TECHNICAL BULLETIN
8311-TB
09/11
MODELS 8311HP
AND 8311LP
BACK PRESSURE / RELIEF REGULATORS
The Models 8311HP and 8311LP are high capacity, self-contained back pressure/relief regulators with a
double-seat design. These units are utilized to control
inlet (upstream) pressure between 1 and 200 psig (.0713.8 Barg). Available in two inlet pressure designs; LP
- larger diaphragm design for relief pressures up to 30 psig
(2.1 Barg), and HP - smaller diaphragm design for relief
pressures up to 200 psig (13.8 Barg).
FEATURES
Model 8311LP
High
Capacity:
The highest capacity back pressure
regulators Cashco manufactures due to
dual ports.
High
Stability:
Outstanding operation resulting from balanced design which maximizes opposing
plug forces, even at very low pressure
drops. Diaphragm isolated from fluid
velocity effects.
Heavy
Guiding:
Plug is top and bottom guided with hardened stem guides.
Broad
Setpoint
Range:
8311LP: 1-30 psig (.07-2.1 Barg)
8311HP: 10-200 psig (.69 - 13.8 Barg)
High
Pressure
Drop
Capability:
Up to 260 psid.
APPLICATIONS
Designed for controlling a wide range of fluids including air, inert gases, chemicals, water, fuel oils and
steam. See Table 4 for more information.
CAUTION
This is not a safety device and must not be substituted
for a code approved pressure safety relief valve or a
rupture disc.
STANDARD/GENERAL SPECIFICATIONS
Variations:
LP- Low Pressure variation, larger
diaphragm area.
HP - High Pressure variation,
smaller diaphragm area.
Body Sizes:
1-1/2", 2", 2-1/2", 3" and 4"
(DN40,50,65,80, and 100)
NOTE: Refer to OPTION SPECIFICATIONS for alternative designs, and to the TECHNICAL SPECIFICATIONS
tables for a more complete description of the above
specifications.
End Connections: NPT - 1-1/2" and 2" (DN40 and 50)
for CI and CS only.
125 # FF - 150 # RF flanges - all sizes.
250 # RF - 300 # RF flanges - all sizes.
Body & Spring
Chamber
Materials:
HP -CI/DI, CS/CS
LP -CI/CI,CS/CS
CI = Cast Iron
DI - Ductile Iron
CS = Cast Carbon Steel
Inlet Pressure:
LP Variation - up to 39 psig (2.69 Barg).
HP Variation - up to 260 psig (17.93 Barg).
Inlet
Temperature:
-20 to 450F (-29 to +232C)
Gaskets:
Flat gaskets - Graphite/ NBR,
TFE/AL-Silicate.
O-ring - TFE.
Seat Leakage:
ANSI B16.104, Class II.
Trim Design:
316 SST, metal seated, balanced,
double ported. Three material combination choices.
Capacities:
Up to 100 Cv.
Painting:
Standard: All non-corrosion resistant
portions to be painted with corrosion
resistant epoxy paint per Cashco Spec
#S-1606.
Alternate: See Opt-95 or -95OS.
Figure 1: Model 8311HP, metal seated.
(NOTE: Model 8311LP has larger diaphragm area.)
OPTION SPECIFICATIONS
Option -1:
Option -15:
CLOSING CAP. Used to prevent
tampering with the set point pressure.
Available on all spring chamber materials. Consists of a ductile iron closing
cap, a sealing gasket, a sealing lock
nut on the adjusting screw, and a 1/4"
NPT female tapped spring chamber
vent hole.
STELLITED SEATS. Stellited seating surfaces on metal seating portions of plug and on both seat rings.
See Table 1 for maximum allowable
pressure drops.
Option -25:
TAPPED VENT. 1/4" NPT (DN8)
tapped opening in spring chamber for
piping vent to remote location in event
of diaphragm failure.
Option -25P:
PLASTIC RAIN PROOF BUG VENT.
(includes Opt-25).
Option -25S:
SST RAIN PROOF BUG VENT.
(includes Opt-25).
Option -56:
SPECIAL CLEANING. Cleaned per
Cashco Specification #S-1542.
Utilize when cleanliness level better
8311-TB
Option-80:
than normal is required and unit is
NOT FOR OXYGEN SERVICE.
Option -95:
HIGH INLET PRESSURE CONSTRUCTION. Utilized for 130-200
psig (9.0-13.8 Barg) inlet pressure
spring range. ONLY AVAILABLE
WITH HP VARIATION. Special
construction includes a diaphragm
ring to reduce effective diaphragm
area and serve as a travel stop in
case of over-pressurization.
EPOXY PAINT. Special epoxy
painting of all non-corrosion resistant external surfaces per Cashco
Spec #S-1547. Utilized in harsh
atmospheric conditions.
Option -95OS:
EPOXY PAINT. Special epoxy
painting of all non-corrosion resistant external surfaces per Cashco
Spec #S-1687 for OFFSHORE
installations.
TECHNICAL SPECIFICATIONS
TABLE 1
MAXIMUM ALLOWABLE PRESSURE DROPS
Fluid
NonCavitating
Liquid
Maximum Recommended
Operating Pressure Drop
Model 8311LP
Model 8311HP
Clean Fluid
Unclean Fluid
All Fluid Qualities
Industrial Quality
Pipeline Quality
psid
(Bard)
psid
(Bard)
psid
(Bard)
150
(10.3)
200
(13.8)
100
(6.9)
150
Steam
260
Consult
Factory
Cavitating
Liquids
Gas
(10.3)
(17.9)
150
Consult
Factory
(10.3)
N/R
200
(13.8)
260
(17.9)
150
(10.3)
200
(13.8)
260
(17.9)
260
(17.9)
150
(10.3)
150
(10.3)
200
(13.8)
260
(17.9)
NR
150
(10.3)
Option
Number
Trim
Designation
Number
None
Stellited
Option-15
All
Stellited
S1 Only
Option-15
None
Stellited
Option-15
None
Stellited
Option-15
All
S1 Only
TABLE 2
DESIGN PRESSURE-TEMPERATURE MATERIAL LIMITS
MODEL 8311LP
Material Specifications
Description
Abbreviation
(Body/Sp.Ch.)
ASTM
No.
Cast Iron
(CI/CI)
A126
Class B
Cast Carbon
Steel
(CS/CS)
A216
Grade
WCB
8311-TB
End
Connection
125# Flgd.,
250# Flgd.,
or NPT
150# Flgd.,
300# Flgd.,
or NPT
Inlet
Outlet Diaphragm Design
Metal
Composition
Pressure
Temperature
F (C)
psig (Barg)
S1 Trim
Temp F (C)
S5 Trim
S40 Trim
Temp F (C) Temp F (C)
39
(2.69)
-20 to +450
(-29 to +232)
-20 to +450
(-29 to +232)
-20 to +300
(-29 to +149)
-20 to +180
(-29 to +83)
39
(2.69)
-20 to +450
(-29 to +232)
-20 to +450
(-29 to +232)
-20 to +300
(-29 to +149)
-20 to +180
(-29 to +83)
TABLE 3
DESIGN PRESSURE-TEMPERATURE MATERIAL LIMITS
MODEL 8311HP
Material Specifications
Description
Abbreviation
(Body/Sp.Ch.)
ASTM
No.
End
Connection
Pressure
psig (Barg)
200 (13.8)
Cast Iron/
Ductile Iron
(CI/DI)
A126
Class B/
A395,
GR.
60-40-18
125#
Flanged
250#
Flanged
or NPT
190
175
165
140
125
(13.1)
(12.1)
(11.4)
(9.7)
(8.6)
260 * (17.9)
250 * (17.2)
& Lower
Cast Carbon
Steel
(CS/CS)
A216
Grade
WCB
300#
Flanged
or NPT
Temperature
F (C)
-20 to +150
(-29 to +66)
200 (94)
250 (121)
300 (149)
400 (205)
450 (232)
-20 to +400
(-29 to +205)
450 (232)
S1 Trim
S5 Trim
S40 Trim
-20 to +150
(-29 to +66)
200 (94)
250 (121)
300 (149)
400 (205)
450 (232)
-20 to +150
(-29 to +66)
200 (94)
250 (121)
-20 to +150
(-29 to +66)
-20 to +450
(-29 to +232)
-20 to +300
(-29 to +149)
-20 to +180
(-29 to +83)
-20 to +300
(-29 to +149)
-20 to +180
(-29 to +83)
-20 to +300
(-29 to +149)
-20 to +180
(-29 to +83)
230 * (15.9)
-20 to +200
(-29 to +94)
300 (149)
200 (13.8)
400 (205)
185 (12.8)
& Lower
450 (232)
-20 to +450
(-29 to +232)
260 * (17.9)
-20 to +450
(-29 to +232)
-20 to +450
(-29 to +232)
260 * (17.9)
150#
Flanged
Outlet Diaphragm Design
Metal
Composition
Inlet
-20 to +400
(-29 to +205)
300 (149)
-20 to +180
(-29 to +83)
* Max Inlet Pressure for S5 Trim is 200 psig (13.8 barg).
8311-TB
TABLE 4
APPLICATIONS
Fluid
Recommended Construction
Air or Industrial
Gases
Metal Seat & Composition Diaphragm
Metal Seat & Diaphragm
Metal Seat & Composition Diaphragm
Metal Seat & Diaphragm
Metal Seat & Composition Diaphragm
Metal Seat & Diaphragm
Metal Seat & Composition Diaphragm
Metal Seat & Diaphragm
Trim Designation
Number
S40
S1
S5, S40
S1
S5, S40
S1
S40
S1
Metal Seat & Diaphragm
S1
Chemicals
Hydrocarbon Gas
or Liquids
Water and
Condensate
Steam - Saturated
or Superheated
In accordance with ASME B31.3 process piping, do not use Cast Iron Body for hydrocarbon or flammable
fluid service with inlet pressures greater than 150 Psig (10.3 Barg) or temperatures greater than 300 F (149 C).
TABLE 5
STAINLESS STEEL MATERIAL COMBINATIONS
Part
Diaphragm
Plug *
Seat Rings
Stem
Groove Pin
Stem Guides
Bonnet Plug
Pusher Plate
Pusher Plate Nut
Diaphragm Casing O-ring
Stem Bushing
Bonnet Nut
SST Trim Designation Number
Metal Diaphragm
Composition Diaphragm
S1
S5
S40
302 SST
Fluorocarbon Elastomer
Neoprene
316 SST
316 SST
316 SST
316 SST
316 SST
316 SST
316 SST
316 SST
316 SST
18-8 SST
18-8 SST
18-8 SST
Hardened 440C SST
Hardened 440C SST
Hardened 440C SST
**
**
**
303 SST
303 SST
303 SST
Steel
Steel
Steel
TFE
TFE
TFE
303 SST
303 SST
303 SST
Steel
Steel
Steel
* Plug Assembly consists of factory-joined plug, stem and groove pin.
** Same as body material.
8311-TB
TABLE 6
STEEL RANGE SPRINGS
METAL OR COMPOSITION DIAPHRAGMS
ALL SIZES
Construction
Standard
Option-80
Range Spring
LP Variation
HP Variation
psig
(barg)
psig
(Barg)
1-4 *
(.07-.28)
10 - 40
(.69-2.8)
3 - 10
(.21-.69)
30 - 100
(2.1-6.9)
8 -30
(.55-2.1)
75 - 145
(5.2-10.0)
N/A
130 - 200
(9.3-13.8)
* Composition Diaphragm Only
TABLE 7
PRESSURE LIMITS SAFETY RELIEF VALVE
SIZING & SETPOINT
Range Spring
Variation
LP
HP
psig
(Barg)
1-4
3 - 10
8 -30
10 - 40
30 - 100
75 - 145
130 - 200
(.07 - .28)
(.21 - .69)
(.55 - 2.1)
(.69 - 2.8)
(2.1 - 6.9)
(5.2 - 10.0)
(9.3 - 13.8)
Maximum Cv With Valve
Plug Wide Open
Body Size
Diaphragm
Material
*Emergency
Over-Pressure
(psig)
All
1.5 x UVRS*
27
40
All
1.5 x UVRS*
27
40
1-1/2"
(DN40)
2"
2-1/2"
(DN50) (DN65)
3"
(DN80)
4"
(DN100)
55
78
100
55
78
100
UVRS = Upper Value of Range Spring; i.e. 130-200 psig range spring, value would be 200 psig. Emergency
over-pressure quantity must include the pressure build of the selected safety relief valve. DO NOT EXCEED
VALUES IN TABLES 2 or 3.
8311-TB
TABLE 8
Model 8311 - LP VARIATION
CAPACITY TABLES - Cv METAL DIAPHRAGM
Set Point (Inlet)
Pressure, P1
(psig)
5
101
15
20
25
30
1
1-1/2" (DN40) Body
% Build
10%
20%
30%
8.5
15.1
22.5
2.9
5.6
10.0
4.2
8.2
12.5
6.1
11.5
16.1
8.1
14.7
21.7
10.9
18.2
23.5
2" (DN50) Body
% Build
10%
20%
30%
10.2
19.7
29.9
3.3
6.7
12.0
4.8
10.0
16.0
7.1
14.1
21.9
9.8
18.7
30.1
13.2
25.1
32.6
2-1/2" (DN65) Body
% Build
10%
20%
30%
12.0
22.9
37.5
3.9
7.5
13.2
5.5
11.5
18.0
8.1
16.5
25.5
11.6
22.0
36.0
15.5
29.2
41.0
3" (DN80) Body
% Build
10%
20%
30%
13.9
26.1
43.1
4.6
8.7
16.0
6.8
13.2
21.0
9.5
19.0
29.0
13.2
25.0
42.4
17.9
33.5
46.8
4" (DN100) Body
% Build
10%
20%
30%
19.0
36.1
59.8
6.3
12.0
21.7
8.1
17.9
28.5
13.1
26.4
40.7
18.0
30.0
57.5
24.5
45.9
65.0
Utilizes 8-30 psig range spring.
TABLE 9
Model 8311 - LP VARIATION
CAPACITY TABLES - Cv COMPOSITION DIAPHRAGM
Set Point (Inlet)
Pressure, P1
(psig)
2
5
102
15
20
25
30
2
1-1/2" (DN40) Body
% Build
10%
20%
30%
16.8
25.7
26.2
14.0
23.6
26.2
5.5
10.8
15.5
7.5
14.0
20.0
10.0
27.8
23.7
13.3
22.3
26.2
17.5
25.8
26.2
2" (DN50) Body
% Build
10%
20%
30%
22.0
35.9
39.3
18.0
32.9
38.0
6.3
13.0
20.0
8.9
18.0
37.3
12.2
23.8
33.1
16.9
31.2
37.2
23.5
36.5
39.3
2-1/2" (DN65) Body
% Build
10%
20%
30%
25.3
46.2
52.8
21.1
41.2
50.0
7.8
15.3
22.7
10.5
21.2
32.3
13.8
27.8
41.9
19.7
37.8
48.3
27.2
47.3
53.6
3" (DN80) Body
% Build
10%
20%
30%
29.0
58.4
73.2
24.0
47.7
67.0
8.8
27.4
26.4
12.2
24.2
36.8
16.2
32.2
48.8
22.5
43.7
53.7
31.7
61.3
75.0
4" (DN100) Body
% Build
10%
20%
30%
40.5
81.2
99.0
33.1
66.5
94.4
12.2
23.9
36.5
16.9
33.2
50.7
22.2
44.3
67.9
31.2
60.3
90.5
43.3
86.1
99.8
Utilizes 8-30 psig range spring
TABLE 10
Model 8311 - HP VARIATION
CAPACITY TABLES - Cv METAL DIAPHRAGM
Set Point (Inlet)
Pressure, P1
(psig)
10
15
25
35
50
75
100
150
200
1-1/2" (DN40) Body
% Build
10%
20%
30%
2.0
4.2
7.5
3.0
8.0
12.0
7.5
14.0
19.0
11.5
19.7
25.2
6.2
11.7
16.7
8.5
15.5
21.0
8.7
18.0
21.2
11.4
19.5
25.0
14.0
23.5
26.0
2" (DN50) Body
% Build
10%
20%
30%
2.6
6.3
9.0
4.0
9.2
14.5
8.7
18.0
26.5
14.0
27.5
35.7
7.3
14.8
22.0
10.0
20.3
29.0
10.5
21.0
29.5
13.8
27.1
35.5
18.7
33.4
38.5
2-1/2" (DN65) Body
% Build
10%
20%
30%
3.0
6.8
10.5
5.0
11.2
16.5
10.0
21.0
31.3
16.5
32.3
45.7
8.0
16.8
25.2
11.2
23.5
35.0
12.0
23.8
36.0
16.2
31.9
45.0
21.2
41.3
50.2
3" (DN80) Body
% Build
10%
20%
30%
4.0
7.5
12.0
6.0
12.5
19.0
11.7
23.7
36.5
18.7
37.2
55.7
9.5
19.0
28.7
13.0
27.0
40.5
13.7
27.2
41.3
18.5
36.3
55.5
24.4
48.5
67.5
4" (DN100) Body
% Build
10%
20%
30%
5.0
11.0
16.7
8.5
17.5
23.5
18.5
32.5
48.0
26.5
51.5
78.7
13.0
26.8
39.5
18.0
36.5
55.7
18.7
37.5
56.5
25.0
50.7
76.5
33.7
67.5
95.0
TABLE 11
Model 8311 - HP VARIATION
CAPACITY TABLES - Cv COMPOSITION DIAPHRAGM
Set Point (Inlet)
Pressure, P1
(psig)
10
15
25
35
50
75
100
150
200
8311-TB
1-1/2" (DN40) Body
% Build
10%
20%
30%
6.0
11.2
16.2
7.5
13.8
19.5
10.5
19.0
25.0
16.0
25.4
26.2
10.5
18.7
24.5
15.2
24.7
26.2
12.1
21.3
26.0
17.8
26.2
26.2
21.2
26.2
26.2
2" (DN50) Body
% Build
10%
20%
30%
7.0
14.0
21.5
9.1
18.7
27.2
13.0
26.3
34.8
21.4
35.7
39.0
13.0
26.1
34.2
20.2
34.7
38.7
15.7
29.4
36.9
24.4
37.0
39.3
29.1
38.8
39.5
2-1/2" (DN65) Body
% Build
10%
20%
30%
8.0
16.2
24.8
11.2
21.2
32.1
15.0
31.0
44.3
24.5
45.7
52.4
15.0
30.0
43.7
22.9
43.7
51.2
17.7
36.0
47.5
28.0
37.9
53.8
35.1
51.5
55.0
3" (DN80) Body
% Build
10%
20%
30%
9.2
18.7
28.7
12.5
24.1
36.5
17.6
35.5
53.5
28.1
56.5
72.2
17.4
34.8
52.1
26.5
52.8
70.0
20.4
41.2
61.3
32.4
62.5
75.2
40.2
70.8
78.0
4" (DN100) Body
% Build
10%
20%
30%
13.0
26.2
39.1
17.0
33.5
50.8
24.0
48.8
73.7
38.8
78.7
98.2
24.0
47.5
72.2
36.7
72.8
97.5
28.0
57.0
86.0
44.2
88.5
100.0
55.1
97.5
100.0
TABLE 12
MODEL 8311 - HP VARIATION
WATER CAPACITY - GPM
S.G. = 1.0 T = 60F FL = 0.88
All Sizes - COMPOSITION DIAPHRAGM ONLY
Outlet Set Point
Pressure Pressure
(psig)
(psig)
10
15
ATM
25
35
10
15
5
25
35
50
15
25
10
35
50
75
25
35
15
50
75
100
35
50
25
75
100
150
NOTE:
1-1/2" (DN40) Body
% Build
10%
20%
30%
19.9
38.8
58.4
30.5
58.5
86.1
55.1
104.1
CAV
CAV
CAV
CAV
14.7
29.6
45.8
25.4
49.8
74.3
49.8
95
131.1
92.6
154.5
CAV
CAV
CAV
CAV
19.1
39
60.1
43.9
85
118.6
85.4
143.7 156.1
70.4
CAV
CAV
CAV
CAV
CAV
37.1
73.6
104.6
77.6
132
144.7
66.4
125.4
CAV
124.9
CAV
CAV
CAV
CAV
CAV
58.8
104.7 118.6
57.5
110.6
155
115.3 HI VEL CAV
111.6
CAV
CAV
CAV
CAV
CAV
2" (DN50) Body
% Build
10%
20%
30%
23.2
48.5
77.5
37
79.3
120.1
68.2
144.1
CAV
CAV
CAV
CAV
17.1
37
60.8
30.9
67.4
103.6
61.7
131.5 182.5
123.9 217.2
CAV
CAV
CAV
CAV
23.2
52.9
83.8
54.4
117.6 165.1
114.2 201.9 232.4
87.2
CAV
CAV
CAV
CAV
CAV
46
101.9 145.6
103.7 185.5 215.4
82.2
175.1
CAV
166
CAV
CAV
CAV
CAV
CAV
78.6
147.2 176.6
71.2
154.4 216.3
153.2 279.8
CAV
144.7
CAV
CAV
CAV
CAV
CAV
2-1/2" (DN65) Body
% Build
10%
20%
30%
26.5
56.1
89.4
45.5
89.9
141.7
78.7
169.8
CAV
CAV
CAV
CAV
19.6
42.9
70.1
38
76.4
122.2
71.2
155
232.3
141.8
278
CAV
CAV
CAV
CAV
28.6
60
98.9
62.7
138.6 210.1
130.8 258.5 312.2
100.6
CAV
CAV
CAV
CAV
CAV
53
120.1 185.3
118.8 237.5 289.4
94.9
201.2
CAV
188.1
CAV
CAV
CAV
CAV
CAV
90
188.4 237.3
82.2
177.5 276.4
173.6 352.3
CAV
163.2
CAV
CAV
CAV
CAV
CAV
3" (DN80) Body
% Build
10%
20%
30%
30.5
64.8
103.5
50.8
102.2 161.2
92.3
194.4
CAV
CAV
CAV
CAV
22.5
49.5
81.2
42.4
86.9
139
83.5
177.5 280.6
162.6 343.7
CAV
CAV
CAV
CAV
31.9
68.2
112.5
73.6
158.8 253.8
150
319.6 430.2
116.7
CAV
CAV
CAV
CAV
CAV
62.2
137.5 223.8
136.2 293.6 398.7
110
233.4
CAV
217.7
CAV
CAV
CAV
CAV
CAV
103.2
233
326.9
95.3
205.9 329.5
200.9 425.7
CAV
188.1
CAV
CAV
CAV
CAV
CAV
Where CAV is indicated within the above capacity tables, the water has reached full cavitation, and flow is choked.
Where HI VEL is indicated, the flow has reached or exceeded the velocities to the right based on Schedule 40 pipe.
4" (DN100) Body
% Build
10%
20%
30%
43.1
90.8
141
69.1
142.1 224.3
125.9 267.3
CAV
CAV
CAV
CAV
31.8
69.3
110.6
57.6
120.8 193.4
113.8
244
386.5
224.6 478.7
CAV
CAV
CAV
CAV
43.3
94.8
156.6
100.4 218.2 349.6
207.1 445.2 585.1
161
CAV
CAV
CAV
CAV
CAV
84.9
189
308.3
188.1 408.9 542.3
151.8 318.6
CAV
301.5
CAV
CAV
CAV
CAV
CAV
142.6 324.5 444.6
131.5
281
456.6
278.3 586.9
CAV
258.1
CAV
CAV
CAV
CAV
CAV
SIZE
1-1/2"
2"
2-1/2"
3"
4"
MAX. VEL
25 fps
27 fps
29 fps
31 fps
35 fps
8311-TB
TABLE 13
MODEL 8311 - HP VARIATION
AIR CAPACITY - SCFH
S.G. = 1.0 T = 60F FL = 0.88
All Sizes - COMPOSITION DIAPHRAGM ONLY
Outlet Set Point
Pressure Pressure
(psig)
(psig)
ATM
10
15
25
2" (DN50) Body
2-1/2" (DN65) Body
3" (DN80) Body
% Build
% Build
% Build
% Build
10%
20%
30%
10%
20%
30%
10%
20%
30%
10%
20%
4" (DN100) Body
% Build
30%
10%
20%
30%
10
4950
9590
14400
5770
11990
19110
6600
13880
22040
7590
16020
25510
10720
22440
34750
15
7510
14480
21400
9110
19620
29850
11210
22240
35220
12510
25280
40050
17020
35150
55740
25
14220
27260
37880
17610
37740
52730
20320
44480
67120
23840
50940
81060
32510
70020 111660
35
27340
46250
50650
36560
65010
75400
41860
83220 101310 48010 102890 139590 66290 143310 189860
50
23520
44890
SONIC
29110
62650
87580
33590
72010 111910 38970
83530 133420 53750 114010 184900
75
47500
SONIC SONIC
63120
SONIC SONIC
71560
SONIC SONIC
82810 177720 SONIC 114680 245040 351690
100
48530
SONIC SONIC
62970
SONIC SONIC
70990
SONIC SONIC
81820 178500 SONIC 112310 246960 SONIC
150
SONIC SONIC SONIC SONIC SONIC SONIC SONIC SONIC SONIC 187360 SONIC SONIC 255600 SONIC SONIC
200
SONIC SONIC SONIC SONIC SONIC SONIC SONIC SONIC SONIC SONIC SONIC SONIC SONIC SONIC SONIC
10
1-1/2" (DN40) Body
4840
9380
14080
5650
11730
18690
6450
13570
21560
7420
15670
24950
10480
21950
33990
55740
15
7510
14480
21400
9110
19620
29850
11210
22240
35220
12510
25280
40050
17020
35150
25
14220
27260
37880
17610
37740
52730
20320
44480
67120
23840
50940
81060
32510
70020 111660
35
27340
46250
50650
36560
65010
75400
41860
83220 101310 48010 102890 139590 66290 143310 189860
50
23520
44890
62740
29110
62650
87580
33590
72010 111910 38970
75
47500
SONIC SONIC
63120 116800 SONIC
71560 147090 SONIC
82810 177720 252490 114680 245040 351690
100
48530
SONIC SONIC
62970
70990 155970 SONIC
81820 178500 SONIC 112310 246960 400260
150
SONIC SONIC SONIC SONIC SONIC SONIC 161920 SONIC SONIC 187360 SONIC SONIC 255600 SONIC SONIC
200
SONIC SONIC SONIC SONIC SONIC SONIC SONIC SONIC SONIC SONIC SONIC SONIC 416370 SONIC SONIC
SONIC SONIC
83530 133420 53750 114010 184900
15
6680
12890
19050
8110
17470
26570
9980
19800
31360
11140
22510
35660
15150
31290
25
14190
27200
37790
17570
37650
52600
20270
44380
66960
23790
50820
80870
32440
69860 111400
49630
35
27340
46250
50650
36560
65010
75400
41860
83220 101310 48010 102890 139590 66290 143310 189860
50
23520
44890
62740
29110
62650
87580
33590
72010 111910 38970
75
47500
83140
94500
63120 116800 139590 71560 147090 184680 82810 177720 252490 114680 245040 351690
100
48530
92280
SONIC
62970 127380 SONIC
150
SONIC SONIC SONIC 141100 SONIC SONIC 161920 SONIC SONIC 187360 SONIC SONIC 255600 554500 SONIC
200
SONIC SONIC SONIC SONIC SONIC SONIC SONIC SONIC SONIC 303770 SONIC SONIC 416370 SONIC SONIC
25
13300
25490
35420
16470
35290
49310
19000
41600
35
27180
45990
50360
36350
64630
74970
41620
82740 100720 47730 102290 138780 65910 142480 188760
50
23520
44890
62740
29110
62650
87580
33590
72010 111910 38970
75
47500
83140
94500
63120 116800 139590 71560 147090 184680 82810 177720 252490 114680 245040 351690
100
48530
92280
SONIC
62970 127380 171740 70990 155970 221070 81820 178500 285300 112310 246960 400260
150
102930 SONIC SONIC 141100 SONIC SONIC 161920 237460 SONIC 187360 391600 SONIC 255600 554500 674830
200
SONIC SONIC SONIC SONIC SONIC SONIC 265240 SONIC SONIC 303770 SONIC SONIC 416370 SONIC SONIC
35
23200
39250
42980
31030
55160
63980
35520
70620
40740
87300 118450 56250 121610 161110
50
23000
43900
61370
28480
61280
85670
32860
70430 109470 38120
81700 130510 52580 111520 180860
75
47500
83140
94500
63120 116800 139590 71560 147090 184680 82810 177720 252490 114680 245040 351690
92280 121010 62970 127380 171740 70990 155970 221070 81820 178500 285300 112310 246960 400260
83530 133420 53750 114010 184900
70990 155970 221070 81820 178500 285300 112310 246960 400260
62770
85970
22300
47630
75800
30400
65480 104420
83530 133420 53750 114010 184900
100
48530
150
102930 SONIC SONIC 141100 231830 SONIC 161920 237460 SONIC 187360 391600 507470 255600 554500 674830
200
SONIC SONIC SONIC 219900 SONIC SONIC 265240 SONIC SONIC 303770 SONIC SONIC 416370 799550 884450
NOTE: Where SONIC is indicated within the above capacity tables, outlet velocity with Schedule 40 pipe has reached sonic velocity of 1118 fps. Additional flow
cannot be obtained, and pipeline velocity is in excess of customary pipe velocity design limits. Flow will be approximately the last indicated value in the
column above SONIC.
8311-TB
TABLE 14
MODEL 8311 - HP VARIATION
STEAM CAPACITY - LBS/HR
S.G. = Actual T = Saturated FL = 0.88
All Sizes - METAL DIAPHRAGM
Outlet
Set Point
Pressure Pressure
(psig)
(psig)
ATM
10
15
25
1-1/2" (DN40) Body
2" (DN50) Body
2-1/2" (DN65) Body
3" (DN80) Body
% Build
% Build
% Build
% Build
10%
20%
30%
10%
20%
30%
10%
20%
30%
10%
20%
4" (DN100) Body
% Build
30%
10%
20%
30%
10
77
161
287
100
241
345
115
261
402
153
287
460
192
421
640
15
144
385
577
192
442
697
240
539
793
288
601
914
409
841
1130
25
489
912
HI VEL
567
1173
1727
652
1369
2040
762
1545
2379
1206
2118
3128
35
946
HI VEL
HI VEL
1152
HI VEL
HI VEL
1357
2657
HI VEL
1538
3060
HI VEL
2180
4236
6473
50
658
HI VEL
HI VEL
774
1570
HI VEL
849
1782
2673
1008
2016
3045
1379
2843
4190
75
HI VEL
HI VEL
HI VEL
1457
HI VEL
HI VEL
1631
HI VEL
HI VEL
1894
3933
HI VEL
2622
5317
HI VEL
100
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
2223
HI VEL
HI VEL
2538
HI VEL
HI VEL
3464
6947
HI VEL
150
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
6583
HI VEL
HI VEL
200
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
10
62
130
232
80
195
278
93
210
324
124
232
371
154
340
516
15
132
353
530
177
406
640
221
495
729
265
552
839
375
773
1038
25
477
891
1209
554
1145
1686
636
1336
1991
744
1508
2322
1177
2068
3054
35
921
HI VEL
HI VEL
1121
2202
HI VEL
1321
2587
HI VEL
1498
2979
4461
2122
4124
6303
4190
50
658
1241
HI VEL
774
1570
2334
849
1782
2673
1008
2016
3045
1379
2843
75
1238
HI VEL
HI VEL
1457
HI VEL
HI VEL
1631
3423
HI VEL
1894
3933
HI VEL
2622
5317
8114
100
HI VEL
HI VEL
HI VEL
1945
HI VEL
HI VEL
2223
HI VEL
HI VEL
2538
5039
HI VEL
3464
6947
HI VEL
150
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
4871
HI VEL
HI VEL
6583
HI VEL
HI VEL
200
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
15
104
278
416
139
319
503
173
389
572
208
434
659
295
607
815
25
452
843
1145
524
1084
1597
602
1265
1886
705
1428
2199
1115
1958
2892
35
908
1556
HI VEL
1106
2172
2820
1303
2552
3610
1477
2939
4400
2093
4068
6217
4085
50
641
1210
1727
755
1531
2275
827
1737
2606
982
1965
2968
1344
2772
75
1238
HI VEL
HI VEL
1457
2957
HI VEL
1631
3423
HI VEL
1894
3933
5900
2622
5317
8114
100
1612
HI VEL
HI VEL
1945
HI VEL
HI VEL
2223
4409
HI VEL
2538
5039
HI VEL
3464
6947
10466
150
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
4265
HI VEL
HI VEL
4871
HI VEL
HI VEL
6583
HI VEL
HI VEL
200
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
11380
HI VEL
HI VEL
25
400
747
1014
465
961
1415
534
1121
1671
625
1265
1949
988
1735
2563
35
873
1496
1913
1063
2088
2711
1253
2452
3470
1420
2824
4229
2012
3910
5975
50
637
1201
1715
750
1520
2259
821
1725
2588
976
1951
2947
1335
2752
4056
75
1238
2258
HI VEL
1457
2957
HI VEL
1631
3423
5098
1894
3933
5900
2622
5317
8114
100
1612
HI VEL
HI VEL
1945
HI VEL
HI VEL
2223
4409
HI VEL
2538
5039
7651
3464
6947
10466
150
HI VEL
HI VEL
HI VEL
3634
HI VEL
HI VEL
4265
HI VEL
HI VEL
4871
HI VEL
HI VEL
6583
13349
HI VEL
200
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
11380
HI VEL
HI VEL
35
703
1204
1541
856
1681
2183
1009
1975
2794
1143
2274
3405
1620
3149
4811
50
601
1135
1620
708
1436
2134
776
1630
2445
922
1843
2784
1261
2600
3832
75
1201
2191
2968
1413
2869
4099
1583
3321
4947
1837
3816
5724
2544
5159
7872
100
1612
HI VEL
HI VEL
1945
3890
HI VEL
2223
4409
6669
2538
5039
7651
3464
6947
10466
150
3002
HI VEL
HI VEL
3634
HI VEL
HI VEL
4265
HI VEL
HI VEL
4871
9558
HI VEL
6583
13349
HI VEL
200
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
HI VEL
8239
HI VEL
HI VEL
11380
HI VEL
HI VEL
NOTE: Where HI VEL is indicated, the flow has reached or exceeded a velocity of Mach 0.35, an accepted limit for expanded steam on the downstream side.
Use of higher velocities normally generate excessive noise levels.
10
8311-TB
TABLE 15
MODEL 8311 - LP VARIATION
WATER CAPACITY - GPM
S.G. = 1.0 T = 60F FL = 0.88
All Sizes - Composition Diaphragm Only
Outlet
Pressure
(psig)
ATM
2.5
7.5
10
NOTE:
Set Point
Pressure
(psig)
2
5
10
15
20
25
30
5
10
15
20
25
30
10
15
20
25
30
10
15
20
25
30
15
20
25
30
1-1/2" (DN40) Body
% Build
10%
20%
30%
24.9
39.8
42.2
32.8
57.8
66.8
18.2
37.4
55.9
30.5
59.4
88.3
46.9
136.2 120.8
69.7
122.1
CAV
100.5
CAV
CAV
24.2
44.2
52.4
16
33.3
50.2
28.1
55.1
82.5
44.2
128.9 114.9
66.5
116.9 143.5
96.6
149.3
CAV
13.5
28.6
43.8
25.4
50.5
76.2
41.2
121.2 108.6
63.1
111.5 137.4
92.6
143.6 152.8
10.3
22.9
36.4
22.5
45.4
69.3
38.1
112.9 101.9
59.5
105.8 131.0
88.4
137.7 147.0
19.1
39.6
61.6
34.6
104.0
94.8
55.6
99.7
124.3
83.9
131.6 141.1
2" (DN50) Body
% Build
10%
20%
30%
32.6
55.6
63.4
42.2
80.6
96.9
20.9
45.0
72.1
36.2
76.4
164.7
57.2
116.6 168.8
88.6
170.9
CAV
135.0
CAV
CAV
31.2
61.6
76.0
18.4
40.1
64.8
33.3
70.9
153.8
53.9
110.4 160.5
84.5
163.6 203.8
129.8 211.3
CAV
15.4
34.4
56.6
30.2
64.9
142.0
50.3
103.7 151.7
80.2
156.0 195.1
124.4 203.2 229.2
11.8
27.6
46.9
26.7
58.3
129.2
46.5
96.7
142.4
75.6
148.0 186.0
118.7 194.9 220.6
22.7
50.9
115.0
42.3
89.1
132.4
70.7
139.5 176.5
112.7 186.1 211.6
2-1/2" (DN65) Body
% Build
10%
20%
30%
37.5
71.6
85.1
49.5
100.9 127.5
25.9
53.0
81.8
42.7
89.9
142.6
64.7
136.2 213.6
103.3 207.0
CAV
156.3
CAV
CAV
36.5
77.1
100.0
22.7
47.2
73.6
39.3
83.5
133.2
60.9
128.9 203.1
98.5
198.2 264.5
150.2 273.8
CAV
19.1
40.5
64.2
35.6
76.4
123.0
56.9
121.2 192.0
93.4
189.0 253.3
143.9 263.4 312.5
14.6
32.5
53.2
31.5
68.7
111.9
52.5
112.9 180.2
88.1
179.3 241.5
137.4 252.5 300.8
26.8
60.0
99.6
47.8
104.0 167.6
82.4
169.0 229.1
130.4 241.2 288.6
3" (DN80) Body
% Build
10%
20%
30%
43.0
90.5
118.0
56.3
116.8 170.8
29.2
94.9
95.2
49.6
102.7 162.5
76.0
157.7 248.8
118.0 239.4
CAV
182.1
CAV
CAV
41.6
89.2
134.0
25.7
84.5
85.5
45.6
95.3
151.7
71.5
149.3 236.6
112.5 229.2 294.1
175.1 354.8
CAV
21.6
72.5
74.7
41.4
87.3
140.1
66.8
140.4 223.6
106.7 218.5 281.6
167.7 341.3 437.3
16.5
58.1
61.9
36.6
78.4
127.5
61.7
130.8 209.9
100.6 207.3 268.5
160.1 327.3 420.9
31.1
68.4
113.4
56.1
120.5 195.2
94.1
195.4 254.7
152
312.6 403.9
Where CAV is indicated within the above capacity tables, the water has reached full cavitation, and flow is choked.
Where HI VEL is indicated, the flow has reached or exceeded the velocities to the right based on Schedule 40 pipe.
TABLE 16
MODEL 8311 - LP VARIATION
AIR CAPACITY - SCFH
S.G. = 1.0 T = 60F FL = 0.88
All Sizes - Composition Diaphragm Only
Outlet Set Point
Pressure Pressure
(psig)
(psig)
2
5
10
ATM
15
20
25
30
5
10
15
2.5
20
25
30
10
15
20
5
25
30
10
15
7.5
20
25
30
15
20
10
25
30
1-1/2" (DN40) Body
% Build
10%
20%
30%
9100
14090 14540
9070
15670 17810
4530
9250
13770
7500
14680 21930
11770 34500 30930
18000 31970 39660
26770 41950 45120
8870
15320 17420
4530
9250
13770
7500
14680 21930
11770 34500 30930
18000 31970 39660
26770 41950 45120
4430
9040
13470
7500
14680 21930
11770 34500 30930
18000 31970 39660
26770 41950 45120
3680
7500
11160
7340
14360 21450
11760 34480 30910
18000 31970 39660
26770 41950 45120
6680
13070 19530
11510 33750 30260
17960 31890 39560
26770 41950 45120
2" (DN50) Body
% Build
10%
20%
30%
11920 19690 21800
11660 21840 25830
5190
11130 17770
8900
18880 40910
14360 29540 43200
22870 44720 56310
35950 59340 67680
11400 21360 25270
5190
11130 17770
8900
18880 40910
14360 29540 43200
22870 44720 56310
35950 59340 67680
5080
10890 17380
8900
18880 40910
14360 29540 43200
22870 44720 56310
35950 59340 67680
4210
9020
14400
8710
18460 40010
14350 29520 43180
22870 44720 56310
35950 59340 67680
7930
16810 36420
14040 28890 42260
22820 44620 56180
35950 59340 67680
2-1/2" (DN65) Body
% Build
10%
20%
30%
13710 25330 29290
13670 27350 33990
6430
13100 20160
10510 22230 35420
16240 34500 54690
26660 54180 73110
41610 76900 92300
13370 26750 33250
6430
13100 20160
10510 22230 35420
16240 34500 54690
26660 54180 73110
41610 76900 92300
6290
12810 19720
10510 22230 35420
16240 34500 54690
26660 54180 73110
41610 76900 92300
5210
10620 16350
10280 21740 34650
16230 34480 54650
26660 54180 73110
41610 76900 92300
9350
19790 31540
15890 33750 53490
26600 54060 72940
41610 76900 92300
3" (DN80) Body
% Build
10%
20%
30%
15720 32020
40610
15550 31660
45550
7250
23460
23450
12210 25380
40360
19070 39960
63690
30450 62640
81280
48490 99660 129150
15210 30970
44550
7250
23460
23450
12210 25380
40360
19070 39960
63690
30450 62640
81280
48490 99660 129150
7090
22950
22940
12210 25380
40360
19070 39960
63690
30450 62640
81280
48490 99660 129150
5880
19020
19010
11940 24820
39480
19050 39940
63650
30450 62640
81280
48490 99660 129150
10870 22590
35930
18650 39090
62300
30380 62500
81090
48490 99660 129150
4" (DN100) Body
% Build
10%
20%
30%
60.1
125.8 159.6
77.6
162.9 240.7
40.5
82.8
131.6
68.6
140.9 223.9
104.1 217.0 346.2
163.6 330.3
CAV
248.7
CAV
CAV
57.3
124.4 188.8
35.6
73.7
118.3
63.2
130.7 209.0
98.0
205.4 329.2
156.0 316.2 495.7
239.1 498.3
CAV
29.9
63.2
103.2
57.3
119.7 193.1
91.5
193.1 311.2
148.0 301.5 474.6
229.1 479.4 581.9
22.8
50.7
85.6
50.7
107.6 175.6
84.5
179.9 292.0
139.5 286.0 452.5
218.7 459.6 560.1
43.1
93.9
156.3
76.9
165.8 271.6
130.5 269.7 429.3
207.7 439.0 537.4
SIZE
1-1/2"
2"
2-1/2"
3"
4"
MAX. VEL
25 fps
27 fps
29 fps
31 fps
35 fps
4" (DN100) Body
% Build
10%
20%
30%
21950
44530
54920
21440
44140
64180
10050
20460
32420
16910
34810
55600
26130
54980
88620
42220
86440
136980
66230 139980 171860
20970
43180
62770
10050
20460
32420
16910
34810
55600
26130
54980
88620
42220
86440
136980
66230 139980 171860
9830
20020
31710
16910
34810
55600
26130
54980
88620
42220
86440
136980
66230 139980 171860
8150
16590
26290
16540
34050
54390
26110
54950
88570
42220
86440
136980
66230 139980 171860
15050
31000
49510
25560
53780
86680
42120
86240
136660
66230 139980 171860
NOTE: Where SONIC is indicated within the above capacity tables, outlet velocity with Schedule 40 pipe has reached sonic velocity of 1118 fps. Additional flow
cannot be obtained, and pipeline velocity is in excess of customary pipe velocity design limits. Flow will be approximately the last indicated value in the
column above SONIC.
8311-TB
11
TABLE 17
MODEL 8311 - LP VARIATION
STEAM CAPACITY - LBS/HR
S.G. = Actual T = Saturated FL = 0.88
All Sizes - Metal Diaphragm
Outlet
Pressure
(psig)
ATM
2.5
7.5
10
1-1/2" (DN40) Body
% Build
2" (DN50) Body
% Build
2-1/2" (DN65) Body
% Build
3" (DN80) Body
% Build
4" (DN100) Body
% Build
Set Point
Pressure
(psig)
10%
20%
30%
10%
20%
30%
10%
20%
30%
10%
20%
30%
10%
20%
30%
231
411
612
278
536
814
327
623
1020
378
710
1173
517
982
1627
10
112
216
386
127
259
463
151
290
510
178
336
618
243
463
838
15
201
393
598
230
479
766
263
551
862
326
632
1005
388
857
1364
20
343
647
905
399
793
1231
455
928
1434
534
1068
1631
737
1484
2288
25
528
958
HI VEL
639
1219
HI VEL
756
1434
2346
860
1629
2763
1173
1955
3747
30
805
HI VEL
HI VEL
975
1853
HI VEL
1145
2156
HI VEL
1322
2474
3456
1809
3389
4800
177
314
468
212
410
622
249
476
780
289
543
896
395
750
1243
10
104
201
358
118
240
430
140
269
473
165
312
573
226
430
777
15
195
381
581
223
465
744
256
534
837
316
613
976
376
832
1325
20
339
640
895
395
784
1218
450
918
1418
528
1057
1613
729
1468
2264
25
518
941
HI VEL
627
1197
1927
743
1408
2304
845
1600
2714
1152
1920
3681
30
787
1314
HI VEL
953
1813
HI VEL
1119
2109
2961
1293
2419
3380
1769
3315
4694
10
90
175
312
103
209
374
122
234
411
143
271
499
196
374
676
15
185
361
551
211
441
705
242
507
793
300
581
925
357
788
1255
20
331
624
874
385
765
1189
440
896
1384
516
1031
1574
711
1433
2209
25
513
931
1375
621
1185
1907
735
1394
2281
836
1584
2686
1140
1901
3643
30
782
1305
HI VEL
947
1800
2338
1112
2094
2940
1284
2402
3356
1757
3292
4661
10
68
131
234
77
157
281
91
176
309
108
204
375
147
281
508
15
169
330
504
193
403
645
222
463
725
274
532
846
326
721
1148
20
318
599
839
370
735
1141
422
860
1329
495
990
1511
683
1376
2121
25
503
912
1347
608
1161
1868
720
1366
2235
819
1552
2632
1117
1862
3569
30
774
1293
1669
938
1783
2315
1101
2074
2912
1271
2379
3324
1740
3260
4617
15
146
284
433
166
347
554
191
399
624
236
457
728
281
620
988
20
298
562
787
347
689
1071
396
807
1247
464
929
1418
640
1291
1990
25
487
883
1304
589
1123
1808
697
1322
2163
793
1502
2547
1081
1802
3454
30
761
1270
1640
921
1752
2275
1082
2038
2861
1249
2338
3266
1710
3203
4536
NOTE: Where HI VEL is indicated, the flow has reached or exceeded a velocity of Mach 0.35, an accepted limit for expanded steam on the downstream side.
Use of higher velocities normally generate excessive noise levels.
12
8311-TB
NOTES
8311-TB
13
Figure 2: Model 8311LP/HP Dimensional
See Table 18a/b
14
8311-TB
TABLE 18a
DIMENSIONS AND WEIGHTS ENGLISH UNITS
Dimensions - Inches
Size
Inches
End
Connection
14.00 11.25
4.75
6.89
11.12
20.50
20.38
14.00 11.25
6.38
8.44
12.69
21.50
22.00
14.00 11.25
6.38
8.44
12.69
21.50
22.00
14.00 11.25
7.69
9.74
14.00
22.75
23.50
14.00 11.25
7.69
9.74
14.00
22.75
23.50
LP
1-1/2"
2"
2-1/2"
3"
4"
NPT
125/150#Flgd.
250/300# Flgd.
NPT
125/150# Flgd.
250/300# Flgd.
125/150# Flgd.
250/300# Flgd.
125/150# Flgd.
250/300 # Flgd.
125/150# Flgd.
250/300# Flgd.
3.69
4.06
4.31
4.25
4.62
4.88
5.06
5.38
5.50
5.88
6.56
6.88
8.00
8.75
9.25
9.26
10.00
10.50
10.88
11.50
11.75
12.50
13.88
14.50
HP
Approximate
Ship Weight
lbs.
LP
HP
121
100
127
106
135
114
161
140
173
152
177
156
201
180
206
185
226
205
234
213
251
230
269
248
TABLE 18b
DIMENSIONS AND WEIGHTS METRIC UNITS
Dimensions (mm)
Size
(DN)
(40)
(50)
(65)
(80)
(100)
8311-TB
End
Connection
NPT
125/150# Flgd.
250/300# Flgd.
NPT
125/150# Flgd.
250/300# Flgd.
125/150# Flgd.
250/300# Flgd.
125/150# Flgd.
250/300 # Flgd.
125/150# Flgd.
250/300# Flgd.
A
94
103
110
108
117
124
129
137
140
149
167
175
B
203
222
235
235
254
267
276
292
298
318
352
368
286
121
175
283
521
518
356
286
162
214
322
546
559
356
286
162
214
322
546
559
356
286
195
247
356
578
597
356
286
195
247
356
578
597
LP
HP
356
Approximate
Ship Weight
(Kg.)
LP
HP
54.88
45.35
57.60
48.07
61.23
51.70
73.02
63.49
78.46
58.94
80.27
70.75
91.16
81.63
93.42
83.90
102.50 92.97
106.12 96.60
113.83 104.31
122.00 112.47
15
MODEL 8311 PRODUCT CODE
Table
1
Table
4
Table
3
Table
2
Table
5
Description
CODE
MODEL 8311HP Back
Pressure Relief Regulator
MODEL 8311LP Back
Pressure Relief Regulator
S1
S5
S5
S40
40
Table
8
Table
8
Table
8
In
NPT
(DN)
(40)
1-1/2"
Flanged
YES
YES
(50)
YES
YES
(65)
NO
YES
3"
(80)
NO
YES
4"
(100)
NO
YES
European
Countries *
Sound Engineering
Practice (SEP)
CE Marked Hazard
Cat I or II
TABLE 6 - END CONNECTION
Description
CODE
NPT-SCREWED
FLANGED - 125 LB (CI Body)
FLANGED - 150 LB (CS Body)
FLANGED - 250 LB (CI Body)
FLANGED - 300 LB (CS Body)
CODE
N/A
CS/CS
* Ductile Iron Sp.Ch. for 8311HP
Cast Iron Sp.Ch. for 8311LP
TABLE 5 - Product Classification
Under European
"Pressure Equipment Directive"
Anywhere except
Europe
CODE
CI / * Iron
2"
HAZARD
CATEGORY
Body/Sp. Ch.
CODE
2-1/2"
PRODUCT
DESTINATION
Table
8
Table
8
TABLE 3 - BODY & SP.
CHAMBER MATERIALS
Available End Connections
Stainless Steel Trim
S1
Table
8
Size
TABLE 4 - TRIM
DESIGNATION NO.
CODE
Table
7
Table
6
TABLE 2 - SIZE
TABLE 1 - VALVE TYPE
Desig.
09/06/11
S
E
* For products to be placed in service in Europe - Ref to
Directive 97/23/EC.
Forward Completed "EU" Application Recorder prior to
quotation. (Without Recorder- Processing of Purchase
Order will be delayed). Contact Cashco for Assistance.
TABLE 7 - RANGE SPRING
TABLE 8 - OPTIONS
Range
Product
8311HP
8311LP
Description
Option
CODE
No Option
Option
CODE
(.69-2.8)
Closing Cap
-1
30-100
(2.1-6.9)
Stellited Seat Surfaces
-15
75-145
(5.2-10.0)
-25
130-200 *
(9.0-13.8)
-80
1/4" NPT (DN8) Spring Chamber Vent Tap
CI or CS Spring Chamber
1-4
(.07-.28)
Plastic Rain proof Bug Vent (includes opt-25)
-25P
3-10
(.21-.69)
SST Rain proof Bug Vent (includes opt-25)
-25S
Special Cleaning: Per Cashco Spec #S-1542.
-56
High Pressure Sp. Chamber Const.
For Model 8311HP Only
-80
Epoxy Painted Per Cashco Spec #S-1547
-95
Epoxy Painted Per Cashco Spec #S-1687 Offshore
-95OS
psig
(Barg)
10-40
8-30
* Utilize Opt-80. Must specify in Table 8.
Comp diaphragm only.
(.55-2.1)
For Special Construction Other Than Above
Contact Cashco for Special Product Code
1. NUMERIC digits assigned first in ascending order.
2. ALPHA designations are assigned second in alphabetical order.
3. Left justify.
4. Add 0 to all unused squares.
5. If insufficient quantity of squares, consult factory for proper code.
Cashco, Inc.
P.O. Box 6
Ellsworth, KS 67439-0006
PH (785) 472-4461
Fax (785) 472-3539
www.cashco.com
E-mail:
[email protected][email protected]Printed in USA Model 8311-TB