TesTex provides high speed eddy current testing services for heat exchangers and condensers using their TX 4400 ECT system combined with automated probe driving systems. Their systems can inspect up to 8 tubes per minute, making it the fastest inspection available. The automated systems minimize inspection time and allow inspection of thousands of tubes in a day. TesTex's services are backed by over 20 years of field testing experience.

Uploaded by

pitichai_p
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
46 views1 page

HSECT Literature

TesTex provides high speed eddy current testing services for heat exchangers and condensers using their TX 4400 ECT system combined with automated probe driving systems. Their systems can inspect up to 8 tubes per minute, making it the fastest inspection available. The automated systems minimize inspection time and allow inspection of thousands of tubes in a day. TesTex's services are backed by over 20 years of field testing experience.

Uploaded by

pitichai_p
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

TesTex

HIGH SPEED EDDY CURRENT


TESTING FOR HEAT EXCHANGERS AND CONDENSERS

State of the Art Products


and Services for NDT

TesTex, Inc. provides high speed automated eddy


current testing using the TX 4400 ECT system combined with
either the PD 6k or the PDP 22 system. The PD 6k is a fully
automated probe driving system with a manual probe retrieve.
The PDP 22 is a fully automated probe driving and probe
retrieving system. With the ability to inspect up to 8 (30ft/
10m long) heat exchanger or condenser tubes per minute, this
is clearly the fastest turn-key inspection in the world.
TM

TM

TM

TM

Analysis being done online as tubes are being inspected

FLAW REPRESENTATION

ASME calibration standard with gradual wall loss

Shows probe about to be inserted in the next tube with air gun

ADVANTAGES OF OUR SERVICE

.
..
.
.
.
..
.
..
.

Minimized inspection time leads to shorter outages.


Probe insertion speed up to 22 ft/sec.
Inspection of up to 8 tubes per minute (30ft/10m long).
System and services backed by over 20 years of actual field
testing services.
Uses a 4 frequency, simultaneous injection, ECT system with 8
standard channels along with multiple mixing channels.
Using 4 frequencies eliminates false positives such as magnetic inclusions.
I.D./O.D. defects are immediately distinguishable.
Unwanted signals such as support plates can be suppressed.
Possible to inspect up to 2,000 - 2,500 tubes (30 long) in a
normal working day using a single instrument.
Typical response from the above calibration standard
Manual and computer automated analysis is done on the spot.
Final draft report issued immediately after testing is completed.
Report includes colored tube sheet maps so problem areas can A) 360 degree 10% I.D. ring
G) 40% O.D. pit
be immediately identified.
B) 360 degree 10% O.D. ring
H) 60% O.D. pit
C,D,E) Long O.D. thinning
I) 80% O.D. pit
F) 20% O.D. pits
J) 0.052 dia. thru hole

HEADQUARTERED IN PITTSBURGH, PENNSYLVANIA, USA


Tel: 412-798-8990 Fax: 412-798-8995 www.testex-ndt.com