International Limited: Certificate of Visual Examination and Mpi

This document is a certificate of visual examination and MPI test for a pair of 1000-ton elevator links. The certificate provides details of the examination including the date, examiner's qualifications, equipment details, test procedures used, parts examined, and results. The examination found no defects and deemed the equipment fit for use as of the examination date.

Uploaded by

Michael Okwuwa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
182 views1 page

International Limited: Certificate of Visual Examination and Mpi

This document is a certificate of visual examination and MPI test for a pair of 1000-ton elevator links. The certificate provides details of the examination including the date, examiner's qualifications, equipment details, test procedures used, parts examined, and results. The examination found no defects and deemed the equipment fit for use as of the examination date.

Uploaded by

Michael Okwuwa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

JC International Limited

RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998 Factories Act CAP. 126 L.F.N 1990

Certificate No. 134549 Identification Number

Date of Examination 01/12/2013 Qty

Examiner JAPHET OMEFE

Qualifications FMLP, LEEA, NDT LEVEL II MT, ET, PT & UT

Description of Equipment A PAIR OF ELEVATOR LINK

JRB10B, JRB10A

A Pair of 1000tonnes Elevator Link

Date of next Examination: 30/05/2014


LOCATION: SKATE DECK
SPECIFICATION : ASTM E 1444, API RP 8B MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Critical load bearing area. RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Jack Ryan Transocean Support Services We hereby certify that on 01/12/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination
Revision No: R01 Effective Date: 29th August 2013

Name of Inspector: JAPHET OMEFE Conducting: Examination only