1:2 Redundant System Controller Drawing Index This section contains drawings peculiar to your system as it was shipped from the factory.

Uploaded by

cuonglom
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (1 vote)
841 views7 pages

RSC1200 1005 s8 PDF

1:2 Redundant System Controller Drawing Index This section contains drawings peculiar to your system as it was shipped from the factory.

Uploaded by

cuonglom
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

DMAN-14576 Rev.

8.2

1:2 Redundant System Controller

Drawing Index
This section contains drawings peculiar to your system as it
was shipped from the factory.

Table 8-1

Drawing Index

Drawing Number

Description

RSC1200.1005

Bill of Materials (BOM), RSC-1200 w/ Serial I/O, Slides

TD13040

Test Data Sheet, RSC-1200

13074

Specification, RSC-1200

20453

Material Disclosure Table, RSC1200.1005

System Configuration 8-3

DMAN-14576 Rev. D

8-4 System Configuration

1:2 Redundant System Controller

PARENT ITEM:
DESCRIPTION:

RSC1200.1005
RSC-1200 W/ SERIAL I/O, SLIDES

REV:

ECO:

RUN DATE: 5/22/2012

SINGLE-LEVEL BILL OF MATERIALS

ECR 11332

QTY UoM

COMPONENT DESCRIPTION

BSQ

COMPONENT ITEM

MANUFACTURER

MFR PART #

DPRO-11577

VERTEXRSI

DPRO-11577

EA

TEST PROCEDURE, CONTROLLER

DPRO-20601

VERTEXRSI

DPRO-20601

EA

Procedure, Current Calibration RSC-series Controllers

DMTD-13040

VERTEXRSI

DMTD-13040

EA

TEST DATA, RSC-1200

DMAN-14576

VERTEXRSI

DMAN-14576

EA

O&M MANUAL, RSC-1200 W/ SERIAL I/O

ARLC-9683-2002

VERTEXRSI

ARLC-9683-2002

EA

ASSY, LR-1200 CONTROLLER, AC W/ CHASSIS


SLIDES

IFLS-11617V22

VERTEXRSI

IFLS-11617V22

EA

FIRMWARE, REDUNDANT RSC CONTROLLER,


VERSION 2.2x

MLFW-11617V22

VERTEXRSI

MLFW-11617V22

EA

LABEL, FIRMWARE, REDUNDANT RSC


CONTROLLER, VERSION 2.2x

DMDT-20453

VERTEXRSI

DMDT-20453

EA

China MDT, RSC1200.1005

MLAB-20359-15

VERTEXRSI

MLAB-20359-15

EA

LABEL, EFUP, 15 YEARS

REFERENCE

PAGE 1 OF 1

Measured Test Data


Para.* Check/Adjust
1.1
120V Line IRMS @ J1
1.2
120V Line IRMS @ J2

Desired Results
700 mA maximum

Data
mA

700 mA maximum

mA

2.1
3.1
3.2
4.2
4.3
4.4

Configure fuse settings per


customer requirement
PS1 verification
PS2 verification
Unit 1 nom. current
Unit 2 nom. current
Unit 3 nom. current

1 fuse, std. (North America)


2 fuses, opt. (Europe)
+15.0 0.1 Vdc @ TP1
+15.0 0.1 Vdc @ TP1
Set
Set
Set

5.1
5.2
6.1
6.3
6.3
6.4
6.4

Switching assembly S1
Switching assembly S2
LED and beeper test
Unit 1 POL1 select
Unit 3 POL1 select
Unit 2 POL2 select
Unit 3 POL2 select

Function OK
Function OK
All LEDs lit; beeper sounds
Function OK
Function OK
Function OK
Function OK

mA
mA
mA

Reference only. Test fixture LNA.

* Refer to Test Procedure DPRO-11577.

Model Number
Serial Number
Customer P/N
Revision
Test Technician
Date
Approved By

RSC-1200

TD13040

8/25/00

1:2 Redundant System Controller


RSC-1200
Introduction

Control Panel Features

Redundant systems increase system availability by


including spares for critical units (e.g., LNAs, LNBs, BUCs
or SSPAs) in the signal path. In the case of a detected unit
failure, the redundant system automatically switches to the
spare. A 1:2 redundant system supports two active units
and one spare unit.

The RSC-1200 Redundant System Controller can directly


power most LNA or LNB units and monitor the output
voltages and currents to detect faults. The controller can
also monitor external alarm input signals, such as from a
SSPA or BUC, or monitor a combination of output currents
and external alarm inputs. Upon detecting a unit failure,
the controller can automatically drive a waveguide switch
to activate the spare unit.

Standard 19" rack panel, 3" high


Dual, redundant power supplies
Worldwide universal AC input capability
Manual or automatic operation
Mimic front panel graphically depicts switch positions
and unit status
Monitors unit currents, external alarms, or a
combination of both to detect unit failure
Automatically switches RF path to standby unit when
unit failure occurs
Jumperless RS-232/-422/-485 and parallel I/O M&C
interfaces
Audible alarm
Jumperless software configuration of all options
Remote Control Panel option duplicates front panel at
remote site

Part Number/Ordering Information


Consult factory for DC power option, longer control cables,
and custom configurations.

1:2 Redundant System Controller

RSC-1200

Order control cable separately.

Front Panel Controls and Indicators


FAULTS
1:2 REDUNDANT
SYSTEM CONTROLLER

CONTROLLER
PS 1

INPUTS

POL 1

OUTPUTS

UNIT 1

CAL

UNIT 3

POL 1

CAL

POL 2

CONTROLS
LOCAL
REMOTE
REMOTE PANEL LOCKOUT

PS 2

RSC-1200

RCP

POL 2

FAULT
RESET
PANEL
TEST

UNIT 2

CAL

OFFLINE

AUTO
MANUAL
SHIFT

OFFLINE

INC

FUNCTION
A BCD E FGH I J
SETTING
9876543210

DEC

Unit Status Alarms

LED Indicators glow green when OK, red when a fault is detected.

PS1, PS2 Indicators

Glow red to show fault with dual redundant power supplies.

Panel Test Pushbutton

Lights all indicators & tests audible alarm.

Unit Pushbuttons and Indicators

Pushbuttons are used to manually switch units. Arrow indicators show which
units are on-line. Unit indicators light red to show faulted units. Unit 1 is the
primary unit for Pol 1 and Unit 2 is the primary unit for Pol 2. Unit 3 is on
standby and can be selected for either Pol.

Auto/Manual Switch and Indicators

In Auto mode, a unit failure initiates automatic switchover to the standby unit.
In manual mode, the on-line unit can be selected from the front panel or by
serial I/O or parallel I/O command.

Remote/Local Switch and Indicators

Selects local (front panel) control, or remote control from serial I/O, parallel
I/O, or optional remote panel.

Rear Panel I/O Interface


LINE 87-265 V

47-63 Hz

J3
PLATE ASSY

J1

For continued protection against fire,


replace only with same type and rating
of fuse.
Refer servicing to qualified personnel.

PN
CPN
SN
MADE IN U.S.A.

J4
EXT ALM

J5
RCP LINK

J6
LOOP

J7
SERIAL I/O

J8 PARALLEL I/O

J2
Consult operation and maintenance

! manual for correct fuse rating.

LINE 1 - J1, LINE 2 - J2

PLATE ASSEMBLY - J3

EXT ALM - J4

RCP Link - J5
LOOP & SERIAL I/O - J6 & J7

Parallel I/O - J8

Dual power entry modules contain the AC line input connector, fuses, and power switches.
System can be powered from separate AC lines if desired. Either or both power supplies are
capable of operating the system.
Cable to antenna plate assembly carries unit power (for line drivers, LNAs or LNBs) and switch
drive signals. Order cable separately. Standard lengths are from 100 (30 m) to 250 (75 m) in
50 (15 m) increments; other lengths are special order.
External Alarm inputs. Substitute for or combine with internal unit current monitor alarms.
Allows an external signal to indicate unit failure. Unused inputs can be used as status inputs to
M&C system.
For optional Remote Control panel, which duplicates all front panel functions. Interconnect
cable lengths to 4000 ft (1200 m).
RS-232/RS-422/RS-485 connectors for user M&C System. Commands provide monitoring,
controlling, and configuration. Interconnect cable lengths to 4000 ft (1200 m) with RS-422 or
RS-485.
Parallel I/O connection for customer control or monitoring. Capable of controlling all features
of the system except remote/local switch.
Form C relay contact outputs (1:1 systems):
Unit 1 status
PS1 status
Pol 1: Unit 1 or Unit 3
Unit 2 status
PS2 status
Pol 2: Unit 2 or Unit 3
Unit 3 status
Local/Remote mode
Auto/Manual mode
Control inputscontact closure to ground (1:1 systems):
Pol 1 Unit 1 select
Pol 2 Unit 2 select
Auto/Manual select
Pol 1 Unit 3 select
Pol 2 Unit 3 select

Controller Specifications
LNA Status Monitor Method

Current Window Width


Switchover Time
Unit Power Outputs
External Alarm Inputs
Serial I/O:
Interface
Connector
Parallel I/O:
Status outputs
Control inputs
Connector
Controller Dimensions
Chassis Slides
Cable Length to Plate Assy
AC Input
Operating Temperature Range

Controller monitors unit bias current; alarm is generated if current goes outside of allowed
tolerance window (LDA or LNA/LNB systems). Controller also monitors external alarm inputs
or combinations of both internal unit current and external alarm inputs.
5% to 25% of nominal; software selectable in 5% steps
100 ms
15 Vdc; 50 to 600 mA
One per unit; require sinking 5 mA at 5 Vdc to negate alarm
RS-232/RS-422/RS-485 2- or 4-wire; jumperless selection
9-Pin D, female
Form C dry contacts; 100 Vdc, 0.5 A, 3 W max (resistive load)
Contact closures to ground; require sinking 20 mA at 15 Vdc
37-pin D, male
19" (483 mm) W x 3.47" (88.1 mm) H x 17.5" (445 mm) D; 25 lb (11.4 kg)
Standard
Order cable separately. 100 ft (30 m) to 250 ft (75 m) lengths in 50 ft (15 m) increments are
standard; other lengths are available by special order.
87-265 Vac, 4763 Hz, 100 W. Dual AC inputs and dual redundant power supplies.
DC input (48 V) is available as an option; consult factory.
0 to +50 C

60 Decibel Road, Suite 200 State College, PA 16801 USA Tel. 814 238 2700 FAX 814 238 6589
Web Site: www.gdsatcom.com/electronics.php

13074

General Dynamics. All rights reserved. General Dynamics reserves the right to make changes to its products and specifications at any time and without notice.
All trademarks indicated as such herein are trademarks of General Dynamics. All other product and service names are the property of their respective owners.

Rev. A

ECR 7564

2/21/07

MSI

Hazardous Substances or Elements

RSC1200.1005

Component Name

ACAB-14835-1 & -2
APCB-13310-1
APCB-9317-1
APCB-9339-2
Littelfuse 313003, 0213002
MCOV-4058
MCOV-9799
MENC-14834
MMIS-12676
MPAN-9685/9688
TPAN-9860-1

Description

Cable Assy, Power Entry ,


Assy, Printed Circuit Board
Assy, Printed Circuit Board
Assy, Printed Circuit Board
Fuses
Cover
Cover Plate
Enclosure ()
Hold Down ( )
Rear Panel
Assy, Front Panel

Lead
(Pb)

Mercury
(Hg)

X
X
X
X
X
O
O
O
O
O
X

O
O
O
O
O
O
O
O
O
O
O

PolyChromium VI
brominated
Cadmium Compounds
Biphenyls
(Cd)

(Cr6+)
(PBB)
O
O
O
O
O
O
O
O
O
O
O

O
O
O
O
O
X
X
X
X
X
X

O
O
O
O
O
O
O
O
O
O
O

Polybrominated
Diphenyl
Ethers

(PBDE)
O
O
O
O
O
O
O
O
O
O
O

O: Indicates that this toxic or hazardous substance contained in the homogeneous materials for this part, according to EIP-A, EIP-B, EIP-C is below the limit requirement in
SJ/T11363-2006 -- EIP-A. EIP-B. EIP-C SJ/T11363-2006
X: Indicates that this toxic or hazardous substance contained in the homogeneous materials for this part, according to EIP-A, EIP-B, EIP-C is above the limit requirement in
SJ/T11363-2006 -- EIP-A. EIP-B. EIP-C SJ/T11363-2006

20453 Rev.
As Issued 4/18/07 MSI

You might also like