Installation Instructions for the DS860 Series TriTech Microwave/PIR Intrusion Detectors
1.0
Specifications
Dimensions (HxWxD): 5 in. x 2.8 in. x 2.2 in. (12.7 cm x 7.1 cm x 5.6 cm) Input Power: 9 to 15 VDC, 16 mA DC nominal (up to 48 mA DC during walk testing or trouble conditions). Useonly an Approved Limited Power Source. No internal standby battery. Standby power must be provided by an Approved Limited Power Source. Sixteen mAh required for each hour of standby time needed. For UL Listed Requirements, four hours (64 mAh) minimum are required. Silent operating Normally Closed reed relay. Contacts rated 3 watts, 125 mA, 28 VDC maximum for DC resistive loads; and protected by a 4.7 ohm, 0.5 watt resistor in the common "C" leg of the relay. To be connected to a SELV (Safety Extra-Low Voltage) circuit only. Do not use with capacitive or inductive loads. -40F to +120F (-40C to +49C). For UL Listed Requirements, the temperature range is +32F to +120F (0C to +49C). 10.525 GHz (UL Listed) 10.687 GHz (Export only, not UL Listed) 9.9 GHz (Export only, not UL Listed))
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesirable operation. Changes or modifications not expressly approved by Detection Systems, Inc. can void the users authority to operate the equipment.
2.0
NOTE:
Installation Considerations
The DS860 is not recommended for installations containing pets or small animals. Use the DS820 or DS835 for such installations.
Standby Power:
Never install the detector in an environment that causes an alarm condition in one technology. Good installations start with the LED OFF when there is no target motion. It should never be left to operate with the tri-color LED in a constant or intermittent green, yellow, or red condition. Point the unit away from outside traffic (roads/alleys). Microwave energy will pass through glass and most common non-metallic construction walls.
NOTE:
Alarm Relay:
Avoid installations where rotating machines (e.g. ceiling fans) are normally in operation within the coverage pattern. Point the unit away from glass exposed to the outdoors and objects that may change temperature rapidly. The PIR detector will react to objects rapidly changing temperature within its field-of-view.
NOTE:
Eliminate interference from nearby outside sources.
Temperature Range:
3.0
Mounting
Select a location likely to intercept an intruder moving across the coverage pattern. The surface should be solid and vibration-free. Mounting height range is 6 to 8 ft. (1.8 to 2.4 m). Recommended mounting height is 7.5 ft. (2.3 m). Remove the cover. Insert a flathead screwdriver into the locking tab hole at the bottom front of the detector. Pull the cover up and forward.
Microwave Frequency: DS860: DS860A: DS860B:
Coverage: Broad (standard): 60 ft. by 60 ft. (18 m by 18 m) Long Range (optional): 100 ft. by 10 ft. (30 m by 3 m) Internal Pointability: Tamper: +2 to 10 Vertical, 10 Horizontal. Normally Closed (with cover on). Contacts rated at 28 VDC, 125 mA max. To be connected to a SELV (Safety Extra-Low Voltage) circuit only. Connect tamper circuit to 24-hour protection circuit. B328 Gimbal Mount Bracket, B335 Low Profile Swivel Mount Bracket, B338 Ceiling Mount Bracket, OLR92 Long Range Barrier Lens
Wire Entrances Corner Mount Knockout (4) Bracket Mount Knockout Terminal Strip Tri-color LED LED On/Off Pins PIR Sensitivity Selection Pins On Off
0 - 4 - 8
MIN MAX
Vertical Adjust Screw Mount Surface Mount Knockout (2)
Look Down Lens Vertical Adjust Scale Face of Lens (masking area)
Options:
Wire Entrances Cover Tab and Locking Screw Hole
MW Vertical Adjust Screw
NOTE:
Use of a bracket may reduce range and increase dead zone areas.
Microwave Range Adjust
U.S. Patent Numbers: Protected under one or more of the following U.S. Patent Numbers: #4,660,024, #4,764,755, #5,077,548, #5,208,567, #5,262,783, and #5,450,062. Other patents pending. Compliance: This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry and Science Canada. Operation is subject to the following two conditions:
Remove the circuit board from the base. Loosen the Vertical Adjust Screw and slide the circuit board down, then out. Break away the appropriate thin-wall wire entrance and mounting hole coverings in the base. Using the base as a template and aligning it so that the detector will be mounted with the terminal block at the top and the PIR lens at the bottom, mark the location of the mounting holes on the mounting surface. Pre-start the mounting screws.
Route wiring as necessary. Route to the rear of the base and through the wire entrance. Make sure all wiring is unpowered before routing. Securely attach the base to the mounting surface. Return the circuit board to the base and tighten the Vertical Adjust Screw.
6.2
PIR Sensitivity Selection Pins
STD
INT
For selection, place the plug across the pins marked STD for Standard or INT for Intermediate mode.
4.0
Wiring
Only apply power after all connections have been made and inspected. Do not coil excess wiring inside detector. Input power must use only an Approved Limited Power Source. Alarm and Tamper Contacts to be connected to a SELV (Safety Extra-Low Voltage) circuit only.
Alarm 1 2 + 3 4 5 Tamper 6 7 8
Standard Sensitivity: The recommended setting for maximum false alarm immunity. Tolerates environmental extremes on this setting. Intermediate Sensitivity: The recommended setting for any location where an intruder is expected to cover only a small portion of the protected area. Tolerates normal environments on this setting. This setting will improve your intruder catch performance.
CAUTION
NOTE:
7.0
Set-up and Walk Tests
DS860 Mounting Height 6.5 ft. (2 m) 7.5 ft. (2.3 m) 8.0 ft. (2.4 m) Broad 60 ft. (18 m) -4 -5 -6 Long Range 100 ft. (30 m) -2 -3 -3
Select the vertical starting angle from this chart: To adjust the vertical starting angle for the desired mounting height and range, loosen the vertical adjust screw and slide the board up, to point the angle down.
NC C SP T
Alarm Relay
T SP
9-15 VDC Input
Tamper
Terminals 1 () & 2 (+): Voltage limits are 9 to 15 VDC. Use no smaller than #22 AWG (0.8 mm) wire pair between the detector and the power source. Terminals 3 & 4: Alarm relay (reed) contacts rated 3 watts, 125 mA, 28 VDC maximum for DC resistive loads and protected by a 4.7 ohm, 0.5 watt resistor. Do not use with capacitive or inductive loads. Terminals 5 and 8: Spare. Terminals 6 & 7: Tamper contacts rated at 28 VDC, 125 mA. Plug the wire entrance hole with the foam plug provided after all wiring connections have been made.
Note the settings on the vertical adjust scale.
Place the LED plug in the ON position and replace the cover.
NOTE:
7.1
Establishing PIR Pattern Coverage
Turn the Microwave range adjust to minimum. Replace the cover and snap it into place. This will close the tamper switch. Wait two minutes minimum after applying power to start walk tests. During the warm-up period, the tri-color LED will flash red until the unit has stabilized (approximately 1 to 2 minutes) and has seen no movement for two seconds. When the tri-color LED stops flashing, the detector is ready to be tested. With no motion in the protection area, the tri-color LED should be OFF. If the LED is on, re-check the protection area for disturbances affecting the microwave or PIR technologies.
NOTE:
5.0
LED Operation
The detector uses a tri-color LED to indicate the various alarm and supervision trouble conditions that may exist. See chart below.
NOTE:
LED Steady red Steady yellow Steady green Flashing red Flashing red (4 pulse sequence) Unit alarm
Cause Microwave activation (walk test) PIR activation (walk test) Warm-up period after power-up Replace Unit
Walk test across the pattern at its farthest edge, then several times closer to the detector. Start walking from outside of the intended protection area, and observe the tri-color LED. The edge of the pattern is determined by the first green, PIR activation of the LED (or the first red activation if the yellow microwave LED activates first). Walk test from the opposite direction to determine both boundaries. The center of the pattern should be pointed toward the center of the intended protection area. The pattern may be moved 10 horizontally by rotating the lens window left or right.
If the detector experiences a Microwave or PIR self-test failure, it is in need of replacement. NOTE: During walk testing, the LED will light for the first technology (microwave or PIR) and then light red to indicate a detector alarm. The LED will not indicate activation of the second technology by lighting its color.
NOTE:
6.0
6.1
Feature Selection
LED On/Off Pins
Off
On
Slowly bring your arm up and into the pattern to mark the lower boundary on PIR alarm. Perform this task at 10 to 20 ft. (3 to 6 m) from the unit. Repeat from above for the upper boundary. The center of the pattern should not be tilted upward.
The ON position allows operation of the tri-color LED. If LED indication is not desired after setup and walk tests are completed, place in the OFF position. The OFF position does not prevent the LED from indicating supervision trouble conditions.
Page 2
P/N: 29703J
2003 Detection Systems, Inc. All rights reserved.
DS860 Series Installation Instructions
NOTE: If desired coverage cannot be achieved, try angling the coverage pattern up or down to assure the pattern is not aimed too high or low. The angle of the PIR pattern may be vertically positioned between -10 and +2 by loosening the Vertical Adjust screw and sliding the circuit board up or down. Moving the board up will angle the pattern downward. Tighten the screw snug when positioning is completed.
9.0
Maintenance
At least once a year, the range and coverage should be verified. To ensure continual daily operation, the end user should be instructed to walk through the far end of the coverage pattern. This ensures an alarm output prior to arming the system.
10.0 Coverage Patterns
The DS860 has a standard broad coverage pattern or an optional long-range coverage pattern. The protected coverage area is where the microwave and PIR patterns overlap. An optional Look Down lens is located under the detector. This lens must be unmasked before it is operational. Use caution to remove the black mask only. Do not attempt to remove the white lens assembly. The Look Down lens is not recommended for installations containing pets or small animals. The Look Down zone is shown in black on the Coverage Pattern drawings.
7.2
NOTE:
Establishing Microwave Coverage
It is important to wait one minute after removing/replacing the cover so the microwave portion of the detector can settle, and to wait at least ten seconds between the following walk testing procedures.
The tri-color LED should be OFF before walk testing. Walk test across the pattern at the intended coverages farthest end. Start walking from outside the intended protection area and observe the tri-color LED. The edge of the microwave pattern is determined by the first yellow, microwave activation of the LED (or the first red activation if the green PIR LED activates first). If adequate range can not be reached, increase the Microwave Range Adjust slightly. Continue walk testing (waiting one minute after removing/replacing the cover) and adjusting the range until the farthest edge of desired coverage has been accurately placed. Do not adjust the microwave range higher than required. Doing so will enable the detector to catch movement outside of the intended coverage pattern.
Standard Broad Coverage
0 Meters 3 30 TOP VIEW 20 6 9 12 15 18 9
A J
B C
6
10
NOTE:
N Q R P M O
K L
D E F G H
0 Feet
0Meters
Walk test the unit from all directions to determine all the Microwave pattern boundaries. Wait at least ten seconds between walk tests.
10
7.3
Establishing Detector Coverage
The tri-color LED should be OFF before walk testing. Walk test the unit from all directions to determine the detection boundaries. A detector alarm is signaled by the first red activation of the tri-color LED after an initial green or yellow activation.
20
I
30 0 Feet 10 20 30 40 SIDE VIEW 10 ft. 7.5 ft. 0 Meters 3 6 9 12
9 50 60
8.0
Supervision Features
PIR/Microwave: The complete circuit operation of these subsystems is checked approximately every 24 hours. If the PIR or MW subsystem fails, the tri-color LED will flash red 4 times per cycle and the unit should be replaced. Default: If the microwave subsystem fails, the detector will default to PIR technology protection. The PIR signal sensitivity will automatically change from INT to STD.
15
18
The supervision features function as follows:
3 Meters 2.3 m
A-I
0 ft. Look-Down 0 Feet
Q, R 10
N-P
20 30
J-M
40 50 60
-5
DS860 Series Installation Instructions 2003 Detection Systems, Inc. All rights reserved.
Page 3
P/N: 29703J
Long Range Barrier Coverage
Meters 3 0 5 0 5 10 0 Feet Meters 3 0 10 7.5 20 30 40 50 60 70 80 90 100 TOP VIEW 6 9 12 15 18 21 24 27 30 1.5 0 1.5
SIDE VIEW 6 9 12 15 18 21 24 27 30 3 Meters 2.3
D 0 10 Look-Down 0 Feet
C
20 30 40
B
50 60 70 80 90
-3
100
10.1 Pattern Masking
The PIR coverage pattern may be masked using masking tape or electrical tape on the inside (grooved side) of the lens to cover the appropriate pattern areas as shown in the following illustrations. Always walk test for the desired coverage after masking.
A B CD E F G H I N J Q K O L R M P
DS860 Standard Lens
A B C D
Optional Long Range Barrier Lens
NOTE:
Masking only eliminates the PIR portion of the coverage and has no effect on the microwave pattern.
2003 Detection Systems, Inc. 130 Perinton Parkway, Fairport, New York, USA 14450-9199 (585) 223-4060 (888) 289-0096 Fax: (585) 223-9180
12/03 DS860 Series Installation Instructions P/N: 29703J