L.S.A.

1. Lifebuoy outer dia  800mm


inner dia  400mm
2. Life jacket/Lifebuoy test - 14.5 kg iron in fresh water for 24 hrs.
3. Hand flare in lifeboat/liferaft - 06 nos.
4. Lifebuoy with life line - 02 nos.
5. Lifebuoy self igniting light - ½ of total no. L/B
6. Rocket Parachute flare in Bridge - 12 nos.
7. MOB Lifebuoy weight - 4.0 kg
8. Lifebuoy drop test - 30 m
9. Lifebuoy grab line - dia 9.5mm, length 4 X outer dia
10. Intensity & period of light - Lifebuoy light =  2 cd for 2 hrs
Lifejacket light =  0.75 cd for 8 hrs
Lifeboat/Liferaft light =  4.3 cd for 12 hrs
Hand flare =  15000 cd for 1 min.
Rocket parachute flare =  30000 for 40 sec
11. Rocket parachute flare in L/boat - 04 nos.
12. Height of Rocket parachute flare fire - 300 m
13. Length of Rescue quit - 30 m
14. HRU activated - under 4 m of water
15. Withstand time of L/jacket, L/buoy - 24 hrs
16. Test of L/jacket - 5% of buoyancy lost after 24 hrs.
17. Lifeboat fall change - after 60 months
18. Line throwing apparatus - 01 no. with 04 rockets
19. L/jacket will be worn - over immersion suit
20. L/jacket drop test - 4.5 m
21. Flashing criteria - 50 ≈ 70 flashes per minute
22. MOB smoke duration - 15 min.
F.F.A.
23. Fireman’s outfit - at least 2 nos.
for tanker 4 nos.
inside dia - 64mm
24. International shore connection - outer dia -178mm
bolt circle dia - 132mm
slots in flange - 4 holes 19mm dia
equidistantly
flange thickness - 14.5mm min m
bolts & nuts - 4 nos, D-16mm, L-50mm
25. Portable fire extinguisher capacity - 9ltr ≈ 13.5ltr
26. No. of portable fire extinguisher over 1000 GT vessel - at least 5 nos.
27. B.A. set - at least 02 nos.
PILOT LADDER
28. Pilot ladder specification - (a) Every step of a pilot ladder shall be not less
than 480 millimetres long, 115 millimetres wide and 25 millimetres deep, excluding
any non-slip device;
(b) Step of a pilot ladder shall be equally spaced not
less than 300 millimetres or more than 380 millimetres from the next step;
(c) Every pilot ladder shall have an arrangement of two
uncovered manilla side ropes, each of which is not less than 60 millimetres in
circumference (  18mm in dia) and has no joints or splices below the top step
(d) Two man-ropes that are properly secured to the ship
and not less than 65 millimetres in circumference ((  28mm in dia), and a safety
line shall be kept close to the pilot ladder
(e) Spreader that are not less than 1.80 metres long
shall be fitted to the pilot ladder so that
(f) The lowest spreader is attached in line with the fifth
step from the bottom;
(g) The spreader are not more than nine steps apart.
29. Height of pilot ladder - max m 9
min m 1.5 m
R.O.R
30. COLREG enforce - 15th July 1977
31. Exemption - range of light - 4 years
colour of light - 4 years
repositioning of light as a conversion from Imperial to metric
unit - permanent
masthead light in vessel <150m - permanent
masthead light in vessel >150m - 9 years
vertical repositioning of masthead light - 9 years
sidelights - 9 years
sound signal appliances - 9 years
all round lights - permanent
32. Two masthead lights - no specified length
33. Black ball dia  0.6 m
34. Cylinder dia  0.6 m
35. Height of masthead light in vessel L 12m ≈ 20m - 2.5 m above gunwale
36. Length of cylinder - 2 X dia of cylinder
STABILITY
37. GM on intact stability - 0.15 m for general
0.05 m for timber
0.30 m for bulk
m
38. Max righting lever (GZ) shall occur - heel not less than 30 
30 
39. The Righting lever (GZ) shall be at least 0.20 m at an angle of heel ≥
MARPOL, SOLAS, LOAD LINE & OTHERS
40. Requirement of Oil record book - tanker 150 GT ; other vessel 400 GT
41. Boat Drill - at least once in month
42. Master list preparation - before proceeding to sea.
43. Garbage regulation out of special area - 3, 12, 25 miles
44. Safe manning Document - SOLAS
45. Watch keeping rest hour - 10 hrs daily
46. Crew Management - ILO
47. GMDSS 2 way radio over 500 GT vessel - 03 nos.
48. Load line certificate is applicable -  25m of vessel
49. PSC inspector will check - SOLAS, LL, MARPOL, ALL
50. Comminuted food waste - special area = 12 miles
out side special area = 3 miles
51. Safety information stamped by - MMD

You might also like