Parts Location Guide: EMC VNX Family VNX5300
Parts Location Guide: EMC VNX Family VNX5300
VNX5300
This guide describes one of five models available in the VNX Series, the EMC
VNX5300. This guide is a parts location guide and provides illustrations of the part
number label locations of orderable parts for the EMC VNX5300 platform. Included in this
parts location guide are also tables describing the individual VNX5300 parts or
components and how these components are identified as either customer replaceable
units (CRUs) or field replaceable units (FRUs).
This guide is available online at https://mydocs.emc.com/VNX/relatedDocs.jsp. From the
VNX Hardware Parts heading, click on the desired guide. The guide will appear in your
browser.
Topics include:
IMPORTANT
The part numbers listed in this guide are for reference only. Part numbers can change over
time, and this document does not keep pace with those changes. The EMC parts inventory
system will automatically substitute for the latest part numbers as required.
Revision history
The following table presents the revision history of this document:
Revision
Date
Description
A01
Title
Description
VNX5300 components on
page 7
DIMMs on page 35
Related documentation
EMC provides the ability to create step-by-step planning, installation, and maintenance
instructions tailored to your environment. To create VNX customized documentation, go
to: https://mydocs.emc.com/VNX/.
To download a PDF copy of the desired publication, go to the following sections:
For hardware-related books, go to the About VNX section, and then select Learn about
VNX. Next, follow the steps in the wizard.
For technical specifications, go to the About VNX section, and then select View
technical specifications. Next, follow the steps in the wizard.
For installation, adding, or replacing tasks, go to the VNX tasks section, and then
select the appropriate heading. For example, to download a PDF copy of the VNX5300
Block Installation Guide, go to Install VNX and follow the steps in the wizard.
For server-related tasks, go to the Server tasks for the VNX5300, VNX5500, VNX5700,
and VNX7500 section, and then select the appropriate heading. For example, to
download a PDF copy of Adding or replacing hardware, go to Add or replace hardware
and follow the steps in the wizard.
Front view
On the front, viewing from top to bottom, a Block and File VNX5300 platform includes the
following hardware:
Figure 1 shows an example of the front of a Block and File VNX5300 platform with a 3U, 15
(3.5-inch) DPE.
AC
AC
AC
AC
Data Mover
Enclosure 0
DVD
Control Station 1
(optional)
DVD
Control Station 0
3U, 15 (3.5-inch)
disk processor
enclosure (DPE)
SPS
VNX-000562
Figure 1 Example of the Block and File VNX5300 platform with a 3U, 15 (3.5-inch) DPE (front view)
Figure 2 shows an example of the front of a Block and File VNX5300 platform with a 3U, 25
(2.5-inch) DPE.
AC
AC
AC
AC
Data Mover
enclosure 0
DVD
Control Station 1
(optional)
DVD
Control Station 0
24
3U, 25 (2.5-inch)
disk processor
enclosure (DPE)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
SPS
VNX-000612
Figure 2 Example of the Block and File VNX5300 platform with a 3U, 25 (2.5-inch) DPE (front view)
Note: A Block and File VNX5300 platform has one 2U Data Mover enclosure, one 1U
Control Station, one 3U DPE, and one dual 1U SPS. In the following sections, the
illustrations and corresponding tables describe these individual components. These
descriptions are for illustrative purposes only.
Rear view
On the rear, viewing from top to bottom, a Block and File VNX5300 platform includes the
following hardware components:
One 3U DPE with two storage processors (SP A and B); each SP has one CPU module
and one power supply/cooling module
CS
Data Mover
Enclosure 0
1
0
2
1
0
3
1
0
1
0
1
0
1
0
Figure 3 shows an example of the rear of a Block and File VNX5300 platform.
MGMT
Control Station 1
(optional)
CS
MGMT
Control Station 0
A
PART NUMBER
REV A09
A
PART NUMBER
REV A09
A
PART NUMBER
REV A09
A
PART NUMBER
REV A09
A
8Gb 6Gb
fibre SAS
2
8Gb 6Gb
fibre SAS
1 X4
1 X4
6Gb SAS
0 X4
Disk
processor
enclosure
6Gb SAS
0 X4
SPS
VNX-000563
VNX5300 components
VNX5300 components
Viewing from the bottom to the top, the Block and File VNX5300 platform includes several
components. The following sections discuss each component in an illustration and table.
The illustration will show or point out the location of the part number label on the
component. The table will list the part number, describe the component or part, and tell
you if it is a FRU or CRU or both.
I/O modules
SP I/O modules
DME I/O modules
S/N
S/N
900-XXX-0014 0082
900-XXX-0014 0082
REV A00
REV A00
CNS-001545
Table 5 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Part number
Description
FRU
CRU
078-000-084
078-000-085
Front view
The 3U DPE supports two types of disk drive carriers:
VNX-000607
Figure 5 Example of the DPE 3U, 15 (3.5-inch) disk drive (front view)
Note: Figure 5 is for illustrative purposes only. The front of the disk modules may be a little
different than the ones in your particular cabinet.
Table 2 is an example of the parts available for the 3U, 15 (3.5-inch) DPE and lists the part
number label location, part number, description, and whether it is a FRU or CRU.
IMPORTANT
Due to the extensive variety of disk module types, Table 2 only lists two disk types. EMC
recommends that you refer to the latest EMC VNX5100 and VNX5300 Series Storage
Systems Disk and OE Matrix Guide to ensure that you have the correct part for your
configuration.
FRU
CRU
005049299
005049301
Note: The description field describes the disk module type, capacity, drive type, and spindle
speed (rpm).
24
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
VNX-000603
Figure 6 Example of the DPE 3U, 25 (2.5-inch) disk drive (front view)
Note: Figure 6 is for illustrative purposes only. The front of the disk modules may be a little
different than the ones in your particular cabinet.
Table 3 is an example of the parts available for the 3U, 25 (2.5-inch) DPE and lists the part
number label location, part number, description, and whether it is a FRU or CRU.
IMPORTANT
Due to the extensive variety of disk module types, Table 3 only lists two disk types. EMC
recommends that you refer to the latest EMC VNX5100 and VNX5300 Series Storage
Systems Disk and OE Matrix Guide to ensure that you have the correct part for your
configuration.
FRU
CRU
005049292
005049294
Note: The description field describes the disk module type, capacity, drive type, and spindle
speed (rpm).
10
Rear view
Figure 7 shows the rear view of the 3U disk processor enclosure (DPE) with two storage
processors (SP A and B).
3
PART NUMBER
REV A09
A
PART NUMBER
REV A09
A
PART NUMBER
REV A09
A
PART NUMBER
REV A09
A
8Gb 6Gb
fibre SAS
2
8Gb 6Gb
fibre SAS
1 X4
1 X4
6Gb SAS
0 X4
6Gb SAS
0 X4
SP B
SP A
VNX-000614
Table 4 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Part number
Description
FRU
CRU
100-562-503
100-563-138
110-140-408B
110-140-400B
071-000-529
303-092-102B
303-141-100A1
303-081-105B2
11
Part number
Description
FRU
CRU
303-142-100A3
303-164-104D-014
100-562-718
1. This part is not shown in the example DPE illustration in Figure 7. For a closer view, go to Figure 21 on
page 24.
2. This part is not shown in the example DPE illustration in Figure 7. For a closer view, go to Figure 22 on
page 25.
3. This part is not shown in the example DPE illustration in Figure 7. For a closer view, go to Figure 23 on
page 26.
4. This part is not shown in the example DPE illustration in Figure 7. For a closer view, go to Figure 24 on
page 27.
VNX-000608
Table 5 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
12
Part number
Description
FRU
071-000-529
CRU
SP
Figure 9 shows the part number label location on the SP.
SP part number (P/N) label
PART NUMBER
REV A09
A
PART NUMBER
REV A09
A
8Gb 6Gb
fibre SAS
2
X4
6Gb SAS
0 X4
VNX-000613
Figure 9 Example of an SP
Table 6 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Part number
Description
FRU
110-140-408B
110-140-400B
CRU
To access the SP CPU, you must first remove the SP from the 3U DPE (Figure 10 on
page 14). Then, you must remove the power supply/cooling fan modules (Figure 11 on
page 14).
13
Figure 10 shows the SP partially removed from the front of the DPE.
CL4594
Figure 11 shows the power supply/cooling module being removed from the SP.
CL4595
14
The part number labels for the SP and the SP CPU module in Figure 12 are listed in Table 6
on page 13. The SP CPU part number label is located on the motherboard of the SP CPU
(Figure 12).
SP
part number (P/N) label
SP CPU
part number (P/N) label
VNX-000665
Figure 12 Example of the SP CPU with power supply/cooling module set aside
15
Control Station
Control Station
Figure 13 shows the part number label location on the front of the 1U Control Station.
Part Number (P/N) label
CNS-001544
Table 7 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Part number
Description
FRU
100-520-665
CRU
Front view
1
AC
AC
16
AC
AC
CNS-001723
Table 8 provides the part number label location, part number, description, and whether it
is a FRU or CRU.
Part number
Description
FRU
CRU
071-000-5431
110-113-102B
303-113-101B
1. The part number label on the power supply/cooling fan module is located on the lower half of the pull
handle.
AC
AC
CNS-001682
17
Table 9 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Part number
Description
FRU
CRU
071-000-543
1
2
2
1
1
2
CL3972
Figure 16 Example of the Data Mover power supply/cooling fan module removal
Figure 17 on page 19 shows the Data Mover CPU module partially removed from the front
of the Data Mover enclosure with the two power supply/cooling fan modules set aside.
The part number label for the Data Mover CPU module in Figure 17 on page 19 is listed in
Table 10 on page 19.
Note: The DM CPU part numbers are located on the DM CPU sheet metal. You must remove
the DM from the DM enclosure (Figure 17 on page 19). You can also find the DM CPU part
number label located inside the DM CPU by looking through the blue plastic DIMM cover.
The part number label is located on the motherboard.
18
Power/cooling modules
Data Mover enclosure
CNS-001683
Figure 17 Example of the Data Mover CPU being removed from a Data Mover enclosure
Table 10 Data Mover CPU part number
Part number label
location
Part number
Description
FRU
Figure 14 on
page 16
110-113-102B
Figure 17 on
page 19
303-113-101B
CRU
Rear view
Figure 18 shows the part number label location on the rear of a Data Mover enclosure.
3
1
0
1
0
1
0
1
0
2
0
2
1
0
2
1
0
2
1
0
3
1
0
CNS-001724
19
Table 11 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Part number
Description
FRU
100-562-178
110-130-100B
303-092-102B
303-122-100A
100-562-718
CRU
303-081-103B2
303-195-100B3
303-164-104D-014
1. This part is not shown in the example Data Mover enclosure illustration in Figure 18 on page 19. For a closer
view, go to Figure 27 on page 30.
2. This part is not shown in the example Data Mover enclosure illustration in Figure 18 on page 19. For a closer
view, go to Figure 22 on page 25.
3. This part is not shown in the example Data Mover enclosure illustration in Figure 18 on page 19. For a closer
view, go to Figure 28 on page 31.
4. This part is not shown in the example Data Mover enclosure illustration in Figure 18 on page 19. For a closer
view, go to Figure 24 on page 27.
20
I/O modules
Management module
Figure 19 shows the part number label location on the rear of the Data Mover enclosure
management module used in the Data Mover enclosure.
Part Number (P/N label
2
1
0
#
CNS-001684
Table 12 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Part number
Description
FRU
CRU
110-130-100B
Management module
I/O modules
In the Block and File VNX5300 platform, I/O modules are used in the disk processor
enclosure (DPE) storage processors (SP A and B) and in the Data Movers of the Data Mover
enclosure.
Each I/O module is identified by a part number, type of ports (copper or optical), latch
handle label, and color label on top of the latch handle. For ease of identification,
Table 13 on page 22 describes each I/O module type in the VNX5300.
21
I/O modules
I/O module
Part number
Ports
Latch handle
label
Four-port 8-Gb/s FC
303-092-102B
Optical
8 Gb Fibre
Silver
Four-port 1-Gb/s
303-141-100A
Copper
1 GbE iSCSI/TOE
Orange
Optical
10 GbE
Orange
303-142-100A
Optical
10 GbE/FCoE
Green
303-164-104D-01
Copper
10 GbE Base-T
Orange
303-122-100A or B
Copper
plus
optical
1 GbE
Brown
Two-port 10-Gb/s
303-081-103B or C
Optical
10 GbE iSCSI or
10 GbE v2
Orange
Two-port 10-Gb/s
303-195-100C-01
Optical
10 GbE v3
Orange
Four-port 10/100/1000
Ethernet
303-121-100A
Copper
1 GbE
Brown
SP
Five types of I/O modules are supported in the SP:
Two-port 10-Gb/s Fibre Channel over Ethernet (FCoE) I/O module on page 26
Data Mover
Seven types of I/O modules are supported in the Data Mover:
22
Two-port 10-Gb/s Fibre Channel over Ethernet (FCoE) I/O module on page 26
Two-port 1-Gb/s copper plus two-port 1-Gb/s optical I/O module on page 28
I/O modules
The following sections describe these I/O modules and the part numbers. Refer to these
when determining which part number you need for either the SP or Data Mover that the
I/O module goes in.
CNS-001698
Table 14 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Part number
Description
FRU
CRU
303-092-102B
23
I/O modules
CNS-001699
Table 15 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Table 15 Four-port 1-Gb/s copper iSCSI I/O module part number
Part number label
location
(Figure 21)
24
Part number
Description
FRU
CRU
303-141-100A
I/O modules
CNS-001700
Figure 22 Example of the two-port 10-Gb/s optical (w/iSCSI protocol) I/O module
Table 16 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Table 16 Two-port 10-Gb-s optical (w/iSCSI protocol) I/O module part number
Part number label
location
(Figure 22)
Part number
Description
FRU
CRU
303-081-105B
25
I/O modules
CNS-001700
Figure 23 Example of the two-port 10-Gb/s FCoE I/O module with SFPs1
Note: The 10-Gb/s FCoE I/O module requires VNX OE for File version 7.0.35.3 or later.
Table 17 shows the part number label location, part number, description, and whether it
is a FRU or CRU.
Part number
Description
FRU
CRU
303-142-100A
1. The FCoE I/O module can also use twinaxial (Twinax) cables. Twinax is a type of cable similar to coax, but with two inner conductors
instead of one. These cables will be supplied in lieu of SFPs when so ordered.
26
I/O modules
VNXe-000753
Figure 24 Example of the two-port 10-Gb/s RJ-45 Base-T iSCSI/IP I/O module
Note: The two-port 10-Gb/s RJ-45 Base-T iSCSI/IP I/O module requires VNX OE for File 7.1
or later.
Table 20 shows the part number label location, part number, description, and whether it
is a FRU or CRU.
Table 18 Two-port 10-Gb/s RJ-45 RJ-45 Base-T iSCSI/IP I/O module part number
Part number label
location
(Figure 24)
Part number
Description
FRU
CRU
303-164-104D-01
27
I/O modules
CNS-001701
Figure 25 Example of the two-port 1-Gb/s copper plus two-port 1-Gb/s optical I/O module
Table 19 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Table 19 Two-port 1-Gb/s copper plus two-port 1-Gb/s optical I/O module part number
Part number label
location
(Figure 25)
28
Part number
Description
FRU
CRU
303-122-100A or B
I/O modules
CNS-001700
Table 20 shows the part number label location, part number, description, and whether it
is a FRU or CRU.
Part number
Description
FRU
CRU
303-081-103B or C
29
I/O modules
CNS-001699
Table 21 shows the part number label location, part number, description, and whether it
is a FRU or CRU.
Table 21 Four-port 1-Gb/s copper I/O module part number
Part number label
location
(Figure 27)
30
Part number
Description
FRU
CRU
303-121-100A
I/O modules
CNS-001700
Note: This two-port 10-Gb/s optical I/O module requires VNX OE for File version 7.1 or
later.
Table 22 shows the part number label location, part number, description, and whether it
is a FRU or CRU.
Part number
Description
FRU
CRU
303-195-100C-01
31
Class 1 laser product.
Because invisible laser radiation can be emitted from the aperture of the port when no
fiber is connected, avoid exposure to laser radiation and do not stare into open
apertures.
Laser radiation is present when the system is open and interlocks bypassed.
Only trained and qualified personnel should be allowed to install, replace, or service this
equipment.
32
SFP and SFP+ modules are static sensitive. Wear an ESD-preventive wrist strap that is
connected to the rack in order to prevent ESD damage.
SFP and SFP+ modules are dust sensitive. Always store the devices with dust plugs
installed in the optical bores.
Do not remove and insert an SFP or SFP+ module more often than is necessary.
Repeated removals and insertions of an SFP or SFP+ module can shorten its useful
life.
2. The 10 Gb/s module (labeled 10 GbE v3) can also use active twinaxial (Twinax) cables. Twinax is a
type of cable similar to coax, but with two inner conductors instead of one. These cables will be
supplied in lieu of SFPs when so ordered.
3. The FCoE I/O module can also use active twinaxial (Twinax) cables. Twinax is a type of cable
similar to coax, but with two inner conductors instead of one. These cables will be supplied in lieu
of SFPs when so ordered.
EMC VNX5300 Parts Location Guide
33
-00
:
P/N
X
-XX
00
CNS-001347
Table 23 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Note: The SFP or SFP+ part number is visible only when the SFP or SFP+ is removed from an
I/O module port.
Part number
Description
FRU
CRU
019-078-032
(SFP)
019-078-041
(SFP+)
019-078-042
(SFP+)
Note: Only the two optical ports (physically labeled on this I/O module as 2 and 3, but logically
fge-x-2 and fge-x-3) use this type of SFP.
34
DIMMs
DIMMs
The Storage Processor (SP) requires 4 GB per SP or a total of 8 GB per array and the Data
Mover requires 6 GB per Data Mover.
SP DIMMs
The SP CPU uses SDRAM DIMMs4. Each SP uses three 4-GB unbuffered Double-Data-Rate
3 (DDR3) type memory for a total of 12 GB per SP or 24 per DPE or array. Figure 30 on
page 36 shows an example of the location of the SP DIMM slots.
IMPORTANT
The DIMM part numbers are visible only when you remove the DIMM from the DIMM slot.
You must first take the SP out of service, disconnect any SP cables, remove the SP from the
DPE, then remove the SP power supply/cooling module from the SP (see Figure 10 on
page 14, Figure 11 on page 14, and Figure 12 on page 15). With the SP CPU laying on an
antistatic mat, lift the DIMM cover up in the SP CPU, and then remove the DIMM from the
DIMM slot. Ensure that you remove only those DIMMs that you intend to replace. For more
information about removing and installing the DIMM or memory module, refer to the
Replacing a memory module procedure available from the VNX Procedure Generator
program.
The DIMM memory is not hot-swappable. Before removing or replacing any DIMMs, you
must follow the removing and installing the DIMM or memory module procedure
described in the Replacing a memory module procedure available from the VNX
Procedure Generator program.
Note the orientation of the VNX5300 Block and File platform SP DIMMs (see locations
DIMM 0, DIMM 1, and DIMM 2 in Figure 30 on page 36). A label on the DIMM cover also
identifies the DIMM slots as DIMM 0, DIMM 1, and DIMM 2. In the VNX5300 Block and
File platform, the SP DIMMs are placed in slots 0, 1, and 2.
4. The term DIMM is used throughout this guide. The term DIMM is also referred to as a memory
module. These terms are interchangeable and basically mean the same thing.
EMC VNX5300 Parts Location Guide
35
DIMMs
DIMM 0
DIMM 1
DIMM 2
DIMM 1
DIMM 0
3
1
VNX-000610
Figure 30 Example of the Block and File VNX5300 platform SP DIMM slot location
36
DIMMs
100-562-264v
P/N : 100-562-xxx
Rev : A01
A01.
CNS-001540
Figure 31 Example of the Block and File VNX5300 platform SP DIMM part number location
Table 24 lists the SP DIMM part number location, description, and whether it is a FRU or
CRU.
Part number
Description
FRU
100-563-325
CRU
The DIMM memory is not hot-swappable. Before removing or replacing any DIMMs, you
must follow the removing and installing the DIMM or memory module procedure
described in the Replacing a memory module procedure available from the VNX
Procedure Generator program.
37
DIMMs
Note the orientation of the VNX5300 Block and File platform Data Mover DIMMs (see
locations DIMM 0, DIMM 1, DIMM 2, DIMM 3, DIMM 4, and DIMM 5 in Figure 32 on
page 38). A label on the DIMM cover also identifies the DIMM slots as DIMM 0, DIMM 1,
DIMM 2, DIMM 3, DIMM 4, and DIMM 5. In the VNX5300 Block and File platform, the Data
Mover DIMMs are placed in slots 0, 2, and 4. Slots 1, 3, and 5 are left empty.
D
D IM
D IMM M 5
D IM 4
D IM M 3
D IMM M 2
IM
M 1
0
DIMM 5
DIMM 4
DIMM 3
DIMM 2
DIMM 1
DIMM 0
CNS-001766
Figure 32 Example of the Block and File VNX5300 platform Data Mover DIMM slot location
38
Figure 33 shows the Data Mover DIMM part number label location.
100-562-264v
P/N : 100-562-xxx
Rev : A01
A01.
CNS-001540
Figure 33 Example of the Block and File VNX5300 platform Data Mover DIMM part number location
Table 25 lists the Data Mover DIMM part number label location, part number, description,
and whether it is a FRU or CRU.
Part number
Description
FRU
100-562-863
CRU
Front view
The DAE has two types of disk drive carriers:
39
VNX-000607
Figure 34 Example of the 3U, 15 (3.5-inch) disk drive DAE (front view)
Note: Figure 34 is for illustrative purposes only. The front of the disk modules may be a
little different than the ones in your particular cabinet.
Table 26 is an example of the parts available for the 3U, 15 (3.5-inch) disk drive DAE and
lists the part number label location, part number, description, and whether it is a FRU or
CRU.
IMPORTANT
Due to the extensive variety of disk module types, Table 26 only lists two disk types. EMC
recommends that you refer to the latest EMC VNX5100 and VNX5300 Series Storage
Systems Disk and OE Matrix Guide to ensure that you have the correct part for your
configuration.
Part number
FRU
CRU
005049299
005049301
Note: The description field describes the disk module type, capacity, drive type, and spindle
speed (rpm).
40
VNX-000602
Figure 35 Example of the 2U, 25 (2.5-inch) disk drive DAE (front view)
Note: Figure 35 is for illustrative purposes only. The front of the disk modules may be a
little different than the ones in your particular cabinet.
Table 27 is an example of the parts available for the 2U, 25 (2.5-inch) disk drive DAE and
lists the part number label location, part number, description, and whether it is a FRU or
CRU.
IMPORTANT
Due to the extensive variety of disk module types, Table 27 only lists two disk types. EMC
recommends that you refer to the latest EMC VNX5100 and VNX5300 Series Storage
Systems Disk and OE Matrix Guide to ensure that you have the correct part for your
configuration.
Part number
FRU
CRU
005049292
005049294
Note: The description field describes the disk module type, capacity, drive type, and spindle
speed (rpm).
41
Rear view
The DAE has two types of LCC modules and power supplies:
X4
X4
6Gb SAS
6Gb SAS
LCC B
LCC A
VNX-000605
Table 28 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Part number
Description
FRU
071-000-518
303-108-000E
LCC B
CRU
1. The rear of the 3U, 15 (3.5-inch) DAE has the LCC power supply and LCC inverted or on top of each other. In
other words, the LCC B power supply is located on the top of LCC B. While LCC A is located on the bottom of
the DAE with LCC A on top of the LCC A power supply (Figure 36).
42
#
X4
X4
6 Gb
SAS
6 Gb
SAS
#
VNX-000606
Table 29 lists the part number label location, part number, description, and whether it is a
FRU or CRU.
Table 29 2U, 25 (2.5-inch) DAE LCC and power supply part numbers
Part number label
location
(Figure 37)
Part number
Description
FRU
071-000-541
303-104-001E
LCC B2
CRU
1. The rear of the 2U, 25 (2.5-inch) DAE has the LCC power supplies inverted or on opposite sides. In other
words, the LCC B power supply is located on the left of the DAE and the LCC A power supply is located on the
right (Figure 37).
2. The rear of the 2U, 25 (2.5-inch) DAE has the LCCs inverted or on top of each other. In other words, LCC B is
located on the top and LCC A is located on the bottom (Figure 37).
43
Copyright 2012 EMC Corporation. All rights reserved. Published in the USA.
Published June 26, 2012
EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without
notice.
The information in this publication is provided as is. EMC Corporation makes no representations or warranties of any
kind with respect to the information in this publication, and specifically disclaims implied warranties of
merchantability or fitness for a particular purpose. Use, copying, and distribution of any EMC software described in this
publication requires an applicable software license.
EMC2, EMC, and the EMC logo are registered trademarks or trademarks of EMC Corporation in the United States and other countries.
All other trademarks used herein are the property of their respective owners.
For the most up-to-date regulatory document for your product line, go to the technical documentation and advisories
section on EMC Online Support.
44