0% found this document useful (0 votes)
87 views25 pages

Check Punching of Column - Working

This document summarizes the check punching shear calculations for a concrete column according to ECP 2007. It provides the material properties, load values, geometry dimensions, and calculation of punching stress and strength. The results show that for the given parameters the punching stress is less than the punching strength capacity of the concrete, indicating safe design. Modifications to the wall thickness, column head size, or adding a drop panel are suggested to increase capacity if needed.

Uploaded by

KhaledMostafa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
87 views25 pages

Check Punching of Column - Working

This document summarizes the check punching shear calculations for a concrete column according to ECP 2007. It provides the material properties, load values, geometry dimensions, and calculation of punching stress and strength. The results show that for the given parameters the punching stress is less than the punching strength capacity of the concrete, indicating safe design. Modifications to the wall thickness, column head size, or adding a drop panel are suggested to increase capacity if needed.

Uploaded by

KhaledMostafa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 25

CHECK PUCHING SHEAR

ACCORDINNG TO ECP 2007


(ULTIMATE)

fcu=
25
WALL LOAD =

n/mm^2
2

ts =

0.2

C=

25

KN/M^2

F.c =

1.5

KN/M^2

L.L=
Wsu =
R=

2.5
9
598.5

KN/M^2
KN/M^2
KN

bo=
A=
qup =
QUP=
qcup =

2720
MM
0.4224
M
594.698
KN
1.39686 n/mm^2
1.29006 n/mm^2
safty

qup = punching force

KN/M^2

c2=
c1=
d=
=

1.15

c1
c2

0.3

0.7

180

MM

unsafe increase ts or column head or use drop panel

QUP=
qcup =

punching stress
concrete punching strength

fcu=
25
WALL LOAD =

n/mm^2
2

ts =

0.2

C=

25

KN/M^2

F.c =

1.5

KN/M^2

L.L=
Wsu =
R=

3
11.5
320

KN/M^2
KN/M^2
KN

bo=
A=
qup =
QUP=
qcup =

2340
MM
0.3744
M
315.694
KN
0.97437 n/mm^2
1.29006 n/mm^2
safty

KN/M^2

c2=
c1=
d=
=

1.3

c1
c2

0.3

0.6

180

MM

safe

qup =
QUP=
qcup =

punching force
punching stress
concrete punching strength

fcu=
25
WALL LOAD =

n/mm^2
2

ts =

0.2

C=

25

KN/M^2

F.c =

1.5

KN/M^2

L.L=
Wsu =
R=

3
11.5
320

KN/M^2
KN/M^2
KN

bo=
2160
A=
0.3744
qup = 315.694

MM
M
KN

KN/M^2

c2=
c1=
d=
=

1.5

c1
c2

0.3

0.6

180

MM

QUP= 1.21796 n/mm^2


qcup = 1.29006 n/mm^2
safty

qup =
QUP=
qcup =

punching force
punching stress
concrete punching strength

safe

GO EDGE
COLUMN

GO TO CONERNER
COLUMN

DESIGN BY ENG KHALED MOSTAFA 2013

DESIGN BY ENG KHALED MOSTAFA 2013

UP

UP

UP

BACK

BACK

You might also like