EFFECTIVE LENGTH OF R.C.
BEAMS & COLUMNS AS PER IS:456-2000,
Upper Col.
Y axis
UC
BtX2
BtY1
BtY2
BtX1
Framing
Beams
x
X
Column
X axis
y
BbX2
BbY2
BbY1
BbX1
L
Lower Col.
PLAN
ELEVATION
Column along X-X axis is =
Column along Y-Y axis is =
INPUT Details of Columns:
Column
Concrete
Mark
Grade, M
Column C
20
Column LC
30
Column UC
15
INPUT
Beam
Mk
BtX1
BtX2
BbX1
BbX2
BtY1
BtY2
BbY1
BbY2
No Sway
Sway
Rectangular Column
x (m)
y(m)
0.300
0.500
N/A
N/A
0.300
0.450
Circular Column
Dia (m) Length (m)
N/A
4.000
0.600
4.500
N/A
3.500
Details of Beams:
Concrete
Grade, M
25
25
30
30
20
25
30
30
Beam Size
Breadth(m)
Depth(m)
0.300
0.300
0.300
0.300
0.250
0.250
0.300
0.300
0.450
0.450
0.500
0.500
0.450
0.450
0.500
0.500
Beam
Length(m)
4.000
5.000
4.000
5.000
3.500
4.500
3.500
4.500
Column can be rectangular
or circular
Column Moment of Inertia (m4)
Ixx
Iyy
Mark
Column C
0.00313
0.00113
Column LC
0.00636
0.00636
Column UC
0.00228
0.00101
Flexural Stiffness
Kc-xx
Kc-yy
17469.29
38716.23
12604.49
Moment of Inertia(m )
Flexural Stiffness
Kb
0.002278
0.002278
0.003125
0.003125
0.001898
0.001898
0.003125
0.003125
7119.15
5695.32
10697.71
8558.17
18193.01
15820.32
36677.85
28527.22
6288.95
38716.2
5602.00
Frame along X-X axis - No Sway Frame
Factor b1x:
= (6288.95+5602) / (6288.95+5602+7119.15+5695.32)
=
0.4813
Factor b2x:
= (6288.95+38716.23) / (6288.95+38716.23+10697.71+8558.17)
Eff. Length Factor,
0.7003
Kx =
0.73209
Effective Length along X-X axis =
0.73209 x 4 =
2.929 m
Frame along Y-Y axis - Sway Frame
Factor b1y:
= (17469.29+12604.49) / (17469.29+12604.49+18193.01+15820.32)
=
0.4693
Factor b2y:
= (17469.29+38716.23) / (17469.29+38716.23+36677.85+28527.22)
=
0.4628
Eff. Length Factor,
Ky =
Effective Length along Y-Y axis =
1.4049
1.4049 x 4 =
5.62 m
mn can be rectangular
10697.71+8558.17)
+28527.22)