CX-One: FA Integrated Tool Package
CX-One: FA Integrated Tool Package
CX-One
CXONE-AL C-V3/-AL
Ver.3.
D-V3
CXONE-LTO1C-V4
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL
DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE
PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE,
OR STRICT LIABILITY.
The application examples provided in this catalog are for reference only. Check functions and
In no event shall the responsibility of OMRON for any act exceed the individual price of the safety of the equipment before use.
product on which liability is asserted. Never use the products for any application requiring special safety requirements, such as nuclear
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER
CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE
energy control systems, railroad systems, aviation systems, medical equipment, amusement
machines, vehicles, safety equipment, or other application involving serious risk to life or property,
CX-One Lite
PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR
without ensuring that the system as a whole has been designed to address the risks, and that the
OMRON products are properly rated and installed for the intended use within the overall
Upgrade
REPAIR. equipment or system.
Position Control
The CX-One is a comprehensive software package that integrates PLC Programming Software with Support Software for setting up Networks, Programmable
Terminals, Servo Systems, Inverters, and Temperature Controllers.
Network
The PLC Programming Software Covers Everything from Support for SYSMAC CJ2 CPU Units without EtherNet/IP
Sequence Control to Position Control
The integration of Position Control Software into the PLC Programming Software greatly reduces the work required to set parameters, write programs, transfer
Batch Backup
data, and debug operation for Position Control Units. The parameter data is stored with the data for the PLC Programming Software to enable managing them
Upgrade
together.
Integrated Support Software Package
CJ2-CPU Position Control Units for Compact PLCs
CX-Programmer Ladder program (high-speed type)
CX-One Lite
We’ve upgraded the CX-One Lite Software Package
Easy Programming
which is designed specifically for low end systems.
CX-One Networks
Programming/Simulation Network Settings
Debugging
EtherNet/IP Ethernet
Programmable Terminal Network Configurator CX-Integrator
Screen Creation
Component Tools
CX-Programmer Motion Control PLC-based Process Control
CX-Simulator
NS SYSMAC CJ1
CX-Designer
SYSMAC CJ2 SYSMAC CJ2 Loop Controller
FA Communications Software
CX-Protocol
Serial
Network between PLCs CX-Motion
Creation of
Generic External CX-Position CX-Process
Devices Protocol
CX-Programmer Parameter Settings Origin Search Settings Macros
Setting up synchronous operation between SYSMAC CJ2 CPU Units and high-speed type Position Control Units is easily achieved on a visual interface.
Temperature Controllers
Ordering Information
Remote I/O Terminals Smart Slice
CJ2 Position Control Units Remote I/O Terminals
CX-Thermo
(high-speed type)
Network Settings Temperature
Controller Settings
MECHATROLINK- CX-Motion-NCF
CX-Motion-MCH
Synch
ronou
s Unit
s
CX-One Lite
Inverter Servomotor
CX-Drive
Servo/Inverter Settings
Windows is a registered trademark of the Microsoft Corporation. DeviceNet, DeviceNet Safety, CompoNet, and EtherNet/IP are trademarks or registered trademarks of the ODVA
Servomotor / Driver (Open DeviceNet Vendor Association). MECHATROLINK is a registered trademark of the MECHATROLINK Members Association. Other names of systems or products that appear in this
document are trademarks or registered trademarks of the respective company.
2 3
Position Control CX-Programmer
CX-One Ver.3.
NEW NEW
Position Control Software Integrated into the CX-Programmer Versatile Parameter Setting and Monitoring for Position Control
Position Control
Easily Achieve Position Control with Wading Through User Manuals Complete Support for Synchronous Operation between Units
Applicable Units : CJ1W-NC 214/234/414/434 Applicable Models : CJ2
Applicable Units : CJ1W-NC 214/234/414/434
Set Parameters for Position Control Units Together with Other PLC Settings Using Easy Setup of Synchronous Units
Network
the PLC Programming Software Just register to Synchronous Units to complete basic settings for memory allocations. If required, you can also easily customize the allocation
Parameters for the high-speed-type Position Control Units can be easily set from the CX-Programmer. The parameters are saved in parameters for the Synchronous Data Area.
the CX-Programmer project file so you can manage them and transfer them together with the programs and other data.
Batch Backup
Complete basic
allocation settings
merely by registering
the Synchronous
Units.
CX-Programme
Easy Programming
Save project file You can also
customize the
allocation parameters
for the Synchronous
Data Area.
Debugging
Visually Monitor Status of Synchronous Operation between Units
Use Automatic I/O Comment Generation to Reduce Programming Work You can display status lists for Synchronous Operation between Units operation to easily check Units with error.
I/O comments for parameters for high-speed-type Position Control Units can be easily generate, eliminating the need to refer to the user manual
Component Tools
for the memory map of the Position Control Unit. This enables programming with I/O comments.
FA Communications Software
Copy
&
Paste
Visual indications are
provided for errors.
Ordering Information
You can easily import data created with the CAM editor into the PLC memory component.
You can compare and reuse the parameter data set for each axis. Note: The WS02-MOPC2 CAM Data Creation Software (sold separately) is required to create CAM data.
Place windows
side-by-side
CX-One Lite
for more efficient
operation.
Import CAM Data
Copy
&
Paste
4 5
Position Control CX-Programmer
CX-One Ver.3.
NEW NEW
Position Control Software Integrated into the CX-Programmer Versatile Parameter Setting and Monitoring for Position Control
Position Control
Easily Achieve Position Control with Wading Through User Manuals Complete Support for Synchronous Operation between Units
Applicable Units : CJ1W-NC 214/234/414/434 Applicable Models : CJ2
Applicable Units : CJ1W-NC 214/234/414/434
Set Parameters for Position Control Units Together with Other PLC Settings Using Easy Setup of Synchronous Units
Network
the PLC Programming Software Just register to Synchronous Units to complete basic settings for memory allocations. If required, you can also easily customize the allocation
Parameters for the high-speed-type Position Control Units can be easily set from the CX-Programmer. The parameters are saved in parameters for the Synchronous Data Area.
the CX-Programmer project file so you can manage them and transfer them together with the programs and other data.
Batch Backup
Complete basic
allocation settings
merely by registering
the Synchronous
Units.
CX-Programme
Easy Programming
Save project file You can also
customize the
allocation parameters
for the Synchronous
Data Area.
Debugging
Visually Monitor Status of Synchronous Operation between Units
Use Automatic I/O Comment Generation to Reduce Programming Work You can display status lists for Synchronous Operation between Units operation to easily check Units with error.
I/O comments for parameters for high-speed-type Position Control Units can be easily generate, eliminating the need to refer to the user manual
Component Tools
for the memory map of the Position Control Unit. This enables programming with I/O comments.
FA Communications Software
Copy
&
Paste
Visual indications are
provided for errors.
Ordering Information
You can easily import data created with the CAM editor into the PLC memory component.
You can compare and reuse the parameter data set for each axis. Note: The WS02-MOPC2 CAM Data Creation Software (sold separately) is required to create CAM data.
Place windows
side-by-side
CX-One Lite
for more efficient
operation.
Import CAM Data
Copy
&
Paste
4 5
Network CX-Programmer CX-Integrator CX-One Ver.3.
Network Configurator
NEW NEW
USB and EtherNet/IP Ports are Standard Features for SYSMAC CJ2 CPU Units Integration of Network Construction and Parameter Settings
Position Control
Easier and Safer Connection to PLCs Now Supports EtherNet/ IP and CompoNet
CX-Programmer EtherNet/IP and CompoNet are now supported in addition to previously supported Ethernet, Controller Link, and DeviceNet networks.
Applicable Models : CJ2 High-speed and high-capacity data links are possible with EtherNet/IP, and synchronization cab be specified for each application without depending
Network
A standard USB cable can be easily connected to the USB port on the front of the CPU Unit.
Batch Backup
Standard USB cable
Standard-feature
USB port
CX-One
(Example:CX-Programmer)
Easy Programming
Easy Connection with EtherNet /IP
Easy connection by specifying the computer LAN ( Ethernet) port and IP address only. Remote I/O Terminals Temperature Controllers Remote I/O Terminals Smarts Slice
Debugging
EtherNet/IP
EtherNet/IP
Datalink Tool
Component Tools
HUB The addresses can be set for EtherNet/IP
CX-One
( Example:CX-Programmer) data links using data link tables.
192.168.250.13 192.168.250.14 192.168.250.15 Network Configurator
FA Communications Software
Prevent Connection Errors by Verifying PLC Names
The CJ2 CPU Unit can record a PLC name. Errors in transfers can be prevented ahead of time because
the PLC name can be compared with what is in the project file when connecting online.
HUB
Ordering Information
PLC name PLC name PLC name
Equipment_A Equipment_B Equipment_C Network Configurator CX-Integrator
CX-One Lite
Select a PLC from the list to connect to it.
the EtherNet/IP Connection List
Even if the IP address is unknown, you can browse a
list of PLCs connected to the EtherNet/IP and select
one to connect to it. With this, remote debugging
and maintenance can be conducted smoothly on site.
6 7
Network CX-Programmer CX-Integrator CX-One Ver.3.
Network Configurator
NEW NEW
USB and EtherNet/IP Ports are Standard Features for SYSMAC CJ2 CPU Units Integration of Network Construction and Parameter Settings
Position Control
Easier and Safer Connection to PLCs Now Supports EtherNet/ IP and CompoNet
CX-Programmer EtherNet/IP and CompoNet are now supported in addition to previously supported Ethernet, Controller Link, and DeviceNet networks.
Applicable Models : CJ2 High-speed and high-capacity data links are possible with EtherNet/IP, and synchronization cab be specified for each application without depending
Network
A standard USB cable can be easily connected to the USB port on the front of the CPU Unit.
Batch Backup
Standard USB cable
Standard-feature
USB port
CX-One
(Example:CX-Programmer)
Easy Programming
Easy Connection with EtherNet /IP
Easy connection by specifying the computer LAN ( Ethernet) port and IP address only. Remote I/O Terminals Temperature Controllers Remote I/O Terminals Smarts Slice
Debugging
EtherNet/IP
EtherNet/IP
Datalink Tool
Component Tools
HUB The addresses can be set for EtherNet/IP
CX-One
( Example:CX-Programmer) data links using data link tables.
192.168.250.13 192.168.250.14 192.168.250.15 Network Configurator
FA Communications Software
Prevent Connection Errors by Verifying PLC Names
The CJ2 CPU Unit can record a PLC name. Errors in transfers can be prevented ahead of time because
the PLC name can be compared with what is in the project file when connecting online.
HUB
Ordering Information
PLC name PLC name PLC name
Equipment_A Equipment_B Equipment_C Network Configurator CX-Integrator
CX-One Lite
Select a PLC from the list to connect to it.
the EtherNet/IP Connection List
Even if the IP address is unknown, you can browse a
list of PLCs connected to the EtherNet/IP and select
one to connect to it. With this, remote debugging
and maintenance can be conducted smoothly on site.
6 7
Batch Backup Easy Programming CX-One Ver.3.
CX-Programmer CX-Programmer
NEW
Data can be easily managed for the entire PLC system and down time in an emergency can be minimized Comprehensive Programming Environment with
Position Control
Batch Backup/Restore with a Computer Single-key Operation and Flexible Multilingual Support
A computer can be used to backup, compare, or restore data for all or specific PLC Units when connected online. Backup information is automatically In addition to practical functions such as single-key operation that improves the programming efficiency, processing is
tagged with a date stamp. It is thus possible to return to the state before an error occurred. It is also easy to identify the file for restoring data when an error conducted in the optimal language. Flexible multilingual support and the Smart Libraries enable a comprehensive
occurs. programming environment.
Network
Improved Programming Efficiency with Single-key Operation
PLC Backup Tool
The CX-Programmer features the “Single-key Concept” to increase operability. Apart from inputs to ladder diagrams, history
SYSMAC CS/CJ-series PLC
searches, and model jumps, single-key operation can be used for simulation debugging as well.
(CPU Unit + Configuration Units)
Batch Backup
Backup Destination Excellent Operability Makes Programming and Debugging Easy
Folder
Single-key Inputs
Easy Programming
The allocation of shortcut keys can be checked in the guidance for
Restore Comparison ladder input key operations. Key inputs, such as the C Key for NO
input conditions, the O Key for OUTPUT instruction, and the I Key
for special instructions are convenient when programming.
Just press the C Key and enter the bit number and comment to complete
Backup
the input condition. Special instruction can be input as shown in the following figure.
Debugging
Applications Backup Data
Backup of all data transferred to the PLC CPU Unit programs, data memory, and PLC Setup
Lines can be easily connected
Batch transfer of all data to a PLC with the same Settings for CPU Bus Units and Special I/O Ctrl
using key operations.
configuration (using the restore function) Units in the PLC
Transfer of relevant data to a new Unit installed
Component Tools
after a Unit has failed Single-key Searches and Jumps
Search functions, such as Find Back (searching for input conditions or outputs with the same address) and Find Address can be executed with a single key.
Single-key Simulation
Simulation and debugging of a PLC program can also be executed
FA Communications Software
The PLC model that is connected online will be displayed with a single key. Applications using both a PLC and Programmable
Terminal can be debugged using a computer without the actual
devices using PLC-PT Integrated Simulation. Icons for the simulation function can be accessed directly
Ordering Information
Ladder diagram:
User Program Controls the equipment Smart Libraries (Smart FB Library, SAP)
and external devices.
Ladder diagrams,
FB Function Block (FB): communications programs,
Task Can be used and and control screens can be
a : = a + 1;
reused as modules. created simply by selecting
RESULTS=0.0; Structured Text (ST): and pasting program modules
Task IF M=TRUE THEN
CX-One Lite
Simplifies math calculations from the extensive libraries.
RESULTS=SIN (date):
and character string Using FB and SAP modules Smart FB Library
ENDIF;
processing. to build the programs, it is
Task Sequential Function
possible to create programs
Charts (SFC): that are easier to understand.
Controls the steps
: Units that can be backed up Task in processing.
All Units in the PLC will be displayed.
: Units that have backup restrictions
Each Unit model and version A programming language suitable for
: Units that do not need to be backed up, or are not the process can be used Smart Active Parts
will be displayed. supported by this backup tool
8 9
Batch Backup Easy Programming CX-One Ver.3.
CX-Programmer CX-Programmer
NEW
Data can be easily managed for the entire PLC system and down time in an emergency can be minimized Comprehensive Programming Environment with
Position Control
Batch Backup/Restore with a Computer Single-key Operation and Flexible Multilingual Support
A computer can be used to backup, compare, or restore data for all or specific PLC Units when connected online. Backup information is automatically In addition to practical functions such as single-key operation that improves the programming efficiency, processing is
tagged with a date stamp. It is thus possible to return to the state before an error occurred. It is also easy to identify the file for restoring data when an error conducted in the optimal language. Flexible multilingual support and the Smart Libraries enable a comprehensive
occurs. programming environment.
Network
Improved Programming Efficiency with Single-key Operation
PLC Backup Tool
The CX-Programmer features the “Single-key Concept” to increase operability. Apart from inputs to ladder diagrams, history
SYSMAC CS/CJ-series PLC
searches, and model jumps, single-key operation can be used for simulation debugging as well.
(CPU Unit + Configuration Units)
Batch Backup
Backup Destination Excellent Operability Makes Programming and Debugging Easy
Folder
Single-key Inputs
Easy Programming
The allocation of shortcut keys can be checked in the guidance for
Restore Comparison ladder input key operations. Key inputs, such as the C Key for NO
input conditions, the O Key for OUTPUT instruction, and the I Key
for special instructions are convenient when programming.
Just press the C Key and enter the bit number and comment to complete
Backup
the input condition. Special instruction can be input as shown in the following figure.
Debugging
Applications Backup Data
Backup of all data transferred to the PLC CPU Unit programs, data memory, and PLC Setup
Lines can be easily connected
Batch transfer of all data to a PLC with the same Settings for CPU Bus Units and Special I/O Ctrl
using key operations.
configuration (using the restore function) Units in the PLC
Transfer of relevant data to a new Unit installed
Component Tools
after a Unit has failed Single-key Searches and Jumps
Search functions, such as Find Back (searching for input conditions or outputs with the same address) and Find Address can be executed with a single key.
Single-key Simulation
Simulation and debugging of a PLC program can also be executed
FA Communications Software
The PLC model that is connected online will be displayed with a single key. Applications using both a PLC and Programmable
Terminal can be debugged using a computer without the actual
devices using PLC-PT Integrated Simulation. Icons for the simulation function can be accessed directly
Ordering Information
Ladder diagram:
User Program Controls the equipment Smart Libraries (Smart FB Library, SAP)
and external devices.
Ladder diagrams,
FB Function Block (FB): communications programs,
Task Can be used and and control screens can be
a : = a + 1;
reused as modules. created simply by selecting
RESULTS=0.0; Structured Text (ST): and pasting program modules
Task IF M=TRUE THEN
CX-One Lite
Simplifies math calculations from the extensive libraries.
RESULTS=SIN (date):
and character string Using FB and SAP modules Smart FB Library
ENDIF;
processing. to build the programs, it is
Task Sequential Function
possible to create programs
Charts (SFC): that are easier to understand.
Controls the steps
: Units that can be backed up Task in processing.
All Units in the PLC will be displayed.
: Units that have backup restrictions
Each Unit model and version A programming language suitable for
: Units that do not need to be backed up, or are not the process can be used Smart Active Parts
will be displayed. supported by this backup tool
8 9
Easy Programming CX-One Ver.3.
CX-Programmer
NEW
Diversity of Programs Is Top Class in the Industry Usability Has Improved Also for Programming Using Addresses
Position Control
High Program Readability DM/EM Bits Can Be Addressed Applicable Models : CJ2
OMRON has refined the programming environment so that programs can be designed and written efficiently with minimal errors, high readability, and adaptability Bits could not be addresses in the DM and EM Areas with the previous SYSMAC CPU Units, but now it is possible with the CJ2. Programs with high readability can now be created.
to changes in specifications.
Network
Programming with Symbols Bit
D100
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
D100.05
Data Specification Is Easy To Understand with Array Variables (Array Symbols) Ladder diagram
Batch Backup
0.00 W 0.00 D100.05
Programs are easy to understand because data string sequences can be described with subscripts. This feature can also be used for network
symbols. Therefore exchanges of multiple data with external devices can be easily written.
(Available languages: Ladder diagrams, ST, and SFC)
Easy Programming
0 WORD data Ladder diagram : Copy ABC [3] to D200 Address Offsets Can Be Specified Applicable Models : CJ2
1 WORD data Offsets from a specific starting bit address or word address can be specified in programming. Addresses can be dynamically specified with the contents of a word by
5.00
specifying the specific address in I/O memory as the offset. This way it is possible to create programs in a similar way to using index registers.
2 WORD data MOV
3 WORD data When you want to access ABC:[3]
WORD data this data, use ABC [3]
4
D200 Example 1 : D100 [5] : Take D100 as the first address and add an offset of 5 words to specify D105
Debugging
5 WORD data
Ladder diagram Element
6 WORD data D100 [5] number
Structured Text ( ST ): Substitute ABC[0] to ABC[3] 0.00 Starting word
7 WORD data Number of 0
MOV address D100
ABC[3] : = ABC[0] ; offset words 1
8 WORD data D100 [ 5 ]
Starting word address 2
Component Tools
9 WORD data Number of
D200 offset words 3
+5 4 Copy this
First element
in array variable value to
5 D200
Symbols Can Be Used As Subscripts for Array Variables Applicable Models : CJ2
FA Communications Software
Example 2 : 10.00[5]:10.00[5]: Take CIO 10.00 as the starting bit address and add an offset of 5 bits to specify CIO 10.05
Data can be dynamically specified by using physical addresses and symbols as the subscripts to arrays.
Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
10.00 [5] 10CH
Example : data[ i ]:Indirect specification of an element number using symbol i Number of
Number of offset bits +5
If symbol i is &5, it specifies the 5th element in the array offset bits
Starting bit address
Ordering Information
Element
First element 0 data [0] Ladder diagram number
Ladder diagram : Copy data [ i ] to D200 in array variable
D100 [W100] Starting word
1 data [1] 0.00 0
address D100
5.00 Value of data [2] Number of MOV 1
2
element i offset words 2
MOV (e.g., i=5) 3 data [3] D100[W100] Number of
Starting word address offset words 3
data [ i ] 4 data [4] D200
Copy this W100 4 Copy this
CX-One Lite
D200 5 data [5] value to (e.g., i=5)
value to
D200 5 D200
10 11
Easy Programming CX-One Ver.3.
CX-Programmer
NEW
Diversity of Programs Is Top Class in the Industry Usability Has Improved Also for Programming Using Addresses
Position Control
High Program Readability DM/EM Bits Can Be Addressed Applicable Models : CJ2
OMRON has refined the programming environment so that programs can be designed and written efficiently with minimal errors, high readability, and adaptability Bits could not be addresses in the DM and EM Areas with the previous SYSMAC CPU Units, but now it is possible with the CJ2. Programs with high readability can now be created.
to changes in specifications.
Network
Programming with Symbols Bit
D100
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
D100.05
Data Specification Is Easy To Understand with Array Variables (Array Symbols) Ladder diagram
Batch Backup
0.00 W 0.00 D100.05
Programs are easy to understand because data string sequences can be described with subscripts. This feature can also be used for network
symbols. Therefore exchanges of multiple data with external devices can be easily written.
(Available languages: Ladder diagrams, ST, and SFC)
Easy Programming
0 WORD data Ladder diagram : Copy ABC [3] to D200 Address Offsets Can Be Specified Applicable Models : CJ2
1 WORD data Offsets from a specific starting bit address or word address can be specified in programming. Addresses can be dynamically specified with the contents of a word by
5.00
specifying the specific address in I/O memory as the offset. This way it is possible to create programs in a similar way to using index registers.
2 WORD data MOV
3 WORD data When you want to access ABC:[3]
WORD data this data, use ABC [3]
4
D200 Example 1 : D100 [5] : Take D100 as the first address and add an offset of 5 words to specify D105
Debugging
5 WORD data
Ladder diagram Element
6 WORD data D100 [5] number
Structured Text ( ST ): Substitute ABC[0] to ABC[3] 0.00 Starting word
7 WORD data Number of 0
MOV address D100
ABC[3] : = ABC[0] ; offset words 1
8 WORD data D100 [ 5 ]
Starting word address 2
Component Tools
9 WORD data Number of
D200 offset words 3
+5 4 Copy this
First element
in array variable value to
5 D200
Symbols Can Be Used As Subscripts for Array Variables Applicable Models : CJ2
FA Communications Software
Example 2 : 10.00[5]:10.00[5]: Take CIO 10.00 as the starting bit address and add an offset of 5 bits to specify CIO 10.05
Data can be dynamically specified by using physical addresses and symbols as the subscripts to arrays.
Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
10.00 [5] 10CH
Example : data[ i ]:Indirect specification of an element number using symbol i Number of
Number of offset bits +5
If symbol i is &5, it specifies the 5th element in the array offset bits
Starting bit address
Ordering Information
Element
First element 0 data [0] Ladder diagram number
Ladder diagram : Copy data [ i ] to D200 in array variable
D100 [W100] Starting word
1 data [1] 0.00 0
address D100
5.00 Value of data [2] Number of MOV 1
2
element i offset words 2
MOV (e.g., i=5) 3 data [3] D100[W100] Number of
Starting word address offset words 3
data [ i ] 4 data [4] D200
Copy this W100 4 Copy this
CX-One Lite
D200 5 data [5] value to (e.g., i=5)
value to
D200 5 D200
10 11
Debugging CX-One Ver.3.
CX-Programmer CX-Integrator
Ver.up
Comprehensive Debugging for Networks Time Require for Debugging and Maintenance Has Been Reduced with
Position Control
Time Required for Onsite Startup and the Comprehensive Data Trace Function
Functionality and operability has been significantly upgraded compared to the previous data trace function. The new data trace function provides
comprehensive debugging, such as I/O comment display of sampled addresses, specification using symbols, checking the measurement time between
Debugging Has Been Significantly Reduced two selected points, and layering waveforms. Furthermore, data sampled from the CPU Unit’s trace memory can be saved to a file on the computer at
a specified frequency. This can be used as for long-term logging of data.
Network
With CX-One version 3.0, debugging is efficient with simultaneously monitoring and management of multiple networks and PLCs.
Data Trace Function Sampled values from a specific Continuous Data Trace Applicable Models : CJ2
word will be displayed.
Logging
Management of Multiple Networks
The operation of networks with configurations consisting of The CJ2 CPU Units can trace data for long periods of time.
Batch Backup
multiple networks including PLC networks such as Data can be saved in CSV files.
Third
EtherNet/IP and Controller Link, field networks such as Second
First
DeviceNet and CompoNet, and networks for Programmable
Terminals and Serial Devices, can be restored simultaneously
from the CX-One. Onsite start up and debugging can be
Easy Programming
conducted efficiently and without errors because PLCs
and devices can be selected from the window to transfer
programs and parameter data to the computer during Data is collected in the computer
at a specified interval
operation.
Debugging
High-speed sampling to the
PLC trace memory
CX-Integrator Sampled value from a
The traced waveforms can be displayed as layers. specific input bit will be SYSMAC CJ2
Ladder diagram Monitoring for displayed.
Multiple PLCs
Component Tools
Multiple PLCs can be monitored by displaying them in series on the screen. This way it is easy to debug data links between PLCs and monitor the
inputs and outputs of different PLCs.
Simulation Debugging
Programs can be debugged using a computer without the actual PLC. A wide range of languages, such as ladder diagram, sequential function
charts (SFC), structured text (ST), and programs within function blocks are supported. Furthermore, programs can be edited online, bits can be
PLC1 PLC2 PLC3
FA Communications Software
force-set/reset, breakpoints can be set, and a PLC error simulator can be used.
Node 1 Node 2 Node 3 Simulation of SFC, Ladder Diagrams, and Function Blocks
Error Simulation
Ordering Information
Group Monitoring of Multiple PLC Input/Outputs in the Watch Window
The desired I/O data can be selected for multiple PLCs, such as input bits, output bits, and word I/O data, and monitored simultaneously. There
are also functions such as the Binary Monitor and Forced Set/Reset functions that enables graphical monitoring the ON/OFF status of word data. Breakpoints
All of these monitoring functions are easy to use.
Breakpoints can be inserted
anywhere in the program,
such as for input bits,
CX-One Lite
output instructions, special i
nstructions, or function blocks.
Addresses that Breakpoints
you want to
monitor can be
registered for
each debugging
segment. No Size Restrictions for Online Editing of Function Blocks and Applicable Models : CJ2
12 13
Debugging CX-One Ver.3.
CX-Programmer CX-Integrator
Ver.up
Comprehensive Debugging for Networks Time Require for Debugging and Maintenance Has Been Reduced with
Position Control
Time Required for Onsite Startup and the Comprehensive Data Trace Function
Functionality and operability has been significantly upgraded compared to the previous data trace function. The new data trace function provides
comprehensive debugging, such as I/O comment display of sampled addresses, specification using symbols, checking the measurement time between
Debugging Has Been Significantly Reduced two selected points, and layering waveforms. Furthermore, data sampled from the CPU Unit’s trace memory can be saved to a file on the computer at
a specified frequency. This can be used as for long-term logging of data.
Network
With CX-One version 3.0, debugging is efficient with simultaneously monitoring and management of multiple networks and PLCs.
Data Trace Function Sampled values from a specific Continuous Data Trace Applicable Models : CJ2
word will be displayed.
Logging
Management of Multiple Networks
The operation of networks with configurations consisting of The CJ2 CPU Units can trace data for long periods of time.
Batch Backup
multiple networks including PLC networks such as Data can be saved in CSV files.
Third
EtherNet/IP and Controller Link, field networks such as Second
First
DeviceNet and CompoNet, and networks for Programmable
Terminals and Serial Devices, can be restored simultaneously
from the CX-One. Onsite start up and debugging can be
Easy Programming
conducted efficiently and without errors because PLCs
and devices can be selected from the window to transfer
programs and parameter data to the computer during Data is collected in the computer
at a specified interval
operation.
Debugging
High-speed sampling to the
PLC trace memory
CX-Integrator Sampled value from a
The traced waveforms can be displayed as layers. specific input bit will be SYSMAC CJ2
Ladder diagram Monitoring for displayed.
Multiple PLCs
Component Tools
Multiple PLCs can be monitored by displaying them in series on the screen. This way it is easy to debug data links between PLCs and monitor the
inputs and outputs of different PLCs.
Simulation Debugging
Programs can be debugged using a computer without the actual PLC. A wide range of languages, such as ladder diagram, sequential function
charts (SFC), structured text (ST), and programs within function blocks are supported. Furthermore, programs can be edited online, bits can be
PLC1 PLC2 PLC3
FA Communications Software
force-set/reset, breakpoints can be set, and a PLC error simulator can be used.
Node 1 Node 2 Node 3 Simulation of SFC, Ladder Diagrams, and Function Blocks
Error Simulation
Ordering Information
Group Monitoring of Multiple PLC Input/Outputs in the Watch Window
The desired I/O data can be selected for multiple PLCs, such as input bits, output bits, and word I/O data, and monitored simultaneously. There
are also functions such as the Binary Monitor and Forced Set/Reset functions that enables graphical monitoring the ON/OFF status of word data. Breakpoints
All of these monitoring functions are easy to use.
Breakpoints can be inserted
anywhere in the program,
such as for input bits,
CX-One Lite
output instructions, special i
nstructions, or function blocks.
Addresses that Breakpoints
you want to
monitor can be
registered for
each debugging
segment. No Size Restrictions for Online Editing of Function Blocks and Applicable Models : CJ2
12 13
Component Tools CX-One Ver.3.
(Screen Designing) CX-Designer
Products Are Highly Compatible and Easy to Use Because They Are from a Comprehensive PLC Manufacturer Integrated Simulation with the PLC Ladder Diagrams
Position Control
The CX-Designer Simplifies the Processes from Screen
Test functions for the CX-Designer and CX-Programmer are linked through the CX-Simulator on a computer. This enables screens and ladder diagrams to be
checked simultaneously, significantly improving the debugging efficiency. A new Integrated Simulation Button has been added to the CX-Programmer.
Furthermore, work efficiency has been significantly improved with the function that enables work windows to be pinned in front, and a flexible zoom function.
Design to Debugging for the NS-series Programmable Terminals Screens and Ladder Diagrams Can Be Simultaneously Checked on a Computer
Ladder Diagram Window Touch Panel Screen
Network
The time required for designing can be significantly reduced because of the compatibility with SYSMAC
Applicable Units :
CJ-series PLCs. The process of designing screens is easier with expanded functionality.
NS Series NSJ Series Linked
Single-key Simulation
Batch Backup
Within computer
Easy Programming
SAP Library of Temperature Screen Designing Tools
Controller Components CX-Designer Using Software Components, Error Checking and
Parameter Setting Can Be Done without a Computer
There are many software components in the Software Function SAP Library that
Drag
and can be easily incorporated into the NS-series Programmable Terminals. Simply
drop select and paste software components on the screen. Device errors can be
checked and parameters set without a computer.
Debugging
FROM Computer Software The Comprehensive Screen Designing Software Makes for Easy Creation of Multifunction Screens
Transfer A Multifunction Object is a collection of the functions of various objects. Multiple functions can be operated with a single press of a button without using
cumbersome macros. Setting Multifunction Objects is easy. For example, you can visually create a setting like “Change the screen when the device operation
Component Tools
start bit turns ON and the value is set” using the software.
Immediate creation of
Temperature Controller
Settings and Monitor Screens Operation of multiple functions can be Easy and visual software settings
achieved with a single hit of a button without
TO EASY Tools (Software Function SAP Library) using macros
Multiple functions
FA Communications Software
FROM Two or more functions are two or more buttuons can be achieved
with a single object
Consolidating
Screen
CJ2 E5AN
Bit ON Set Words Switching
Turn ON bit
PLC CPU Unit
Monitor Screen
NCF Unit
Ordering Information
There is a troubleshooter SAP library that covers all PLC Units. If there is a PLC error, the troubleshooter SAP library explains the cause and
how to implement countermeasures in a way that it is easy to understand.
CX-One Lite
In addition to the DeviceNet Units and Position
Control Units, the CX-Designer also includes Basic
I/O Unit, Analog I/O Units, Serial Communications
Units, High-speed Counter Units, Controller Link Unit,
and ID Sensor Units. Including the EtherNet Units
NV Series
and Motion Control Units is planned in future
development stages.
Position Control Unit Troubleshooter SAP Basic I/O Unit Troubleshooter SAP
NV3W-MG 0( ) NV3W-MR 0( ) NV3Q-MR 1 NV3Q-SW 1
14 15
Component Tools CX-One Ver.3.
(Screen Designing) CX-Designer
Products Are Highly Compatible and Easy to Use Because They Are from a Comprehensive PLC Manufacturer Integrated Simulation with the PLC Ladder Diagrams
Position Control
The CX-Designer Simplifies the Processes from Screen
Test functions for the CX-Designer and CX-Programmer are linked through the CX-Simulator on a computer. This enables screens and ladder diagrams to be
checked simultaneously, significantly improving the debugging efficiency. A new Integrated Simulation Button has been added to the CX-Programmer.
Furthermore, work efficiency has been significantly improved with the function that enables work windows to be pinned in front, and a flexible zoom function.
Design to Debugging for the NS-series Programmable Terminals Screens and Ladder Diagrams Can Be Simultaneously Checked on a Computer
Ladder Diagram Window Touch Panel Screen
Network
The time required for designing can be significantly reduced because of the compatibility with SYSMAC
Applicable Units :
CJ-series PLCs. The process of designing screens is easier with expanded functionality.
NS Series NSJ Series Linked
Single-key Simulation
Batch Backup
Within computer
Easy Programming
SAP Library of Temperature Screen Designing Tools
Controller Components CX-Designer Using Software Components, Error Checking and
Parameter Setting Can Be Done without a Computer
There are many software components in the Software Function SAP Library that
Drag
and can be easily incorporated into the NS-series Programmable Terminals. Simply
drop select and paste software components on the screen. Device errors can be
checked and parameters set without a computer.
Debugging
FROM Computer Software The Comprehensive Screen Designing Software Makes for Easy Creation of Multifunction Screens
Transfer A Multifunction Object is a collection of the functions of various objects. Multiple functions can be operated with a single press of a button without using
cumbersome macros. Setting Multifunction Objects is easy. For example, you can visually create a setting like “Change the screen when the device operation
Component Tools
start bit turns ON and the value is set” using the software.
Immediate creation of
Temperature Controller
Settings and Monitor Screens Operation of multiple functions can be Easy and visual software settings
achieved with a single hit of a button without
TO EASY Tools (Software Function SAP Library) using macros
Multiple functions
FA Communications Software
FROM Two or more functions are two or more buttuons can be achieved
with a single object
Consolidating
Screen
CJ2 E5AN
Bit ON Set Words Switching
Turn ON bit
PLC CPU Unit
Monitor Screen
NCF Unit
Ordering Information
There is a troubleshooter SAP library that covers all PLC Units. If there is a PLC error, the troubleshooter SAP library explains the cause and
how to implement countermeasures in a way that it is easy to understand.
CX-One Lite
In addition to the DeviceNet Units and Position
Control Units, the CX-Designer also includes Basic
I/O Unit, Analog I/O Units, Serial Communications
Units, High-speed Counter Units, Controller Link Unit,
and ID Sensor Units. Including the EtherNet Units
NV Series
and Motion Control Units is planned in future
development stages.
Position Control Unit Troubleshooter SAP Basic I/O Unit Troubleshooter SAP
NV3W-MG 0( ) NV3W-MR 0( ) NV3Q-MR 1 NV3Q-SW 1
14 15
Component Tools Component Tools CX-One Ver.3.
(Servomotor Control) CX-Motion-NCF CX-Motion-MCH
(Temperature Controllers) CX-Thermo CX-Process Tool
Easy High-level Servomotor Control From Parameter Settings to Temperature Data Management
Position Control
The CX-Motion Supports The CX-Thermo/CX-Process Software Supports
Motion Network Servo Systems High-level Temperature Control
Improve productivity of motion network servo systems using MECHATROLINK-II for design, startup, and maintenance.
Network
Setting Temperature Controller Parameters Is Easier CX-Thermo
Easy Management of Parameters While Still Connected to PLCs CX-Motion-NCF
Parameters can be easily set from a list
Batch Backup
Parameters that can be edited
Parameter Easy Parameter Settings
Settings can be modified while connected Property
Parameters can be set even for Temperature Controllers that
Position Control Unit axis settings and Servo Driver parameters Window
do not support communications.
Editing Parameters
Parameters for the Position Control Unit and Servo Drive can be edited easily. Parameters can be saved, and then copied, or reused and edited
Work
(Parameters can be exported in CSV or HTML format.)
Transferring and Comparing Parameters
space
Easy Programming
Parameters for the Position Control Units and the connected Servo Drive Displays Only What Is Used
can be transferred.
To avoid unintentional use of parameters, unused parameters
can be masked (i.e., hidden)
Wiring can be checked while connected
Monitoring The status and present values of data for the Position Control Unit
and the connected Servo Drive can be monitored. Data can be Applicable Units :
monitored for up to four axes simultaneously.
E5CN/E5CN-H/E5AN/E5AN-H/E5EN/
Operation can be checked while connected
Debugging
Output Parameter E5EN-H,EJ1,E5ZN,E5AR/E5AR-T/
Window List E5ER/E5ER-T The DeviceNet type is excluded
Trial Operation It is possible to lock the Servo, jog an axis, or reset an error. The error
code and ON/OFF status of each axis can be displayed. Present Applicable Units : CS1W/CJ1W-NCF71
values and busy status can also be monitored. NC271/NC471
Component Tools
Programming for the Process Controller Is Easier CX-Process
Even Easier to Start Up a System CX-Motion-MCH
Control Programs Can Be Constructed By Pasting Function Blocks
Programming Is Easy
FA Communications Software
Control Can Be Customized
Editing Parameters Control programs can be constructed by pasting function
Task and axis parameters can be edited easily. Debugging motion programs
blocks and connecting them. They can be used for simple PID
Insert a breakpoint where you want to control, program control, and cascade control.
Checking Program Edits and Syntax
The motion program can be created and edited. Syntax can be pause the program
checked and lines that require correction can be displayed with Easy Creation of an HMI
Content check
Ordering Information
Debugging Programs Is Easy Window CS1W-LCB01/LCB05/LCB05-GTC,
CS1W-LC001,CS1D-CPU6 P
Trial Operation
The servo lock, jog, step, origin search, origin reset, forced origin, error Data trace results
reset, absolute origin setting, and teaching functions can be used. Error
codes and the ON/OFF status of axis I/O can also be displayed. Because The graph can be
of this, device startup and adjustments can be made easily. zoomed in or out
CX-Thermo/CX-Process Support Software
CX-One Lite
Debugging Motion Programs The scale can be changed,
Motion programs can be executed using the software. It is easy to display position moved, and Adjusting Parameters While Controlling with a Reliable Control Algorithm (See note.)
debug and make corrections using breakpoints. data displayed or hidden
Monitoring Trends The execution of the autotuning (AT) function that calculates the PID constants and the fine
Displays the difference of PID parameters can be adjusted while tuning (FT) function that improves controllability exactly as required are made easy with an
Checking Operation Is Easy monitoring the present value (PV), setting point intuitive user interface. The interference overshooting adjustment function is supported to
between the curser position
Data Trace Function (SP), and manipulated variable (MV). Trend data adjust overshooting when interference occurs, and the gradient temperature control function
and the value
The values of each variable in the Motion Control Unit can be traced. can be saved in CSV format. achieves constant internal temperatures for multi-point temperature control with interference.
The results are displayed in a graph and can be used for checking operation or (CX-Thermo Trend Viewer, CX-Process Support Software
Applicable Units : CS1W/CJ1W-MCH71 Tuning Screen) Note: Supported functions depends on the product being used. Refer to product manuals for details.
making adjustments.
16 17
Component Tools Component Tools CX-One Ver.3.
(Servomotor Control) CX-Motion-NCF CX-Motion-MCH
(Temperature Controllers) CX-Thermo CX-Process Tool
Easy High-level Servomotor Control From Parameter Settings to Temperature Data Management
Position Control
The CX-Motion Supports The CX-Thermo/CX-Process Software Supports
Motion Network Servo Systems High-level Temperature Control
Improve productivity of motion network servo systems using MECHATROLINK-II for design, startup, and maintenance.
Network
Setting Temperature Controller Parameters Is Easier CX-Thermo
Easy Management of Parameters While Still Connected to PLCs CX-Motion-NCF
Parameters can be easily set from a list
Batch Backup
Parameters that can be edited
Parameter Easy Parameter Settings
Settings can be modified while connected Property
Parameters can be set even for Temperature Controllers that
Position Control Unit axis settings and Servo Driver parameters Window
do not support communications.
Editing Parameters
Parameters for the Position Control Unit and Servo Drive can be edited easily. Parameters can be saved, and then copied, or reused and edited
Work
(Parameters can be exported in CSV or HTML format.)
Transferring and Comparing Parameters
space
Easy Programming
Parameters for the Position Control Units and the connected Servo Drive Displays Only What Is Used
can be transferred.
To avoid unintentional use of parameters, unused parameters
can be masked (i.e., hidden)
Wiring can be checked while connected
Monitoring The status and present values of data for the Position Control Unit
and the connected Servo Drive can be monitored. Data can be Applicable Units :
monitored for up to four axes simultaneously.
E5CN/E5CN-H/E5AN/E5AN-H/E5EN/
Operation can be checked while connected
Debugging
Output Parameter E5EN-H,EJ1,E5ZN,E5AR/E5AR-T/
Window List E5ER/E5ER-T The DeviceNet type is excluded
Trial Operation It is possible to lock the Servo, jog an axis, or reset an error. The error
code and ON/OFF status of each axis can be displayed. Present Applicable Units : CS1W/CJ1W-NCF71
values and busy status can also be monitored. NC271/NC471
Component Tools
Programming for the Process Controller Is Easier CX-Process
Even Easier to Start Up a System CX-Motion-MCH
Control Programs Can Be Constructed By Pasting Function Blocks
Programming Is Easy
FA Communications Software
Control Can Be Customized
Editing Parameters Control programs can be constructed by pasting function
Task and axis parameters can be edited easily. Debugging motion programs
blocks and connecting them. They can be used for simple PID
Insert a breakpoint where you want to control, program control, and cascade control.
Checking Program Edits and Syntax
The motion program can be created and edited. Syntax can be pause the program
checked and lines that require correction can be displayed with Easy Creation of an HMI
Content check
Ordering Information
Debugging Programs Is Easy Window CS1W-LCB01/LCB05/LCB05-GTC,
CS1W-LC001,CS1D-CPU6 P
Trial Operation
The servo lock, jog, step, origin search, origin reset, forced origin, error Data trace results
reset, absolute origin setting, and teaching functions can be used. Error
codes and the ON/OFF status of axis I/O can also be displayed. Because The graph can be
of this, device startup and adjustments can be made easily. zoomed in or out
CX-Thermo/CX-Process Support Software
CX-One Lite
Debugging Motion Programs The scale can be changed,
Motion programs can be executed using the software. It is easy to display position moved, and Adjusting Parameters While Controlling with a Reliable Control Algorithm (See note.)
debug and make corrections using breakpoints. data displayed or hidden
Monitoring Trends The execution of the autotuning (AT) function that calculates the PID constants and the fine
Displays the difference of PID parameters can be adjusted while tuning (FT) function that improves controllability exactly as required are made easy with an
Checking Operation Is Easy monitoring the present value (PV), setting point intuitive user interface. The interference overshooting adjustment function is supported to
between the curser position
Data Trace Function (SP), and manipulated variable (MV). Trend data adjust overshooting when interference occurs, and the gradient temperature control function
and the value
The values of each variable in the Motion Control Unit can be traced. can be saved in CSV format. achieves constant internal temperatures for multi-point temperature control with interference.
The results are displayed in a graph and can be used for checking operation or (CX-Thermo Trend Viewer, CX-Process Support Software
Applicable Units : CS1W/CJ1W-MCH71 Tuning Screen) Note: Supported functions depends on the product being used. Refer to product manuals for details.
making adjustments.
16 17
FA Communications Software Online Web Services
Position Control
Simply paste to the form and
CX-Compolet
specify the tags (addresses).
Network
consider differences between networks.
Supports Microsoft Visual Studio .NET 2008. SYSMAC Gateway
y software components can be registered at once. The
For the CJ2 with EtherNet/IP functionality, I/O online registration website can be accessed from Japan,
memory in the PLC can be accessed by using tag North America, South America, Central America, Europe,
names rather than addresses.
Array variable access is possible.
Africa, Asia, China, Taiwan, and Korea. You can access
Press the button to read the
DM0 the Internet services from anywhere once you have
Batch Backup
1234 value (D0 in this example).
SYSMAC PLC registered.
Easy Programming
NEW
Applications
Communications Middleware to Connect a
Computer and SYSMAC PLCs
Automatic Update
SYSMAC Gateway
Direct Connection of the Industrial Ethernet: EtherNet/IP
SYSMAC Gateway With the automatic update function of CX-One, the latest
update information for your computer environment can be
Debugging
Direct Access to High-speed and
searched for and applied using the network environment.
High-capacity Networks
Your CX-One can be constantly updated to the latest state.
In addition to FINS communications, operation of It is also possible to update only the necessary tools.
SYSMAC Gateway has been verified on EtherNet/IP. Serial EtherNet/IP Controller Link
Absorbs differences in the physical layer between
Component Tools
RS-232C, USB, Ethernet, EtherNet/IP, and
Controller Link.
Just install the software on the computer to enable
data communications for controls and information.
FA Communications Software
Download Services
Ordering Information
and Writing with VB.NET SYSMAC Compolet.
(Previously called “SYSMAC Compolet.”) and VC#.NET Control Objects
CX-One Lite
driver on most networks. It is
the successor to FinsGateway
and has inherited all
RS-232C USB EtherNet/IP Ethernet Controller Link FinsGateway functionality.
SYSMAC PLC SYSMAC PLC SYSMAC PLC SYSMAC PLC SYSMAC PLC
18 19
FA Communications Software Online Web Services
Position Control
Simply paste to the form and
CX-Compolet
specify the tags (addresses).
Network
consider differences between networks.
Supports Microsoft Visual Studio .NET 2008. SYSMAC Gateway
y software components can be registered at once. The
For the CJ2 with EtherNet/IP functionality, I/O online registration website can be accessed from Japan,
memory in the PLC can be accessed by using tag North America, South America, Central America, Europe,
names rather than addresses.
Array variable access is possible.
Africa, Asia, China, Taiwan, and Korea. You can access
Press the button to read the
DM0 the Internet services from anywhere once you have
Batch Backup
1234 value (D0 in this example).
SYSMAC PLC registered.
Easy Programming
NEW
Applications
Communications Middleware to Connect a
Computer and SYSMAC PLCs
Automatic Update
SYSMAC Gateway
Direct Connection of the Industrial Ethernet: EtherNet/IP
SYSMAC Gateway With the automatic update function of CX-One, the latest
update information for your computer environment can be
Debugging
Direct Access to High-speed and
searched for and applied using the network environment.
High-capacity Networks
Your CX-One can be constantly updated to the latest state.
In addition to FINS communications, operation of It is also possible to update only the necessary tools.
SYSMAC Gateway has been verified on EtherNet/IP. Serial EtherNet/IP Controller Link
Absorbs differences in the physical layer between
Component Tools
RS-232C, USB, Ethernet, EtherNet/IP, and
Controller Link.
Just install the software on the computer to enable
data communications for controls and information.
FA Communications Software
Download Services
Ordering Information
and Writing with VB.NET SYSMAC Compolet.
(Previously called “SYSMAC Compolet.”) and VC#.NET Control Objects
CX-One Lite
driver on most networks. It is
the successor to FinsGateway
and has inherited all
RS-232C USB EtherNet/IP Ethernet Controller Link FinsGateway functionality.
SYSMAC PLC SYSMAC PLC SYSMAC PLC SYSMAC PLC SYSMAC PLC
18 19
Ordering Information
Position Control
Number of licenses Media Support Software in CX-One Outline
CD CXONE-AL01C-V3
1 licenses −
CX-Programmer Application software to create and debug programs for SYSMAC CS/CJ/CP/NSJseries, C-series, and CVM1/C-series CPU Units.
DVD CXONE-AL01D-V3 Ver.8.2
Data can be created and monitored for high-speed-type Position Control Units.
The CX-One is a
CD CXONE-AL03C-V3
comprehensive software −
3 licenses
package that integrates
Network
DVD CXONE-AL03D-V3 Application software to build and set up FA networks, such as Controller Link, DeviceNet, CompoNet, CompoWay, and Ethernet networks.
Support Software for OMRON CX-Integrator Ver.2.3
The Routing Table Component and Data Link Component can be started from here. DeviceNet Configuration functionality is also included.
FA Integrated Tool
PLCs and components. CD CXONE-AL10C-V3
Package CX-One 10 licenses −
Ver. 3.2 CX-One runs on DVD CXONE-AL10D-V3 Utility software that helps you to debug PLCs. It helps you to monitor the I/O status and to monitor/change present values within
Switch Box Utility Ver.1.6
the following OS. the PLC you specify.
CD CXONE-AL30C-V3
Batch Backup
Windows 2000
30 licenses −
(Service Pack 3 or higher), DVD CXONE-AL30D-V3
XP, or Vista Application software to create protocols (communications sequences) between SYSMAC CS/CJ/CP/NSJ-series or
CX-Protocol Ver.1.8
CD CXONE-AL50D-V3 C200HX/HG/HE Serial Communications Boards/Units and general-purpose external devices.
50 licenses −
DVD CXONE-AL50D-V3
Easy Programming
Application software to simulate SYSMAC CS/CJ/CP/NSJ-series CPU Unit operation on the computer to debug PLC programs
Note 1. Site licenses are available for users who will run CX-One on multiple computers. Ask your OMRON sales representative for details. CX-Simulator Ver.1.9
without a CPU Unit.
2. When purchasing the DVD format, verify the computer model and DVD drive specifications before purchasing.
CX-Position Ver.2.5 Application software to create and monitor data for SYSMAC CS/CJ-series Position Control Units.
System Requirements
Application software to monitor and set parameters for SYSMAC CS/CJ-series Position Control Units and Servo Drivers
CX-Motion-NCF Ver.1.8
Debugging
that support MECHATROLINK-II communications.
Item Requirement
Component Tools
by Microsoft. (1 GHz or faster recommended) Application software to create data for SYSMAC CS/CJ-series, C200HX/HG/HE, and CVM1/CV-series Motion Control Units,
recommended.) CX-Motion Ver.2.3
and to create and monitor motion control programs.
Memory 256 MB minimum (See note2.) 512 MB min. required.1 GB min. recommended
Hard disk Approx. 2.8 GB or more available space is required to install the complete CX-One package CX-Drive Ver.1.8 Application software to set and control data for Inverters and Servos.
Display SVGA (800 × 600) or better high-resolution display with 256 colors min
FA Communications Software
Application software to create and debug function block programs for SYSMAC CS/CJ-series Loop Controllers (Loop Control
CX-Process Tool Ver.5.2
Disk drive CD-ROM drive or DVD-ROM drive Units/Boards, Process Control CPU Units, and Loop Control CPU Units).
Communications ports RS-232C port, USB port, or Ethernet port (See note3.)
Faceplate Auto- Application software that automatically outputs screen data as project files for Ns-series PTs from tag information in function
Other Internet access is required for online user registration,including a modem or other hardware connection method Builder for NS Ver.3.1 block programs created with the CX-Process Tool.
2. The amount of memory required varies with the Support Software used in CX-One for the following Support Software. Refer to user NV-Designer Ver.1.0 Application software to create screen data for NV-series small PTs.
Ordering Information
and Faceplate Auto-Builder for NS.
CX-Thermo Ver.4.1 Application software to set and control parameters in components such as Temperature Control Units.
3. An RS-232C port is required to connect the Support Software in CX-One to a PLC. If the computer provides only a USB port, use a CS1W-CIF31
USB-to-RS-232C Conversion Cable. For connecting to the CP Series,however, an over-the-counter USB cable (type A-B) can be used.
For the CX-Drive, the CS1W-CIF31 USB-to-RS-232C Conversion Cable cannot be used to connect a USB port on the computer to the 3G3MV. CX-FLnet Ver.1.0 Application software for system setting and monitoring of SYSMAC CS/CJ-series Fl-net Units.
Use the recommended commercially available USB-serial conversion cable.For details, refer to the CX-Drive Programmable Controller
Operation Manual (Cat. No. W453). Network Configurator Ver.3.0 Application software to set up tag data links for CJ2 (Built-in EtherNet/IP) CPU Units and EtherNet/IP Units.
CX-One Lite
4. The following restrictions apply when CX-One is used with Microsoft Windows Vista.
CX-Server Ver.4.3 Middleware necessary for CX-One applications to communicate with OMRON components, such as PLCs, Display Devices, and Temperature Control Units.
1) Some Help files cannot be accessed.
The Help files can be accessed if the Help program distributed by Microsoft for Windows Vista (WinHlp32.exe) is installed. Refer to
the Microsoft homepage listed below or contact Microsoft for details on installing the file. A group of components used with CX-One applications, such as the CX-Programmer and CX-Integrator. Includes the following:
PLC Tools
(The download page is automatically displayed if the Help files are opened while the user is connected to the Internet.) (Installed automatically.) I/O tables, PLC memory, PLC Setup, Data Tracing/Time Chart Monitoring, PLC Error Logs, File Memory, PLC clock, Routing Tables, and Data Link Tables.
http://support.microsoft.com/kb/917607/en-us
2) Restrictions apply to operation of some applications. Refer to the Setup Manual for details.
20 21
Ordering Information
Position Control
Number of licenses Media Support Software in CX-One Outline
CD CXONE-AL01C-V3
1 licenses −
CX-Programmer Application software to create and debug programs for SYSMAC CS/CJ/CP/NSJseries, C-series, and CVM1/C-series CPU Units.
DVD CXONE-AL01D-V3 Ver.8.2
Data can be created and monitored for high-speed-type Position Control Units.
The CX-One is a
CD CXONE-AL03C-V3
comprehensive software −
3 licenses
package that integrates
Network
DVD CXONE-AL03D-V3 Application software to build and set up FA networks, such as Controller Link, DeviceNet, CompoNet, CompoWay, and Ethernet networks.
Support Software for OMRON CX-Integrator Ver.2.3
The Routing Table Component and Data Link Component can be started from here. DeviceNet Configuration functionality is also included.
FA Integrated Tool
PLCs and components. CD CXONE-AL10C-V3
Package CX-One 10 licenses −
Ver. 3.2 CX-One runs on DVD CXONE-AL10D-V3 Utility software that helps you to debug PLCs. It helps you to monitor the I/O status and to monitor/change present values within
Switch Box Utility Ver.1.6
the following OS. the PLC you specify.
CD CXONE-AL30C-V3
Batch Backup
Windows 2000
30 licenses −
(Service Pack 3 or higher), DVD CXONE-AL30D-V3
XP, or Vista Application software to create protocols (communications sequences) between SYSMAC CS/CJ/CP/NSJ-series or
CX-Protocol Ver.1.8
CD CXONE-AL50D-V3 C200HX/HG/HE Serial Communications Boards/Units and general-purpose external devices.
50 licenses −
DVD CXONE-AL50D-V3
Easy Programming
Application software to simulate SYSMAC CS/CJ/CP/NSJ-series CPU Unit operation on the computer to debug PLC programs
Note 1. Site licenses are available for users who will run CX-One on multiple computers. Ask your OMRON sales representative for details. CX-Simulator Ver.1.9
without a CPU Unit.
2. When purchasing the DVD format, verify the computer model and DVD drive specifications before purchasing.
CX-Position Ver.2.5 Application software to create and monitor data for SYSMAC CS/CJ-series Position Control Units.
System Requirements
Application software to monitor and set parameters for SYSMAC CS/CJ-series Position Control Units and Servo Drivers
CX-Motion-NCF Ver.1.8
Debugging
that support MECHATROLINK-II communications.
Item Requirement
Component Tools
by Microsoft. (1 GHz or faster recommended) Application software to create data for SYSMAC CS/CJ-series, C200HX/HG/HE, and CVM1/CV-series Motion Control Units,
recommended.) CX-Motion Ver.2.3
and to create and monitor motion control programs.
Memory 256 MB minimum (See note2.) 512 MB min. required.1 GB min. recommended
Hard disk Approx. 2.8 GB or more available space is required to install the complete CX-One package CX-Drive Ver.1.8 Application software to set and control data for Inverters and Servos.
Display SVGA (800 × 600) or better high-resolution display with 256 colors min
FA Communications Software
Application software to create and debug function block programs for SYSMAC CS/CJ-series Loop Controllers (Loop Control
CX-Process Tool Ver.5.2
Disk drive CD-ROM drive or DVD-ROM drive Units/Boards, Process Control CPU Units, and Loop Control CPU Units).
Communications ports RS-232C port, USB port, or Ethernet port (See note3.)
Faceplate Auto- Application software that automatically outputs screen data as project files for Ns-series PTs from tag information in function
Other Internet access is required for online user registration,including a modem or other hardware connection method Builder for NS Ver.3.1 block programs created with the CX-Process Tool.
2. The amount of memory required varies with the Support Software used in CX-One for the following Support Software. Refer to user NV-Designer Ver.1.0 Application software to create screen data for NV-series small PTs.
Ordering Information
and Faceplate Auto-Builder for NS.
CX-Thermo Ver.4.1 Application software to set and control parameters in components such as Temperature Control Units.
3. An RS-232C port is required to connect the Support Software in CX-One to a PLC. If the computer provides only a USB port, use a CS1W-CIF31
USB-to-RS-232C Conversion Cable. For connecting to the CP Series,however, an over-the-counter USB cable (type A-B) can be used.
For the CX-Drive, the CS1W-CIF31 USB-to-RS-232C Conversion Cable cannot be used to connect a USB port on the computer to the 3G3MV. CX-FLnet Ver.1.0 Application software for system setting and monitoring of SYSMAC CS/CJ-series Fl-net Units.
Use the recommended commercially available USB-serial conversion cable.For details, refer to the CX-Drive Programmable Controller
Operation Manual (Cat. No. W453). Network Configurator Ver.3.0 Application software to set up tag data links for CJ2 (Built-in EtherNet/IP) CPU Units and EtherNet/IP Units.
CX-One Lite
4. The following restrictions apply when CX-One is used with Microsoft Windows Vista.
CX-Server Ver.4.3 Middleware necessary for CX-One applications to communicate with OMRON components, such as PLCs, Display Devices, and Temperature Control Units.
1) Some Help files cannot be accessed.
The Help files can be accessed if the Help program distributed by Microsoft for Windows Vista (WinHlp32.exe) is installed. Refer to
the Microsoft homepage listed below or contact Microsoft for details on installing the file. A group of components used with CX-One applications, such as the CX-Programmer and CX-Integrator. Includes the following:
PLC Tools
(The download page is automatically displayed if the Help files are opened while the user is connected to the Internet.) (Installed automatically.) I/O tables, PLC memory, PLC Setup, Data Tracing/Time Chart Monitoring, PLC Error Logs, File Memory, PLC clock, Routing Tables, and Data Link Tables.
http://support.microsoft.com/kb/917607/en-us
2) Restrictions apply to operation of some applications. Refer to the Setup Manual for details.
20 21
Ordering Information
CX-One Lite
Related Products
“ One Software” for our Compact PLCs
SYSMAC Gateway We’ve upgraded the CX-One Lite Software Package which is designed specifically for low end systems.
Position Control
Product name Specifications Model Standards When using Compact PLCs only, the CX-One Lite is your cost effective programming and configuration tool.
Supported OS: Microsoft Windows Vista, XP, 2000, and 2003 Server Note1.One license is required for each computer.
Network
A software development kit called the SYSMAC Gateway SDK is also available to write communications programs Micro PLC Edition CX-Programmer provides a Smart Input
for the SYSMAC Gateway.
function for intuitive software operation to simplify
programming.
Compolet Support Software applications for the NS-series HMIs,
Lite NV-series HMIs, and Temperature Controllers are also included for
Batch Backup
Product name Specifications Model Standards simple setup operations.
Software components that can make it easy to create programs Total lead time until the system is up and running is reduced.
for communications between a computer and controllers. −
CX-Compolet This packaged product bundles SYSMAC Gateway.
(See note.1) WS02-CPLC1
Development environment : Visual Studio .NET 2003, .NET 2005, or .NET 2008
Development languages : Visual Basic .NET, Visual C#.NET, Visual Basic Ver.5/6 (See note.2)
Easy Programming
Supported communications : Equal to SYSMAC Gateway
Supported OS: Microsoft Windows Vista, XP, 2000, and 2003 Server Note1.One license is required for each computer.
Smart Input Select from Several Key Allocations
You can also purchase the CX-Compolet without the SYSMAC Gateway. Order WS02-CPLC2. 2. Only functions provided by Compolet
V2 as ActiveX controls are supported for Intuitive ladder programming is possible with help functions to You can select any familiar key allocations from those for the
Visual Basic version 5 or 6 enter instructions and addresses, increment addresses, perform SYSMAC Support Software or those for ladder programming
additive address copying, and more. software from other companies to enable smooth operation no
Debugging
matter which allocations you are accustomed to, or you can
customize shortcut keys to suit your own needs.
Guidance display
Component Tools
Note:
The Smart Input function is
provided only with the
Limited-version
CX-Programmer for Micro
PLCs version 9.0 and
CX-Programmer for CP1E
version 1.0.
FA Communications Software
Support Software in CX-One
The following tables lists the Support Software that can be installed from CX-One
Ordering Information
Applicable models: CP1 , CPM , SRM1
Ordering information
CX-One Lite
Product name Specifications Model Standards
Number of licenses Media
22 23
Ordering Information
CX-One Lite
Related Products
“ One Software” for our Compact PLCs
SYSMAC Gateway We’ve upgraded the CX-One Lite Software Package which is designed specifically for low end systems.
Position Control
Product name Specifications Model Standards When using Compact PLCs only, the CX-One Lite is your cost effective programming and configuration tool.
Supported OS: Microsoft Windows Vista, XP, 2000, and 2003 Server Note1.One license is required for each computer.
Network
A software development kit called the SYSMAC Gateway SDK is also available to write communications programs Micro PLC Edition CX-Programmer provides a Smart Input
for the SYSMAC Gateway.
function for intuitive software operation to simplify
programming.
Compolet Support Software applications for the NS-series HMIs,
Lite NV-series HMIs, and Temperature Controllers are also included for
Batch Backup
Product name Specifications Model Standards simple setup operations.
Software components that can make it easy to create programs Total lead time until the system is up and running is reduced.
for communications between a computer and controllers. −
CX-Compolet This packaged product bundles SYSMAC Gateway.
(See note.1) WS02-CPLC1
Development environment : Visual Studio .NET 2003, .NET 2005, or .NET 2008
Development languages : Visual Basic .NET, Visual C#.NET, Visual Basic Ver.5/6 (See note.2)
Easy Programming
Supported communications : Equal to SYSMAC Gateway
Supported OS: Microsoft Windows Vista, XP, 2000, and 2003 Server Note1.One license is required for each computer.
Smart Input Select from Several Key Allocations
You can also purchase the CX-Compolet without the SYSMAC Gateway. Order WS02-CPLC2. 2. Only functions provided by Compolet
V2 as ActiveX controls are supported for Intuitive ladder programming is possible with help functions to You can select any familiar key allocations from those for the
Visual Basic version 5 or 6 enter instructions and addresses, increment addresses, perform SYSMAC Support Software or those for ladder programming
additive address copying, and more. software from other companies to enable smooth operation no
Debugging
matter which allocations you are accustomed to, or you can
customize shortcut keys to suit your own needs.
Guidance display
Component Tools
Note:
The Smart Input function is
provided only with the
Limited-version
CX-Programmer for Micro
PLCs version 9.0 and
CX-Programmer for CP1E
version 1.0.
FA Communications Software
Support Software in CX-One
The following tables lists the Support Software that can be installed from CX-One
Ordering Information
Applicable models: CP1 , CPM , SRM1
Ordering information
CX-One Lite
Product name Specifications Model Standards
Number of licenses Media
22 23
N EW
CX-One
CXONE-AL C-V3/-AL
Ver.3.
D-V3
CXONE-LTO1C-V4
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL
DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE
PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE,
OR STRICT LIABILITY.
The application examples provided in this catalog are for reference only. Check functions and
In no event shall the responsibility of OMRON for any act exceed the individual price of the safety of the equipment before use.
product on which liability is asserted. Never use the products for any application requiring special safety requirements, such as nuclear
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER
CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE
energy control systems, railroad systems, aviation systems, medical equipment, amusement
machines, vehicles, safety equipment, or other application involving serious risk to life or property,
CX-One Lite
PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR
without ensuring that the system as a whole has been designed to address the risks, and that the
OMRON products are properly rated and installed for the intended use within the overall
Upgrade
REPAIR. equipment or system.