Specification sheet
ABB Instrumentation
50T Series Transmitters
Model 53G/A gauge/absolute
flush diaphragm pressure transmitter
Ranges : - 100 to 60000 kPa
- 1 to 600 bar
- 14.5 to 9000 psi
Base accuracy : 0.2% (BFSL)
Piezoresistive thick film technology
Wide choice of process connection
- optimum flexibility to meet plant
requirements
Wide choice of ranges
Good overpressure performance without
calibration change
Local zero adjustment
- allows easy on site calibration
- conformity
50T Series transmitters
Reliable sensors for pressure
measurements
53G/A PRESSURE TRANSMITTER SPECIFICATIONS
An all stainless steel construction with flush diaphragm connection makes these transmitters ideally suited for measurements on viscous
and heavy fluids such as paint, pulp and paper, and most uses in the refrigeration field. Those transmitters are based on a ceramic
sensing element.
FUNCTIONAL SPECIFICATIONS
Service :
Viscous and heavy fluids applications
(1)
G 1 A connection only
(2)
G 3/4 A and G 1 A connections only
-100 to 60 / -1 to 0.6
(1)
-100 to 150 / -1 to 1.5
(2)
-100 to 300 / -1 to 3
-100 to 500 / -1 to 5
-100 to 900 / -1 to 9
-100 to 1500 / -1 to 15
-100 to 2400 / -1 to 24
-100 to 3900 / -1 to 39
0 to 160 / 0 to 1.6
(1)
0 to 250 / 0 to 2.5
(2)
0 to 400 / 0 to 4
0 to 600 / 0 to 6
0 to 1000 / 0 to 10
0 to 1600 / 0 to 16
0 to 2500 / 0 to 25
0 to 4000 / 0 to 40
0 to 6000 / 0 to 60
0 to 10000 / 0 to 100
0 to 16000 / 0 to 160
0 to 25000 / 0 to 250
0 to 40000 / 0 to 400
0 to 60000 / 0 to 600
0 to 160 / 0 to 1.6
(1)
0 to 250 / 0 to 2.5
(2)
0 to 400 / 0 to 4
0 to 600 / 0 to 6
0 to 1000 / 0 to 10
0 to 1600 / 0 to 16
0 to 2500 / 0 to 25
0 to 4000 / 0 to 40
0 to 6000 / 0 to 60
0 to 10000 / 0 to 100
0 to 16000 / 0 to 160
0 to 25000 / 0 to 250
0 to 40000 / 0 to 400
0 to 60000 / 0 to 600
METRIC RANGES
Gauge ranges
(kPa / bar)
Compound ranges
(kPa / bar)
Absolute ranges
(kPa / bar)
IMPERIAL RANGES
Gauge ranges
(psi)
Compound ranges
(psi)
Absolute ranges
(psi)
Overpressure
MPa bar
Burst pressure
MPa bar
0.3
0.5
0.8
1.2
2
3.2
5
8
12
20
32
50
60
80
3
5
8
12
20
32
50
80
120
200
320
500
600
800
0.6
0.7
1.2
1.8
3
4.8
7.5
12
18
30
48
60
80
100
6
7
12
18
30
48
75
120
180
300
480
600
800
1000
Overpressure
(psi)
Burst pressure
(psi)
72.5
72.5
116
174
290
464
725
725
1160
1740
2900
4640
4640
7250
8700
11600
100
100
174
261
435
696
1087
1087
1740
2610
4350
6960
6960
8700
11600
14500
-14.5 to 15
(1)
-14.5 to 30
(2)
-14.5 to 60
-14.5 to 100
-14.5 to 200
-14.5 to 300
0 to 30
(1)
0 to 40
(2)
0 to 60
0 to 100
0 to 150
0 to 200
0 to 300
0 to 400
0 to 600
0 to 1000
0 to 1500
0 to 2000
0 to 3000
0 to 4000
0 to 6000
0 to 9000
0 to 30
(1)
0 to 40
(2)
0 to 60
0 to 100
0 to 150
0 to 200
0 to 300
0 to 400
0 to 600
0 to 1000
0 to 1500
0 to 2000
0 to 3000
0 to 4000
0 to 6000
0 to 9000
Supply voltage - 12
0.02
Fatigue life :
greater than 10 million cycles
(pressure reversal, 20 to 80% of range; f = 1 Hz)
Optional surge protection :
Meets CEI 10000-4-5
Insulation resistance :
> 100 M @ 250 Vdc
Output signal :
4 to 20 mA dc
PERFORMANCE SPECIFICATIONS
Unless otherwise specified, errors are quoted as % of full scale
Accuracy
Accuracy rating (*) :
0.2% of BFSL
(*) including combined effects of linearity, hysteresis and repeatability
Operating influences
Ambient temperature per C (1.8F) change beteween the limits
of -10C to +70C (+14 to +160F)
Zero error :
0.015%
Span error :
0.01%
EMI/RFI :
Meets EN50081 for emission and EN50082 for immunity
Stability :
< 0.20% over a twelve-month period
Vibrations effect (meets IEC 68-2-6) :
Total effect : 0.1% from 10 to 2000 Hz and acceleration up to
200 m/s
2
(20g) in any axis.
PHYSICAL SPECIFICATIONS
Materials
Process wetted parts :
O'ring 1 or 2: Nitril (NBR), Neoprene (CR) or Viton (FKM)
Flush Diaphragm: AISI 316L (1.4404) stainless steel
Housing :
AISI 304 / 1.4301 stainless steel
Tagging :
Aluminium data plate sticked to the housing
Filling oil : LRS1
Environmental protection
The transmitter is dust and sand tight.
Enclosure class :
IP 65 (with 4 pin DIN 43650 connector)
IP 67 with cable outlet
Hazardous atmospheres :
Intrinsically safe version,
EEx ia IIC T5 (Tamb -25 to +70C)/ T6 (Tamb -25 to +40C)
Process connections with flush diaphragm
G 1/2 A (1 o'ring)
G 1/2 A (2 o'rings)
G 3/4 A (1 o'ring)
G 3/4 A (2 o'rings)
G 1 A (1 o'ring)
G 1 A (2 o'rings)
1/2 NPT
Electrical connections
4-pin connector ISO4400/DIN 43650
1/2" NPT-m conduit + 1.5 m cable
Cable gland (PG 9) + 1.5 m cable
Mass
4-pin connector ISO 4400/DIN 43650: 0.230 kg
1/2" NPT-m conduit connection: 0.340 kg
PVC Cable (1.5 m) + cable gland (PG 9): 0.285 kg
Packing
Carton 13.5 x 6 x 3.5 cm approx. (5.5 x 2.5 x 1.5 in): G1/2 and 1/2 NPT
or 18.5 x 8.5 x 7 cm approx. (7.5 x 3.5 x 3 in): others
Zero adjustment :
15% of full scale
Temperature limits :
Ambient -25 and +85C (-13 and +185F)
(can be limited by intrinsically safe
application)
Process -25 and +100C (-13 and +210F)
for ambient +50C ( +120F)
Compensated : -10 and +70C (+14 and +160F)
Response time :
3 ms
Power supply :
The transmitter operates from 12 up to 40Vdc and is protected
against reverse polarity connection. (see drawing below for
load limitation).
For intrinsically safe application power supply must not exceed
28 Vdc.
Load limitations - total loop resistance :
Power supply (Vdc)
T
o
t
a
l
l
o
o
p
r
e
s
i
s
t
a
n
c
e
600
(ohms)
1400
800
12 40 (volt) 24
O
p
e
r
a
t
i
n
g
a
r
e
a
R()=
(volts)
ELECTRICAL CONNECTIONS
MOUNTING DIMENSIONS
ISO 4400 / DIN 43650 Connector : Cable outlet :
Option
4-20 mA
1 + supply
2 - supply
3 NC
ground
3
2 1
(-) (+)
Pressure connections
1
0
1
(
w
it
h
1
/
2
"
N
P
T
p
r
o
c
e
s
s
c
o
n
n
e
c
t
io
n
)
Cable 6
0.230 kg
0.507 lb
0.285 kg
0.628 lb
0.340 kg
0.750 lb
6 to 8
Zero adjustment
G1/2"A
16.1
G1/2"A
16.1
79
93
20
1 o'ring (NBR) mounting
G 1/2 A
G 3/4 A G 1 A
o'ring o'ring o'ring
Specific female threads
1/2" NPT
2 o'rings (NBR) mounting
G 1/2 A
G 3/4 A G 1 A
o'ring o'ring o'ring
o'ring o'ring o'ring
Specific female threads
20.1 16.6 20.1 16.1 19.6 19.6
20 20.5
20
16.6
Screen (ground)
White (+)
Blue (-)
Supply voltage /
mA output signal
G 1/2" A / 1 o'ring 3
G 1/2" A / 2 o'rings A
G 3/4" A / 1 o'ring B
G 3/4" A / 2 o'rings C
G 1" A / 1 o'ring D
G 1" A / 2 o'rings E
1/2" NPT 5
Fixed range gauge pressure transmitter 53G
Fixed range absolute pressure transmitter 53A
- 100 to 60 kPa
(1)
K12 - 1 to 0.6 bar
(1)
B12 - 14.5 to 15 psi
(1)
E12
- 100 to 150 kPa
(2)
K13 - 1 to 1.5 bar
(2)
B13 - 14.5 to 30 psi
(2)
E13
- 100 to 300 kPa K14 - 1 to 3 bar B14 - 14.5 to 60 psi E14
- 100 to 500 kPa K15 - 1 to 5 bar B15 - 14.5 to 100 psi E15
- 100 to 900 kPa K16 - 1 to 9 bar B16 - 14.5 to 200 psi E16
- 100 to 1500 kPa K17 - 1 to 15 bar B17 - 14.5 to 300 psi E17
- 100 to 2400 kPa K18 - 1 to 24 bar B18 0 to 30 psi
(1)
E23
- 100 to 3900 kPa K19 - 1 to 39 bar B19 0 to 40 psi
(2)
E24
0 to 160 kPa
(1)
K25 0 to 1.6 bar
(1)
B25 0 to 60 psi E25
0 to 250 kPa
(2)
K26 0 to 2.5 bar
(2)
B26 0 to 100 psi E26
0 to 400 kPa K27 0 to 4 bar B27 0 to 150 psi E27
0 to 600 kPa K28 0 to 6 bar B28 0 to 200 psi E28
0 to 1000 kPa K29 0 to 10 bar B29 0 to 300 psi E29
0 to 1600 kPa K31 0 to 16 bar B31 0 to 400 psi E31
0 to 2500 kPa K32 0 to 25 bar B32 0 to 600 psi E32
0 to 4000 kPa K33 0 to 40 bar B33 0 to 1000 psi E33
0 to 6000 kPa K34 0 to 60 bar B34 0 to 1500 psi E34
0 to 10000 kPa K35 0 to 100 bar B35 0 to 2000 psi E35
0 to 16000 kPa K36 0 to 160 bar B36 0 to 3000 psi E36
0 to 25000 kPa K37 0 to 250 bar B37 0 to 4000 psi E37
0 to 40000 kPa K38 0 to 400bar B38 0 to 6000 psi E38
0 to 60000 kPa K39 0 to 600 bar B39 0 to 9000 psi E39
ORDERING CODE
53
A (Absolute pressure)
G (Gauge pressure)
MEASURING RANGE & UNITS
PRESSURE CONNECTION
GASKETS
OUTPUT SIGNAL
Select one set of characters from each category and specify complete catalog number
Code
BASE MODEL
MEASURING RANGE & UNITS
CODE
CALIBRATION CERTIFICATE
SURGE PROTECTION
ELECTRICAL CONNECTION
ELECTRICAL CERTIFICATION
def
abc
def g h i j k l m n
Code Code Code
(1)
Not available with G1/2" A - G3/4" A - 1/2"NPT connections (versions 3-A-B-C-5 on 'g' position)
(2)
Not available with G1/2" A - 1/2" NPT connections (versions 3-A-5 on 'g' position)
NBR (Nitril) B
CR (Neoprene) Note C
FKM (Viton) V
GASKETS
4 - 20 mA 3
OUTPUT SIGNAL
Cable gland + 1.5 meter cable 2
1/2" NPT conduit 3
4-pole connector ISO 4400/DIN 43650 4
ELECTRICAL CONNECTION
General purpose 1
Intrinsic Safety (pending) 2
ELECTRICAL CERTIFICATION
None 1
Yes 2
SURGE PROTECTION
Not required 1
Yes 2
CALIBRATION CERTIFICATE
h
i
j
k
l
m
PRESSURE CONNECTION
g
Note : Not available for ranges 40000 kPa (400 bar)
Code 2 n
ABB Instrumentation spa
Via Statale 113
22016 Lenno (Como)
Italia
Tel. 0344 58111
Facsimile 0344 56278
ABB Automation Inc.
125 East County Line Road
Warminster, Pa.
18974-4995 USA
Tel. (215) 674-6693/6320/6777
Facsimile (215) 674-7184
ABB Instrumentation Ltd.
Howard Road
St. Neots, Cambs.
England PE19 3EU
Tel. (01480) 475321,
Facsimile (01480) 217948
The Company's policy is one of continuous product
improvement and the right is reserved to modify the
specifications contained herein without notice.
S
S
/
5
3
G
A
R
e
v
1