InstructionsParts List

308883L
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
50:1 Fire-Ball
R
300 Pumps
For pumping noncorrosive and nonabrasive
greases and lubricants only.
Model No. 239877, Series D, pail length
Model No. 239887, Series D, 120-pound drum length
Model No. 239888, Series D, 400-pound drum length
8400 psi (58 MPa, 580 bar) Maximum Working Pressure
140 psi (0.97 Ma, 9.7 bar) Maximum Air Input Pressure
Table of Contents
Warnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting 9 . . . . . . . . . . . . . . . . . . . . . . . . . .
Displacement Pump Service 10 . . . . . . . . . . . . . .
Air Motor and Throat Service 12 . . . . . . . . . . . . . .
Parts Drawing 16 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts List 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensional Drawings 18 . . . . . . . . . . . . . . . . . . .
Mounting Hole Layout 18 . . . . . . . . . . . . . . . . . . . .
Technical Data 19 . . . . . . . . . . . . . . . . . . . . . . . . . .
Warranty 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Graco Phone Number 20 . . . . . . . . . . . . . . . . . . . .
WARNING
This product is designed to be used only in pump-
ing non-corrosive and non-abrasive lubricants and
greases. Any other use can cause unsafe operat-
ing conditions and result in component rupture,
fire, or explosion, which can cause serious injury,
including fluid injection.
Model No. 239887 shown
9038B

2 308883L
Symbols
Warning Symbol
WARNING
This symbol alerts you to the possibility of serious
injury or death if you do not follow the instructions.
Caution Symbol
CAUTION
This symbol alerts you to the possibility of damage to
or destruction of equipment if you do not follow the
instructions.
WARNING
EQUIPMENT MISUSE HAZARD
Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
D This equipment is for professional use only.
D Read all instruction manuals, tags, and labels before you operate this equipment.
D Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.
D Do not modify this equipment.
D Check equipment daily. Repair or replace worn or damaged parts immediately.
D Do not exceed the maximum working pressure of the lowest rated component in your system.
This equipment has a 8400 psi (58 MPa, 580 bar) maximum working pressure at 140 psi
(0.97 MPa, 9.7 bar) maximum incoming air pressure.
D Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the
Technical Data section of all equipment manuals. Read the fluid and solvent manufacturers
warnings.
D Handle hoses carefully. Do not pull on hoses to move equipment.
D Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not ex-
pose Graco hoses to temperatures above 66_C (150_F) or below 40_C (40_F).
D Do not move or lift pressurized equipment.
D Comply with all applicable local, state, and national fire, electrical, and safety regulations.
3 308883L
TOXIC FLUID HAZARD
Hazardous fluids or toxic fumes can cause serious injury or death if splashed in the eyes or on the
skin, inhaled, or swallowed.
D Know the specific hazards of the fluid you are using.
D Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local,
state and national guidelines.
D Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid
and solvent manufacturer.
SKIN INJECTION HAZARD
Fluid from the dispensing valve, leaks, or ruptured components can inject fluid into your body and
cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on
the skin can also cause serious injury.
D Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate
surgical treatment.
D Do not point the dispensing valve at anyone or at any part of the body.
D Do not put your hand or fingers over the end of the dispensing valve.
D Do not stop or deflect leaks with your hand, body, glove or rag.
D Use only extensions and no-drip tips which are designed for use with your dispensing valve.
D Do not use a low pressure flexible nozzle with this equipment.
D Follow the Pressure Relief Procedure on page 8 if the grease fitting coupler clogs and before
you clean or service this equipment.
D Tighten all fluid connections before you operate this equipment.
D Check the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. Do
not repair high pressure couplings; you must replace the entire hose.
WARNING
4 308883L
MOVING PARTS HAZARD
Moving parts, such as the air motor piston, can pinch or amputate your fingers.
D Do not operate the pump with the air motor plates removed.
D Keep clear of all moving parts when you start or operate the pump.
D Before you service this equipment, follow the Pressure Relief Procedure on page 8 to prevent
the equipment from starting unexpectedly.
FIRE AND EXPLOSION HAZARD
Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and
result in a fire or explosion and serious injury.
D Ground the equipment and the object being dispensed to. Refer to Grounding below.
D If there is any static sparking or you feel an electric shock while using this equipment, stop
dispensing immediately. Do not use the equipment until you identify and correct the problem.
D Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid
being dispensed.
D Keep the dispensing area free of debris, including solvent, rags, and gasoline.
D Do not smoke in the dispensing area.
WARNING
5 308883L
Notes
6 308883L
Installation
Grounding
Proper grounding is an essential part of maintaining a
safe system.
To reduce the risk of static sparking, ground the pump.
Check your local electrical code for detailed grounding
instructions for your area and type of equipment.
Ground all of this equipment:
D Pump: Use a ground wire and clamp as shown
in Fig. 1.
D Fluid hoses: Use only electrically conductive hoses.
D Air compressor: Follow the manufacturers recom-
mendations.
D Fluid supply container: Follow the local code.
D To maintain grounding continuity when flushing or
relieving pressure, always hold a metal part of the
valve firmly to the side of a grounded metal pail,
then trigger the valve.
To ground the pump, remove the ground screw (Z)
and insert through the eye of the ring terminal at end of
the ground wire (Y). Fasten the ground screw back
onto the pump and tighten securely. Connect the other
end of the ground wire to a true earth ground. See Fig.
1. To order a ground wire and clamp, order Part No.
222011.
Fig. 1
TI1052
Y
Z
Fig. 2
For Stationary Mountings
KEY
A Fluid dispense line
B Pump ground wire (required)
C Air regulator with gauge
D Main air supply line
E Air line filter
F Air line lubricator
G Pump runaway valve
H Follower plate
J Bleed-type Master Air Valves
(required)
K Fluid drain valve
Recommended air line
configuration to reduce
moisture in pump
1/2 in.
B
C
D
E
F
G
H
J
A
04191C
J
K
7 308883L
Installation
Mounting
WARNING
Mount the pump securely so that it cannot move
around during operation. Failure to do so could
result in personal injury or equipment damage.
1. Plan the mounting layout for easy operator access
to the pump air controls, sufficient room to change
drums and a secure mounting platform.
2. If using a follow plate (H), remove the drum cover.
Scoop the material to the center of the drum.
Place the plate on the material. Guide the pump
foot valve through the plate.
3. Mount the pump to the drum cover or other suit-
able mounting device.
4. For ease in changing drums, install a pump eleva-
tor.
Air and Fluid Line and Accessories
See Fig. 2 above.
Three accessories are required in your system: an
air shut-off valve/air bleed device, fluid drain valve,
and ground wire. These accessories help reduce
the risk of serious bodily injury, including fluid
injection, splashing in the eyes or on the skin,
injury from moving parts if you are adjusting or
repairing the pump, and explosion from static
sparking.
D The air bleed device relieves air trapped be-
tween it and the air motor after the air supply is
shut off. Trapped air can cause the air motor to
cycle unexpectedly, causing serious injury if you
are adjusting or repairing the pump. Use a
bleed-type master air valve (J). Install them
near the pump air inlet within easy reach from
the pump.
D The fluid drain valve (K) assists in relieving fluid
pressure in the displacement pump, hoses, and
dispensing valve. Triggering the valve to relieve
pressure may not be sufficient.
D The ground wire (B) reduces the risk of static
sparking.
WARNING
CAUTION
Do not hang the air accessories directly on the air
inlet. The fittings are not strong enough to support
the accessories and may cause one or more to
break. Provide a bracket on which to mount the
accessories.
NOTE: Install the air line accessories in the order
shown in Fig. 2.
1. Install a pump runaway valve (G) to shut off the air
to the pump if the pump accelerates beyond the
pre-adjusted setting. A pump that runs too fast can
be seriously damaged.
2. Install an air line lubricator (F) for automatic air
motor lubrication.
3. Install a bleed-type master air valve (J) to relieve
air trapped between the valve and the motor (see
WARNING at left). Order Part No. 107142.
4. Install the air regulator (C) to control pump speed
and pressure (see WARNING at left).
5. Install an air line filter (E) to remove harmful dirt
and contaminants from your compressed air
supply.
6. Install a second bleed-type master air valve (J)
upstream from all other accessories, to isolate the
accessories for servicing.
8 308883L
Operation
Pressure Relief Procedure
SKIN INJECTION HAZARD
The equipment stays pressurized until
pressure is manually relieved. To reduce
the risk of serious injury from
pressurized fluid, fluid from the valve or splashing
fluid, follow this procedure whenever you
D Are instructed to relieve pressure
D Stop dispensing
D Check, clean or service any system equipment
D Install or clean dispensing devices
WARNING
1. Close the pump air regulator and the bleed-type
master air valve (required in your system).
2. Hold a metal part of the dispensing valve firmly to
a grounded metal waste container and trigger the
valve to relieve the fluid pressure.
Startup
1. If there are multiple pumps on the air line, close
the air regulators and bleed-type master air valves
to all but one pump. If there is only one pump,
close its air regulator and bleed-type master air
valve.
2. Open the master air valve from the compressor.
3. Open the dispensing valve into a grounded metal
waste container, making firm metal-to-metal con-
tact between the container and valve. Open the
bleed-type master air valve and open the pump air
regulator slowly, just until the pump is running.
When the pump is primed and all air has been
pushed out of the lines, close the dispense valve.
4. If you have more than one pump, repeat this
procedure for each pump.
NOTE: When the pump is primed, and with sufficient
air supplied, the pump starts when the dispensing
valve is opened and shuts off when it is closed.
5. Set the air pressure to each pump at the lowest
pressure needed to get the desired results.
COMPONENT RUPTURE HAZARD
The maximum working pressure of each
component in the system may not be the
same. To reduce the risk of
overpressurizing any component in the system, be
sure you know the maximum working pressure of
each component. Never exceed the maximum
working pressure of the lowest rated component in
the system. Overpressurizing any component can
result in rupture, fire, explosion, property damage,
and serious injury.
The pump has a rated ratio of 50:1. However, it is
capable of reaching stall pressures equal to 60
times the air input pressure. Calculate the fluid
output pressure using the air regulator reading.
Multiply the air pressure shown on the regulator
gauge by 60. For example:
140 psi air x 60 = 8400 psi fluid output
0.97 MPa air x 60 = 58.2 MPa fluid output
9.7 bar air x 60 = 582 bar fluid output
Regulate air to the pump so that no air line or fluid
line component or accessory is overpressurized.
WARNING
6. Never allow the pump to run dry of the material
being pumped.
CAUTION
A dry pump will quickly accelerate to a high speed,
possibly damaging itself. If your pump accelerates
quickly, or is running too fast, stop it immediately and
check the material supply. If the supply container is
empty and air has been pumped into the lines, prime
the pump and lines with material, or flush it and leave
it filled with a compatible solvent. Be sure to elimi-
nate all air from the material lines.
NOTE: A pump runaway valve (G) can be installed on
the air line to automatically shut off the pump if it starts
to run too fast.
7. Read and follow the instructions supplied with
each component in your system.
8. To shut off the system, always follow the Pressure
Relief Procedure at the left.
9 308883L
Troubleshooting
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
Relieve pressure before you check or service any
system equipment.
MOVING PARTS HAZARD
Never operate the pump with the
warning plate or the identification plate
removed. These plates protect your
fingers from pinching or amputation by moving
parts in the air motor.
WARNING
Problem Cause Solution
Pump fails to operate Inadequate air supply pressure or
restricted air lines
Increase air supply and/or
clear restriction.
Closed or clogged pump valves Open and/or clean.
Clogged fluid line, hose, valve, or
other accessory
Relieve pressure.
Clear obstruction.
Damaged air motor Assess damage, and service
air motor.
Exhausted fluid supply Refill and reprime or flush.
Continuous air exhaust Worn or damaged air motor
gasket or seal
Assess wear or damage,
and service air motor.
Erratic pump operation Exhausted fluid supply Refill and reprime or flush
Worn pump seals Replace.
Damaged shovel tube Replace.
Damaged check seat Replace pump piston or
shovel rod (or other dam-
aged part).
Pump operates, but output low on
up stroke
Worn piston seal Replace.
Damaged upper check seat Replace pump piston.
Pump operates, but output low on
down stroke
Worn fluid intake seal Replace.
Damaged lower check seat Replace shovel rod.
Pump operates, but output low on
both strokes
Inadequate air supply pressure or
restricted air lines
Increase air supply and/or
clear restriction.
Closed or clogged pump valves Open and/or clean.
Exhausted fluid supply Refill fluid supply, and
reprime pump.
Clogged fluid line, hose, valve, or
other accessory
Relieve pressure.
Clear obstruction.
Worn seals Replace.
Grease leaking from muffler plates Worn throat seal Replace.
10 308883L
Displacement Pump Service
D Be sure you have all necessary parts on hand
before you start. If using a repair kit, use all the
parts in the kit for the best results.
D Displacement Pump Repair Kit 241623 is available.
Parts included in the kit are marked with a dag-
ger ({) in the parts drawing and list.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
1. Flush the pump.
2. Relieve the pressure before you proceed.
3. Disconnect the hoses, remove the pump from its
mounting, and clamp the air motor base (5) in a
vise.
CAUTION
To avoid damaging the shovel tube, do not use
slots in the tube to tighten or loosen tube.
4. Use strap wrench to screw shovel tube (67) off of
pump cylinder (59).
5. Use strap wrench to screw shovel (66) off of
shovel rod (58).
6. Use strap wrench on pump cylinder (59) to screw it
out of extension tube (64). Screw tube connector
(63) out of pump cylinder. Remove bearing (61)
and seal (62).
7. Screw the shovel rod (58) out of the piston (52).
Remove the lower ball (56). Screw the piston out
of the extension rod (57). Remove the upper ball
(56), retaining washer (53), and seal (54).
8. Clean all the parts in a compatible solvent and
inspect them for wear or damage. Use all the parts
in the repair kit, and replace other parts as neces-
sary.
9. Generously lubricate all the parts with light water-
resistant grease and reassemble the pump.
NOTES:
Torque the shovel tube (67) to the pump cylinder
(59) at 45 to 55 ft-lb (61 to 75 N-m), and torque the
pump cylinder (59) to the extension tube (64) at
45 to 55 ft-lb (61 to 75 N-m).
Torque the shovel rod (58) to the piston (52) at 25
to 30 ft-lb (34 to 41 N-m), and torque piston (52) to
the extension rod (57) at 25 to 30 ft-lb (34 to 41
N-m).
10. If the ground wire was disconnected before servic-
ing, be sure to reconnect it before you operate the
pump.
11 308883L
Displacement Pump Service
Fig. 3
1
3
4
Using nut (63), torque the
pump cylinder (59) to the ex-
tension tube (64) at 4555 ft-lb
(6175 NSm).
Torque the shovel rod (58)
to the piston (52) at 2530
ft-lb (3441 NSm).
Torque the piston (52) to the
extension rod (57) at 2530
ft-lb (3441 NSm).
5
60
64
59
56
52
62
61
63
58
57
53
54
67
66
4
3
1
Caution: Do not use
slots in shovel tube to
tighten or loosen tube.
9040B
12 308883L
Air Motor and Throat Service
D Before you start, be sure you have all necessary
parts on hand. Repair Kit 206728 is available for
the motor. Use all the parts in the kit for the best
results. Parts included in the kit are marked with an
asterisk (*) in the parts drawing and list.
D Two accessory tools should be ordered. Use
Padded Pliers, 207579, to grip the trip rod without
damaging its surface. Use Gauge, 171818, to
ensure the proper clearance between the poppets
and seat of the transfer valve.
Disassembly
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
1. Flush the pump.
2. Relieve the pressure before you proceed.
3. Disconnect the hoses, remove the pump from its
mounting, and clamp the air motor base (5) in a
vise.
4. Use a strap wrench or pipe wrench on the exten-
sion tube (64) to screw it out of the base (5). See
Fig. 4.
5. Pull the extension rod (57) down as far as it will go,
exposing the displacement rod (8).
6. Use a hammer and punch to remove the roll pin
(74) from the displacement rod (8), and unscrew
the extension rod (57) out of the displacement rod.
CAUTION
In step 7, do not damage the plated surface of the
trip rod (11). A damaged trip rod could cause
erratic air motor operation. Use the special padded
pliers, 207579, to grasp the rod.
7. Manually push on the displacement rod (8) to
move the air motor piston (2) up as far as it will go.
Unscrew the cylinder cap nut (29a or 29b). Pull the
nut up. Grip the trip rod (11) with padded pliers,
and screw the nut off the rod. See Fig. 4.
8. Remove the six screws (21) that hold the cylinder
(17) to the base. Carefully pull the cylinder straight
up off the piston (2).
CAUTION
To avoid damaging the cylinder wall, lift the cylinder
straight up off of the piston. Never tilt the cylinder
while you are removing it.
WARNING
To reduce the risk of pinching or amputating your
fingers, always keep fingers clear of the toggle
assemblies (L). See Fig. 5.
9. Use a screwdriver to push down on the trip rod
yoke (22), and snap the toggles down. Remove
the lockwires (31) from the adjusting nuts (30) of
the transfer valves. Screw the top nuts off. Screw
the stems (1a) out of the grommets (12) and
bottom nuts. Take the valve poppets (1b) off the
stems and squeeze them firmly to check for
cracks. See Fig. 5.
10. Grip the toggle rockers (26) with a pliers. Com-
press the springs (27), and swing the toggle as-
sembly (L) up and away from the piston lugs (M),
and remove the parts. Check to see that the valve
actuator (13) is supported by the spring clips (14),
but slides easily into them. See Fig. 5.
11. Remove the trip rod yoke (22), actuator (13), and
trip rod (11). Check the exhaust valve poppets (16)
for cracks.
NOTE: To remove cracked exhaust valve poppets
(16), stretch them out, and cut them with a sharp knife.
12. Remove one of the air motor plates (18 or 20). Pull
the piston (2) up out of the base (5). Remove the
throat packing nut (38) and throat seal (6).
13 308883L
Air Motor and Throat Service
Fig. 4
Torque the extension tube (64) to the base
(5) at 45 to 55 ft-lb (61 to 75 N-m).
5
8
57
64
74
2
11
21
17
38
6
9040B
14 308883L
Air Motor and Throat Service
Reassembly
1. Clean all the parts carefully in a compatible sol-
vent, and inspect for wear or damage. Use all the
repair kit parts during reassembly, and replace
other parts as necessary.
2. Check the polished surfaces of the piston (2),
displacement rod (8), and cylinder (17) wall for
scratches or wear. A scored rod causes premature
throat seal wear and leaking.
3. Lubricate all parts with a light, water-resistant
grease.
4. Install the new throat seal (6), lips facing down.
Screw the packing nut (38) into the base (5).
5. Slide the displacement rod (8) down through the
throat, and lower the piston (2) into the base (5).
Be sure the o-rings (9, 10, and 24) are in place.
See Fig. 4.
6. Pull the exhaust valve poppets (16) into the valve
actuator (13), and clip off the top part shown with
dotted lines in Fig. 5.
7. Install the transfer valve grommets (12), and
reassemble the valve mechanism. Before you
install the lockwires (31) in the adjusting nuts (30),
use the special gauge, 171818, to adjust the
transfer valve so there is 0.145 in. (3.7 mm) clear-
ance between the poppets (1b) and the seat when
it is open. See Fig. 5. Snap the toggles (25) to the
up position.
8. Reassemble the air motor, and assemble to the
displacement pump. Torque the extension tube
(64) to to base (5) at 45 to 55 ft-lb (61 to 75 N-m).
Before you install the air motor plate, tighten the
throat packing nut (38) snugly; do not overtighten
it.
9. Before you remount the pump, connect an air
hose, and run the pump slowly, at about 40 psi
(276 kPa, 2.8 bar), to see that it operates
smoothly.
10. Reconnect the ground wire before regular opera-
tion of the pump.
Fig. 5
1
2
04118
04119
14
16
31
30
1b
12
1b
2
11 22
M
26 27 25
L
1 Turn wires up.
2
Push toggles (L) in and then up.
13
14
11
0.145 in.
(3.7 mm)
2
1b
16
1a
30
12
30
24
Cutaway View
3 Cut off tops of poppets as indicated by dotted lines.
30
3
15 308883L
Notes
16 308883L
Parts Drawing
Model No. 239877, Series D, pail length
Model No. 239887, Series D, 120-pound drum length
Model No. 239888, Series D, 400-pound drum length
* The replacements for these parts are available in
Air Motor Repair Kit 206728. Purchase the kit separately.
** The replacements for these parts are available in
Muffler Repair Kit 222559. Purchase the kit separately.
{ The replacements for these parts are available in
Pump Repair Kit 241623. Purchase the kit separately.
8964C
29a
29b
28
17
31*
30*
22 13
23
25
27
26
11
15
14
24*
2
33
8
74
1a*
1b*
30*
12*
38
{6
9*
10
5
21
**20
**19
64
57
53
18**
4
7
60
60
59
56
52
56
62
61
63
58
66
67
{54
16*
17 308883L
Parts List
Model No. 239877, Series D, pail length
Model No. 239887, Series D,120-pound drum length
Model No. 239888, Series D, 400-pound drum length
Air Motor
Ref.
No. Part No. Description Qty.
Pump
Ref.
No. Part No. Description Qty.
1* 236079 .VALVE, poppet
(includes items 1a and 1b) 2
1a 160896 .STEM, valve 1
1b 170708 .POPPET, valve; urethane 1
2 15K534 .PISTON, air motor 1
4 116343 .SCREW, grounding 1
5 241826 .BASE 1
6{ 114179 .SEAL, throat; polyurethane 1
7 162718 .ADAPTER; 3/8 npt(m) x 1/4 npt(f) 1
8 192541 .ROD, displacement 1
9* 160625 .O-RING, buna-N 1
10 160624 .O-RING, buna-N 1
11 203965 .ROD, trip 1
12* 158367 .GROMMET, rubber, air intake 2
13 172867 .ACTUATOR, valve 1
14 172866 .CLIP, spring 2
15 102975 .SCREW, rd hd mach;
no. 632 x 0.25 in. (6.3 mm) 2
16* 170709 .POPPET, valve; urethane 2
17 160613 .CYLINDER, air motor 1
18** 234577 .PLATE, identification; with muffler 1
19** 100078 .SCREW , hex head;
no. 832 x 0.38 in. (10 mm) long. 12
20** 234578 .PLATE, warning; with muffler 1
21 101578 .SCREW, hex head;
no. 832 x 0.38 in. (10 mm) long 6
22 158360 .YOKE, rod, trip 1
23 158362 .PIN, toggle 2
24* 160621 .O-RING, nitrile rubber 1
25 160623 .ARM, toggle 2
26 158364 .ROCKER, toggle 2
27 167585 .SPRING, helical compression 2
28 156698 .O-RING; buna-N 1
29a 164704 .HANDLE NUT, cylinder, cap
Model 239877 1
29b 161435 .NUT, cylinder, cap
Models 239887 and 239888 1
30* 160261 .NUT, adjusting 4
31* 160618 .LOCKWIRE, transfer valve 2
33 160932 .GASKET; copper 1
38 192537 .NUT, packing 1
* The replacements for these parts are available in
Air Motor Repair Kit 206728. Purchase the kit separately.
** The replacements for these parts are available in
Muffler Repair Kit 222559. Purchase the kit separately.
52 196184 PISTON 1
53 196185 RETAINER, piston seal 1
54{ 114171 SEAL, piston; blue fluorotrel 1
56{ 100065 BALL 2
57 192685 ROD, extension
Model 239877 1
192684 ROD, extension
Model 239887 1
192535 ROD, extension
Model 239888 1
58 192540 ROD, shovel 1
59 192538 CYLINDER, pump 1
60{ 192533 SEAL, gasket 2
61{ 192534 BEARING, shovel rod 1
62{ 114178 SEAL, shovel rod; polyurethane 1
63 192531 CONNECTOR, tube 1
64 192682 TUBE, extension
Model 239877 1
193760 TUBE, extension
Model 239887 1
193758 TUBE, extension
Model 239888 1
66 192660 SHOVEL 1
67 192539 TUBE, shovel 1
74 112154 PIN, spring, straight 1
{ The replacements for these parts are available in
Pump Repair Kit 241623. Purchase the kit separately.
Note: two accessory tools are required for air motor and
throat service: Padded Pliers, 207579 and Gauge, 171818.
18 308883L
Dimensional Drawings
Model 239888
400 lb drum size
Model 239887
120 lb drum size
Model 239877
pail length
Overall length:
45.4 in. (1153 mm)
Overall length:
38.4 in. (975 mm)
Overall length:
31 in. (788 mm)
33.6 in.
(853 mm)
26.7 in.
(678 mm)
17.5 in.
(445 mm)
grounding screw
1/4 npt(f)
fluid outlet
grounding screw
grounding screw
1/4 npt(f)
fluid outlet
1/4 npt(f)
fluid outlet
3/8 npt(f)
air inlet
3/8 npt(f)
air inlet
3/8 npt(f)
air inlet
9039B
Mounting Hole Layout
161023 gasket
two or four
0.265 in. (7 mm)
dia. holes on 5 in.
(127 mm) bolt circle
3 in. (76.2 mm) dia.
04127
2-Hole Mounting
Pattern
4-Hole Mounting
Pattern
19 308883L
Technical Data
Maximum working pressure 8400 (58 MPa, 580 bar) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluid pressure ratio 50:1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Air operating range 30 to 140 psi (0.3 to 0.97 MPa, 3 to 9.7 bar) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Air consumption 22.8 cfm (0.638 m#/min) at 0.25 gpm (0.95 liter/min), . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
at 100 psi (0.7 MPa, 7 bar)
Gallons (liters) per pump cycle 0.003 (0.0109) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum recommended pump speed 76 cycles/min at 0.22 gpm (0.82 liter/min) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wetted parts steel, brass, aluminum, acetal, nitrile rubber, polyurethane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sound pressure level (measured at 1 meter from unit) 77.8 dB(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sound power level (tested in accordance with ISO 96142) 85.6 dB(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Approximate weight 22 lb (10 Kg) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LoctiteR is a registered trademark of the Loctite Corp.
20 308883L
Graco Standard Warranty
Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on
the date of sale to the original purchaser for use . With the exception of any special, extended, or limited warranty published by Graco,
Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be
defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Gracos written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by
faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub-
stitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of
Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture,
installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for
verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The
equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect
in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and
transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT
NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Gracos sole obligation and buyers sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other
remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any
other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the
date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection
with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured
by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide
purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment
hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract,
breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings
entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais-
sent avoir convenu que la rdaction du prsente document sera en Anglais, ainsi que tous documents, avis et procdures judiciaires
excuts, donns ou intents la suite de ou en rapport, directement ou indirectement, avec les procedures concernes.
Graco Phone Numbers
TO PLACE AN ORDER, contact your Graco distributor, or call one of the following numbers
to identify the distributor closest to you:
18005339655 Toll Free
6126236928
6123783590 Fax
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.