Alcatel-Lucent 1830 Photonic Service Switch-1
Alcatel-Lucent 1830 Photonic Service Switch-4 |
RELEASE 3.6
The Alcatel-Lucent 1830 Photonic Service Switch (PSS)-1 and Alcatel-Lucent 1830 PSS-4
represent a new type of photonic-switching access platform for metro wavelength division
multiplexing (WDM). Implementing Zero-Touch Photonics, they transform traditional WDM
into a cost-effective, low-footprint and fully flexible transport layer with complete visibility
and control of individual wavelengths. This transformation simplifies broadband service
delivery, speeds time-to-revenue generation and facilitates bandwidth expansion in optical
transport network (OTN)-based metro access networks. The 1830 PSS-1/PSS-4 are key
members of the 1830 PSS portfolio serving applications that span access, metro/regional,
and long-haul networks.
The Alcatel-Lucent 1830 PSS-1 is a compact, one rack unit (RU) customer premises
equipment (CPE), hardened for outdoor deployment and available in different fixed
configurations. The Alcatel-Lucent 1830 PSS-4 has a two RU chassis with four slots available
for service cards, the same cards supported by the Alcatel-Lucent 1830 PSS-16 and the
Alcatel-Lucent PSS-32 (see Figure 1).
Applications
Key benefits
The Alcatel-Lucent 1830 PSS-1/PSS4 supports the transport and
delivery of multiple services in a
variety of environments:
Extension of the Alcatel-Lucent
1830 PSS product family to the
customer premises
Cost-effective, small footprint
and low power consumption
Deployment flexibility: compact
and temperature-hardened for
outdoor installation
Transport networks for service
providers to aggregate
SONET/SDH, IP/MPLS, Mobile,
Broadband (xDSL, PON) traffic
Metro network extension to the
customer premises through costeffective CWDM/DWDM
technology up to 10G
A variety of client interfaces
with high port density to
maximize wavelength efficiency
Campus networks for data
center protection or data sharing
for organizations such as
universities, hospitals, banks and
airports
Support for cost-effective
multiplexing of any bit-rate
services and transport over
optical transport unit (OTU)1/OTU-2
Multi-campus networks for
cooperation among public and
private companies and
optimization of leased dark fiber
Metropolitan or national
research networks that can be
combined with the Alcatel-Lucent
1830 PSS-16/PSS-32 to extend
these networks to regional
distances
Optical Data Unit (ODU)k
switching capability
Terminal, Fixed Optical Add
Drop Multiplexer (FOADM) or InLine Amplifier (ILA) applications
Strong forward error correction
(FEC) technology based upon OTN
to improve system performance
and optical link budgets
Simplified network design,
implementation and maintenance
with auto power management
and Wavelength Tracker
Figure 1. Alcatel-Lucent 1830 PSS1/PSS-4 for metro WDM
1830
PSS-32
1830
1830 PSS-16
DWDM
PSS-32
regional/core
1830 PSS-16
1830PSS
-4
1830PSS
-1
C/DWDM
1830PSS1
metro
access
1830PSS-4
Common features
Optical-layer intelligence
services
G.709-compliant
Flexible service-level alarms
Ring, bus and point-to-point
network topologies support
Carrier-class availability
Single-fiber bidirectional line
transmission (CWDM)
Scalability
Pluggable client interfaces
enable turning up interfaces
based on traffic demand
In-service network scalability
without service disruption
99.999 percent availability
CE, CSA, NEBS Level 1 and
VCCI compliant
Redundant power supply
Temperature-hardened
operation
Storage area networks (SAN)
Network management
Integrated SLA support
and monitoring
Proactive service
management for wavelength
Brocade certification
Flexible protection options
Diverse route protection
E-SNCP within 50 ms
Full-featured Operations,
Administration, Maintenance &
Provisioning (OAM&P)
functionality
Alcatel-Lucent 1350 Optical
Management System (OMS)
Alcatel-Lucent 1340
Integrated Network Controller
(INC)
Alcatel-Lucent 1354 Photonic
Manager (RM-PhM)
Alcatel-Lucent 5620 Service
Aware Manager (SAM)
Interfaces: Web graphical
user interface (GUI) and
command-line interface (CLI)
Transaction Language 1 (TL1)
Simple Network Management
Protocol (SNMP)
Ethernet port for local access
Integrated remote
management through General
Communication Channel (GCC)
and Optical Supervisory
Channel (OSC)
Selectable rates for OSC: 100
Mb/s or 155 Mb/s
Auto node discovery
Alcatel-Lucent Advanced
Engineering Planning Tool
simplifies network design and
system installation
1830 PSS-1 models
Alcatel-Lucent 1830 PSS-1/1830 PSS-4 | Data Sheet
Page 2 of 7
1830 PSS-1 MSAH
Client ports: 21 x E1 (75
Ohm) plus 4 independent
anyrate ports :
- SONET : OC-3, OC-12 and OC48
- SDH: STM-1, STM-4 and STM16
- Fast Ethernet (FE), Gigabit
Ethernet (GE)
- 1G Fiber Channel (FC), 2G FC
and 4G FC
- 1G Fiber Connectivity (FICON)
and 2G FICON
- High-definition-serial digital
interface (HD-SDI)
- Standard definition (SD)-SDI
Line ports: 2 x OTU-1/STM-1
Standard SDH/SONET
mapping
- E1, VC12, TUG2 , TUG3, VC4,
AU4
- STM-16 and OC-48 to ODU1
- Standard GE to ODU0
- Alternative proprietary
mapping option for more
efficient sub-ODU1 client
grooming
1830 PSS-1 AHP
High-power, high-gain C-band
optical amplifier with 20-dBm
output and variable gain setting
from 13 to 33 dB
Auto power mode: amplifier
gain is adjusted automatically
and dynamically
Manual power mode
Client ports: 12 x GE
(SFP)
Line ports: 2 x 10GE or 2
x OTU-2 (XFP)
Integrated Layer 2
switching capability
Supports full-rate and
sub-rate Ethernet Virtual
Private Line (EVPL) service
with E-SNCP protection
Two stacked units serve as an
ILA
Stacked units can be
managed by a single IP address
E-SNCP protection for
intraboard traffic
OSC for remote management
and auto node discovery
Wavelength Tracker monitors
and traces each wavelength
Committed Information
Rate (CIR)/Excess
Information Rate (EIR)
Quality of Service (QoS)
control based on MEF 6.1
Up to 8 CWDM
wavelengths
Support for sub-rate CIR
Ethernet
Support for provisional
flexible multiplexing (1:2, 1:3
and 1:4) and transparent
transport of any bit-rate
services over OTU-1
Up to 8 CWDM wavelengths
Data communication
network (DCN) access through
LAN port
Alcatel-Lucent 1830 PSS-1/1830 PSS-4 | Data Sheet
1830 PSS-1 MD4H
1830 PSS-1 GBEH
Page 3 of 7
Dual muxponder boards,
each supporting 4 client
ports and 2 line ports
Client ports: 4
independent anyrate ports
- OC-3, OC-12 and OC-48
- STM-1, STM-4 and STM-16
- FE, GE
- 1G FC, 2G FC and 4G FC
- 1G FICON and 2G FICON
- HD-SDI
- SD-SDI
Line ports: 2 x OTU-1
Up to 8 shelves managed
as a single network element;
Extension shelf support
MD4H and MSAH mixture
configuration
Mapping:
- Standard STM-16 and OC48 to ODU1
- Standard GE to ODU0
- Alternative proprietary
mapping option for more
efficient sub-ODU1 client
grooming
Supports provisional
flexible multiplexing (1:2,
1:3 and 1:4) and transparent
transport of any bit-rate
services over OTU-1
Up to 8 CWDM
wavelengths
DCN access through LAN
port
1830 PSS-4 key features
Service cards
11DPE12 Dual
pluggable 12xGbE OT
1830 PSS-4
Full-slot card (fullheight)
2 RU chassis, 4 full-slot
(full-height)
12 x GE (SFP) client
ports
Support for field
replaceable circuit packs
2 x 10GE or 2 x OTU-2
(XFP) line ports
Up to 60G slot capacity
Support for:
- Standard mapping: GE,
AU3, AU4 and ODU0/1/flex
- Alternative proprietary
mapping option for more
efficient sub-ODU1 client
grooming
Backplane add-drop
multiplexer (ADM) and
protection for adjacent
service optical
transponders (OTs)
Statistic Layer 2
multiplexing
Support for full-rate and
sub-rate EVPL service with
E-SNCP protection
Support CIR/EIR
provision range with
500Mbps step for the
10GbE line port (Q-in-Q)
E-SNCP protection for
both intraboard and
interboard traffic
E-SNCP via backplane
cross connection and
protection
10G native LAN for
interworking with 10G
router (both line ports
needs to be 10GE)
- Q-in-Q tagging
- Native 10 GE line
support with FEC ASIC
Flexible SVLAN ID 2 to
4094
VLAN protection based
on CCM/LOSPROP
Line ports: 2 x OTU-1
SVLAN Pop-pushing
Mapping
- Standard STM-16/OC-48
to ODU1
- Standard GE to ODU0
- Alternative proprietary
mapping option for more
efficient sub-ODU1 client
grooming
Support for provisioning
flexible multiplexing (1:2,
1:3 and 1:4) and
transparent transport of
any bit-rate services over
OTU-1
Temperature-hardened
OTN overhead alarm &
PM; Far End PM; Analog PM
enhanced; Pre/Post-FEC
BER monitoring
Full-rate and sub-rate
EVPL: Q-in-Q
FEC type: RS FEC, EFEC,
EFEC2(ALU)
Terminal or OADM/blade
application
VLAN based CIR/EIR QoS
(MEF 6.1)
Protection: E-SNCP in Qin-Q and Y-cable; E-SNCP
protection for two mate
11DPE12E
Single-fiber CWDM
bidirectional line
transmission
(4 services per line)
Temperature-hardened
for outdoor deployment
Supports up to 8 CWDM
or 32 DWDM wavelengths
in ITU-T grid
Support for single-fiber
bidirectional line
transmission (CWDM)
Y-cable protection
CIR/EIR QoS control
based on MEF 6.1
Wavelength Tracker
monitors and traces each
wavelength
Ethernet optical adddrop mulitplexer (OAM):
Y.1731/802.1ag FM/PM
Cross-connection (ADM)
between two mate
11DPE12 via backplane
11QPA4/11QPA4A
11G quad port tunable
AnyRate 4-client OT
Temperature hardened
11DPE12E Dual
pluggable
12xGbE enhanced OT
Full-slot card (Fullheight)
4 independent multirate
10G channels
Alien wavelength
management
Cascaded shelves
managed as single
element
Synchronous Ethernet
support
Optical-layer path
tracing and power
monitoring on a perunique-wavelength service
basis
View of all wavelengths
present on a selected fiber
pair
Integrated fault isolation
and sectionalization at the
optical layer
Automated optical layer
with dynamic power
equalization
Integrated fault
correlation
Supported all of the
11DPE12 features and
additional new features
are as below:
Full-slot card (FullHeight)
12 x GE (SFP) client
ports
2 x 10GE or 2 x OTU-2
(XFP) line ports
Fast Ethernet support for
electrical and optical
Up to 100 E-Line
services per 10G line port
(Q-in-Q)
Support rate provision
(CIR/PIR) in flexible
increments up to full port
rates
Client ports
- 4 independent anyrate
ports
- OC-3, OC-12 and OC-48
- STM-1, STM-4 and STM16
- FE, GE
- 1G, 2G and 4G FC
Up to 32 flows E-SNCP
based on APS_PCC (Q-inQ)
- 1G and 2G FICON
- HD-SDI
- SD-SDI
11DPM12 Dual-port
pluggable Multirate
Mux 12-Client OT
Full-slot card (fullheight)
Client ports:12
independent anyrate ports
- OC-3, OC-12 and OC-48
- STM-1, STM-4 and STM16
- FE, GE
- 1G FC, 2G FC and 4G FC
Temperature-hardened
Client ports
4 x STM-64 and OC-192
- 1G FICON and 2G FICON
Line ports: 2 x OTU-2
Support for both
standard mapping
(ODU0/1/flex) and
proprietary mapping
option for more efficient
sub-ODU1 client grooming
Code-transparent
transport for GE and clocktransparent for GE, STM-1
and STM-4
10 GE wide area
network (WAN)/local area
network(LAN) PHY
OTU-2
8G FC and 10G FC
OTU-1
HD-SDI
SD-SDI
3G-SDI
Line ports: 4 x OTU-2
with provisioning FEC
(XFP)
Operation Mode:
Add/Drop, CrossReg,
Drop_Continue(10GE
signal), Addonly(10GE
signal)
40G embedded ODUk
matrix: client/line/mate
interconnection
Client and line side
protection (E-SNCP)
Protection: E-SNCP and
Y-cable
Drop and continue for
GCC0 support
ODUk SNCP
Y-cable protection for
OC-3/12/48, STM-1/4/16
and GE
1830 PSS-4 key features
- 5Mbps steps from
10Mbps to 100Mbps
- 50Mbps steps from
100Mbps to 1Gbps
10GE service
Each channel
independently supports
unidirectional and
bidirectional operation
mode
Proprietary mapping for
STM-1/OC-3 and STM4/OC-12
ADM on a blade
implementation
- Flexible grooming
- Add/drop of services
around the ring created
with 12 x any Muxponder
cards
Drop and continue
support for GbE and HDSDI,SD-SDI
Interworks with 4DPA4
Muxponder card for:
- STM-1, STM-4 and STM16
- OC-3, OC-12 and OC-48
transparent services
- GE
- 1G FC and 2G FC
- HD-SDI
Pluggable Wavelength
Tracker encoder and slow
eVOA for automatic power
adjustment
Facility and terminal
loopbacks
Digital Performance
Monitoring
- SONET/SDH
- ODU and OTU path and
section
- 8B CV and 10B CV
- GE statistics
- FEC-based PM for OTN
client and line
Temperature hardened
Temperature
hardened(11QPA4A)
Temperature range from
-5C to +55C (11QPA4)
4DPA4 4G dual-port
pluggable AnyRate 4client OT
Half-slot card (halfheight)
Optical amplifier cards
AHPHG
+7 dBm
23dBm
Variable gain from
Input power: -33
13 to 29 dB
dBm to +7.5 dBm
a full-slot card
Output power: 20
dBm
C-band amplifier in a full
Variable gain from
Input power: -24
A2325A
slot card
16 to 32 dB
dBm to +7 dBm
C-band
amplifier
in
Output power: 20dBm
a full-slot card
Variable gain from
AHPLG
Input power: -30 dBm to
16 to 24 dB
Output power:
C-band amplifier in
0
Technical specifications
1830 PSS-1
Small Form Factor Pluggable
(SFP) support
FE: 100BASE-LX10, BX40U/D
GE: 1000BASE-SX/LX/ZX/T,
BX20U/D, BX40U/D
OC-3/STM-1: SS-1.1/ SL-1.1/ SL1.2
OC-12/STM-4: SS-4.1, SL-4.1
OC-48/STM-16: SS-16.1A,
Multirate2.7 Gb/s; SI-16.1, SL16.1, SL-16.2
1G/2G FC/FICON, 4G FC: 4
FCSN-I and 4 FCLC-L
CWDM 2G5 MR PIN: SS-16.2C
CWDM 2G5 MR APD: SL-16.2C
OTU-1: SL-16.1, SL-16.2D
4.55G CWDM: 4 FC-OC
4.55G DWDM: 4 FC-OD
CWDM 2G5 MR PIN: SS-16.2C
CWDM 2G5 MR APD: SL-16.2C
eVOA SFP FAST: fVOA
OSC SFP ultra long haul (ULH):
SUL-1.2O
OSC SFP eULH: SEU-1.2O
10 Gb/s Form Factor
Pluggable (XFP) support
10 GE XI-64.1 and XS-64.2b
10 GE ZR:10GB-ZR
10G CWDM PIN: XS-64.2C
CWDM anyrate up to 11G APD:
XL-64.2C
DWDM anyrate up to 11G: XL64.2D
Physical dimensions
1 RU
- Height: 43.5 mm (1.71 in.)
- Width: 443.9 mm (17.48 in.)
- Depth: 278.5 mm (10.94 in.)
without cover; 288 mm (11.34 in.)
with cover
Wall-mount and rack-mount
kits: 19 in. EIA, 19 in. and 21 in.
ETSI, 23 in. WECO
Maximum power
dissipation
- AHP: 100 W
- GBEH: 101 W
- MD4H: 110 W
- MSAH: 100 W
Typical power
dissipation
- AHP: 75 W
- GBEH: 86 W
- MD4H: 90 W
- MSAH: 83 W
Operating
temperature
- GBEH: -40C to
+65C (-40F to
+149F)
- MD4H/MSAH: -25C
to +65C (-13F to
+149F)
- AHP: -5C to +40C
(23F to 104F); for
short-term operation
-5C to +50C (23F
to 122F)
Humidity:
- CO environment
- 85 percent
long term
- 95 percent
short term
- ETSI
- 95 percent
long term
- Hardened
environment
- 100 percent
long term
Regulatory and
standards
compliance
Telcordia NEBS
Operating environment
Power: -48V DC or 110/220V AC
Level 1, GR63 and
GR1089
FCC Part 15 Class
A
UL Certification:
UL 1950 and UL
60950
CE mark: EN 300
386
IEC Safety: IEC
60950 and IEC
60825-1/2
CSA-22.2-No.25-
M90
ETSI ETS 300
019
- Storage: Hazard
level 1.2
- Transportation:
Hazard level 2.2
- Operational:
Hazard level 3.2
ETSI EN 300
019
- Storage: Class
1.2
- Transportation:
Class T2.3 and
Class 3.2
ETSI EMC
- EN 300 386
v1.3.2
- ETSI ES 201 468
v1.2.1
- EMC directive
89/336 LV
ETS 300 753
ANSI T1.308
RoHS-5
GR-383-CORE
Technical
specification
s
64 : 8
1G FC/FICON : 24
2G FC/FICON : 16
4G FC : 8
8G FC: 8
10G FC: 8
10G GE LAN/WAN
PHY: 8
HD-SDI:16
SD-SDI: 24
3G-SDI: 8
OTU-1: 8
OTU-2: 8
Line interfaces
10 GE: 4
OTU-1: 8
OTU-2: 8
Physical dimensions
2RU
Height: 88 mm (3.46
in.)
Width: 440 mm
(17.32 in.)
Depth: 289.75 mm
(11.41 in.)
Weight:3.318kg
(4.366kg with complete
Shelf Kit)
Wall-mount and rackmount kits (19 in. EIA, 19
in. and 21 in. ETSI, 23 in.
WECO)
1830 PSS-4
Operating
environment
Maximum
number of client
interfaces per
chassis
Supported SFPs
and XFPs are
same as for 1830
PSS-1
Client interfaces
FE: 24
GE: 24
OC-3/STM-1:
24
OC-12/STM-4:
24
OC-48/STM16: 16
OC-192/STM
Power: -48 V DC or
+24V DC or 110/220 V AC
Maximum power
dissipation: 328 W
Typical power
dissipation: 230 W
Operating temperature:
-40C to +65C (-40F to
+149F)
Humidity:
- CO environment
- 85 percent long
term
- 95 percent short
term
- ETSI
- 95 percent long
term
- Hardened environment
- 100 percent long term
Regulatory and standards
compliance
Telcordia GR-3108-CORE Class
2
Telcordia NEBS level 1, GR-63CORE and GR-1089-CORE
FCC Part 15 Class A
UL Certification: UL 1950 and
UL 60950
CE mark: EN 300
386
IEC Safety: IEC
60950 and IEC
60825-1/2
CSA-22.2-No.25M90
ETSI ETS 300 019
- Storage: Hazard
level 1.2
- Transportation:
Hazard level 2.2
- Operational:
Hazard level 3.2
ETSI EN 300
019
- Storage: Class
1.2
- Transportation:
Class T2.3 and
Class 3.2
ETSI EMC
- EN 300 386 v1.3.2
- ES 201 468 v1.2.1
- EMC directive 89/336 LV
ETS 300 753
ANSI T1.308
RoHS-5
GR-383-CORE
VCCI