FLAMMABLE
OTHER ___________
_____________________________________________________________________
26
RATED CAPACITY (m3/h)
27
NPSH REQUIRED (m)
28
RATED SPEED (RPM)
HEATED
29
DISPLACEMENT (m3/h)
ELECTRICAL AREA CLASS _______
30
VOLUMETRIC EFFICIENCY (%)
31
MECHANICAL EFFICIENCY (%)
32
kW @ MAXIMUM VISCOSITY
33
kW @ RELIEF VALVE SETTING
34
MAXIMUM ALLOWABLE SPEED (RPM)
DUST
35
MINIMUM ALLOWABLE SPEED (RPM)
OTHER ___________________________________________________________
LOCATION
INDOOR
OUTDOOR
UNHEATED
UNDER ROOF
WINTERIZATION REQD
GROUP ____
DIV ______
TROPICALIZATION REQD
SITE DATA
RANGE OF AMBIENT TEMPS: MIN/MAX ______/________OC
UNUSUAL CONDITIONS
36
FUMES
SALT ATMOSPHERE
UTILITY CONDITIONS
37
ELECTRICITY
DRIVERS
HEATING
CONTROL
SHUTDOWN
VOLTAGE
__________
__________
__________
____________
HERTZ
__________
__________
__________
____________
PHASE
__________
__________
__________
____________
RETURN
DESIGN
MAX
38
CONNECTIONS
39
SUCTION
40
DISCHARGE
41
GLAND FLUSH
COOLING WATER INLET
42
DRAINS
TEMP C
__________
MAX______ __________
____________
43
VENTS
PRESS.(kPa)(BARG)__________
MIN_______ __________
____________
44
JACKET
SIZE
ANSI RATING
FACING
POSITION
SOURCE ________________________________________________________
45
46
INSTRUMENT AIR
PUMP TYPE:
PRESS (kPa)(BARG)
47
INTERNAL GEAR
TWIN-SCREW
VANE
48
EXTERNAL GEAR
THREE-SCREW
PROGRESSING CAVITY
49
GEAR TYPE
50
SPUR
51
OTHER ___________________________________________________________
MAX
MIN
____________
____________
AP1 676 POSITIVE DISPLACEMENT PUMPS - ROTARY
GOVERNING SPECIFICATION (IF DIFFERENT) ___________________
HELICAL
REMARKS: __________________________________________________________
PAGE __________ OF ____
JOB NO. ___________________________ ITEM NO. _______________
REVISION _________________________ DATE ___________________
BY _____________________
1
2 CASING
CASING ___________________________________________________________
MAXIMUM ALLOWABLE PRESSURE_________(kPa)(BARG) @_______ C
STATOR ___________________________________________________________
HYDROSTATIC TEST PRESSURE___________ (kPa)(BARG)
END PLATES ______________________________________________________
STEAM JACKET PRESSURE________________ (kPa)(BARG) @_______OC
ROTOR(S) _________________________________________________________
ROTOR MOUNT
BETWEEN BEARINGS
OVERHUNG
VANES ____________________________________________________________
TIMING GEARS
YES
NO
SHAFT ____________________________________________________________
BEARING TYPE
RADIAL _______________
THRUST___________
SLEEVE(S) ________________________________________________________
LUBRICATION TYPE:
10
11
CONSTANT LEVEL OILERS
GLAND(S) _________________________________________________________
PUMPED FLUID
RING OIL
OIL MIST
BEARING HOUSING _______________________________________________
EXTERNAL
OIL FLOOD
GREASE
TIMING GEARS ___________________________________________________
12
LUBRICANT TYPE_________________________________________________
SPECIAL MATERIAL TESTS (2.9.1.3) ________________________________
13
MECHANICAL SEALS
LOW AMBIENT TEMP. MATERIALS TESTS (2.9.5) ____________________
14
MANUFACTURER AND MODEL _________________________________
15
MANUFACTURER CODE _______________________________________
16
API 682 SEAL FLUSH PAN _________________________________________
CERTIFICATION OF MATERIALS
17
API 682 SEAL CODE ______________________________________________
FINAL ASSEMBLY CLEARANCES
18
PACKING:
SURFACE AND SUBSURFACE EXAMINATIONS
19
LANTERN RING
MANUFACTURER AND TYPE ___________
COMPLIANCE WITH INSPECTORS CHECKLIST
NO. OF RINGS _____
RADIOGRAPHY ________________________________________________
ULTRASONIC __________________________________________________
20
21
DIRECT-COUPLED
22
COUPLING MANUFACTURER ______________________________________
V-BELT
GEAR
MAGNETIC PARTICLE __________________________________________
LIQUID PENETRANT ___________________________________________
CLEANLINESS PRIOR TO FINAL ASSEMBLY
23
24
MOTOR
25
MANUFACTURER _________________________________________________
26
TYPE ____________________________________________________________
TESTS
27
FRAME NO. ______________________________________________________
HYDROSTATIC
28
CONSTANT SPEED _______________________________________________
MECHANICAL RUN
29
VARIABLE SPEED ________________________________________________
PERFORMANCE
30
kW_______________________________ RPM __________________________
NPSH
31
VOLTS___________________________ PHASE ________________________
32
HERTZ___________________________ SERVICE FACTOR ______________
DOMESTIC
33
ENCLOSURE _____________________________________________________
OUTDOOR STORAGE MORE THAN 6 MONTHS
34
__________________________________________________________________
35
STEAM TURBINE _________________________________________________
36
OTHER (SEE SEPARATE DATA SHEETS) ___________________________
HARDNESS OF PARTS, WELDS & HEAT AFFECTED ZONES
38 NAMEPLATE UNITS
CUSTOMARY
RELIEF VALVES BY PUMP MFGR
PUMP VENDOR
SI
INTERNAL
40 PIPING FOR SEAL FURNISHED BY:
41
REQD
PUMP ______________
WIT
EXPORT
OBS
EXPORT BOXING REQD
BASE _____
BY PUMP MANUFACTURER
37
39
FURNISH PROCEDURES FOR OPTIONAL TESTS
GEAR ____
DRIVER ______
SUITABLE FOR EPOXY GROUT
EXTENDED FOR __________________________________________________
EXTERNAL
SUBSOLE PLATES BY PUMP MANUFACTURER
DRAIN-RIM
DRAIN-PAN
OTHERS
42 PIPING FOR COOLING/HEATING FURNISHED BY:
43
PUMP VENDOR
44
PROVIDE TECHNICAL DATA MANUAL
OTHERS
45 REMARKS ___________________________________________________________________________________________________________________________________
46 ______________________________________________________________________________________________________________________________________________
47 ______________________________________________________________________________________________________________________________________________
48 ______________________________________________________________________________________________________________________________________________
49 ______________________________________________________________________________________________________________________________________________
50 ______________________________________________________________________________________________________________________________________________
51
HT/API676/0506-01