Pump Basic Calculation PDF
Pump Basic Calculation PDF
DURAQUIPT CEMERLANG
Your Trusted Partner in Industrial Pump And Solution
PUMP CALCULATION
I. HEAD (Tanpa memperhitungkan posisi Discharge dan Suction pressure gauge )
Head = Diff. Press. X 2.31 / S.G
(Feet)
(Psi)
Head
200 ft ~ 500 ft
500 ft ~
Level "A"
+5% , -0
+3% , -0
Level "B"
+5% , -3%
+3% , -0
Discharge
Pressure
Pipe 2"
Suction
pressure
Y
Pipe 4"
V. Efisiensi
V. Effesiensi
pompa Pompa
Hydraulic Horse Power (HHP)
=
( Effesiensi Pompa )
: Pada Capacity 0% (minimum flow) Head harus lebih kecil dari 140% X Rated Head
: Pada Capacity 150% (maximum flow) Head harus lebih besar dari 65% X Rated Head
AFFINITY LAWS
2
Q2 = Q1 (N2/N1)
Q = Capacity
N = Rpm
H2 = H1 (N2/N1)
H = Head
N = Rpm
(
)
Q2 = Q1 (D2/D1)
Q = Capacity
D = Impeller Diameter
(
)
H2 = H1 (D2/D1)
H = Head
D = Impeller Diameter
P1/P2 = (N1/N2)
P = Power
N = Rpm
Mechanical Seal Bekerja pada Stuffing box pressure ( Reference from John Crane )
Stuffing Box Pressure = ( 0.15~0.3 X Diff. Pressure ) + Suction Press