0% found this document useful (0 votes)
427 views

Alarms List

The document describes alarm priorities and classifications for a BTS system. It includes a table listing different alarm priorities and situations. It also provides interpretations for different alarm slogans that describe specific alarm situations, such as "TGC FAULT" indicating no active TGC application, "MAINS FAILURE" indicating a fault in the BTS power supply, and "OPERATOR CONDITION" indicating a condition due to operator intervention.

Uploaded by

Sreejith Sl
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
427 views

Alarms List

The document describes alarm priorities and classifications for a BTS system. It includes a table listing different alarm priorities and situations. It also provides interpretations for different alarm slogans that describe specific alarm situations, such as "TGC FAULT" indicating no active TGC application, "MAINS FAILURE" indicating a fault in the BTS power supply, and "OPERATOR CONDITION" indicating a condition due to operator intervention.

Uploaded by

Sreejith Sl
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 2

Alarms-Priority and Description

Fault Map Designations

Internal External Class 1 Class 2 Class A Class B

Internal to the BTS External to the BTS (by definition also Class B) MO unable to carry out its operational function MO able to carry out its operational function BTS condition present within MO BTS condition present within MO environment

Alarm Priority Resolution

Priority 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Alarm Situation TGC FAULT PERMANENT FAULT LOCAL MODE LMT INTERVENTION LOOP TEST FAILED BTS INT AFFECTED MAINS FAILURE BTS EXT AFFECTED OML FAULT ABIS PATH UNAVAIL CON QUEUE CONGESTION TS SYNC FAULT BTS INT UNAFFECTED BTS EXT UNAFFECTED FORLOPP RELEASE OPERATOR CONDITION

Alarm Slogan TGC FAULT PERMANENT FAULT LOCAL MODE LMT INTERVENTION LOOP TEST FAILED BTS INTERNAL MAINS FAILURE BTS EXTERNAL OML FAULT ABIS PATH UNAVAIL CON QUEUE CONGESTION TS SYNC FAULT BTS INTERNAL BTS EXTERNAL FORLOPP RELEASE OPERATOR CONDITION

Interpretation of Alarm Slogans The alarm slogan is the description of the current alarm situation for an MO or TG. The alarm slogans 'BTS INTERNAL' and 'BTS EXTERNAL' each describe more than one alarm situation. The remaining alarm slogans each describe a unique alarm situation. This section describes how each alarm slogan should be interpreted. TGC FAULT No active TGC application exists in the Transceiver Group. PERMANENT FAULT A managed object is classified as being permanently faulty when fault situations have occurred, and have been cleared, a certain number of times within a certain period of time. Manual intervention is required to bring such equipment back into operation. LOCAL MODE The BTS equipment is in Local Mode or the BTS equipment has changed from Local to Remote Mode and a fault exists in the communication link between the BSC and the BTS. Communication between the BSC and the BTS is not possible. LMT INTERVENTION Local maintenance activities are being performed in the BTS. LOOP TEST FAILED Test of the traffic carrying capabilities of the TS has failed. BTS INTERNAL There is a fault internal to the BTS. MAINS FAILURE There is a fault in the power supply to the BTS or one or more items of equipment within the BTS. Battery backup (where available) is in use. Escalation may occur if corrective action is not taken. BTS EXTERNAL There is a fault external to the BTS. OML FAULT There is a fault in the communications link between the BSC and BTS. ABIS PATH UNAVAIL No transmission device exists between the BSC and BTS. CON QUEUE CONGESTION At least one of the LAPD Concentrator concentration outlet queues has reached an unacceptable filling level. TS SYNC FAULT Synchronisation lost on uplink or downlink TRA or PCU channels. FORLOPP RELEASE A fault has occurred within the BSC software leading to a Forlopp release. Automatic recovery procedures are taking place. Report to your Ericsson Support Office. Alternatively, this alarm is issued as an advisory following a command ordered Forlopp release of a TG. In either case, the alarm is automatically ceased following successful recovery. OPERATOR CONDITION A condition has arisen due to operator intervention