Thdi LV

This document contains data on harmonic currents for different devices. It lists the harmonic order, percentage of total distorting current, absolute current in amps, and contribution to total harmonic distortion index for various devices including LRF GE11E10+MCSO1, CCM HC11E10+MCSO1, CCM HC11E10+MCSO2, and SHREDDER GB31E10+DRM01. The highest total harmonic distortion was found for the SHREDDER GB31E10+DRM01 at 1,391 amps and 0.266 THDI.

Uploaded by

shaikhsajid242
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
118 views2 pages

Thdi LV

This document contains data on harmonic currents for different devices. It lists the harmonic order, percentage of total distorting current, absolute current in amps, and contribution to total harmonic distortion index for various devices including LRF GE11E10+MCSO1, CCM HC11E10+MCSO1, CCM HC11E10+MCSO2, and SHREDDER GB31E10+DRM01. The highest total harmonic distortion was found for the SHREDDER GB31E10+DRM01 at 1,391 amps and 0.266 THDI.

Uploaded by

shaikhsajid242
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

Harmonic 'I' available at Low Voltage

LRF GE11E10+MCSO1
Harmonic Order
5
7
11
13
17
19
23
25

Total Absorbed
Distorting Current (A)
Harmonic Current %
45.80%
21.70%
7.60%
4.60%
3.40%
1.90%
1.90%
1.10%
51.65%

53
Amps Sqrt
THDI
24.274
0.209764
11.501
0.047089
4.028
0.005776
2.438
0.002116
1.802
0.001156
1.007
0.000361
1.007
0.000361
0.583
0.000121
46.64
0.266744

CCM HC11E10+MCSO1
Harmonic Order
5
7
11
13
17
19
23
25

Total Absorbed
Distorting Current (A)
Harmonic Current %
45.80%
21.70%
7.60%
4.60%
3.40%
1.90%
1.90%
1.10%
51.65%

34
Amps Sqrt
THDI
15.572
0.209764
7.378
0.047089
2.584
0.005776
1.564
0.002116
1.156
0.001156
0.646
0.000361
0.646
0.000361
0.374
0.000121
29.92
0.266744

CCM HC11E10+MCSO2
Harmonic Order
5
7
11
13
17
19
23
25

Total Absorbed
Distorting Current (A)
Harmonic Current %
45.80%
21.70%
7.60%
4.60%
3.40%
1.90%
1.90%
1.10%
51.65%

127
Amps Sqrt
THDI
58.166
0.209764
27.559
0.047089
9.652
0.005776
5.842
0.002116
4.318
0.001156
2.413
0.000361
2.413
0.000361
1.397
0.000121
0.266744
111.76

SHREDDER GB31E10+DRM01
Harmonic Order
5
7
11
13
17

Total Absorbed
Distorting Current (A)
Harmonic Current %
45.80%
21.70%
7.60%
4.60%
3.40%

1581
THDI
724.098
343.077
120.156
72.726
53.754

Amps Sqrt
0.209764
0.047089
0.005776
0.002116
0.001156

19
23
25

1.90%
1.90%
1.10%
51.65%

30.039
30.039
17.391
1391.28

0.000361
0.000361
0.000121
0.266744