We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 2
L.S.A.
1. Lifebuoy outer dia 800mm
inner dia 400mm 2. Life jacket/Lifebuoy test - 14.5 kg iron in fresh water for 24 hrs. 3. Hand flare in lifeboat/liferaft - 06 nos. 4. Lifebuoy with life line - 02 nos. 5. Lifebuoy self igniting light - ½ of total no. L/B 6. Rocket Parachute flare in Bridge - 12 nos. 7. MOB Lifebuoy weight - 4.0 kg 8. Lifebuoy drop test - 30 m 9. Lifebuoy grab line - dia 9.5mm, length 4 X outer dia 10. Intensity & period of light - Lifebuoy light = 2 cd for 2 hrs Lifejacket light = 0.75 cd for 8 hrs Lifeboat/Liferaft light = 4.3 cd for 12 hrs Hand flare = 15000 cd for 1 min. Rocket parachute flare = 30000 for 40 sec 11. Rocket parachute flare in L/boat - 04 nos. 12. Height of Rocket parachute flare fire - 300 m 13. Length of Rescue quit - 30 m 14. HRU activated - under 4 m of water 15. Withstand time of L/jacket, L/buoy - 24 hrs 16. Test of L/jacket - 5% of buoyancy lost after 24 hrs. 17. Lifeboat fall change - after 60 months 18. Line throwing apparatus - 01 no. with 04 rockets 19. L/jacket will be worn - over immersion suit 20. L/jacket drop test - 4.5 m 21. Flashing criteria - 50 ≈ 70 flashes per minute 22. MOB smoke duration - 15 min. F.F.A. 23. Fireman’s outfit - at least 2 nos. for tanker 4 nos. inside dia - 64mm 24. International shore connection - outer dia -178mm bolt circle dia - 132mm slots in flange - 4 holes 19mm dia equidistantly flange thickness - 14.5mm min m bolts & nuts - 4 nos, D-16mm, L-50mm 25. Portable fire extinguisher capacity - 9ltr ≈ 13.5ltr 26. No. of portable fire extinguisher over 1000 GT vessel - at least 5 nos. 27. B.A. set - at least 02 nos. PILOT LADDER 28. Pilot ladder specification - (a) Every step of a pilot ladder shall be not less than 480 millimetres long, 115 millimetres wide and 25 millimetres deep, excluding any non-slip device; (b) Step of a pilot ladder shall be equally spaced not less than 300 millimetres or more than 380 millimetres from the next step; (c) Every pilot ladder shall have an arrangement of two uncovered manilla side ropes, each of which is not less than 60 millimetres in circumference ( 18mm in dia) and has no joints or splices below the top step (d) Two man-ropes that are properly secured to the ship and not less than 65 millimetres in circumference (( 28mm in dia), and a safety line shall be kept close to the pilot ladder (e) Spreader that are not less than 1.80 metres long shall be fitted to the pilot ladder so that (f) The lowest spreader is attached in line with the fifth step from the bottom; (g) The spreader are not more than nine steps apart. 29. Height of pilot ladder - max m 9 min m 1.5 m R.O.R 30. COLREG enforce - 15th July 1977 31. Exemption - range of light - 4 years colour of light - 4 years repositioning of light as a conversion from Imperial to metric unit - permanent masthead light in vessel <150m - permanent masthead light in vessel >150m - 9 years vertical repositioning of masthead light - 9 years sidelights - 9 years sound signal appliances - 9 years all round lights - permanent 32. Two masthead lights - no specified length 33. Black ball dia 0.6 m 34. Cylinder dia 0.6 m 35. Height of masthead light in vessel L 12m ≈ 20m - 2.5 m above gunwale 36. Length of cylinder - 2 X dia of cylinder STABILITY 37. GM on intact stability - 0.15 m for general 0.05 m for timber 0.30 m for bulk m 38. Max righting lever (GZ) shall occur - heel not less than 30 30 39. The Righting lever (GZ) shall be at least 0.20 m at an angle of heel ≥ MARPOL, SOLAS, LOAD LINE & OTHERS 40. Requirement of Oil record book - tanker 150 GT ; other vessel 400 GT 41. Boat Drill - at least once in month 42. Master list preparation - before proceeding to sea. 43. Garbage regulation out of special area - 3, 12, 25 miles 44. Safe manning Document - SOLAS 45. Watch keeping rest hour - 10 hrs daily 46. Crew Management - ILO 47. GMDSS 2 way radio over 500 GT vessel - 03 nos. 48. Load line certificate is applicable - 25m of vessel 49. PSC inspector will check - SOLAS, LL, MARPOL, ALL 50. Comminuted food waste - special area = 12 miles out side special area = 3 miles 51. Safety information stamped by - MMD