Object XMLDocument
Object XMLDocument
TEP 200WIR Series, 180 240 Watt Features Chassis mount with screw terminal block Including EMI filter to meet
EN 55022, class A 8.536, 16.575, 43160 VDC
g din n pe
Ultra wide 4:1 input voltage ranges EN 50155 approval for railway
applications
Very high efficiency up to 91% No minimum load Soft start Under voltage lock-out circuit Ajustable output voltage +10/-20% Sense line Remote On/Off input Reverse input voltage protection Over temperature protection 3-year product warranty Standard Models
Order code TEP 2002412WIRCMF TEP 2002413WIRCMF TEP 2002415WIRCMF TEP 2002416WIRCMF TEP 2002418WIRCMF TEP 2004812WIRCMF TEP 2004813WIRCMF TEP 2004815WIRCMF TEP 2004816WIRCMF TEP 2004818WIRCMF TEP 2007212WIRCMF TEP 2007213WIRCMF TEP 2007215WIRCMF TEP 2007216WIRCMF TEP 2007218WIRCMF Input voltage 8.5 36 VDC (24 VDC nominal)
The TEP 200WIR Series is a family of isolated high performance dc-dc converter modules with ultra-wide 4:1 input voltage ranges. They come in chassis mount version with screw terminal block and with integrated EMI input filter to meet EN 55022 class A. A very high efficiency allows full power operation at 25C with only 100 LFM air flow couling and operation at 60C with only 40% power derating. The very wide input voltage range and reverse input voltage protection make these converters interesting solution for battery operated systems. Typical applications are in telecom/datacom, industry control and railway systems for on board power distribution.
Output voltage 12 VDC 15 VDC 24 VDC 28 VDC 48 VDC 12 VDC 15 VDC 24 VDC 28 VDC 48 VDC 12 VDC 15 VDC 24 VDC 28 VDC 48 VDC
Efficiency typ. 89 % 90 % 90 % 90 % 89 % 90 % 91 % 90 % 91 % 90 % 89 % 90 % 89 % 90 % 89 %
Options
TEP-MK1 Din-rail mounting kit (incl. mounting screws) Models with 3.3 VDC or 5.0 VDC output Models with 53 VDC output (input voltage range 33 - 75 VDC) Models with 2:1 input voltage ranges: 8.5-22, 16.5-36, 33-75 VDC (only to optimize cost at high volumes) Models for PCB mount (EMI Filter not included), optional heatsink and chokes for external filter Negative (passive = Off) Remote On/Off function (standard is passive = On)
on demand
http://www.tracopower.com
Page 1 of 5
DC/DC Converters
Input Specifications
Input current at no load (nominal input voltage) Start-up voltage Under voltage shut down (lock-out circuit) Surge voltage (1 sec. max.) 24 V models: 40 mA typ. 48 V models: 20 mA typ. 110 V models: 15 mA typ. 24 V models: 9.0 VDC max. 48 V models: 18 VDC max. 110 V models: 43 VDC max. 24 V models: 7.3 8.1 VDC 48 V models: 15.5 16.3 VDC 110 V models: 33.0 36.0 VDC 24 V models: 50 VDC 48 V models: 100 VDC 110 V models: 185 VDC
Conducted noise EN 55022 class A without external components ESD (electrostatic discharge) EN 61000-4-2, air 8 kV, contact 6 kV, perf. criteria A Radiated immunity EN 61000-4-3, 20 V/m, perf. criteria A Fast transient / Surge EN 61000-4-4, 2 kV, perf. criteria A EN 61000-4-5, 2 kV perf. criteria A With external input capacitor: 24/48V models: chemi-con KY 200 F, 100 V, ESR 48 mOhm 72 V models: ruby-con BXF 100 F, 250 V Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A Reverse voltage protection parallel diode 24 V models: 20 A 48/72 V models: 10 A Recommended input fuse (slow blow)
Output Specifications
Voltage set accuracy (at full load, nominal input) 1 % Output voltage adjustment +10 % / 20 % by external resistor see application note Regulation Input variation Vin min. to Vin max. 0.2 % max. Load variation (0 100 %) 12 / 15 VDC models: 0.25 % max. 24 48 VDC models: 0.2 % max. Temperature coefficient 0.02 %/K Minimum load not required Remote sense 10 % max. of Vout nom. (trim up value to subtract) Ripple and noise (20 MHz Bandwidth) 12 / 15 VDC models: 100 mVp-p typ. 24 / 28 VDC models: 200 mVp-p typ. 48 VDC models: 300 mVp-p typ. Start up time (nominal Vin and constant resistive load) 75 ms typ. (at power On or remote On/Off) Transient response (25 % load step change) 250 s typ. Output current limitation at 120 150 % of Iout max. Over voltage protection at 115 130 % of Vout nom. Short circuit protection indefinite, automatic recovery. Max. capacitive load [F] 24 VDC Input models 48 VDC Input models 110 VDC Input models http://www.tracopower.com 12 VDC 12500 15000 16600 15 VDC 8000 9300 16600 24 VDC 3100 3700 4100 28 VDC 2300 2600 3000 48 VDC 770 930 1000 Page 2 of 5
DC/DC Converters
General Specifications
Temperature ranges Operating 40C to +75C Case temperature +115C max. Storage 55C to +125C
Derating (convection cooling) depending on installation! Guideline values: approx. 1.2 %/K above +25C please refer to application note for temperature measure point that should not exceed 115C. Over temperature protection at +120C Thermal shock, mechanical shock & vibration EN 61373, MIL-STD-810F Test conditions www.tracopower.com/products/mil810.pdf Humidity (non condensing) 95 % rel H max. Reliability, calculated MTBF (MIL-HDBK-217F, at +25C, ground benign) 75000 h Isolation voltage (60sec.) Isolation capacitance Isolation resistance Input/Output 2250 VDC (basic insulation) Input/Case 1600 VDC Input/Output 2500 pF max. Input/Output (500 VDC) >1 GOhm min.
Switching frequency 250 kHz typ. (puls width modulation) Safety standards EN 50155, UL 60950-1, IEC/EN 60950-1 Safety approvals UL/cUL (entry pending) www.ul.com -> certifications -> File e188913 Railway www.tracopower.com/products/tep-coc.pdf 3 to 12 VDC or open circuit 0 to 1.2 VDC or short circuit pin 1 and 3 0 to 1.2 VDC or short circuit pin 1 and 3 3 to 12 VDC or open circuit 3 mA
Remote On/Off positive logic (standard) On: Off: negative logic (option) On: Off: Off idle current: Environmental compliance
All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. http://www.tracopower.com Page 3 of 5
DC/DC Converters
General Specifications
Casing material metal Potting material silicon (UL94V-0 rated) Base material FR4
Dimensions
Pin-Out
Pin 1 2 3 4 5 6 7 8 9 Vin Case Remote On/Off + Vin Vout Sense* Trim + Sense* + Vout
*Sense line to be connected to the output either at the module or at the load under regard of polarity.
Dimensions in Inch, () = mm Tolerances 0.02 (0.5) Pin pich tolerances 0.01 (0.25) Mounting hole pich tolerances 0.01 (0.25)
http://www.tracopower.com
Page 4 of 5
DC/DC Converters
Options
Jenatschstrasse 1 CH-8002 Zurich Switzerland Tel. +41 43 311 45 11 Fax +41 43 311 45 45 [email protected] www.tracopower.com
Page 5 of 5