This document summarizes the results of calculations to determine the required and available reinforcement areas for a nozzle attachment. The required area is 30.983 cm2 based on the design equations. The available areas are calculated in various sections of the nozzle, including the shell, nozzle wall, inward nozzle, welds, element, and hub. The total available area of 72.069 cm2 exceeds the required area. Therefore, the reinforcement area is sufficient without needing an additional pad.

Uploaded by

whngomj
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
105 views1 page

Nozzle Cal - 03

This document summarizes the results of calculations to determine the required and available reinforcement areas for a nozzle attachment. The required area is 30.983 cm2 based on the design equations. The available areas are calculated in various sections of the nozzle, including the shell, nozzle wall, inward nozzle, welds, element, and hub. The total available area of 72.069 cm2 exceeds the required area. Therefore, the reinforcement area is sufficient without needing an additional pad.

Uploaded by

whngomj
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

3

Weld Strength Reduction Factor [fr1]:


= min( 1, Sn/S )
= min( 1, 137.9/137.9 )
= 1.000
Weld Strength Reduction Factor [fr2]:
= min( 1, Sn/S )
= min( 1, 137.9/137.9 )
= 1.000
Weld Strength Reduction Factor [fr3]:
= min( fr2, fr4 )
= min( 1.0 , 1.0 )
= 1.000
Results of Nozzle Reinforcement Area Calculations:
AREA AVAILABLE, A1 to A5
Design
Area Required
Ar
20.703
Area in Shell
A1
8.508
Area in Nozzle Wall
A2
8.900
Area in Inward Nozzle
A3
29.120
Area in Welds
A41+A42+A43
2.416
Area in Element
A5
0.000
Area in Hub
A6
21.867
TOTAL AREA AVAILABLE
Atot
70.811

External
13.755
1.702
8.558
29.120
2.416
0.000
21.867
63.663

Mapnc
30.983
0.000
11.044
34.475
2.880
0.000
23.670
72.069

cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2

The MAP(nc) Case Governs the Analysis.


Nozzle Angle Used in Area Calculations

68.53

Degs.

The area available without a pad is Sufficient.


Area
=
=
=

Required [A]:
( d * tr*F + 2 * tn * tr*F * (1-fr1) ) UG-37(c)
(157.2772*19.6998*1.0+2*35.0000*19.6998*1.0*(1-1.00))
30.983 cm2

Reinforcement Areas per Figure UG-37.1


Area Available in Shell [A1]:
= d( E1*t - F*tr ) - 2 * tn( E1*t - F*tr ) * ( 1 - fr1 )
= 157.277 ( 1.00 * 19.7000 - 1.0 * 19.700 ) - 2 * 35.000
( 1.00 * 19.7000 - 1.0 * 19.6998 ) * ( 1 - 1.000 )
= 0.000 cm2
Area Available in Nozzle Projecting Outward [A2]:
= ( 2 * tlnp ) * ( tn - trn ) * fr2/sin( alpha3 )
= ( 2 * 49.25 ) * ( 10.97 - 0.48 ) * 1.0000/sin( 69.3 )
= 11.044 cm2
Note: See Appendix L, L-7.7.7(b) for more information.
Area Available in Inward Nozzle [A3]:
= 2 * ti * min( h, Tl, 2.5 * ti) * fr2
= 2 * 32.0000 * ( 45.5000 ) * 1.0000
= 34.475 cm2
Area Available in Inward Weld + Outward Weld [A41 + A43]:
= Wo * fr2 + ( Wi-can/0.707 ) * fr2
= 12.0000 * 1.0000 + ( 12.0000 ) * 1.0000
= 2.880 cm2
Area Available in the Hub Section [A6]:
= ( 2 * min(Tlnp,ho,Hubht)) * (Hubtk - tn) * fr2
= ( 2 * min(45.5 ,290.0 ,120.0 )) * (35.0 - 11.0 ) * 1.000 )
= 23.670 cm2
Nozzle Junction Minimum Design Metal Temperature (MDMT) Calculations:
MDMT of the Nozzle Neck to Flange Weld,

Curve: B