MINIMUM PHYSICAL PLANNING STANDARDS FOR SMALL HOTELS
AND SELF-CONTAINED APARTMENTS
1.___ FIVE ROOM HOTEL ESTABLISHMENTS
GENERAL: Each hotgl should contain at least five units for letting. Each room
GUEST ROOM:
KITCHEN:
|
|
FOOD STORAGE:
RECEPTIONIST
ARE:
should have its own private bathroom with shower, tub and wash
basin for, the exclusive use of its occupant(s). In addition to the
rooms for letting each hotel should contain adequate kitchen and
dining facilities, living and lounge area, receptionist area, storage,
laundry, bar as well as staff quarters with toilet facilities.
‘Adequate parking facilities and open landscaped areas are also to
be provided on sit
No guest room should be less than 190 square feet in The
room should contain a private bathroom of no less then 36 square
feet in area, Each guestroom should have at least one window
‘opening ‘of reasonable size to facilities adequate lighting and
ventilation. The room should adequately accommodate two (2)
single beds 6°x3"x3" or a double bed 6’x3"x5"x0”, a bedside table,
cupboards, dressing table, a reading lamp and two sitting, chairs.
Kitchen fizes should be a minimum of 130 square feet for five
room establishments operating a kitchen solely for guests resident
at the hofel. The size of the kitchen is to.be increased by 40 square
feet for dach additional 20 persons to be,catered for. Each kitchen
is to bd equipped with stainless steel sink and reffigeration
facilities| for food storage as well as, cooking units for food
preparation, Running water is also prerequisite.
‘A minimum. area of 50 square feet should be provided for the
storage of food in the five room type hotel establishment. An
additional ten square feet must however be provided for cach
additional twenty persons to be catered for.
A minimum of 300 square feet should be allocated as dining space
solely for resident guests in the typical five room hotel
establishment, An additional 12 square feet is required for each
additional resident and or visiting guest. The dining area of a five
room establishment should accommodate a minimum of twenty
chairs distributed around five tables, of size 4-0" x4"-0"
A im of 100 square feet should be provided complement on
adjoining lobby area of not less than 80 square feet.
Optionallindoor of outdoor. (1) Indoor minimum of 48 square feet
completé with equipment, (2) Outdoor a minimum of 200 square
feet.
‘A minintum area of 100 square feet should be provided. In
addition, a drinking area of minimum size 60 square feet should be
provided to cater for non-resident guests.STAFF ROOM:
PUBLIC TOILETS:
GENERAL STORAGE:
A minimum of 200 square feet for staffing service should be
provided) complete with lockers for staff members, changing
facilites and male and female toilets
A minimjum of two toilets should be provided for non.
and wonjen of minimum size 36 square feet.
ssident men
A minimum of 100 square |feet should be provided for general
storage of dry goods, tools and equipment.
|
SITE PLANNING REQUIREMENTS
VEHICLE PARKING:
SITE COVERAGE:
BUILDING LINES:
A mininium of four on-site parking spaces should be provided for
‘a five room hotel establishment. An additional one parking space
should be provided for cach additional four scats of dining and
drinking space provided. Parking requirements may be relaxed in
special Circumstances, eg the Grenadines where there is low
vehicle count
[A maxinjum building coverage of 60% of the total site area will be
permit,
10,000 shuare feet, minimum! floor area 3000 square feet
Building| should not exceed four (4) storeys or a total building,
height of 43°-0 overall
All buildings should observe a minimum setback from the high
water mark of 40° in coastal areas, and septic tanks should not be
Ioeated closer than 50° from high water mark (HLW.M),
Minimum setbacks from roads:
(A) Highways - 20 feet
(B) Residential Collector - 15 feet
(©) Residential access. ~ 10 feet
Minis ny setback from rear boundaries — 15 feet and side
feeSUMMARY SPACE REQUIREMENTS - BASIC FIVE ROOM HOTEL
ESTABLISHMENT.
Guest rooms 6 @ 1904.8) 950 49.
Kitchen dss sq. ft) 190 sq, ft.
Food Storage Go) 50 sq. ft.
Receptionist area (80) 180 sq. ft
Laupry internal de 48 99.
Bar| 60) 160 4, ft
Staff (00) 200 sq. ft
Public toilets @@ 3659.) 72. sq. &
General store (100) 100 sq. ft.
Circulation space (450) 450 sq. ft
Balcony/Patio/Porch (300) 300 sq.
Minimum floor area 3000 sq.
‘Maximum building coverage : 60%
Minimum plowLot size 10,000 sq. ft.
i
2. | SELF-CONTAINED UNITS
|
GENERAL: Each complex must contain at least five units for letting, Each unit
f should bb self-contained with, its own private bathroom, kitchen,
ing, living and sleeping fa Adequate parking facilities
and openilandscaped areas are also to be provided on site
ROOM AND ROOM SIZE!
UNITS Each unij should be a jum of 330 square feet in size and
should contained:-
(@) —_Alprivate bathroom of no less than 36 square feet in area
(&) _Alkitchen or kitchenette Surnished with sink, running water,
‘ddainboard, gas or electric cookeriand a refrigerator
(© Alaining or tiving aren with dining table, wo dining chairs
arid two sitting chair
(a) Aj sleeping area with two single beds 6-3"x3"-0" or a
double bed 6’-3"x5°-0", a bedside table, cupboards, reading
lamps and wardrobes,
i (© Each unit should have at least one window opening of
reasonable size to facilitate adequate light and ventilation,OFKICE AND
RECEPTIONIST
ARIA:
STARE
FACILITIES:
GENERAL STORAGE:
A minimum of 100 square feet should be provided for office space
and an additional adjoining 80 square feet for lobby and
receptionist area.
A minimim 200 square feet for service staff should be provided
complete'with lockers for staff, changing facilities and staff toilet
facilities.
A minimum of 100 square feet should be provided for general
storage of dry goods, tools, equipments, etc.
SITE PLANNING REQUIREMENT!
VEHICLE PARKING:
SITE COVERAGE:
MINIMUM PLOT
SIZE
MAXIMUM.
BUILDING HEIGHT:
COASTAL SETBACKS:
BUILDING LINE:
Units
Staff area
General store
Office/Receptionist
Cireular space
‘Minjmum floor area
‘Maximum building coverage
‘Minjinum plot size
i
A minimpm of four (4) on-site parking spaces are to be provided
ona eo tunit complex. ‘An additional one parking. space
should be provided for each additional three units. Parking
requirements may be relaxed in special circumstances e.g, in the
Grenadines where there is low vehicle count.
A maximum building coverage of 60% of the total site area will be
permitted,
10,000 square feet. Minimum floor area 2,500 square feet,
Buildings should not exceed four (4) storeys or a total building
height of 43-0” overall
All buildings should observe a minimum setback from the high
‘water of 40" in coastal areas, and septic tanks should not be located
closer than 50° from high water mark (H.W.M).
‘Setback f rom = Highways - 20 feet
r Residential collector 15 feet
| Residential socoss = to feet
| Side bandaries = iateet
Rear boundary 2 1s feet
SUMMARY SPACE REQUIREMENTS:
LE-CONTAINED UNITS
6 @ 330 sq. 8) 1650 sq, f
(200 sa. .) 200 4.
(100) 100 sa.
(aso) 180 sq. ft
50) 250 sa. ft
| 1 2400 sq. ft.
! 60%
t 8000 sq. ft.ENVIRONMENTAL HEALTH STANDARDS
All members related to waste water and sewerage disposal, inclu
ing the layout and design of the
disposal system, shall be designed, carried out and maintained in accordance with a specification
approved by the Public Health Authority.
KITCHEN WASTE |
‘Thd Kitchen Waste Water Disposal System must be provided with grease traps.
WASTE
All garbage on the site is to be collected, stored and disposed of in a manner approved by the
Public Health Authority.