FUTEK HID ELECTRONIC -BALLAST
SPECIFICATIONS FOR MODEL: FT-HID 250WDD3P
Designed for heavy duty and high temperature weather use
PARAMETERS FT-HID 250WDD3 P
INPUT:
Rated Voltage 220V
Working Voltage Range 160 ~ 260 Vac
Frequency 50/60 Hz
System Current:
Full Capacity At 220V 1.2A +/- 5 %
Dimming Mode At 220V Lowest: 0.59A +/- 10%
System Circuit Power:
Full Capacity 265W +/- 5 % max
Dimming Mode Customized: Lowest 130W +/- 5 %
Power Factor: >0.99
Full Capacity
Dimming Mode > 0.96
Total Harmonic Distortion:
Full Capacity < 10%
Dimming Mode
OUTPUT:
Lamp Type HPSV 250- Philips Or Osram Or GE or equivalent
Lamp Wattage:
Full Capacity 250W +/- 2%
Dimming Mode Lowest at 106.2W +/- 5 %
Lamp Power Factor > 0.98
Lamp Voltage 100V + or – 5 %
Lamp Current Crest Factor < 1.6
Lamp Operating Frequency Range:
Full Capacity 45 ~ 52 KHz
Dimming Mode 63 ~ 70 KHz
Dimming Level Customized: From 100% to 50%
OPERATING ENVIRONMENT
Ambient Temperature (Ta) -20 ~ +65°C
Housing Temperature (Tc) Max +90°C + or – 10%
PROTECTION FEATURE:
Protection Enable,
No Load Condition
Reset by power reset
Hot Re igniting Time Approx 45~ 60 sec
Re ignition Before Tube Cooled Down Protection Enable,
Reset by power reset
Protection Enable,
Lamp Fault
Reset by power reset
Protected
Over Voltage > 270V ~ 420 Volt Auto connection when power back to normal working range
8 preprogrammed position via 3 DIP Switches according to attach
Dimming options dimming program ( Customized )
100% > 90% >75 % >65% > 50%
Dimming Range
1) Digital To Digital using 3micro-processors for maximum reliability
Dimming Technology 2) DD3 Technology , 5 Dimming steps
3) With Dimming Memory Position recall
Weight 1750 gm + or – 10%
Thermal Over Heat ( Tc > 100C) Protected ( micro processor thermal control 100C + 10C
Over and Under Voltage Protection Power Off “ Protected Under 140V and Over 270V “
Voltage Monitoring processor “GST” * Protected with 5 ~ 15 second Grouping Starting Technology *
Voltage Monitor Technology Delay Time ** 5 ~ 20 Seconds ( At start Mode Only )
STANDARD DESIGN TO COMPLIED:
Safety Standard EN60928
Performance Standard EN60929
EMC Immunity EN61547
Current Harmonic Emission EN61000-3-2
Voltage Flicker EN61000-3-3
RFI EN55015/CISPR 15
*GST : Grouping Start Technology will divide large quantities of Ballast in several groups with 2 seconds delay
Between each of them in order to minimize starting rush Intensity and to optimize supply transformer efficiency.
** Voltage Monitor Technology will protect ballast from Surge Current , bad contacts , non stable Voltage at start
*** Technical data subject to change without notice.