3
Weld Strength Reduction Factor [fr1]:
= min( 1, Sn/S )
= min( 1, 137.9/137.9 )
= 1.000
Weld Strength Reduction Factor [fr2]:
= min( 1, Sn/S )
= min( 1, 137.9/137.9 )
= 1.000
Weld Strength Reduction Factor [fr3]:
= min( fr2, fr4 )
= min( 1.0 , 1.0 )
= 1.000
Results of Nozzle Reinforcement Area Calculations:
AREA AVAILABLE, A1 to A5
Design
Area Required
Ar
20.703
Area in Shell
A1
8.508
Area in Nozzle Wall
A2
8.900
Area in Inward Nozzle
A3
29.120
Area in Welds
A41+A42+A43
2.416
Area in Element
A5
0.000
Area in Hub
A6
21.867
TOTAL AREA AVAILABLE
Atot
70.811
External
13.755
1.702
8.558
29.120
2.416
0.000
21.867
63.663
Mapnc
30.983
0.000
11.044
34.475
2.880
0.000
23.670
72.069
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
The MAP(nc) Case Governs the Analysis.
Nozzle Angle Used in Area Calculations
68.53
Degs.
The area available without a pad is Sufficient.
Area
=
=
=
Required [A]:
( d * tr*F + 2 * tn * tr*F * (1-fr1) ) UG-37(c)
(157.2772*19.6998*1.0+2*35.0000*19.6998*1.0*(1-1.00))
30.983 cm2
Reinforcement Areas per Figure UG-37.1
Area Available in Shell [A1]:
= d( E1*t - F*tr ) - 2 * tn( E1*t - F*tr ) * ( 1 - fr1 )
= 157.277 ( 1.00 * 19.7000 - 1.0 * 19.700 ) - 2 * 35.000
( 1.00 * 19.7000 - 1.0 * 19.6998 ) * ( 1 - 1.000 )
= 0.000 cm2
Area Available in Nozzle Projecting Outward [A2]:
= ( 2 * tlnp ) * ( tn - trn ) * fr2/sin( alpha3 )
= ( 2 * 49.25 ) * ( 10.97 - 0.48 ) * 1.0000/sin( 69.3 )
= 11.044 cm2
Note: See Appendix L, L-7.7.7(b) for more information.
Area Available in Inward Nozzle [A3]:
= 2 * ti * min( h, Tl, 2.5 * ti) * fr2
= 2 * 32.0000 * ( 45.5000 ) * 1.0000
= 34.475 cm2
Area Available in Inward Weld + Outward Weld [A41 + A43]:
= Wo * fr2 + ( Wi-can/0.707 ) * fr2
= 12.0000 * 1.0000 + ( 12.0000 ) * 1.0000
= 2.880 cm2
Area Available in the Hub Section [A6]:
= ( 2 * min(Tlnp,ho,Hubht)) * (Hubtk - tn) * fr2
= ( 2 * min(45.5 ,290.0 ,120.0 )) * (35.0 - 11.0 ) * 1.000 )
= 23.670 cm2
Nozzle Junction Minimum Design Metal Temperature (MDMT) Calculations:
MDMT of the Nozzle Neck to Flange Weld,
Curve: B