0% found this document useful (0 votes)
100 views1 page

D. 33 KV and 11 KV Structures:: Beam For 33 KV 5.4 (Width) Beam For 11 KV 4.6 (Width)

This document provides information on constructing substations, including: 1. It lists different types of structures used in 33kV and 11kV substations along with their heights. 2. It provides a table with equipment structures used in 220kV, 132kV, 33kV and 11kV substations and their types. 3. It describes the process of setting foundation bolts or stubs, leveling and grouting structures, which involves placing the template or assembled structure on foundations, leveling and centering it, and grouting to prevent displacement during concrete pouring.

Uploaded by

man98_greyhoundz
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
100 views1 page

D. 33 KV and 11 KV Structures:: Beam For 33 KV 5.4 (Width) Beam For 11 KV 4.6 (Width)

This document provides information on constructing substations, including: 1. It lists different types of structures used in 33kV and 11kV substations along with their heights. 2. It provides a table with equipment structures used in 220kV, 132kV, 33kV and 11kV substations and their types. 3. It describes the process of setting foundation bolts or stubs, leveling and grouting structures, which involves placing the template or assembled structure on foundations, leveling and centering it, and grouting to prevent displacement during concrete pouring.

Uploaded by

man98_greyhoundz
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

44

Construction Manual for Sub Stations

Sl. No. D. 1. 2. 3. 4. 5. E.

Name of Structure

Type of Structure

Height of Column / Height of Conductor (Meters)

33 kV and 11 kV Structures: X Y Z GF 5.4 GF 4.6

Peak Column Extension Beam for 33 kV Beam for 11 kV

1.5 5.5 / 5.5 3.0 5.4 (Width) 4.6 (Width)

Equipment Structures: 1. AO1 2. AO1 (T) 3. AO3 4. AO4 5. AO5 6. BO1 7. BO1 (T) 8. X 15 9. X 15 (T)

10. CT Structure 11. PI Structure

220 kV Isolators 220 kV Tandem Isolators 220 kV CT 220 kV CVT 220 kV LA & 132 kV CT, CVT / PT, LA 132 kV Isolator 132 kV Tandem Isolator 33 kV & 11kV Isolators 33 kV & 11kV Tandem Isolators 33 kV & 11kV CT, PT 220 kV, 132kV, 33 kV & 11 kV PI

------------

3.0 3.1

SETTING OF STUB / FOUNDATION BOLTS, LEVELLING AND GROUTING: In case of structures with foundation bolts, the template, along with the foundation bolts tightened on it with nuts on both sides, shall be placed on the foundation. The length of the foundation bolts above the template shall be sufficient so that all parts of the base plate assembly of the structure, washers, nuts and lock nuts can be tightened fully and 2 3 threads are left above the lock nut. The template is levelled & centered with reference to its location on the foundation. The foundation bolts shall thereafter be grouted ensuring that there is no displacement during the placing of the concrete and use of vibrator. In case of structures with stubs, the template with stubs shall be placed on the foundation. In case of structures in which the lowest member is used as a stub, the assembled lower part of the structure is placed on the foundation. This is levelled & centered with reference to its location on the foundation. The stubs / lowest member shall thereafter be grouted ensuring that there is no displacement during the placing of the concrete and use of vibrator. While levelling and centering the structure / template, the following points should be checked: