Lux Calculation (Form2)
Lux Calculation (Form2)
Room Name
Requeste
Lamp
d
Luminous
Lighting
Illuminanc
Flux
Fixture Type
e
Room Dimension
Length Width
F(lm)
E(lx)
X(m)
Area
Y(m) A(m2)
Room
Illumi. Cavity
Q'ty of
Design
Light
Height RCR=
Ratio
Work
Reflector Index Maint. Utiliz. Lamp
Fixture
Height
Factor Factor N=
5H(X+Y
Height
H=
)/
EA/ Q'ty of Illumi. Q'ty of
h1-h2
(XY) Ceiling Wall Floor
FUM Lamp Result Fixture
h1(m)
h2(m)
H(m)
(%)
(%)
(%)
2.3
2.30
72.0 0.00
2.3
1.44
30
30
20
0.7
0.60 24.1
2.30
2.88
30
30
20
0.7
0.46
4.2
3.35
2.09
50
50
20
E(lx)
(set)
FL40x2 A
2850
100
6.0 12.0
32 133.0
16
7.8
8 102.0
0.7
0.57 76.0
80 315.9
40
B Ground Floor
1 Switchgear Rm
FL40x2 A
2850
300
6.0
6.0
36.0 0.85
4.2
3.35
5.58
50
50
20
0.7
0.38 14.2
12 252.7
2 Battery
FL40x2 B
2850
200
15.0
6.0
90.0 0.00
4.2
4.20
4.90
50
50
20
0.7
0.36 25.1
30 239.4
15
3 Laboratory
FL40x2 C
2850
500
6.0
6.0
36.0 0.85
2.8
1.95
3.25
70
50
20
0.7
0.41 22.0
24 545.3
12
4 Corridor
FL40x2 D
2850
200
2.0 19.0
38.0 0.00
2.8
2.80
7.74
70
50
20
0.7
0.31 12.3
14 227.9
5 Man Toilet
FL40x2 A
2850
200
4.0
3.7
14.8 0.00
2.8
2.80
7.28
70
50
20
0.7
0.36
4.1
6 291.2
2850
200
4.0
4.1
16.4 0.00
2.8
2.80
6.91
70
50
20
0.7
0.36
4.6
6 262.8
FL40x2 A
2850
200
4.0
1.9
7.6 0.00
2.8
2.80
10.87
70
50
20
0.7
0.28
2.7
4 294.0
2850
200
4.0
3.2
12.6 0.00
2.8
2.80
7.94
70
50
20
0.7
0.32
3.9
4 202.7
8 Trans Rm 1
FL40x2 A
2850
100
4.8
4.4
21.1 0.00
4.3
4.30
9.37
30
30
20
0.7
0.27
3.9
4 102.0
9 Trans Rm 1
FL40x2 A
2850
100
4.8
4.4
21.1 0.00
4.3
4.30
9.37
30
30
20
0.7
0.27
3.9
4 102.0
10 Trans Rm 1
FL40x2 A
2850
100
4.8
4.4
21.1 0.00
4.3
4.30
9.37
30
30
20
0.7
0.27
3.9
4 102.0
11 Trans Rm 1
FL40x2 A
2850
100
4.8
4.4
21.1 0.00
4.3
4.30
9.37
30
30
20
0.7
0.27
3.9
4 102.0
1 Electronic Rm 1
FL40x2 C
2850
500
12.0
7.8
93.6 0.85
3.3
2.45
2.59
70
70
20
0.7
0.44 53.3
60 562.7
30
2 Electronic Rm 2
FL40x2 C
2850
500
3.6
7.8
28.1 0.85
3.3
2.45
4.97
70
70
20
0.7
0.39 18.0
24 665.0
12
3 Control Rm
FL40x2 E
2850
800
3.3
2.45
2.04
70
70
20
0.7
0.49 ####
120 814.6
60
4 Small Rm At EE - E5 FL40x2 C
2850
500
10.0
4.0
40.0 0.85
3.3
2.45
4.29
70
70
20
0.7
0.41 24.5
30 613.5
15
6 Small Rm At EE - E3 FL40x2 D
2850
200
2.0
4.0
8.0 0.85
3.3
2.45
9.19
70
70
20
0.7
0.30
2.7
4 299.3
7 Office
FL40x2 C
2850
500
3.6
6.0
21.6 0.85
2.8
1.95
4.33
70
70
20
0.7
0.41 13.2
18 681.6
8 Telecom Rm
FL40x2 C
2850
500
3.6
6.0
21.6 0.85
3.0
2.15
4.78
70
70
20
0.7
0.35 15.5
18 581.9
9 Corridor
FL40x2 D
2850
200
27.6
2.4
66.2 0.00
2.8
2.80
6.34
70
50
20
0.7
0.37 17.9
20 222.9
10
FL40x2 E
2850
600
7.0
6.0
42.0 0.85
2.8
1.95
3.02
70
70
20
0.7
0.44 28.7
30 627.0
15
2850
500
6.0
3.7
22.2 0.85
2.8
1.95
4.26
70
70
20
0.7
0.41 13.6
16 589.5
12 Office
FL40x2 C
2850
500
6.0
3.7
22.2 0.85
2.8
1.95
4.26
70
70
20
0.7
0.41 13.6
16 589.5
13 Toilet
FL40x2 A
2850
200
6.0
3.6
21.6 0.00
2.8
2.80
6.22
70
50
20
0.7
0.39
5.6
6 216.1
14 Kitchen
FL40x2 A
2850
200
6.0
3.2
19.2 0.00
2.8
2.80
6.71
70
50
20
0.7
0.36
5.3
6 224.4
D SECOND FLOOR
1 Record Storage
2 Air Con. m/c Rm
FL40x2 A
FL40x2 A
2850
2850
200
300
2.8
3.5
2.80
3.50
4.67
2.43
70
50
50
50
20
20
0.7
0.7
0.43 8.4
0.57 57.0
C First Floor
10 Conference Rm
12 286.0
6
64 336.9 32+2
NO
Room Name
Request
Lamp
ed
Lumino
Lighting
Illuminan
Fixture Type us Flux
ce
Room Dimension
Length Width
F(lm)
E(lx)
X(m)
Y(m)
Area
A(m2)
Light
Illumi.
Work Fixtur
Height
Heigh
e
t
Heigh
H=
t
h1-h2
h1(m) h2(m)
Room
Cavity
Q'ty of
Ratio
Reflector Index Maint. Utiliz. Lamp
RCR=
Factor Factor N=
5H(X+
Y)/
EA/ Q'ty of
(XY) Ceiling Wall Floor
FUM Lamp
H(m)
(%)
(%)
(%)
Design
Illumi.
Result
Q'ty of
Fixture
E(lx)
(set)
MH400 G2 31000
200
5.95 50
50
20
28 218.3
28
2 Turbine Hall
MH400 G1 31000
200
54.0 15.0
4.69 50
50
20
21 204.3
21
MH400 G2 31000
200
36.0 21.0
6.79 50
50
20
20 218.6
20
2 Turbine Hall
MH400 G1 31000
200
36.0 15.0
5.19 50
50
20
15 213.6
15
2850
200
30.0
7.0
210.0 0.00
3.0
3.00
2.64 50
50
20
0.7
42 203.5
21
200
30.0
7.0
210.0 0.00
7.0
7.00
6.17 50
50
20
0.62 0.37
5.9
6 203.2
0.51 41.3
2850
200
30.0
7.0
210.0 0.00
3.0
3.00
2.64 50
50
20
0.7
0.51 41.3
42 203.5
21
2850
200
30.0 15.0
450.0 0.00
4.0
4.00
2.00 50
50
20
0.7
0.60 75.2
80 212.8
40
2850
50
24.0
7.0
168.0 0.00
4.0
4.00
3.69 50
50
20
0.7
0.52
8.1
22 135.9
11
7 Deaerator
3000
50
18.0
7.0
126.0
2.50
2.48
0.7
0.47
6.4
2850
200
8.0
5.0
40.0 0.00
4.0
4.00
6.50 50
50
20
0.7
FL40x2 A
3000
200
13.3
4.3
57.2 0.00
4.0
4.00
6.15 50
50
20
FL40x2 A
3000
200
7.9
2.9
22.9 0.00
4.0
4.00
9.43 50
50
50
20.0 12.0
2739
200
11.0
4.5
1 Pump House
MH400 G2 31000
200
17.8
9.0
2 Crane Yard
MH250 X 17000
50
24.0 16.0
5.21
FL40x2 B
3000
50
14.6 13.0
189.8 0.00
5.5
5.50
3000
50
12.0
7.0
84.0 0.00
4.0
X N2 CYLINDER SUNSHED
FL40x2 A
3000
50
5.0
4.0
20.0 0.00
3000
50
11.0
4.5
FL40x2 A
12
94.0
0.39 10.3
12 233.4
0.7
0.38 14.3
16 223.3
20
0.7
0.30
7.3
8 220.0
20
0.75 0.39
2.3
5 109.7
6.26 50
50
20
0.7
0.38 13.6
16 235.5
50
20
0.62 0.39
4.3
6 280.7
20
0.62 0.39
4.7
53.5
4.00
20
0.7
0.27 16.7
24
71.7
12
4.00
4.52
20
0.7
0.31
6.5
12
93.0
4.0
4.00
9.00
20
0.7
0.20
2.4
84.0
49.5 0.00
4.5
4.50
7.05
20
0.7
0.25
4.7
84.8
IV EMERGENCY DG BUILDING
1 Emergency DG Rm
FL40x2 A
6.67
VI CHLORINATION BUILDING
1 Main Rm
FL40x2 A
49.5 0.00
4.0
4.00
FL40x2 C
2850
500
4.0
4.0
16.0 0.85
2.7
1.85
4.63 80
70
20
0.7
0.40 10.0
12 598.5
2 Control Rm
FL40x2 E
2850
800
8.0
7.0
56.0 0.85
3.0
2.15
2.88 80
70
20
0.7
0.47 47.8
48 803.7
24
3 Electrical Rm
FL40x2 C
2850
300
4.0
7.0
28.0 0.85
3.0
2.15
4.22 80
70
20
0.7
0.42 10.0
12 359.1
4 Corridor
5 Battery Rm
FL40x1 D
FL40x2 B
2850
2850
200
200
8.0
7.0
2.0
4.0
16.0 0.85
28.0 0.85
2.7
4.2
1.85
3.35
5.78 80
6.58 50
70
50
20
20
0.7
0.7
0.44
0.29
6 329.2
12 248.0
3
6
3.6
9.7
NO
Room Name
Requeste
Lamp
d
Luminous
Lighting
Illuminanc
Flux
Fixture Type
e
Room Dimension
Length Width
F(lm)
E(lx)
X(m)
Area
Y(m) A(m2)
Room
Q'ty of
Illumi. Cavity
Light
Height RCR=
Ratio
Work
Reflector Index Maint. Utiliz. Lamp
Fixture
Height
Factor Factor
N=
5H(X+Y
Height
EA/
H=
)/
h1-h2
(XY) Ceiling Wall Floor
FUM
h1(m)
h2(m)
H(m)
(%)
(%)
(%)
2.3
2.30
1.44
30
30
20
0.7
0.60
72.0 0.00
2.3
2.30
2.88
30
30
20
0.7
4.2
3.35
2.09
50
50
20
Design
E(lx)
(set)
2.4
0.0
16
0.46
0.8
0.0
0.7
0.57
7.6
0.0
40
FL40x2 A
2850
10
6.0 12.0
B Ground Floor
1 Switchgear Rm
FL40x2 A
2850
30
6.0
6.0
36.0 0.85
4.2
3.35
5.58
50
50
20
0.7
0.38
1.4
0.0
2 Battery
FL40x2 B
2850
20
15.0
6.0
90.0 0.00
4.2
4.20
4.90
50
50
20
0.7
0.36
2.5
0.0
15
3 Laboratory
FL40x2 C
2850
50
6.0
6.0
36.0 0.85
2.8
1.95
3.25
70
50
20
0.7
0.41
2.2
0.0
12
4 Corridor
FL40x2 D
2850
20
2.0 19.0
38.0 0.00
2.8
2.80
7.74
70
50
20
0.7
0.31
1.2
0.0
5 Man Toilet
FL40x2 A
2850
20
4.0
3.7
14.8 0.00
2.8
2.80
7.28
70
50
20
0.7
0.36
0.4
0.0
2850
20
4.0
4.1
16.4 0.00
2.8
2.80
6.91
70
50
20
0.7
0.36
0.5
0.0
FL40x2 A
2850
20
4.0
1.9
7.6 0.00
2.8
2.80
10.87
70
50
20
0.7
0.28
0.3
0.0
2850
20
4.0
3.2
12.6 0.00
2.8
2.80
7.94
70
50
20
0.7
0.32
0.4
0.0
8 Trans Rm 1
FL40x2 A
2850
10
4.8
4.4
21.1 0.00
4.3
4.30
9.37
30
30
20
0.7
0.27
0.4
0.0
9 Trans Rm 1
FL40x2 A
2850
10
4.8
4.4
21.1 0.00
4.3
4.30
9.37
30
30
20
0.7
0.27
0.4
0.0
10 Trans Rm 1
FL40x2 A
2850
10
4.8
4.4
21.1 0.00
4.3
4.30
9.37
30
30
20
0.7
0.27
0.4
0.0
11 Trans Rm 1
FL40x2 A
2850
10
4.8
4.4
21.1 0.00
4.3
4.30
9.37
30
30
20
0.7
0.27
0.4
0.0
1 Electronic Rm 1
FL40x2 C
2850
50
12.0
7.8
93.6 0.85
3.3
2.45
2.59
70
70
20
0.7
0.44
5.3
0.0
30
2 Electronic Rm 2
FL40x2 C
2850
50
3.6
7.8
28.1 0.85
3.3
2.45
4.97
70
70
20
0.7
0.39
1.8
0.0
12
3 Control Rm
FL40x2 E
2850
400
3.3
2.45
2.04
70
70
20
0.7
0.49
58.9
0.0
60
4 Small Rm At EE - E5 FL40x2 C
2850
50
10.0
4.0
40.0 0.85
3.3
2.45
4.29
70
70
20
0.7
0.41
2.4
0.0
15
6 Small Rm At EE - E3 FL40x2 D
2850
50
2.0
4.0
8.0 0.85
3.3
2.45
9.19
70
70
20
0.7
0.30
0.7
0.0
7 Office
FL40x2 C
2850
50
3.6
6.0
21.6 0.85
2.8
1.95
4.33
70
70
20
0.7
0.41
1.3
0.0
8 Telecom Rm
FL40x2 C
2850
50
3.6
6.0
21.6 0.85
3.0
2.15
4.78
70
70
20
0.7
0.35
1.5
0.0
9 Corridor
FL40x2 D
2850
20
27.6
2.4
66.2 0.00
2.8
2.80
6.34
70
50
20
0.7
0.37
1.8
0.0
10
FL40x2 E
2850
60
7.0
6.0
42.0 0.85
2.8
1.95
3.02
70
70
20
0.7
0.44
2.9
0.0
16
2850
50
6.0
3.7
22.2 0.85
2.8
1.95
4.26
70
70
20
0.7
0.41
1.4
0.0
12 Office
FL40x2 C
2850
50
6.0
3.7
22.2 0.85
2.8
1.95
4.26
70
70
20
0.7
0.41
1.4
0.0
13 Toilet
FL40x2 A
2850
20
6.0
3.6
21.6 0.00
2.8
2.80
6.22
70
50
20
0.7
0.39
0.6
0.0
14 Kitchen
FL40x2 A
2850
20
6.0
3.2
19.2 0.00
2.8
2.80
6.71
70
50
20
0.7
0.36
0.5
0.0
D SECOND FLOOR
1 Record Storage
2 Air Con. m/c Rm
FL40x2 A
FL40x2 A
2850
2850
20
30
2.8
3.5
2.80
3.50
4.67
2.43
70
50
50
50
20
20
0.7
0.7
0.43
0.57
0.8
5.7
0.0
0.0
6
32+2
C First Floor
10 Conference Rm
NO
Room Name
Requeste
Lamp
d
Luminous
Lighting
Illuminanc
Flux
Fixture Type
e
E(lx)
Area
A(m2)
h1(m)
Room Dimension
Length Width
F(lm)
Room
Q'ty
Design
Illumi. Cavity
of
Light
Utiliz.
Height RCR=
Ratio
Lamp
Work
Reflector Index Maint.
Fixture
Facto
Height
Factor
5H(X+Y
N=
Height
r
H=
)/
EA/ Q'ty of Illumi. Q'ty of
h1-h2
(XY) Ceiling Wall Floor
FUM Lamp Result Fixture
X(m)
Y(m)
h2(m)
H(m)
(%)
(%)
(%)
E(lx)
(set)
2850
300
4.0
4.0
16.0 0.85
2.7
1.85
4.63 80
70
20
0.7 0.40
6.0
8 399.0
2 Control Rm
FL40x2 E
2850
500
8.0
7.0
56.0 0.85
3.0
2.15
2.88 80
70
20
32 535.8
16
3 Electrical Rm
FL40x2 C
2850
300
4.0
7.0
28.0 0.85
3.0
2.15
4.22 80
70
20
12 359.1
4 Corridor
FL40x1 D
2850
200
8.0
2.0
16.0 0.85
2.7
1.85
5.78 80
70
20
0.7 0.44
3.6
4 219.5
5 Battery Rm
FL40x2 B
2850
200
7.0
4.0
28.0 0.85
4.2
3.35
6.58 50
50
20
0.7 0.29
9.7
12 248.0
6 Man Toilet
FL40x1 A
2850
200
4.0
2.0
8.0 0.85
2.7
1.85
6.94 70
50
20
0.7 0.36
2.2
4 359.1
7 Woman Toilet
FL40x1 A
2850
200
2.0
2.0
4.0 0.85
2.7
1.85
9.25 70
50
20
0.7 0.30
1.3
2 299.3
8 Porch
FL40x1 A
2850
50
2.0
6.0
12.0 0.00
4.2
4.20
14.00 30
20
0.7 0.19
1.6
2 63.2
2850
300
5.1
2.6
13.3 0.85
3.0
2.15
6.24 50
50
20
0.7 0.40
5.0
6 361.1
2850
300
2.2
2.4
5.3 0.00
3.0
3.00
13.07 50
50
20
0.7 0.40
2.0
2 302.3
NO
Room Name
Request
Lamp
ed
Lumino
Lighting
Illuminan
Fixture Type us Flux
ce
Room Dimension
Length Width
F(lm)
MH400 G1 31000
E(lx)
X(m)
200
Y(m)
Area
A(m2)
Room
Illumi.
Cavity
Q'ty of
Light
Ratio
Work Fixtur Height RCR=
Reflector Index Maint. Utiliz. Lamp
Height
e
Factor Factor N=
5H(X+
Height H =
Y)/
EA/ Q'ty of
h1-h2
(XY) Ceiling Wall Floor
FUM Lamp
h1(m) h2(m)
H(m)
Design
Illumi.
Result
Q'ty of
Fixture
E(lx)
(set)
(%)
(%)
(%)
5.95 50
50
28 218.3
28
200
54.0 15.0
4.69 50
50
21 199.3
21
MH400 G2 31000
200
36.0 21.0
6.79 50
50
20 218.6
20
2 Turbine Hall
MH400 G1 31000
200
36.0 15.0
5.19 50
50
15 213.6
15
2850
200
30.0
7.0
210.0 0.00
3.0
3.00
2.64 50
50
20
42 203.5
21
200
30.0
7.0
210.0 0.00
7.0
7.00
6.17 50
50
20 0.62 0.36
6.1
6 197.7
0.7
0.51 41.3
2850
200
30.0
7.0
210.0 0.00
3.0
3.00
2.64 50
50
20
0.7
0.51 41.3
42 203.5
21
2850
200
30.0 15.0
450.0 0.00
4.0
4.00
2.00 50
50
20
0.7
0.59 76.5
72 188.3
36
2850
50
24.0
7.0
168.0 0.00
4.0
4.00
3.69 50
50
20
0.7
0.52
8.1
22 135.9
11
7 Deaerator
3000
50
18.0
7.0
126.0
2.50
2.48
0.7
0.47
6.4
FL40x2 A
12
94.0
NO
LOCAL
PANEL
NAME
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
DB - 1
DB - 2
DB - 3
DB - 4
DB - 5
DB - 6
DB - 7
DB - 8
DB - 9
DB - 10
SPARE
SPARE
SPARE
SPARE
SPACE
SPACE
380
380
380
380
380
380
380
380
380
380
TOTAL
TOTAL DEMAND (%)
GRAND TOTAL
53.79
21.03
#####
22.00
#####
33.25
#####
45.50
29.50
33.50
#####
#####
#####
#####
#####
#####
#####
#####
#####
#####
53.79
21.03
#####
22.00
#####
33.25
#####
45.50
29.50
33.50
81.82
31.99
#####
33.47
#####
50.58
#####
69.21
44.87
50.96
MAX. V/D
(%)
2.00
2.00
2.00
6.00
6.00
6.00
4.00
4.00
2.00
6.00
(V)
7.60
7.60
7.60
22.80
22.80
22.80
15.20
15.20
7.60
22.80
CABLE
LENGTH
MIN.
CABLE
SIZE
(M)
(Sqmm)
30
40
52
330
220
220
122
122
66
502
5.75
3.00
36.01
8.62
29.91
8.69
28.58
9.89
6.94
19.97
DESIGN
SIZE
CABLE (sqmm) V.D. (V) V.D. (%) MAX A.C.
4C 4C 4C 4C 4C 4C 4C 4C 4C 4C -
35
35
240
35
150
35
150
50
35
100
1.25
0.65
1.14
5.62
4.55
5.66
2.90
3.01
1.51
4.55
0.003
0.002
0.003
0.015
0.012
0.015
0.008
0.008
0.004
0.012
ELCB
121 A 100 AT
121 A 75 AT
445 A 400 AT
121 A 50 AT
319 A 250 AT
121 A 75 AT
319 A 300 AT
184 A 100 AT
121 A 75 AT
121 A 75 AT
Not correct
#####
#####
#####
1,032.75
1,032.75
REMARK
1 ) Total capacity ( KVA) = Total capacity ( Kw) / Power factor (0.8)
2 ) Max. V/D ( Maximum voltage drop ): JCS - 168 - E - 95 ( Japanese Cable Makers' Association Standard )
Cable length < 60m: System voltage x 2%
Cable length > 60m but < 120m: System voltage x 4%
Cable length > 120m but < 200m: System voltage x 5%
Cable length > 200m: System voltage x 6%
3 ) MIN C/S : Minimum cable size
4 ) MAX A/C ( maximum allomance current) = Current ratings of cable x 88% ( Refere to Manufacturer's Technical data )
NO
Room Name
Requeste
Lamp
d
Luminou
Lighting
Illuminanc
Fixture Type s Flux
e
Room Dimension
Length Width
F(lm)
E(lx)
X(m)
2850
200
2.2
Light
Work
Fixture
Height
Height
Area
Y(m) A(m2)
h1(m)
Room
Cavity
Utiliz.
Ratio
Reflector Index Maint.
RCR=
Facto
Factor
5H(X+Y
r
H=
)/
h1-h2
(XY) Ceiling Wall Floor
Illumi.
Height
h2(m)
H(m)
(%)
(%)
(%)
3.0
3.00
13.07 50
50
20
SEPTIC TANK
1 Septic tank control house FL40x2 A
2.4
5.3 0.00
0.7 0.40
Q'ty of
Design
Lamp
N=
EA/ Q'ty of Illumi. Q'ty of
FUM Lamp Result Fixture
N
1.3
E(lx)
2 302.3
(set)